You are on page 1of 5
Jl. Kaji No. 6 Kelurahan Petojo Utara, Kecamatan Gambir Jakarta Pusat 10130— Indonesia Telp — : 6221 - 22638101 (Hunting) Fax: 6221 - 22363152 Email : centra.multi@gmail.com MINUTES OF MEETING PEMBAHASAN SOW SKTT 150KV GANDUL-KEMANG Tanggal 07 Juni 2022 Tempat + Office PT. CME No Nama Jabatan ! Tanda yen I arpa Mado Agl | if 2 | Ceoybnes 1 He CME %. | desunii AweMe CMe aty Y|parr bediven | Cre Gif S| Ardlhane Rev fain. — G. | Shaye * - CMe | Kp De ANTAPURA SCOPE OF WORK HORIZONTAL DIRECTIONAL DRILLING 150 kVa GANDUL - KEMANG ‘A_| Drilling Equipment 1 | Drill Rig complete with tools ‘AEI_| CME and AEIOK 2 | Mud Mixing System ‘AEl_| CME and AEI OK 3 | Locating System ‘AEI_| CME and AEI OK B_| Engineering Eee 1 | Existing utility survey and mapping CME CME and AEI OK 2__| Site set out and survey CME CME and AEI OK 3 | Geotechnical investigation (CME (CME and AEI OK 4 | Design and Calculation of HDD crossing CME 'ANTAPURA will help to assist S| Construction drawings CME CME and AEI OK © | HDD as built drawings (CME | AEl_| ANTAPURA will send boring log and simple drawing ‘and CME will submit the document to PLN (Reporting Format by CME) © | Equipment 1 | Excavators (including Operator) ‘AE_| CME and AEI OK 2___| Crane for mob, demob and as required ‘AEI_|_CME and AEI OK 3___| Fuel storage tank ‘AEL_| CME and AELOK [4 | Transportation for persons ( including Driver) ‘AEI_|_CME and AEI OK 5 | Pick up trucks (Including Driver) ‘Agl_| CME and AEIOK 6 __| Pipeline rollers ‘AEI_|_CMEand AEI OK 7___ | Excavator for pipe lifting and Digging ‘AEl_| CME and AEI OK 8 | Sheet pile installation assistance for HDD ‘Agl_| CME and AEIOK work S| Generator set ‘AEI_| CME and AEIOK 10 | Dump Truck ( including Operator) ‘AEl_[ CME and AEIOK 11 | Water Pump and hose ‘AEl_| CME and AEI OK 12 [3 Ton Truck Crane (including Operator) [AeI_| CME and AEIOK 13 | Stone breaker Excavator PC 75 ( Including ‘AE | CME and AE! OK Operator) 14 [Lighting and Genset ‘AEI_| CME and AEI OK 15 | Safety Suit for Workers [AEI_| CME and AEIOK 16 | Work Protection (Water Barrier, Frame Pit | CME | Work protection equipment will be used for Test Pit, Protection, Traffic sign, Safety Cone, Safety HDD Process, Tie In,Manual Boring, Install J, Laying, Light, Etc) Mobilisation and instalation at job Jointing, and re-Instatement that will be done as Scope site, ‘of PT. CME (related to all project activity) D | Man Power 1__| Project Manager ‘AEL_| CME and AEIOK 2 | Construction Manager ‘AEl_| CME and AEI OK 3 _| Safety Man ‘AEL_| Safety man will help to report all jobsite condition to CME 4 | Supervisor ‘Agl_[ CME and AEIOK fy GA ANTAPURA, SCOPE OF WORK S| Operator and Tracker ‘AEL_|_CME and AE! OK 6 | Helpers ‘AEL_| CME and AEIOK 7 [Security ‘AEl_| ANTAPURA will provide security at site only 8 | Mechanic ‘AEI_| CME and AE! OK 9 _| Traffic Management CME Responsibilities for all project of CME as the Mai Contractor (related to all project activity) E | Materials 1 | Bentonite ‘AEi_| CME and AEI OK 2 | Polimer ‘Al_| CME and AE! OK 3 | Fitro! ‘AEI_| CME and AEI OK 4 | Stop Clay ‘AEl_| CME and AEI OK 5__| Additive Chemical ‘Agl_| CME and AEI OK 6 | Petrol Fuel ‘AEI_| CME and AEI OK 7 | Diesel Fuel ‘AEI_| CME and AE! OK 8 __| Fresh water for drilling ‘AEl_| CME and AE! OK 9 | Pulling Heads ‘AEI_|_CME and AEI OK 10 | Product pipe string including Joint Shock | CME Regarding to piping work 11 | Roding Rope CME Regarding to piping work 12__| Hydraulic Of ‘AE|_|_CME and AEI OK 13 | Engine oll ‘AE|_| CME and AEI OK [F | Construction 1 Locate, identi CME ‘Regarding to CME engineering document to PLN 2 Relocation/reinstatement, if required, of CME | AEI | - Regarding to CME engineering document to existing utilities PLN = Regarding to AEI section work, AE! will responsible if any damage in property or utility 3 | Workshop Area including warehouse CME Regarding to all material project and all supporting supervisor activity including mud disposal Ht 4 | Removal of driling fluid slurry and clean up ‘AE | CME and AEI OK site 5 | Alltransportation, preparation and handling ‘AEl_[ CME and AEIOK of the pipe string to be installed by HDD inclusive of pull back from workshop to Jobsite | Repair/reinstate roads and footpaths after | CME Regarding to reinstatement job demob of HDD equipment 7 | Excavate the entry and exit betonies pit and ‘AéI_| CME and AEI OK test pit 3 | Pilot, Reaming, Pullback ‘Ael_| CME and AEIOK 9 | Welding Pipe and Joint shock ‘AEI_| Wrapping material by ANTAPURA and Joint Shock by | CME 10 | Rope Roding ‘AEL_| CME and AEI OK 11 | HSSE management and supervision CME_| AEI_| CME HSSE supervise ANTAPURA safety man 12 | Transportation, Meal and home stay for ‘AEl_ | CME and AEI OK helpers + Gt SCOPE OF WORK G__ [Administrative 1 AllGovernment and Local Authority licenses, | CME PISP, Pemprov, Kabupaten, Kota, Kecamatan, permits, permissions and all required Kelurahan, RW, RT, ORMAS construction permits 2 |All work permits for HDD personnel CME CME and AEIOK 3 | Liaison Authorities, land, property owners ‘AEI_| Entry and exit area and local population for entry andexit pit | 4 | Project insurance All risk and JAMSOSTEK ‘AE | CME and AEIOK according to contract H__| Testing 1__| Cleaning And rooding test after Pullback ‘AE\_| CME and AE! OK H Facility & Utility 1__| Temporary office CME ‘CME and AEI OK 2__| Mess, Laundry & Accomodation ‘AEL_| CME and AE! OK J __[ Technical issue 1__| Planning Number of Section CME ‘CME and AEI OK 2 | Clay Stone with SPT 60 (CME Hard rock soil if any case happened * mud motor = Tricone drill * Hole opener * Utility & consumable HDD. 3____| Schedule @ 2250 M (piloting - pullback) ‘AEl_| CME and AEI OK 4__| Test Laboratory for Mud/Slurry CME ifany requirement by PLN. S| Test Laboratory for Reinstatement Job ‘CME Ifany requirement by PLN Antapura Ener \ oe Ardhana Rizki Patria Director Lh PEKERIAAN SKTT 250KV GI GANDUL-- Gis KEMANG & PLN "95 ORF PANG AN HAS ODT SURVEY PANGAN oi seven Pant ima ERA ‘ean fons Ivara as Iuvnncrnno pean SE tg

You might also like