You are on page 1of 5
‘Jl. Kaji No. 6 Kelurahan Petojo Utara, Kecamatan Gambir Jakarta Pusat 10130 - Indonesia Telp 6221 - 22638101 (Hunting) Fax: 6221 - 22363152 Email: centra.multi@gmail.com MINUTES OF MEETING PEMBAHASAN SOW SKTT 150KV GANDUL-KEMANG Tanggal : O7 Juni 2022 Tempat : Office PT. CME Nama Jabatan Tanda ype arte Memo Ab\ if Cemyane T Hse CMe G fesuni awene cme —tiy Base Kediwan Crete | i+ Arla Kev i Shasye Cue Ug cS y be |~| % ye ANTAPURA SCOPE OF WORK HORIZONTAL DIRECTIONAL DRILLING 150 kVa GANDUL - KEMANG ‘A__| Drilling Equipment 1 | Drill Rig complete with tools ‘AEl_| CME and AEI OK 2 | Mud Mixing System ‘AEI_| CME and AE! OK 3 | Locating System ‘AEI_| CME and AEI OK B__| Engineering 1__| Existing utility survey and mapping CME CME and AEI OK 2___| Site set out and survey (CME CME and AEI OK 3 | Geotechnical investigation CME (CME and AEI OK 4 | Design and Calculation of HDD crossing CME ‘ANTAPURA will help to assist S| Construction drawings CME ‘CME and AEI OK & | HDD as built drawings (CME | AEl_| ANTAPURA will send boring log and simple drawing ‘and CME will submit the document to PLN (Reporting Format by CME) [ce | Equipment 1 | Excavators (Including Operator) ‘AEI_| CME and AEI OK 2___| Crane for mob, demob and as required ‘AEI_| CME and AE! OK 3 | Fuel storage tank AEL [4 | Transportation for persons ( including Driver) AEL 5 | Pick up trucks (including Driver) ‘Acl_| CME and AE! OK 6 __| Pipeline rollers ‘AEI_| CME and AE! OK 7___| Excavator for pipe lifting and Digging ‘AEI_| CME and AE! OK 8 _| Sheet pile installation assistance for HDD ‘AEI_ | CME and AE! OK work ‘9 | Generator set ‘AEI_| CME and AEI OK 10 | Dump Truck ( Including Operator) ‘AEL_|_CME and AFI OK 11 | Water Pump and hose ‘AEl_| CME and AEI OK 12 [3 Ton Truck Crane (Including Operator) ‘AEI_|_CME and AEI OK 13 | Stone breaker Excavator PC 75 ( Including ‘AEI_| CME and AEIOK Operator) 14 [Lighting and Genset ‘AEL_|_CME and AEI OK 15 _| Safety Suit for Workers ‘AEL_| CME and AEI OK 16 | Work Protection (Water Barrier, Frame Pit | CME Work protection equipment will be used for Test Pit, Protection, Traffic sign, Safety Cone, Safety HOD Process, Tie In, Manual Boring, Install JP, Laying, Light, Etc) Mobilisation and instalation at job Jointing, and re-Instatement that will be done as Scope site. of PT. CME (related to all project activity) D [Man Power 1 | Project Manager ‘AGl_| CME and AEIOK 2___ | Construction Manager ‘AEI_| CME and AEI OK 3. | Safety Man ‘AE! | Safety man will help to report all job site condition to CME 4 | Supervisor ‘AEI_| CME and AEl OK hy Gh ANTAPURA SCOPE OF WORK 5___| Operator and Tracker ‘AEl_| CME and AE! OK 6 | Helpers ‘AEI_| CME and AEI OK = 7__| Security ‘AEL_| ANTAPURA will provide security at site only 8 | Mechanic ‘AEI_| CME and AE! OK 9 __| Traffic Management ME Responsibilities forall project of CME as the Main Contractor (related to all project activity) E__| Materials 1__| Bentonite ‘AEI_| CME and AE! OK 2 | Polimer ‘AEI_| CME and AE! OK 3 | Fitrot ‘AEI_|_CME and AE! OK 4 |StopClay ‘AEl_| CME and AEI OK S| Additive Chemical ‘AEl_| CME and AE! OK 6 | Petrol Fuel ‘Ael_| CME and AE! OK | 7 | Diesel Fuel ‘Agl_| CME and AEI OK 8 __| Fresh water for drilling ‘AEI_| CME and AE! OK 9 | Pulling Heads ‘AEI_| CME and AE! OK 10 | Product pipe string including Joint Shock | CME Regarding to piping work 11 __ | Roding Rope CME Regarding to piping work 12 | Hydraulic Oi ‘Aél_| CME and AEIOK 13 | Engine oi) ‘AEI_|_ CME and AEIOK F | Construction 1 | Locate, identify all existing utilities CME Regarding to CME engineering document to PLN 2 Relocation/reinstatement, if required, of CME | AEI = Regarding to CME engineering document to existing utilities PLN ~ Regarding to AEI section work, AE! will responsible if any damage in property or utility 3 | Workshop Area including warehouse CWE Regarding to all material project and all supporting supervisor activity including mud disposal 4 | Removal of drilling fluid slurry and clean up ‘AEl_| CME and AEI OK site 5 __| Alltransportation, preparation and handling ‘AEL_| CME and AEIOK of the pipe string to be installed by HDD Inclusive of pull back from workshop to jobsite 6 | Repair/reinstate roads and footpaths after | CME Regarding to reinstatement job demob of HDD equipment 7 | Excavate the entry and exit betonies pit and ‘Ael_ | CME and AEIOK test pit & | Pilot, Reaming, Pullback ‘Aei_| CME and AEIOK ‘9 | Welding Pipe and Joint shock ‘Agl_ | Wrapping material by ANTAPURA and Joint Shock by CME 10 | Rope Roding ‘Aei_| CME and AEI OK 11 __| HSSE management and supervision ‘CME | AEI_| CME HSSE supervise ANTAPURA safety man 12 | Transportation, Meal and home stay for ‘Al | CME and AEI OK helpers hh G4 3 3, F bis ‘SCOPE OF WORK ANTAPURA G___[ Administrative 1 | All Government and Local Authority licenses, | CME PTSP, Pemprov, Kabupaten, Kota, Kecamatan, permits, permissions and all required Kelurahan, RW, RT, ORMAS construction permits All work permits for HDD personnel ‘CME (CME and AEIOK 3 jaison Authorities, land, property owners ‘AI | Entry and exit area and local population for entry and exit pit Project Insurance Alll risk and JAMSOSTEK ‘AEI_ | CME and AEI OK according to contract, H [Testing 1___| Cleaning And rooding test after Pullback ‘AEl_| CME and AEI OK I 1 | Facility & Uti 1___| Temporary office CME ‘CME and AEI OK 2___| Mess, Laundry & Accomodation ‘AEI_| CME and AEI OK J __| Technical issue 1 Planning Number of Section CME. [CME and AE! OK 2__| Clay Stone with SPT 60 (CME Hard rock soil if any case happened * mud motor *Tricone drill * Hole opener * Utility & consumable HDD. 3 | Schedule @ 250 M (piloting - pullback) ‘AEl_| CME and AEI OK 4__| Test Laboratory for Mud/Slurry CME ifany requirement by PLN. S| Test Laboratory for Reinstatement Job CME Ifany requirement by PLN. ‘Antapura Energi Indonesi Mae, Ardhana Rizki Patria Director bat PEKERIAAN SKTT 150KV GI GANDUL-- GIS KEMANG @ PLN "TABSL DRAFT PRIANG SPAN HASIJONT SURVEY LAPANGAN wo] san stcnow us NAN a eave room: e__lupmcenan SEMAN A CSE [waa as KOM

You might also like