You are on page 1of 1

MAN3031

T21W MAN2311
MAN_0035 N3S6E08 10035000J000 0.088
T21I ASEA T11I L12I
T21 ISO BB 2 300/5 10/14 MVA 1600/5N2S10E03 100350003000 0.997 600/5
T21 CB 17 T11 CB L12 CB
MAN23L12
Y Y
T21 ISO BB 1 T21 ISO TRAF
N2S9 100350006000 1
TALLERES
0.2S5 - 5P30 Δ
0.5 - 5P10 0.5 - 5P10
MAN30B20 20 - 2x50 30 - 30 30 - 30
N3P2E01 10035000J000 0.25
B20 ISO BB 2
MAN30T21 N3P2E03 10035000J000 0.278 33 kV MAN23T11
MAN4031 B20 CB SALIDA TF2 13,2 kV L12 ISO ETH
N3P2E05 10035000J000 0.095 LLEGADA TF2
B20 ISO BB 1
T21D 3,28 kV T11D L12D
L13I
TRANSFERENCIA L22I N3P1E01 10035000C000 0.25
N2S9 100350007000 1 600/5
L22 ISO BB 2 400/5 N3P1E03 10035000C000 0.278
L13 CB
N4EQ2 10035001E000 1 N4S7E07 10035000P000 0.188 L22 CB N3P1E05 10035000C000 0.095 MAN23L13
L16I N3P3E01 10035000A000 0.276 MAN30L22 LA FRANCIA
600/5 L16 ISO BB 2
N3P3E03 10035000A000 0.309
L22 ISO BB 1 L22 ISO LINE INSULA 33 - kV 0.5 - 5P10
L16 CB 0.5 - 1 30 - 30
MAN40L16 50 - 50
LA ENEA L16U L16 ISO LINE L16 ISO BB 1 L13 ISO ETH
"0,2S5 - 5P30" L13D
N4P1E01 10035000P000 0.127 20 - 3x40 L22D
N4P1E02 10035000P000 0.127 N3S5E08 10035000D000
L22 ISO ETH
0.088 L14I
N4P1E06 10035000P000 0.143 N3S5E03 10035000D000 0.040 N2S9 100350008000 1 600/5
N4P1E08 10035000P000 0.048
L16D L24I N3P1E01 10035000D000 0.25
L14 CB
N4P1E10 10035000P000 0.284
L16 ISO ETH
L23 ISO BB 2 600/5 N3P1E03 10035000D000 0.278 MAN23L14
N4P1E11 10035000P000 0.016 N4EQ2 10035001F000 1 N4S7E07 10035000Q000 0.188 L23 CB N3P1E05 10035000D000 0.095 SAN PEREGRINO
N4P1E12 10035000P000 0.003 L17I MAN30L23 0.5 - 5P10
600/5 L17 ISO BB 2 L23 ISO BB 1 L23 ISO LINE CHINCHINA 30 - 30
L17 CB 0.2S5 - 5P30
MAN40L17 N0P5E01 10035000N000 0.48
20 - 2x40 L14 ISO ETH

