You are on page 1of 4

VF-61, VF-61E, VF-62

Clean Dry Fuels and Oils with


High Performance Aquacon® Filter
Cartridges

Features
• Free and emulsified water to
less than 5 ppm
• 1/2 micrometer particulate
removal
• Provides protection against
“slugs” of water
• Pressure increase signals
cartridge change
• Use with existing filter housings

VF-61 VF-61E
VF 61E VF-62
with Optional with Band with Optional
DP Gauge Clamp Closure Hand Knobs

Contact Information: Applications


Parker Hannifin Corporation Fuels Oils
Velcon Filtration Division • Jet Fuel • Insulating Oil
1210 Garden of the Gods Road
• Avgas • Hydraulic Oil
Colorado Springs, CO 80907
• Motor Gasoline • Lubricating Oil
phone 719 531 5855 • Diesel fuel
fax 719 531 5690 • Selected Solvents
vfsales@parker.com • Biodiesel Fuel

www.velcon.com
Description Over Pressure Caution
The VF-61, and VF-62 are versatile Protection To protect the fuel system,
filter housings designed for use with
several different high performance When exposed to a high concentration including the filter housing &
Aquacon filter cartridges, as well as a of water, the differential pressure other components, be sure to
variety of paper filters and coalescer/ across an absorbent cartridge (AC, install pressure relief valve(s).
separator cartridges. Refer to the ACO, AD, or ASL Series cartridges)
cartridge selection table on page 4. will immediately increase. Pressure Do not use Aquacon® absorbent
bypasses or other means to limit the cartridges (AC, ACO, AD or ASL
Aquacon cartridges filter out water
inlet pressure to 75 psi (5 bar) should Series) with pre-mixed jet fuel
by chemically locking it into layers of
super-absorbent media. Water removal be installed to prevent cartridge from containing anti-icing additives, or
efficiency is not affected by common collapsing. with gasoline/alcohol blends.
surfactants or additives. Water capacity
is as much as 1-1/2 quarts, depending
on the flow rate. These cartridges also Recommended Ordering
effectively filter out dirt, rust and other
particulates.(See caution) Spares: Information
• 1 each G-0986 Buna-N O-Ring
As a cartridge reaches its water-holding • Specify Model VF-61, VF-61E, or
limit, the media expands very rapidly • If Viton O-Rings are desired, 2 VF-62 Filter Housing
and restricts the flow. For oils and other each G-0986A
high viscosity liquids, the pressure drop • Unit is supplied with G-0986
• 6 each Cartridges Buna-N O-Ring and 1/8” valve
will rapidly increase, signaling the need
to change cartridges. and 1/2” drain plug installed. 1/2”
petcock drain valve is shipped
The VF-61, with ACO series cartridges loose.
installed, has become the standard
for low flow rate full flow aviation fuel • Cartridges are not supplied and
monitor applications. must be ordered separately.
Use the VF-61E with band clamp • Viton O-Rings (P/N G-0986A)
closure for areas with limited space. are available but must be
ordered separately. They are
Specification recommended for gasoline and
solvent applications.Caution
Filter Housing clamp; carbon steel shell with
VF-61, VF-61E, VF-62: TGIC-Polyester coated exterior Options
• Max. Pressure: 150 psi and interior.
• Part Number 554Y020 is a Carbon
• Connection: 1½” NPT • Weight:
Steel 1/2” NPT Ball Valve, with
• Seal: Buna-N O-Ring (P/N • VF-61: 10 lbs., Mounting Nipple
G-0986) Shipping Weight: 12lbs.
• Part Number CK-1488 quick
• 1/8” brass petcock vent valve • VF-61E: 8 lbs., release hand bolts (set of 4)
and 1/2” drain valve Shipping Weight: 10 lbs.\ to replace closure bolts (as shown
• VF-62: 16 lbs., on page 2) VF-61 and VF-62 only.
• Material:
Shipping Weight: 18 lbs. • Part Number 10678 Differential
• VF-61, VF-62: Die cast Pressure Gauge Assembly (See
aluminum head and closure Cartridges
Form #1959)
clamp assembly; carbon steel • Max. Operating Temp.: 200°F
shell with TGIC-Polyester • Collapse Strength: 75 psi (5 bar)
coated exterior and interior.
• pH Range: 5 - 9
• VF-61E: Die cast aluminum
head; stainless steel band • Nom. Filtration Efficiency: 98%
Dimensional Drawings
Drawings are not to scale. Dimensions are shown for estimating purposes only.

