NCE Positioning
NCE is an innovative network cloudification engine
Operator BSS/OSS Mobile terminal
developed by Huawei. Positioned as the brain of future
cloud-based networks, NCE integrates functions such as
Application
Conversion Verification Decision Forecast Suggestion NCE aims to build an intent-driven network (IDN) that is first
Basic
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 4
Integrating Traditional Manager, Controller, and Analyzer Capabilities to
Achieve Unified Management and Control
U2000 eSight AC-WAN AC-SDWAN uTraffic NetStar
CloudOpera AC-T
NetOpen Orchestrator SDN
N2510 SecoManager
AC-Campus
AC Super IP Crystal
AC-DCN
Incorporated:
p Most features of U2000, uTraffic, AC-WAN, AC-T, AC-Campus, AC-DCN,
and AC-SDWAN
p NetOpen, an open and enabling platform for home networks, providing
home Wi-Fi network management
p CloudOpera Orchestrator SDN, an SDN orchestrator developed in 2017,
Manager Controller Analyzer focusing on multi-domain private line service provisioning. AC Super, a
super controller developed in 2018, delivered for Multi-Layer Network
Navigator
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 5
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
NCE Characteristics
NCE is a network lifecycle automation platform that integrates management, control, and analysis. It focuses on service automation,
O&M automation, and network autonomy to support carriers' network cloudification and digital operation transformation.
Unified Management and Control Supporting Smooth Cloud Platform Supporting Block-Building
Network Evolution Deployment
n Integrates traditional NMS and SDN controller functions. n Uses a unified cloud platform, user portal, and API gateway,
n Achieves unified management and control of SDN and non- achieves unified installation, deployment, and upgrade, and
SDN networks, leverages SDN network automation, explores consistent data models, and greatly simplifies O&M.
legacy network values, and reduces technical difficulties and n Adopts a microservice architecture, achieves user scenario-
risks of network evolution. specific on-demand deployment.
Product
Open APIs and Programmability Supporting Fast Characteristics Big Data-based Proactive Maintenance
Service Rollout
n Provides standard RESTful APIs to connect to external n Collects network-wide data (using the Telemetry technology),
systems. and based on the big data platform, performs panoramic and
n Provides a DevOps-based tool platform to flexibly customize in-depth analysis on the quality and traffic data of the entire
innovative services based on flexible business scenarios and network to implement intelligent analysis and predictable
network technologies. (not provided in the current version) maintenance.
n Continuously verifies network design and configuration to
ensure that the network accurately implements the users'
intention and achieves stable operation.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 6
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
U2000/AC/uTraffic NCE
Portal Northbound Portal Northbound Portal Northbound Portal Northbound Portal NBI
U2000 uTraffic
AC-WAN AC-T
Network management
Network control Network control
Network analysis and Network Network analysis
(FCAPS) assurance Network Control
management and assurance
SBI SBI SBI SBI
SBI
Managed
Network Metro Converged Managed
(Legacy + Network Backbone Metro Converged
network Network Backbone
SDN)
1. Traditional U2000 manages the entire network, including legacy 1. Integrates network management, control, and analysis, manages the
networks. entire network (Legacy+SDN, access/IP/transport) lifecycle, and
2. AC-WAN and AC-T provision and control SDN networks in the IP enables network automation.
and transport domains. 2. Supports the cloud architecture, provides a unified portal,
3. uTraffic performs O&M assurance for the entire network, including northbound and southbound interfaces, and engineering platform,
legacy networks. and supports smooth capacity expansion.
4. Customers need to switch between these systems to implement 3. Opens network capability, provides OpenAPI and designer, and
the required functions, which bring decentralized management supports scenario-specific app development and rollout.
risks in the network.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 7
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
2 Automation engine
3 Analysis engine
④ Intent engine: Converts business logic to network
operations and performs continuous verification to ensure
Management Control Perception analysis sustained business intent.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 8
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
middleware
Distributed Service center DB KAFKA
VM resource
Inspection and transaction
planning
O&M
Middleware Task management Redis ETCD APIGateway
management
OS configuration
planning Running platform Cloud-based
OS: EulerOS (Delivered) deployment
Physics machine FusionCompute
hardware (TaiShan
Communication
200 (Model 2280), Delivered hardware (TaiShan Private cloud (FS) HUAWEI CLOUD
matrix planning
2288X V5, and 200 (Model 2280), 2288X V5,
RS221G1) and RS221G1)
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 9
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Service
Network/service management Network monitoring Network control information trails.
l Pre-computes service trails and periodically re-
Analysis engine
Composite service VPN monitoring and IP trail MPLS IP
diagnosis visualization optimization optimization
optimizes the trails.