INSULA 115 kV L17U L17 ISO LINE L17 ISO BB 1 N0P5E04 10035000N000 0,032
L14D
0.2S5 - 5P30 N0P5E05 10035000N000 0,102

N4P1E01 10035000Q000 0.127 20 - 3x40 N0P5E12 10035000N000 0,023


L23 ISO ETH L23D
N4P1E02 10035000Q000 0.127 N3S5E08 10035000E000 0.088
N4P1E06 10035000Q000 0.143 N3S5E03 10035000E000 0.040 L16I
N4P1E08 10035000Q000 0.048
L17D L24I N3P1E01 10035000E000 0.25
N2S9E01 100350009000 0.997 600/5
L17 ISO ETH
N4P1E10 10035000Q000 0.284
T21W L24 ISO BB 2 600/5 N3P1E03 10035000E000 0.278
L16 CB
N4P1E11 10035000Q000 0.016
N4EQ2 10035001G000 1
N4S7E07 10035000R000 0.188 L24 CB N3P1E05 10035000E000 0.095
MAN23L16
N4P1E12 10035000Q000 0.003 L18I T21I ABB T19I MAN30L24 TABLAZO
600/5 L18 ISO BB 2 T21 ISO BB 2 250/5 3X20 MVA 600 - 1200/5 T19 ISO BB 2 L24 ISO BB 1 L24 ISO LINE CHIPRE 0.5 - 5P10
L18 CB T21 CB 5 T19 CB 0.2S5 - 5P 30 - 30
MAN40L18 20 - 40 - 40
Y Y
ESMERALDA L18U L18 ISO LINE L18 ISO BB 1 T21 ISO BB 1 T21 ISO TRAF T19 ISO TRAF T19 ISO BB 1 L16 ISO ETH
"0,2S5 - 5P30" 0.2S Fs5 - 5P30 Δ 1 - 10P10
L16D
N4P1E01 10035000R000 0.127 20 - 3x40 30 - 30 - 30 90 - 60 - 120 L24 ISO ETH L24D
N4P1E02 10035000R000 0.127

N4P1E06 10035000R000 0.143


MAN40T21 115 kV MAN30T19
SALIDA TF1 33 kV LLEGADA TF1 L25I N3P1E01 10035000F000 0.25
N2S12E04 100350004000 0.994
N4P1E08 10035000R000 0.048
L18D L18 ISO ETH T21D 10 kV T19D T17X
N4P1E10 10035000R000 0.284 N4P2E01 10035000T000 0.157 L25 ISO BB 2 400/5 N3P1E03 10035000F000 0.278
T1 ISO TRAF ISO TRAF 45 kVA
N4P1E11 10035000R000 0.016
N4EQ2 10035001H000 1 N4P2E04 10035000T000 0.157 L25 CB N3P1E05 10035000F000 0.095
MAN23T17
N4P1E12 10035000R000 0.003 L19I N4P2E06 10035000T000 0.175 MAN30L25 S. AUXILIARES
200 - 500/5 L19 ISO BB 2 L25 ISO BB 1 L25 ISO LINE MARMATO 2 5A
N4P2E08 10035000T000 0.059 N3P2E01 10035000I000 0.25 13.2 kV
L19 CB N4P2E11 10035000T000 0.02 N3P2E03 10035000I000 0.278 0.5FS10 - 10P10 214/123 V
MAN40L19 N4P2E12 10035000T000 0.004 N3P2E05 10035000I000 0.095 20 - 20 MAGNETRON
PERALONSO L19U L19 ISO LINE L19 ISO BB 1
N4P2E13 10035000T000 0.119
0.2FS - 5P20
N4P1E01 10035000S000 0.127 20 - 20 -20 T17D
N4P1E02 10035000S000 0.127
L25 ISO ETH L25D
N4P1E06 10035000S000 0.143

N4P1E08 10035000S000 0.048


L19D L26I N3P1E01 10035000G000 0.25
L19 ISO ETH
N4P1E10 10035000S000 0.284 L26 ISO BB 2 400/5 N3P1E03 10035000G000 0.278

N4P1E11 10035000S000 0.016


MAN40B20 L26 CB N3P1E05 10035000G000 0.095

N4P1E12 10035000S000 0.003


MAN30L26
B20 ISO BB 2 L26 ISO BB 1 L26 ISO LINE MARMATO 1
B20 CB 0.5FS10 10P10 11U Relación 13.2kV/√3 / 115 V/√3
20 - 20 Clase "0,5 - 3P"
B20 ISO BB 1 Capacidad 10
N4P3E01 10035000K000 0.236
TRANSFERENCIA Modelo JDZX17-10
N4P3E06 10035000K000 0.264 Marca DALIAN
N4P3E11 10035000K000 0.03 11U Relación 115 kV √3 / 115 V √3 L26 ISO ETH L26D
N4P3E12 10035000K000 0.005
Clase 0.2 - 3P
Capacidad 10
MAN4011 Modelo EMF 145 L27I N3P1E01 10035000H000 0.25

