You are on page 1of 13

Document Title Security Level

Special for Vodafone Project Total 13 Pages

UMPT

SWAP PROCEDURE

2023-06-25 Huawei Proprietary - Restricted Distribution Page1, Total13


Document Title Security Level

1. UMPT Commissioning Procedure via USB

1. Modify the configuration to work as UMPT for this board. See “FROM WMPT TO
UMPT (like for like). For NO Co-TX site” and “Co-Transmission Scenario with
GTMUb. FROM WMPT (Co-Tx thru Front Panel using Optical Ports) TO UMPT (Co-
Tx thru Back Panel)” points described below.
2. Export the modified configuration file
3. Format a USB key, in FAT32 file system mode. This step is to make sure there is no
other file or folder in the USB key which may impact the USB commission.
4. If the software version in UMPT is V200R014C00SPC310(our FOA target version), skip
this step. Otherwise copy the software packet to USB key. The file pathname must be
usb:\NodeB\Software\Software.csp
5. Copy the configuration file to USB, the file pathname must be usb:\NodeB\
Configuration\NodeBCfg.xml
6. Use the USB protection tool to encrypt configuration file

7. Power off the NodeB, insert UMPT, then power on.


8. After the board is stable, you can see the RUN LED blinks slowly (ON for 1s and OFF
for 1s) , insert the USB key, the software(if needed) and the configuration file will be
read.
9. After NodeB reset, check if we can ping the IP configured on ETH port 0, if success, it
means the configuration file is ok.

2023-06-25 Huawei Proprietary - Restricted Distribution Page2, Total13


Document Title Security Level

2. UMPT Commissioning Procedure via LMT

1. Modify the configuration to work as UMPT for this board. See “FROM WMPT TO
UMPT (like for like). For NO Co-TX site” and “Co-Transmission Scenario with
GTMUb. FROM WMPT (Co-Tx thru Front Panel using Optical Ports) TO UMPT
(Co-Tx thru Back Panel)” points described below.
2. Export the modified configuration file.
3. Power off the NodeB, insert UMPT, then power on.
4. After the board is stable, you can see the RUN LED blinks slowly (ON for 1s and
OFF for 1s)
5. Connect laptop with “Special Cable” ETH - USB3.0 to USB port in UMPT board
6. Open LMT, version R14, and download configuration file from LMT.
7. After NodeB reset, check if we can ping the IP configured on ETH port 0, if
success, it means the configuration file is ok.

IMPORTANT INFORMATION
Logging to UMPT via LMT:
IP : 17.21.2.15
User: admin
Password: NodeB or hwbs@com

2023-06-25 Huawei Proprietary - Restricted Distribution Page3, Total13


Document Title Security Level

2.1.“Special Cable” information

2023-06-25 Huawei Proprietary - Restricted Distribution Page4, Total13


Document Title Security Level

3. FROM WMPT TO UMPT (like for like). For NO Co-TX site.

1.1. From CME


Open NodeB Configuration Express regarding NodeB swap.

IUB_NodeB – Device Panel Select WMPT Properties

2023-06-25 Huawei Proprietary - Restricted Distribution Page5, Total13


Document Title Security Level

Save current configuration of WMPT Properties

Delete WMPT

2023-06-25 Huawei Proprietary - Restricted Distribution Page6, Total13


Document Title Security Level

Add UMPT

2023-06-25 Huawei Proprietary - Restricted Distribution Page7, Total13


Document Title Security Level

Fill UMPT Properties with same values as old WMPT Properties

Export Configuration File

2023-06-25 Huawei Proprietary - Restricted Distribution Page8, Total13


Document Title Security Level

1.1. Modifying Data File Manually (Not Recommended)


Following parameter must be change in WMPT data file to obtain UMPT data file.

WMPT UMPT

<TYPE>8193</TYPE> <TYPE>1</TYPE> --> BOARD


BOARD:

“8193”: WMPT Board

“1”: UMPT Board

2023-06-25 Huawei Proprietary - Restricted Distribution Page9, Total13


Document Title Security Level

4. Co-Transmission Scenario with GTMUb. FROM WMPT (Co-Tx thru

Front Panel using Optical Ports) TO UMPT (Co-Tx thru Back

Panel)

4.1. From CME

Follow previous procedure to add UMPT board. Then:

- Add Device IP Address in Port 0 regarding IP Address and Mask of Port 1

- Remove Device IP Address of Port 1


RMV DEVIP:SN=7,SBT=BASE_BOARD,PT=ETH,PN=1,IP="172.19.174.193";
ADD DEVIP:SN=7,SBT=BASE_BOARD,PT=ETH,PN=0,IP="172.19.174.193",MASK="255.255.255.252";

2023-06-25 Huawei Proprietary - Restricted Distribution Page10, Total13


Document Title Security Level

Add TUNNEL
ADD TUNNEL:SSN=7,DSN=6;

Add IP Route thru TUNNEL.


