Blowers

Data sheet
Kongskilde’s FRL, FEA and TRL blowers constitute a range of
proven conveying blowers, which are an ideal energy source
for a vast number of industrial material handling systems.
The Kongskilde blowers are very Description
suitable for a wide variety of The aerodynamic shape of the
applications, including air supply, Kongskilde blower ensures
conveying purposes, and ventilation high efficiency and low energy
where high pressure are required. consumption.

The blowers can be used for both The blowers are designed as a
suction- and blowing systems as well centrifugal fan with a perfectly
as suction-blowing-systems. balanced rotor and thus a
But they are not intended for corrosive vibrationfree operation, which
gases and the air temperature must minimises the noise level.
not exceed 70°C.
Application
FRL/FEA But they are also very suitable for most TRL 20/40/55/75
Kongskilde’s FEA 10 is a one-stage suction purposes e.g. suction of TRL 20/40/55/75 are directly driven.
centrifugal blower with a closed rotor welding fume as well as to solve many TRL 20/40/75 are supplied with air
with 6 forward curved blades. It is ventilation tasks. intake mesh guards.
particularly built for ventilation tasks.
Suitable applications include suction The small and medium-sized blowers TRL 55 is supplied with automatic air
of welding fume and gases. are one-stage centrifugal blowers with regulator.
closed rotors, whereas TRL 300 and
FRL 10 is a one-stage centrifugal 500 have two respectively three TRL 100/150/200
blower with an open rotor with 8 stages, which also are equipped with, Within the TRL 100/150/200 blowers,
backward curved blades. Therefore, closed rotors. pressure and air volume can always be
light material as e.g. plastic flakes can adjusted to the purpose thanks to the
successfully be conveyed through the TRL 55/100/150/200/300 and 500 are ability of adjusting the rpm of the
fan. The blower is at the same time equipped with air regulator. rotor.
very suitable for light dust and Combining the blower with an air The blowers can be fitted with 7.5 to
shavings exhaust purposes. regulator optimises the conveying 15 kW motors, which have been
air speed by keeping the air velocity adjusted to the rpm of the rotor.
Both types (FRL/FEA) are available below 25 m/s, which minimises
with and without motor. damage of the material even when The blowers are delivered with V-belt
conveying delicate materials. The transmission.
TRL constant air velocity does also
The Kongskilde high-pressure blowers prevent overloading of the motor and TRL 300/500
are available in a wide range of sizes – minimises the power consumption. The special advantage of the TRL
providing a variety of performance 300/500 blowers is that they are
characteristics capable of meeting TRL20/40 can be used as either capable of supplying an exceptional
specific industrial requirements. transport blower or suction blower high pressure caused by the two-
whereas the TRL 55/75/100/150/ respectively three-step construction as
The TRL range with accessories is ideal 200/300/500 can be utilised for both each stage of the blower increases the
for conveying of granular material and suction and blowing as well as they air pressure.
similar products with specific weight can be installed as a combination of a
between 0.2 and 0.8 ton/m3. suction-blowing-system.

Standard Equipment Accessories Options


The Kongskilde blowers are as standard Kongskilde’s product range includes an All blowers are available with motors
delivered with motor, protection IP 55, assortment of rotary valves, injectors, suitable for 60 Hz. Directly driven
and closed rotor. cyclones and a wide range of pipe blowers is supplied with different rotor
components, suitable for combination sizes to suit the 60 Hz rpm.
TRL 20/40/55/75/100 are as standard with the blowers. Please see
delivered with motor, protection IP 55, Kongskilde’s data sheets for further In- and outlet on the blowers can be
but they are also available without information on the specific items. connected to the Kongskilde OK-pipe
motor. system.
The TRL blowers can be equipped with
TRL 150/200/300/500 are as standard the illustrated inlets. TRL 75 is available in stainless steel.
delivered with motor, protection IP 55,
and automatic starter. But they are also
available without motor.
Dimensions
FRL 10/FEA10 TRL 20
332

675
531

130
307
107

635 335
206
485
463

TRL 40 TRL 55

840
860

120
120

755 420
420
755 580 670

TRL 75
860

140

420
755 580

These drawings are based on our present technical knowledge.


It is presented for information only and does not involve us in any commitment to supply.