L3VPN L2VPN Tunnel service Automatic fiber
monitoring
Performance
monitoring
Centralized trail
computing
Route
topology q Network monitoring
OTN/ASON SDH/ASON ETH
l Provides basic O&M assurance for networks and
Packet service fault diagnosis PCEP BGP-LS
services, including basic performance monitoring, test
diagnosis, and fault diagnosis
NE management Inventory management q NE and inventory management
IP NEs Access NEs Optical NEs Resources Topology l Manages IP networks, access NEs, and optical NEs in
a unified manner, including device resource allocation
Third-Party NEs PnP Services Resource pool and southbound connection.
l Manages physical topology, Layer 1, Layer 2, and
Southbound service Service SLA
Layer 3 topology of a physical network.
Close Loop
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 10
Currently supported
To be supported
NCE Analyzer Architecture and Functions (L1)
Design APP q Application layer
Studio l Application-oriented model, providing dedicated
Base station analysis Home analysis Enterprise analysis Campus analysis Application analysis
apps based on different usage scenarios.
Feedback
q Service layer
Intelligence engine (on local) l Modeling: Modeling and analysis of service
Model IDE Service layer
Monitoring Rule Inventory Anomaly
...
(PWE3 and EVPN) and network (NE, link, and
management engine management management tunnel) models.
Object AI Jobs
l Model management: Modeling and managing
property Network AI model objects related to services, networks, and devices
Domain
metric model
NE Network Service User App to provide services for monitoring.
Anomaly Traffic Fault
detection forecast forecast
... l Monitoring management: Starting massive
monitoring instances based on app requirements.
Model
Algorithm layer optimization SoftCom AI inference platform q Intelligence engine and algorithm layer
and update l Provides the AI algorithm running framework and
Traditional algorithm AI algorithm Migration Model Model Sample
test management receiving management executes the AI algorithms in task mode; provides
Pipeline
the automatic algorithm optimization capability.
IDE Computing and storage layer l Supports application of various analysis, forecast,
and identification algorithms based on the
DataSet machine learning and deep learning algorithms.
ODAE q Computing and storage layer
Pipeline Mgr AQL TQL Druid
TQL l Data processing: Uses big data engine in the
Script industry to process collected data.
NDP l Data storage: Uses the big data storage platform
AI operator in the industry to query data storage.
Kafka HDFS Spark
q Collection layer
l Provides multiple collection protocols, such as
Collection layer
Telemetry, Syslog, SNMP, and Qx, to collect
Collector SNMP Qx FTP Syslog Telemetry Net Stream massive data from devices in real time.
IDE
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 11
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
NCE Context
U2 U3
U1
Orchestration/OSS
Network Tenant System interfaces:
Designer Operator
I1
n Human-machine interfaces
Design
Studio (not
Portal Northbound interfaces
Basic
platform
① U1: Design UI
provided in
the current
version)
Common ② U2: O&M UI
services
Southbound interfaces
NCE and the carrier's OSS
Third-party Basic
adaptation
design
engineering
② I2: Southbound interfaces between
Southbound-driven
Huawei network Third-party network NCE and NEs
adaptation adaptation
I2
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 12
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Mobile
OSS/BSS/Orchestrator
app SDK
REST/XML/ REST/Web socket
CORBA/SNMP/Text/TL1/
Syslog
Radius
Authentication, Authorization and
Accounting
Script
AAA OptiX NetStar
NCE Script/XML
IBMS
REST/Qx/SNMP/NetConf/TL1/
TFTP/FTP/SFTP/Telnet/STelnet/ REST
REST OSPF/OSPF-TE/PCEP/BGP-LS/
BGP FlowSpec/BGP
RPD/MQTT/NetStream/Telemetry
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 13
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 14
Software and
Management Installation and
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 15
Software and
Management Installation and
Note: The preceding data is for reference only. For details about the specifications, see Product Description of the mapping SPC version.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 16
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Analyzer Number of SNMP/Qx instances N x 30 (applicable to NCE-T and NCE-IP, with a 15-minute collection period) N/A
management
capability Number of SNMP/Qx indicators N x 30 x 50 (applicable to NCE-T and NCE-IP, with a 15-minute collection period) N/A
Telemetry-based data collection N x 20 (with a 15-minute collection period. For the conversion with other periods, N/A
see Product Description.)
