Professional Documents
Culture Documents
BΩSS - MOTION Sensor
BΩSS - MOTION Sensor
& PRESENCE
SENSOR
www.boss.co.id
Tangga
Darurat
Gudang
Lobby Lift
Bathroom Garage
www.boss.co.id
SENSOR COMPARISON TABLE 1
Application Indoor
Installation Ceiling
Corridor
Public Toilet Bathroom
Suitable location Hallways
Bedroom Bedroom
Stairs
Meeting Room Meeting Room
Lobby Lift
FEATURE
Adjustable Sensitivity
SPECIFICATION
o
Detection range 360
Working humidity o
<93% RH -20~ +40 C
& Temperature
Product specification and Information in this publication can change at any time without prior notice. www.boss.co.id
SENSOR INFRA RED 2
FEATURES
Identify day and night
It can work in the daytime and at night when it is
adjusted on the “SUN” position (max). It can work in
the ambient light less than 3LUX when it is adjusted
on the “3” position (min). As for the adjustment
pattern, please refer to the testing pattern.
Adjustable sensitivity
It can be adjusted according to using location. The 8m
detection distance of low sensitivity could be only
MAX LOAD
2m and high sensitivity could be 16m which fits for 800
watt
large room. 400
MSIFEZ watt
Time–Delay is adjustable
2.2-4 m
Max 4 m Max 4 m
It can be set according to the consumer’s desire.
The minimum time is 10sec±3sec. The maximum is
12min±1min.
4m 4m
INSTALLATION CONNECTION
Avoid pointing the detector towards 1 Swing the plastic cover a little and adjust TIME and LUX knob.
objects with highly reflective surfaces, 2 Unload the transparent vinyl cover, loose the screws in
such as mirrors etc. the connection terminal, and then connect the power to
connection terminal of sensor according to connection-wire
diagram.
Avoid mounting the detector near 3 Fold the metal spring of the sensor upwards, until they are in
heat sources, such as heating vents, air “I” position with sensor, and then put the sensor into the hole
conditioning units, light etc. or installation box which is on the ceiling and has the similar
size with the sensor. Releasing the spring, the sensor will be
set in this installation position.
Avoid pointing the detector towards 4 After finishing installing, turn on the power and then test it.
objects that may move in the wind, such
as curtains, tall plants etc.
WIRING DIAGRAM
TEST 1. 2. N L
sensor can start work .If the sensor receives the induction
signal, the lamp will turn on. While there is no another
induction signal any more, the load should stop working
NLL
within 10sec±3sec and the lamp would turn off.
www.boss.co.id
SENSOR INFRA RED 3
20m 20m
360o
2.2-4 m
2.2-6 m
Max 4 m Max 4 m
presence - 6 m
4m 4m 10 m 10 m motion - 20 m
CONNECTION CONNECTION
1 Please move the upper cover with anti- 1 Unload the cover directly, then adjust TIME and LUX knob.
clockwise whirl as per the diagram on
the right, then adjust TIME and LUX 2 Connect the power and the load into the connection-
wire column of the sensor according to connection-wire
knob.
diagram.
2 Connect the power and the load
3 Fix the sensor on the selected position with the inflated
according to the connection-wire
screw as the figure on the bellow.
diagram.
4 Install back the cover and then you can test it.
3 Fix the bottom on the selected position
with the inflated screw.
4 Install back the upper cover on the
sensor, then you could switch on the
power and test it.
A N L
L N N L
L N N L
L N
LOAD
IN
30min 10s 3
15min 10s 3
12min
3
10min 30s
300
10s
7min
LUX TIME
30
6min
90s 5min
30s
30 300
30s 30 30s 10min
3min 300
LUX
10s
90s
3 30min
TIME
Product specification and Information in this publication can change at any time without prior notice. www.boss.co.id
SENSOR MICROWAVE 4
MICRO 8m MICRO 8m
WAVE WAVE
CONNECTION CONNECTION
1 Swing the plastic cover a little and adjust TIME, SENS and LUX knob. 1 Please move the upper cover with
anti-clockwise whirl as per the
2 Unload the transparent vinyl cover, loose the screws in
diagram on the right, then and
the connection terminal, and then connect the power to
adjust TIME, SENS and LUX knob.
connection terminal of sensor according to connection-wire
diagram. 2 Connect the power and the load
according to the connection-wire
3 Fold the metal spring of the sensor upwards, until they are in
diagram.
“I” position with sensor, and then put the sensor into the hole
or installation box which is on the ceiling and has the similar 3 Fix the bottom on the selected
size with the sensor. Releasing the spring, the sensor will be position with the inflated screw.
set in this installation position.
4 Install back the upper cover on the
4 After finishing installing, turn on the power and then test it. sensor, then you could switch on
the power and test it.
1. 2. N L
L N N L
L N N L
L N
LOAD
IN
4.
3.
The wires come The wires come
in and out from in and out from
the side. the bottom.
NLL L N N L
LUX TIME
90s 3min 12min 10s 3
30 300 3
12min
30s
30
30s
300
3min
90s LUX
TIME
TIME SENS LUX
90s 3min 30 300 SENS
300 30
10s 12min
30s 7min
3 10s 15min 3
3min 90s
TIME LUX
SENS
SENS
www.boss.co.id
TROUBLESHOOTING 5
Scan QR
for Digital Copy
of this brochure
Product specification and Information in this publication can change at any time without prior notice. www.boss.co.id
MS.A.SS.02 - 0121 ENG
MICROWAVE
SENSOR
www.boss.co.id