You are on page 1of 5

PRODUCT-DETAILS

AF96-30-00-11
AF96-30-00-11 24-60V50/60HZ 20-60VDC
Contactor

General Information
Extended Product Type AF96-30-00-11
Product ID 1SBL407001R1100
EAN 3471523133211
Catalog Description AF96-30-00-11 24-60V50/60HZ 20-60VDC Contactor
The AF96-30-00-11 is a 3 pole - 1000 V IEC or 600 UL contactor with screw terminals,
controlling motors up to 45 kW / 400 V AC (AC-3) or 60 hp / 480 V UL and switching
power circuits up to 130 A (AC-1) or 115 A UL general use. Thanks to the AF technology,
the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC),
Long Description managing large control voltage variations, reducing panel energy consumptions and
ensuring distinct operations in unstable networks. Furthermore, surge protection is
built-in, offering a compact solution. AF contactors have a block type design, can be
easily extended with add-on auxiliary contact blocks and an additional wide range of
accessories.

Ordering
Minimum Order Quantity 1 piece
Customs Tariff Number 85364900

Popular Downloads
Instructions and 1SBC101036M6801
Manuals
Dimension Diagram DNV_TAE00001AF-4
AF96-30-00-11 2

Dimensions
Product Net Width 70 mm
Product Net Depth / 116 mm
Length
Product Net Height 125.5 mm
Product Net Weight 1.22 kg

Technical
Number of Main 3
Contacts NO
Number of Main 0
Contacts NC
Number of Auxiliary 0
Contacts NO
Number of Auxiliary 0
Contacts NC
Rated Operational Main Circuit 1000 V
Voltage
Rated Frequency (f) Main Circuit 50 / 60 Hz
Conventional Free-air acc. to IEC 60947-4-1, Open Contactors q = 40 °C 130 A
Thermal Current (I th )
Rated Operational (690 V) 40 °C 130 A
Current AC-1 (I e ) (690 V) 60 °C 105 A
(690 V) 70 °C 90 A
Rated Operational (415 V) 60 °C 96 A
Current AC-3 (I e ) (440 V) 60 °C 96 A
(500 V) 60 °C 80 A
(690 V) 60 °C 57 A
(1000 V) 60 °C 30 A
(380 / 400 V) 60 °C 105 A
(220 / 230 / 240 V) 60 °C 105 A
Rated Operational (415 V) 60 °C 96 A
Current AC-3e (I e ) (440 V) 60 °C 96 A
(500 V) 60 °C 80 A
(690 V) 60 °C 57 A
(380 / 400 V) 60 °C 105 A
(220 / 230 / 240 V) 60 °C 105 A
Rated Operational Power (415 V) 55 kW
AC-3 (P e ) (440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(1000 V) 40 kW
(380 / 400 V) 45 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 25 kW
(220 / 230 / 240 V) 30 kW
Rated Operational Power (415 V) 55 kW
AC-3e (P e ) (440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(380 / 400 V) 45 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 25 kW
(220 / 230 / 240 V) 30 kW
Rated Short-time at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A
Withstand Current Low at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A
Voltage (I cw ) at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
for 1 s -empty- A
Maximum Breaking cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A
Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Maximum Electrical (AC-1) 600 cycles per hour
Switching Frequency (AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Rated Insulation Voltage acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
AF96-30-00-11 3

(U i ) acc. to UL/CSA 600 V


Rated Impulse 8 kV
Withstand Voltage (U imp
)
Maximum Mechanical 3600 cycles per hour
Switching Frequency
Rated Control Circuit 50 Hz 24 ... 60 V
Voltage (U c ) 60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Operate Time Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not 2 x M4 or 2 x M6 screws placed diagonally
supplied)
Connecting Capacity Flexible with Ferrule 1/2x 6 ... 50 mm²
Main Circuit Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²
Rigid 1x 6 ... 70 mm²
Rigid 2x 6 ... 50 mm²
Connecting Capacity Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Control Circuit Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping Length Main Circuit 17 mm
Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal Type Screw Terminals

Technical UL/CSA
General Use Rating (600 V AC) 115 A
UL/CSA
Horsepower Rating (120 V AC) Single Phase 7-1/2 hp
UL/CSA (200 ... 208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(240 V AC) Single Phase 20 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 75 hp
Tightening Torque Control Circuit 11 in·lb
UL/CSA Main Circuit 53 in·lb

Environmental
Ambient Air Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Temperature Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand Category B according to IEC 60947-1 Annex Q
Maximum Operating Without Derating 3000 m
Altitude Permissible
Resistance to Vibrations 5 ... 300 Hz 3 g closed position / 3 g open position
acc. to IEC 60068-2-6
Resistance to Shock acc. Closed, Shock Direction: A 25 g
to IEC 60068-2-27 Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
RoHS Status Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)


ABS Certificate ABS_20-2060694-PDA
BV Certificate BV_2634H36994A
AF96-30-00-11 4

CB Certificate CB_SE-96557M2
CCC Certificate CCC_2013010304646569
CQC Certificate CQC2013010304646569
Declaration of 2020980304001255
Conformity - CCC
Declaration of 1SBD250000U1000
Conformity - CE
Declaration of 1SBD250031U1000
Conformity - UKCA
EAC Certificate EAC_RU_FRME77B03447
Environmental 1SBD250168E1000
Information 1SBC100222M0201
GL Certificate DNV-GL_TAE00001AF-3
Instructions and 1SBC101036M6801
Manuals
KC Certificate KC_HW02016-15011C
LR Certificate LRS_1300087E1
RINA Certificate RINA_ELE084013XG
RMRS Certificate RMRS_1802705280
RoHS Information 1SBD250000U1000
UL Certificate UL_20130926-E312527_14_1
UL Listing Card UL_E312527

Container Information
Package Level 1 Units box 1 piece
Package Level 1 Width 150 mm
Package Level 1 Depth / 150 mm
Length
Package Level 1 Height 103 mm
Package Level 1 Gross 1.34 kg
Weight
Package Level 1 EAN 3471523133211
Package Level 2 Units box 8 piece
Package Level 2 Width 250 mm
Package Level 2 Depth / 300 mm
Length
Package Level 2 Height 300 mm
Package Level 2 Gross 10.72 kg
Weight
Package Level 3 Units 192 piece

Classifications
Object Classification Q
Code
ETIM 4 EC000066 - Magnet contactor, AC-switching
ETIM 5 EC000066 - Magnet contactor, AC-switching
ETIM 6 EC000066 - Power contactor, AC switching
ETIM 7 EC000066 - Power contactor, AC switching
ETIM 8 EC000066 - Power contactor, AC switching
eClass V11.0 : 27371003
UNSPSC 39121529
E-Number (Finland) 3707135
E-Number (Sweden) 3210055
AF96-30-00-11 5

Categories

Low Voltage Products and Systems  → Control Products  → Contactors  → Block Contactors

You might also like