Marca ABB L27 ISO BB 2 200/5 N3P1E03 10035000H000 0.278

L27 CB N3P1E05 10035000H000 0.095

MAN30L27
N4EQ2 10035001B000 1
L27 ISO BB 1 L27 ISO LINE VILLAMARIA
N4EQ2 10035001C000 1
0.5 - 5P
N4EQ2 10035001D000 1 50 - 50 UNI-DTS-MAN-PL-0001
CONVENCIONES NOTAS L27 ISO ETH L27D ÁREA GESTIÓN OPERATIVA
BARRAJE 230 kV
UNIDADES CONSTRUCTIVAS · En todos los códigos ID de los equipos de este Grupo
R

OPERACIÓN Y CALIDAD
TRANSFORMADOR DE CORRIENTE Inventario Inicial CRI Dic 2007 diagrama se omiten los 5 primeros caracteres del
INTERRUPTOR TIPO CELDA
BARRAJE 115 kV CON DOS NÚCLEOS Y UN DEVANADO Rep. Parcial CRIN 2008-2017
mismo, (a excepción de barrajes y bahías) puesto
que aquellos que pertenecen al mismo nivel de
11U Relación 33kV/√3 / 115 V/√3
SECUNDARIO EN CADA NÚCLEO CONTIENE:
Nuevo CRIN 2008 - 2017 tensión, tendrán los mismos 5 primeros caracteres. Clase 0.2 - 3P
BARRAJE 33 kV
TRANSFORMADOR DE CORRIENTE No Reportado CRINR 2007 N3S32E14 10035000B000 0.016 Capacidad 10 DIAGRAMA UNIFILAR SUBESTACION MANIZALES
BARRAJE 13.2 kV
INTERRUPTOR DE POTENCIA CON DOS DEVANADOS Reporte 2018 · En la bahía MAN40L16, el PT solo en la fase B y C. N3S32E16 10035000B000 0.179 Modelo BPS30T
SECUNDARIOS EN UN NÚCLEO Plan de Inversión 2019 Marca BRASFORMER DISEÑÓ: APROBÓ:

BARRAJE 4.16 kV No contemplado plan 2019 · Remodelación de las celdas de 13.2 kV y los
MAN3011 CL 205-26291
DESCARGADOR DE sistemas de Control, Medida y Protección de la INGENIERO: N.A. MATRÍCULA PROF. INGENIERO: ALBERTO MISAS CIFUENTES MATRÍCULA PROF.
TRANSFORMADOR DE Plan de Inversión 2020 subestación, según el plan de inversión 2020.
SOBRETENSIÓN CORRIENTE CON TAP No contemplado plan 2020 FECHA ACTUALIZACIÓN REVISÓ (NOMBRE - ÁREA) FECHA IMPRESIÓN: NOMBRE ARCHIVO:
TRANSFORMADOR CON
Plan de Inversión 2021 · La relación indicada en los CT's que se muestra es
DOS DEVANADOS
TRANSFORMADOR No contemplado plan 2021 la correspondiente al núcleo de medida.
N3EQ11 10035000V000 1 20/04/2022 MARIA FERNANDA CUERVO A 20/04/2022 DU_SUB_25112019
TRANSFORMADOR SECCIONADOR CON FUSIBLE N3EQ11 10035000W000 1 1/10/2021 JOSE RUBEN RIOS G - SYL
DE TENSION (DIN) Plan de Inversión 2022 DIGITALIZÓ: ESCALA: PLANCHA:
TRIDEVANADO N3EQ11 10035000X000 1 2/2/2021 JOSE RUBEN RIOS G - SYL
No contemplado plan 2022

TRANSFORMADOR SECCIONADOR DE POTENCIA


TRANSFORMADOR DE BRAFO 12/12/2019 JOSE RUBEN RIOS G - SYL MARIA FERNANDA CUERVO A SIN 1
TRIFASICO CON TAPS MEDIDA COMBINADO 23/07/2018 JOSE RUBEN RIOS G - SYL DE: 1
3 BANCO DE SECCIONADOR DE PUESTA
TRANSFORMADORES A TIERRA
R RECONECTADOR La CHEC se reserva todos los derechos patrimoniales contenidos en este documento, y de su reproducción por cualquier medio y el uso por parte de terceros no podrá
hacerse sin previa autorización de CHEC ni ser utilizada de manera ilícita por su receptor.
MONOFASICOS
©CHEC S.A. E.S.P.