Professional Documents
Culture Documents
CA NO. CEA/CZ-77 / 2022 - CONST OF 1 X 75 MEN CH /DH, 31 ARMY AVN SQN, 404 AVN GP AT MULTAN CANTT
To:
Our Reference No. SOM-156 Dated 08-Sep-2022
Your Reference no. 6117/55/E-6 Dated 15/08/2022
TENSION TEST REPORT
Gauge length 8 inch Description Deformed bar
Yeilding Stress Ult/Max Stress
Ultimate Stress
Ultimate Stress
Elongationn at
Yeilding Load
%age Strain at
Dia/Size (inch) Area (Psi) (Psi)
Load (Lbs)
Wt. (Ib/ft)
Maximum
Heat No.
Nomina
Nomina
Nomina
Nomina
Sr.No.
Actual
Actual
Actual
Actual
(inch)
(inch)
(Lbs)
l
l
1 1.472 0.750 0.743 0.44 0.4314 35711 42785
81161.36 82779.32 97238.64 99177.1 2.084 26.055
2 1.472 0.750 0.743 0.44 0.4314 Bend Test was performed on this sample and was found OK
3 1.067 0.625 0.632 0.31 0.3171 24374 30260 78625.81 76865.34 97612.9 95427.31 1.809 22.617
4 1.067 0.625 0.632 0.31 0.3171 Bend Test was performed on this sample and was found OK
5 0.370 0.375 0.372 0.11 0.1084 12050 13528 109545.5 111162.4 122981.8 124797 0.850 10.636
6 0.370 0.375 0.372 0.11 0.1084 Bend Test was performed on this sample and was found OK
7 0.661 0.500 0.498 0.2 0.198 19246 22569 96230 97202.02 112845 113984.8 1.278 15.982
8 0.661 0.500 0.498 0.2 0.198 Bend Test was performed on this sample and was found OK
9 0.361 0.375 0.368 0.11 0.1058 11800 13521 107272.7 111531.2 122918.2 127797.7 1.184 14.81
10 0.361 0.375 0.368 0.11 0.1058 Bend Test was performed on this sample and was found OK
Bend Test was performed on sample 2,4,6,8,10 and was found OK
Note: 1. The above results pertain to sample/samples supplied to the labortary
2. Unsealead sample