Allow 6 inches (15.2 cm) below the vessel to safely remove the vessel to gain access to the cartridge.

VF-61 VF-61E Clamp


Bolts (Optional: 10” with bolts)
8-1/2” 7-1/2”
5-7/16” (22.2cm) 5-7/16” (19cm)
(13.8cm) (13.8cm)
3” 3”
(7.6cm) (7.6cm)

13/32” Dia
(typ.) 13/32” Dia
(typ.)
1-1/2” NPT
1-1/2” NPT
20” 20”
(50.8cm) Optional CK-1488 Handles (50.8cm)
When assembled, the outside 6” 1/8”NPT
6”
(15cm) diameter becomes 10” (25.4cm) (15cm) Vent x3
1/8”NPT
Vent x3

1/2” NPT
1/2” NPT Drain
Drain
VF-61E has a band clamp closure.
Use in areas with limited space.

VF-62
Bolts
Optional Differential 8-1/2”
(22.2cm)
5-7/16”
Pressure Gauge (13.8cm)
3”
(7.6cm)
Color Indicates 13/32” Dia
Pressure Drop (typ.)

Green: Clean 0 - 15 psi 1-1/2” NPT


Red: Change 16 - 25 psi Optional CK-1488 Handles
When assembled, the outside
length becomes 10” (25.4cm)
32-1/2” 6”
(81.92cm) (15cm)
1/8”NPT
Vent x3

1/2” NPT
Drain
VF-62 has a longer body for areas and
applications that require higher flow rate.
Filter Cartridge Selection Table
Housing Product Cartridge Data Flow Rate
P/N being filtered Application P/N Sheet Type Micron (GPM)
ACO-512P3L Aquacon® 0.3 5-50
1681
Jet Fuel & ACO-51201L (Absorbent) 0.5 5-50
Avgas(1) Coalescer/ Jet: 5-35
OS-51288 1858 0.5
Separator Avgas: 5-45
Mo-gas AC-51205 1582 Aquacon® 5 5-50
AD-51225 1655 (Absorbent) 25 15-50
Dirt & Free
Diesel (1)
Coalescer/
VF-61, VF-61E

water OS-51286 2118 5 5-18


Separator
Aquacon®
Biodiesel AD-51225 1655 25 15-50
(Absorbent)
AC-51205 1582 5 Varies with oil
Oils Aquacon®
AD-51225 1655 25 viscosity(2)
(Absorbent)
Solvents ASL-51201 1692 1 5-50
FO-512PL1/2 0.5
FO-512PL05 1549 Paper Filter 5 Fuels: 5-50
ALL Dirt Oils: Varies with
FO-512PL25 25 oil viscosity(3)
FOS-512PL25 1734 Synthetic Filter 25
Jet Fuel &
ACO-52401L 1681 0.5 10-100
Avgas(1)
Motor Gasoline AC-52405 1582 5 10-100
Diesel (1)

AD-52425 1655 25 30-100


Biodiesel Dirt & Free Aquacon®
water (Absorbent)
Varies with
VF-62

AC-52405 1582 5
viscosity
Oils
See Form
AD-52425 1655 25
#1709
Solvents ASL-52401 1692 1 10-100
FO-524PL1/2 0.5
ALL Dirt FO-524PL05 1549 Paper Filter 5 2-100
FO-524PL25 25
(1) For aviation and diesel fuel applications, always install a differential pressure gauge or other means of determining differential pressure.
(2) See Data Sheet #1709 for absorbent cartridge (AC, AD) flow rates.
(3) See Data Sheet #1532 for paper filter (FO) flow rates, see Data Sheet #1747 for synthetic filter (FOS) flow rates.

Please consult installation instructions and operating procedures that accompany products for more detailed information.

© 2013 Parker Hannifin Corporation. Product names are trademarks or registered trademarks of their respective companies. VEL2105R2 08/13

Parker Hannifin Corporation


Velcon Filtration Division
1210 Garden of the Gods Road
Colorado Springs, CO 80907 USA
tel +1 719 531 5855
www.velcon.com

You might also like