Intelligent incident processing < 80k equivalent NEs: 100 alarms per second (IP Analyzer)
N/A
capability 80k equivalent NEs: 200 alarms per second (IP Analyzer)
Note: The preceding data is for reference only. For details about the specifications, see Product Description of the mapping SPC version.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 17
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Collection Mode Equivalent NEs Collection Capability (Maximum Equivalent Records/15 Minutes)
SNMP 2000 20,000
SNMP 6000 60,000
SNMP 15000 150,000
SNMP 30000 150,000
SNMP 50000 150,000
SNMP 150000 1,500,000 (supports only northbound performance text files)
BULK 2000 40,000 (supports only northbound performance text files)
BULK 6000 120,000 (supports only northbound performance text files)
BULK 15000 300,000 (supports only northbound performance text files)
BULK 30000 300,000 (supports only northbound performance text files)
BULK 50000 300,000 (supports only northbound performance text files)
BULK 100000 6,000,000 (supports only northbound performance text files; maximum equivalent records/1 hour)
BULK 150000 12,000,000 (supports only northbound performance text files; maximum equivalent records/1 hour)
Note: The preceding data is for reference only. For details about the specifications, see Product Description of the mapping SPC version.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 18
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Topology capacity Subnets The number of created subnets is unlimited. Each subnet can contain a maximum Same as the Indicator column.
of 500 physical NEs at a maximum of six layers. 200 physical NEs are
recommended.
Alarm response speed In normal circumstances, alarms are displayed on NCE within 10 seconds after Same as the Indicator column.
they are generated on NEs.
Normally,
Alarm handling • 100 alarms per second when NCE manages NEs in all domains
Alarm handling capability • 50 to 400 alarms per second when NCE manages only access NEs
capability
• 100 to 300 alarms per second when NCE manages only transport NEs Same as the Indicator column.
• 100 to 200 alarms per second when NCE manages only IP NEs
In peak hours,
No alarm loss within 15 seconds when 1000 alarms are reported per second.
Note: An indicator marked xx to yy indicates that the indicator under the minimum network scale (3k) is xx and under the maximum network scale
(150k) is yy.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 19
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
System user management Object sets 100 Same as the Indicator column.
capability Operation sets 255 Same as the Indicator column.
Concurrent NE upgrades Maximum: 60 (for NE upgrade task management) Same as the Indicator column.
Maximum: 300 (for NE upgrade wizard)
GNEs <= 3000 <= 2000
Note: A single instance can manage 500 GNEs.
HWECC and IP over DCC
NEs under each GNE It is advisable to connect no more than 50 NEs to Same as the Indicator column.
networking capacity
a single GNE. The maximum number is 128.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 20
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
perception
Real-time
Intelligent
In-depth
analysis
forecast
management
management
management
Access
Optical
IP Optical Access
can be deployed together.
IP
control control control
CloudSOP
Manager Controller Analyzer Manager Controller Analyzer Manager Controller Analyzer Manager Controller Analyzer
Manager Controller Analyzer
managem
control
ent
IP
Access network
perception management
Optical control domain
management
management
management
management
private line
control
network
control
network
Access
Home
Optical
Analysis Analysis
management
management
management
Analysis Analysis Analysis
IP
IP
managem
Access
Optical
Optical
control
Optical
IP
ent
IP+optical
Forecast Forecast Forecast
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 21
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
NCE Networking
To improve network security and balance traffic on service interfaces, NCE uses different ports and links to
transmit data flows on different service planes. For example, NCE isolates management, service, and inter-
node communication data on different planes.
OSS
Network Plane Description Remarks
DCN The VM web client connects to the
DCN 1
client/northboun
NCE server through the management
Firewall
d network ... Management network network to remotely manage the -
hardware and virtualization
Web client environment.
The NCE web client connects to the 1. The service network is divided into
Client or NCE server and OSS through the three types: single network
Primary site Secondary site northbound client or northbound network to (southbound and northbound
DCN DCN network access the management plane and networks are not isolated, that is, the
management management
network Replication line network
O&M plane. southbound network reuses the
client or northbound network), dual
networks (southbound and
...
