SENSOR COMPARISON TABLE 1

MSIFEZ MSIPOW MSIPRE MSMWFEZ MSMW


Technology
INFRARED MICROWAVE
Sensor Type MOTION PRESENCE MOTION

Application Indoor

Installation Ceiling

Mounting Flush Mounting Surface Mounting Flush Mounting Surface Mounting

Corridor
Public Toilet Bathroom
Suitable location Hallways
Bedroom Bedroom
Stairs
Meeting Room Meeting Room
Lobby Lift

FEATURE

Indentify Day or Night

Continually Time Delay

Adjustable Sensitivity

Adjustable Time Delay

SPECIFICATION
o
Detection range 360

Detection distance 1-8m radius


Max. 8m ( 24 o ) Max. 20m ( 24o )
( radius ) (adjustable)

Detection speed 0.6 - 1.5m /s

Frequency 5.8 Ghz (CW radar, ISM band)

Max. Rated Load


800W / 400W 2000W / 1000W 1200W / 300W 2000W / 1000W
Resistive/ Capacitive

Power Source 220-240V/AC 50/60Hz

Power Consumption Approx. 0.5 W Approx. 0.9 W

Time Delay ( adjustable ) 10 sec ± 3 sec to 10 sec ± 3 sec to 10 sec ± 3 sec to


15 min ± 2 min 30 min ± 2 min 12min ± 1 min

Ambient light <3-2000 LUX (adjustable daylight sensor)

Installation height 2.2 - 4m 2.2 - 6m 1.5 - 3.5m 2-6m

oxH oxH LxWxH oxH oxH


Dimension (mm)
80 x 71 115 x 24 103 x 103 x 58 80 x 67 115 x 24

Working humidity o
<93% RH -20~ +40 C
& Temperature

Product specification and Information in this publication can change at any time without prior notice. www.boss.co.id
SENSOR INFRA RED 2

FEATURES
Identify day and night
It can work in the daytime and at night when it is
adjusted on the “SUN” position (max). It can work in
the ambient light less than 3LUX when it is adjusted
on the “3” position (min). As for the adjustment
pattern, please refer to the testing pattern.

Adjustable sensitivity
It can be adjusted according to using location. The 8m
detection distance of low sensitivity could be only
MAX LOAD
2m and high sensitivity could be 16m which fits for 800
watt
large room. 400
MSIFEZ watt

Time–Delay is added continually


When it receives the second induction signals
wihtin the first induction, it will restart to time from 360o
the moment.

Time–Delay is adjustable

2.2-4 m
Max 4 m Max 4 m
It can be set according to the consumer’s desire.
The minimum time is 10sec±3sec. The maximum is
12min±1min.
4m 4m

INSTALLATION CONNECTION

Avoid pointing the detector towards 1 Swing the plastic cover a little and adjust TIME and LUX knob.
objects with highly reflective surfaces, 2 Unload the transparent vinyl cover, loose the screws in
such as mirrors etc. the connection terminal, and then connect the power to
connection terminal of sensor according to connection-wire
diagram.
Avoid mounting the detector near 3 Fold the metal spring of the sensor upwards, until they are in
heat sources, such as heating vents, air “I” position with sensor, and then put the sensor into the hole
conditioning units, light etc. or installation box which is on the ceiling and has the similar
size with the sensor. Releasing the spring, the sensor will be
set in this installation position.
Avoid pointing the detector towards 4 After finishing installing, turn on the power and then test it.
objects that may move in the wind, such
as curtains, tall plants etc.

WIRING DIAGRAM

TEST 1. 2. N L

1 Turn the TIME knob anti-clockwise on the minimum (10s).


Turn the LUX knob clockwise on the maximum (SUN).
2 Switch on the power; the sensor and its connected lamp will 4.
have no signal at the beginning. After Warm-up 30sec, the 3.

sensor can start work .If the sensor receives the induction
signal, the lamp will turn on. While there is no another
induction signal any more, the load should stop working
NLL
within 10sec±3sec and the lamp would turn off.