ADD
IPRT:SN=7,SBT=BACK_BOARD,DSTIP="172.19.174.194",DSTMASK="255.255.255.255",RTTYPE=IF,IF
T=TUNNEL,DESCRI="UMPT-GTMU BACK PANEL";

2023-06-25 Huawei Proprietary - Restricted Distribution Page11, Total13


Document Title Security Level

Add BTS Configuration to be able to reach NodeB thru Back Panel. FOA Example:

MOD BTSESN:IDTYPE=BYID,BTSID=4,OMBEARBOARD=BACKBOARD;
RMV BTSIPRT:IDTYPE=BYID,BTSID=4,RTIDX=0;
RMV IPPATH:ANI=4,PATHID=0;
RMV IPPATH:ANI=4,PATHID=1;
RMV BTSDEVIP:IDTYPE=BYID,BTSID=4,PT=ETHPORT,PN=1,CN=0,SRN=0,SN=6,IPIDX=0;

ADD
BTSDEVIP:IDTYPE=BYID,BTSID=4,PT=LOOPINTERFACE,PN=0,CN=0,SRN=0,SN=6,IP="172.19.174.194"
,MASK="255.255.255.255";
ADD
BTSTUNNEL:IDTYPE=BYID,BTSID=4,SRCCN=0,SRCSRN=0,SRCSN=6,TN=0,DSTCN=0,DSTSRN=0,DSTSN=7;
ADD
BTSIPRT:IDTYPE=BYID,BTSID=4,RTIDX=0,DSTIP="172.19.253.134",DSTMASK="255.255.255.255",R
TTYPE=OUTIF,CN=0,SRN=0,SN=6,ITFTYPE=TUNNEL,IFNO=0;
SET BTSIP:IDTYPE=BYID,BTSID=4,BTSCOMTYPE=LOGICIP;
ADD
IPPATH:ANI=4,PATHID=0,ITFT=ABIS,PATHT=EF,TXBW=100000,RXBW=100000,VLANFLAG=DISABLE,PATH
CHK=ENABLED,ECHOIP="172.19.174.194",ABISLNKBKFLAG=OFF;
ADD
IPPATH:ANI=4,PATHID=1,ITFT=ABIS,PATHT=AF11,TXBW=100000,RXBW=100000,VLANFLAG=DISABLE,PA
THCHK=ENABLED,ECHOIP="172.19.174.194",ABISLNKBKFLAG=OFF;

2023-06-25 Huawei Proprietary - Restricted Distribution Page12, Total13


Document Title Security Level

Ports on the UMPT

Silkscreen Connector Description

FE/GE1 (optical SFP connector A 100 Mbit/s or 1000 Mbit/s adaptive Ethernet
port) optical port is used for transmitting service data
and signaling messages.

FE/GE0 RJ45 connector A 10 Mbit/s, 100 Mbit/s, or 1000 Mbit/s adaptive


(electrical port) Ethernet electrical port is used for transmitting
service data and signaling messages.

USB(1)(2) USB connector The USB port with the USB silkscreen is used for
the software upgrade of a base station using a
Universal Serial Bus (USB) flash drive. This port
also functions as a commissioning Ethernet port
with USB3.0 cable.
The USB port with the CLK silkscreen is used for
multiplexing TOD and test clock.

E1/T1 DB26 female The port is used for four E1/T1 signal inputs and
connector outputs between the UMPT and the universal
E1/T1 lightning protection unit (UELP) or between
the UMPT and the base station controller.

GPS SMA connector The port is used for transmitting radio frequency
(RF) signals received from the antenna to the
satellite receiver.

CI SFP connector The port is used for BBU interconnection.

RST - This port is used to reset the board.

2023-06-25 Huawei Proprietary - Restricted Distribution Page13, Total13