Server Server
... northbound networks are isolated
Service but Manager and Controller are not
VM Web client DCN VM Web client network isolated), and multiple networks
Southbound Southbound devices connect to the (southbound and northbound
network Southbound
NCE server through the southbound networks are isolated and Manager
network
network. and Controller are isolated).
2. 2. If the product type is NCE-Super,
the southbound device refers to a
Firewall domain controller. If the product type
is not NCE-Super, the southbound
Fiber device refers to an NE.
Standard network cable Nodes of the server communicate with
Southbound devices
each other through the inter-node
Internal communication
communication network. This network -
network
NMS TController NMS
does not need to be connected to
TController
Primary site Common_S Common_S Secondary external systems.
ervice ervice
site It is a data communication network
DB OMP OMP The IP address of the storage network is
DB between blades and disk arrays. This
automatically set to an IP address in the
Storage network (Applicable network does not need to be
192.168.0.x or 192.168.1.x network
to E9000) connected to external systems. (This
segment during installation. You do not
Internal communication/ network is optional, depending on
replication network need to configure it.
whether a disk array is used.)
The DR solution requires high
Management network
bandwidth. A replication link must be
Client login/ The DR network reuses the inter-node
northbound network DR replication network configured between the primary and
communication network.
Southbound network secondary sites for heartbeat
monitoring and data replication.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 22
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
EasySuite (unified planning and design, and installation and deployment based on the planning information)
Onsite installation
and deployment
Factory installation Plan commissioning.
management plane.
Install virtualization
Planning
commissioning.
Perform NCE
premises Use EasySuite to plan the installation and Install service nodes.
software.
server.
OS.
delivery Onsite installation deployment scheme and plan all hardware and
Parallel installation
software layers.
...
Install service nodes.
Private Plan only the deployment scheme and NCE
Onsite installation
cloud software. Manual operation
30 min 40 min 20 min 25 min 90 min 5 min 120 min
Automatic operation EasySuite-based one-click installation without manual intervention Wizard-based OMP
commissioning
Ø On-premises factory installation: NCE has been installed on the delivered hardware. Only deployment commissioning is required on the live network. The commissioning duration is less than 2 hours.
Ø On-premises onsite installation: EasySuite is used to install the hardware, VM, OS, and NCE. The total installation duration is less than 4 hours. The commissioning duration after the installation is less than 1 hour.
Ø Private cloud scenario (customers provide the infrastructure layer): After customers install the infrastructure layer and OS, Huawei engineers install NCE using EasySuite. The total duration is less than 2.5 hours.
After the installation, Huawei engineers then commission NCE. The commissioning duration is less than 1 hour.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 23
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Deployment Scenarios
n Based on whether Huawei provides E2E support for software and hardware, NCE can be deployed in two modes: on-premises and private cloud.
n On-premises deployment refers to software and hardware integration. Huawei provides the required hardware and software and completes the E2E configuration of the
software and hardware.
OS OS OS
Virtualization Virtualization Virtualization Physical machine Private cloud Private cloud (product
Virtualized deployment
deployment (OS+product) only)
Server Server Server
On-premises:
Huawei engineers configure the hardware, virtualization environment (not required for physical machine deployment), OS, database, and NCE software in an E2E manner. Generally, the
installation takes less than 4 hours.
Private cloud (OS+product):
After customers configure the FusionCompute KVM or EMS centralization environment, Huawei engineers create VMs and install the OS, database, and NCE software. Generally, the installation
takes less than 3 hours.