Technical Data
FRL 10 FEA 10 TRL 20 TRL 40 TRL 55 TRL 75

Motor rating, kW (Hp) 0.75 (1) 0.75 (1) 1.5 (2) 3 (4) 4 (5.5) 5.5 (7.5)

Motor rpm 2900 2900 2900 2900 2900 2900

Electrical supply, V/Hz 3 x 400 V, 50 Hz

Amp. consumption 1.7 1.7 3.1 5.8 7.5 10.5

Min. fuse rating (approx.) 10 10 10 16 16 20

Rotor rpm 2900 2900 2900 2900 2900 2900

Weight w/o motor, kg 8.9 8.9 18 41 43 43

Weight w. motor, kg 21 21 35 67 76 96

Noise level, 1m distance dB (A) 76 76 83 82 91 85

Noise level, 7m distance dB (A) 61 61 64 64 77 71


Dimensions
TRL 100/150 TRL 200
830

119

1000

117
695
370
370 435
1140
1140 875

TRL 300 TRL 500

1006
929

108
120

583
955 MAX. 1380
1225 1135
1330

All blower outlets are OK160.


These drawings are based on our present technical knowledge.
It is presented for information only and does not involve us in any commitment to supply.

Technical Data
TRL 100 TRL 150 TRL 200 TRL 300 TRL 500

Motor rating, kW (Hp) 7.5 (10) 11 (15) 15 (20) 22 (30) 37 (50)

Motor rpm 2900 2900 2900 2900 2900

Electrical supply, V/Hz 3 x 400 V, 50 Hz

Amp. consumption 13.5 20 27 39 65

Min. fuse rating (approx.) 25 35 50 63 100

Rotor rpm 3650 4200 4700 4100 4300

Weight w/o motor, kg 69 69 69 149 190

Weight w. motor, kg 129 157 195 324 468

Noise level, 1m distance dB (A) 90 97 93 93

Noise level, 7m distance dB (A) 73 81 78 80

V Belt SPA-1600 SPA-1600 SPA-1600 SPA-1800 SPA-1900


raw edge raw edge raw edge narrow raw edge
2 pcs1 2 pcs1 2 pcs1 4 pcs1 3 pcs1
1
Please note that all V-belts must be re-ordered in matched sets.
Dimensions
TRL 600/750/1000

Technical Data
TRL 600 TRL 750 TRL 1000

Motor rating, kW (Hp) 45 (60) 55 (75) 75 (100)

Motor current 400V, 50Hz 78 94 126

Motor rpm 50Hz/60Hz 2960/3550

Amp. 78 96 129

Blower rpm with the OK160 throttle 3905 4310 4780

Blower rpm with the OK200 throttle 3375 3685 4280

Blower rpm without a throttle 3125 3440 3870

Weight w/o the motor (kg) 600 600 600

Noise level, 1m distance dB (A) 95 95 95


Kongskilde’s TRL blowers can be equipped with a number of inlets suitable for various
applications. The possible inlets are illustrated below.

Inlets TRL 20/40/75

TRL 20/40/75 TRL 20/40/75


with protection net 121 140 175 without protection net
90° Special Bend

121 000 549


121 000 358 122 050 150 Adaptor
8"/200 mm Transition OK200 Quick Release Clamp
Clamp for inlet
2 x 121 000 727

121 005 084


90° Special Bend

122 000 159


8" Bolt Clamp

121 000 367


Taper 200/160

Inlets TRL 55/100/150

TRL 55, 100/150 TRL 55, 100/150


With protection net without protection net and air
and air regulator regulator. Is normally not
121 140 175 recommended.
90° Special Bend

121 000 727a 121 000 358


Clamp for inlet 122 050 150
121 000 549
OK200 Quick Release Clamp

121 005 084


90° Special
Bend

122 000 159


8" Bolt Clamp

121 000 367


Taper 200/160
Pressure
FRL/FEA TRL
Pressure total, Pt Pressure total, Pt
kPa mm.WG. kPa mm.WG.
kPa

Air volume m3/h Air volume m3/h

PerformanceTRL600
curves forPerformance
TRL600 –curves
1000 without
regulationair regulator:
Air Reg.– 1000
- 1000 w.o.
Performance curves
TRL600 for
- 1000 TRL600
OK160,
8000
with air regulation for OK160:
7000
9000
6000
8000
Pressure (mm WG)

5000 7000
TRL1000
4000 6000
TRL750 TRL1000
mm WG

3000 TRL600 5000


TRL750
2000 4000 TRL600

1000 3000
2000
0
0 1000 2000 3000 4000 5000 6000 7000 1000
m3/h
0
0 500 1000 1500 2000
m3/h

Air volume
The max. air volume delivered by the TRL blowers with air regulator is approximately 1800 m3/h at different pressures
depending on the type of blower. It is a general rule in pneumatic conveying that the higher pressure in the system, the
higher the transfer rate.
123001859 EXP/GB/TRL/DATA/0319
Subject to be changed without notice.

Kongskilde Industries A/S


Tel.: +45 72 17 60 50
industry@kongskilde-industries.com
www.kongskilde-industries.com