3 Turn LUX knob anti-clockwise on the minimum (3). If the


ambient light is more than 3LUX, the sensor would not work
and the lamp stop working too. If the ambient light is less
than 3LUX (darkness), the sensor would work. Under no TIME LUX
90s 3min 30 300
induction signal condition, the sensor should stop working 30s 7min
within 10sec±3sec.
TIME LUX
90s 3min 30 300
30s 7min

10s 15min 10s 15min 3 3

Note: when testing in daylight, please turn LUX knob to (SUN)


position, otherwise the sensor lamp could not work!

www.boss.co.id
SENSOR INFRA RED 3

20m 20m

MAX LOAD MAX LOAD


2000
watt
2000
watt
1000 1000
MSIPOW watt
MSIPRE watt

360o
2.2-4 m

2.2-6 m
Max 4 m Max 4 m

presence - 6 m
4m 4m 10 m 10 m motion - 20 m

CONNECTION CONNECTION

1 Please move the upper cover with anti- 1 Unload the cover directly, then adjust TIME and LUX knob.
clockwise whirl as per the diagram on
the right, then adjust TIME and LUX 2 Connect the power and the load into the connection-
wire column of the sensor according to connection-wire
knob.
diagram.
2 Connect the power and the load
3 Fix the sensor on the selected position with the inflated
according to the connection-wire
screw as the figure on the bellow.
diagram.
4 Install back the cover and then you can test it.
3 Fix the bottom on the selected position
with the inflated screw.
4 Install back the upper cover on the
sensor, then you could switch on the
power and test it.

WIRING DIAGRAM WIRING DIAGRAM

A N L
L N N L
L N N L
L N
LOAD
IN

The wires come The wires come L


IN
in and out from in and out from N
OUT
the side. the bottom.
L N N L

30min 10s 3
15min 10s 3
12min
3
10min 30s
300
10s

7min
LUX TIME

30
6min
90s 5min

30s
30 300
30s 30 30s 10min

3min 300
LUX
10s
90s
3 30min

TIME

300 5min 90s


3min
30
LUX
90s
LUX TIME
TIME

Product specification and Information in this publication can change at any time without prior notice. www.boss.co.id
SENSOR MICROWAVE 4

MICRO 8m MICRO 8m
WAVE WAVE

MAX LOAD MAX LOAD


1200
watt
2000
watt
300 1000
MSMWFEZ watt
MSMW watt

5.8 Ghz 5.8 Ghz


CW radar CW radar
ISM band ISM band
< 0.2 mW < 0.2 mW < 0.2 mW < 0.2 mW

CONNECTION CONNECTION

1 Swing the plastic cover a little and adjust TIME, SENS and LUX knob. 1 Please move the upper cover with
anti-clockwise whirl as per the
2 Unload the transparent vinyl cover, loose the screws in
diagram on the right, then and
the connection terminal, and then connect the power to
adjust TIME, SENS and LUX knob.
connection terminal of sensor according to connection-wire
diagram. 2 Connect the power and the load
according to the connection-wire
3 Fold the metal spring of the sensor upwards, until they are in
diagram.
“I” position with sensor, and then put the sensor into the hole
or installation box which is on the ceiling and has the similar 3 Fix the bottom on the selected
size with the sensor. Releasing the spring, the sensor will be position with the inflated screw.
set in this installation position.
4 Install back the upper cover on the
4 After finishing installing, turn on the power and then test it. sensor, then you could switch on
the power and test it.

WIRING DIAGRAM WIRING DIAGRAM

1. 2. N L
L N N L
L N N L
L N
LOAD
IN

4.
3.
The wires come The wires come
in and out from in and out from
the side. the bottom.
NLL L N N L

LUX TIME
90s 3min 12min 10s 3
30 300 3
12min

30s 6min 6min


10s
6min

30s
30
30s
300
3min
90s LUX
TIME
TIME SENS LUX
90s 3min 30 300 SENS
300 30
10s 12min
30s 7min

3 10s 15min 3
3min 90s
TIME LUX

SENS

SENS

www.boss.co.id
TROUBLESHOOTING 5

The sensitivity is poor For Wicrowave version only


Please check if in front of the sensor there shouldn’t be Can not be installed on the uneven and shaky surface
obstructive object that affect to receive the signals. In front of the sensor there shouldn’t be obstructive
Please check if the signal source is in the detection fields. object affecting detection.
Please check the installation height. Avoid installing it near the metal and glass which
may affect the sensor.
For your safety, please don’t open the case if you
The sensor can’t shut automatically the load find hitch after installation.
If there are continual signals in the detection fields.
If the time delay is set to the longest.
If the power corresponds to the instruction.

The load don’t work WARNING


Check the power and the load. Danger of death
Whether the indicator light is turned on after sensing? through electric shock!
If yes, please check load.
Must be installed by professional electrician.
If the indicator light is not on after sensing, please check Disconnect power source.
if the working light correspondsto the ambient light. Cover or shield any adjacent live components.
Please check if the working voltage corresponds to the power Ensure device cannot be switched on.
source. Check power supply is disconnected.

Scan QR
for Digital Copy
of this brochure

Product specification and Information in this publication can change at any time without prior notice. www.boss.co.id
MS.A.SS.02 - 0121 ENG

MICROWAVE
SENSOR
www.boss.co.id

You might also like