Private cloud (product only):
After customers configure the virtualization environment, Huawei engineers install the database and NCE software. Generally, the installation takes less than 2.5 hours.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 24
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Physical
Product Service Scenario Network Scale
Machines
6k equivalent NEs 3
15k equivalent NEs 4
Manager+Controller (MPLS network)+Analyzer (basic analysis)
NCE-IP 30k equivalent NEs 5
80k equivalent NEs (PTN) 12
Manager+Controller+Analyzer(Basic)+NIC 6k equivalent NEs (NIC) 4
6k equivalent NEs, 15k equivalent NEs 3
Manager+Controller 30k equivalent NEs 5
50k equivalent NEs 7
NCE-T 2k equivalent NEs (without Local protection) 1
6k equivalent NEs, 15k equivalent NEs 4
Manager+Controller +Analyzer
30k equivalent NEs 6
50k equivalent NEs 10
30k equivalent NEs 3
Manager+Controller 100k equivalent NEs 7
150k equivalent NEs 9
70k subscribers 1
Home network 100k subscribers 1
NCE-FAN
1 million subscribers 4
FANS 30k equivalent NEs 1
50k subscribers 1
Premium broadband + Home network 500k subscribers 4
1 million subscribers 6
Note: The preceding data is for reference only. For details about the specifications, see Release Notes of the mapping SPC version.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 25
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Note: The preceding data is for reference only. For details about the specifications, see Release Notes of the mapping SPC version.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 26
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Number of
Product Service Scenario Network Scale physical
machines
NCE-IP Manager 15k equivalent NEs, 30k equivalent NEs 1
NCE-T Manager 2k equivalent NEs, 6k equivalent NEs, 15k equivalent NEs, 30k 1
equivalent NEs
Manager+Controller 1k equivalent NEs for NCE Lite, 6k equivalent NEs for enterprise 1
networks, or 30k equivalent NEs
NCE-FAN
ODN Visualizer 1 million subscribers 1
NCE Manager 1k equivalent NEs for NCE Lite, or 2k equivalent NEs, 6k equivalent 1
NEs, 15k equivalent NEs, 30k equivalent NEs
Note: The preceding data is for reference only. For details about the specifications, see Release Notes of the mapping SPC version.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 27
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Note: The preceding data is for reference only. For details about the specifications, see Release Notes of the mapping SPC version.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 28
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Note: The preceding data is for reference only. For details about the specifications, see Release Notes of the mapping SPC version.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 29
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 30
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Note: The preceding data is for reference only. For details about the specifications, see Release Notes of the mapping SPC version.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 31
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 32
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Note: The preceding data is for reference only. For details about the specifications, see Release Notes of the mapping SPC version.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 33
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Space: 47 U
General Cabinet A610-22
Size (W x D x H): 600 mm x 1000 mm x 2200 mm
Note: The preceding data is for reference only. For details about the specifications, see Release Notes of the mapping SPC version.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 34
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 35
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Strategies:
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 36
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
In the reuse scenario, the OceanStor 5500 V3 disk array is supported. The
Controller card: 2 x SAS controller unit (48 GB cache) number of hard disks is not limited to the specifications described in the table.
Disk array OceanStor 5500 V3 Hard disk: 24 x 900 GB SAS HD hard disk To install NCE, you need to supplement the hard disk or replace the hard disk
Interface: 2 x 4 10GE ETH (SmartIO card SFP+) with a larger one based on the storage size required in the deployment
scenario.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 37
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 38
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
192G Added X
NEs
NCE
Two- 384G Added X
NCE Manager+ Single
Node
Manager Controller+ server Data migration of NCE Manager (either physical machines or private clouds) depends on NMS nodes only.
Cluster
512G Analyzer Added X-1
X indicates the number of destination servers A indicates the number of arbitration servers, which can be 0 or 1. A source server that fails be reused to install
(single-server deployment). NCE Manager+Controller+Analyzer can be used as an arbitration server.
Note: In principle, reusing source servers is recommended. For details about deployment scenarios and specifications, see the Migration Guide for related NCE versions.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 39
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Implementation Principles:
• Back up product data on the management plane of the source system and remotely restore the data on the
management plane of the target system.
Source: DR system; all hardware reused; target: DR system
Step Migrate Manager+Controller Data
③ Migrate data.
Monitoring continues but
1 Back up product data on the management plane of the source system.
services are not provisioned.
2 Transfer the backup files to the target system. Target primary site
Source primary site ⑥ Establish a DR relationship
3 Restore product data on the management plane of the target system. ⑤ Install the primary site on the and perform a switchover.
existing or new server. Monitoring is interrupted for 15
4 Perform other necessary operations on the target system. Services are not affected. minutes.
Source secondary site Target secondary site
① Remove the DR
relationship. ② Install the secondary site on the
Step Migrate Analyzer Data Services are not affected. existing or new server.
Services are not affected.
1 Connect the customer's third-party SFTP server to the source system.
2 Dump performance data on the O&M plane of the source system to the SFTP server. ④ Switch services to
the secondary site.
3 Connect the SFTP server to the target system. Source NCE
NEs Target NCE
4 Restore performance data on the O&M plane of the target system.
Note: For details about the scenarios and specifications, see the migration guide released with the product.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved.
40Page
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
On-premises:
Huawei engineers configure new servers, virtualization environment (not required for physical machines), and OS, and expand the NCE capacity in E2E mode. The expansion takes less than 4 hours.
Private cloud (OS+product):
After customers configure FusionCompute KVM and the EMS centralization environment, Huawei engineers create VMs, install the OS, and expand the NCE capacity. The expansion takes less than
3 hours.
Private cloud (product only):
After customers configure the virtualization environment, Huawei engineers expand the NCE capacity. The expansion takes less than 2.5 hours.
Restrictions:
Currently, the network capacity can be expanded only to a maximum of 30k equivalent NEs.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 41
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Note: The data provided on this page is for reference only. For the detailed specifications, refer to Project Capacity Expansion Baseline of the required version.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 42
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 43
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
Configuration
management
Manager
Indicators: RPO = 0s, RTO ≤ 3 min Indicators: RPO = 0s, RTO ≤ 3 min
Network
Network
Network
analysis
control
Protection: primary/secondary Protection: primary/secondary
Controller
Indicators: RPO = 0s, RTO ≤ 60s Indicators: RPO = 0s, RTO ≤ 60s
Application
layer Protection: microservice-level Protection: microservice-level
... Analyzer Indicators: RPO = 0s (configuration file), Indicators: RPO = 0s (configuration file),
RTO ≤ 3 min, RPO=45min (big data) RTO ≤ 3 min, RPO=45min (big data)
Protection: Cluster protection Protection: Cluster protection
OS/DB OS/DB OS/DB OS/DB NCE-Super
Indicators: RPO = 0s, RTO ≤ 60s Indicators: RPO = 0s, RTO ≤ 60s
VM 1 VM 2 VM 3 VM n Protection: Cluster protection Protection: Cluster protection
Basic platform CloudSOP
Indicators: RPO = 0s, RTO ≤ 60s Indicators: RPO = 0s, RTO ≤ 60s
FusionCompute
Protection: master/slave Protection: master/slave
Database Database
RPO = 60s, RTO ≤ 60s RPO = 60s, RTO ≤ 60s
1: N blade cluster protection, automatic
Virtualization
Private Cloud layer
FusionCompute NA recovery
Indicators: RPO = 0s, RTO ≤ 15 min
E9000 chassis: management module 1+1,
TaiShan: management module 1+1, power
E9000 chassis power supply 1+1, switch board 1+1
Local protection: microservice-level Blade server supply 1+1, switch board 1+1, NIC 1+1,
CH121 V5 blade Blade server: Mezz card 1+1, hard disk
hard disk RAID 1/RAID 10
DR: full-scenario application DR; switchover for RAID 1
all components on a site Hard disk RAID 10, hot-spare policy, disk
Disk array 5500V5 NA
array controller 1+1, power supply 1+1
Recovery point objective (RPO) refers to the data loss duration. Recovery time objective (RTO) refers to the service interruption duration.
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 44
Software and
Management Installation and
Positioning Architecture Hardware Migration Expansion HA
Capability Deployment
HA Capability: DR
Configuration
NCE DB
Service 1 Service 1
Linux DB
Service 2 DB Service 2
Asynchronous replication RPO <=
.. 60 seconds (service data of ..
. .
VM Manager and Controller)
File File
Service n Service n
Network delay < 50ms, package loss rate < 1%
Hypervisor Services Data Data Services
* It is recommended that a redundant private line connection be
replicated, and the switchover time is less than 1s.
DR based on database
Management Scale (Manager + Controller + Analyzer) 6000 15,000 30,000
replication is located at the
application layer. It is Minimum Bandwidth Requirements Between the Primary
decoupled from the and Secondary Sites 60 Mbit/s 100 Mbit/s 200 Mbit/s
infrastructure layer and (Excluding Analysis Data)
does not depend on
Management Scale (NCE Manager) 2000 6000 15,000 30,000
specific hardware or
virtualization platforms. Minimum Bandwidth Requirements Between the Primary
and Secondary Sites 8 Mbit/s 12 Mbit/s 30 Mbit/s 60 Mbit/s
(with the performance data collection function disabled)
Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Page 45