You are on page 1of 15

The National BIM Library

BIM Object Guide: Sapa Building Systems Ltd

The National BIM Library


BIM Object Guide: Dualframe 75 mm HP Entrance Door - Single

Version 1.0

5th March 2013

www.nationalBIMlibrary.com

Version 1.0 5th March 2013 Page 1 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

Contents
1.0 Introduction ..................................................................................................................... 3

1.1 Naming ........................................................................................................................ 3

2.0 Parameters ..................................................................................................................... 5

2.1 National BIM Library Parameters ................................................................................. 5

2.2 NBS Parameters.......................................................................................................... 6

2.3 Manufacturers Parameters .......................................................................................... 8

2.4 IFC Parameters ........................................................................................................... 9

2.5 COBie Parameters .................................................................................................... 12

3.0 Abbreviations ................................................................................................................ 15

Version 1.0 5th March 2013 Page 2 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

1.0 Introduction

This guide covers the use of Dualframe 75 mm HP Entrance Door included within the
National BIM Library.

Dualframe 75 mm HP Entrance Door - Single

All products listed below are included in the following file:


nbl_DrsetSym_SapaBuildingSystems_Dualframe75mmHPEntranceDoor-Single

Dualframe 75 mm HP Entrance Door – 1000 x 2100mm

Version 1.0 5th March 2013 Page 3 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

1.1 Naming

National BIM Library objects are named to identify their type and configuration. Fields are
segregated using an under bar (_) and information within each field is segregated using
hyphens (-). Fields are abbreviated to reduce characters and capitals used at the start of
each abbreviation to aid readability.

File name and objects are named as below:

File name
Field1 Author_Field2 Category_Field3 Manufacturer_Field4 Product Range

Object
Field1 Author_ Field2 Category Field3 Manufacturer_Field4 Product_Field5 Differentiator

Version 1.0 5th March 2013 Page 4 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

2.0 Parameters

Parameters included in the Dualframe 75 mm HP Entrance Door BIM object are as


follows:

2.1 National BIM Library Parameters

Author The name of the BIM objects Author.

BIMObjectName Name of the BIM object as it will appear in software. Using


NBL naming procedure.

Description The full description of a product or system.

Help URL of a website where additional help notes are available.

IssueDate The issue date of this BIM object.

ManufacturerURL URL of the product or system manufacturer.

NBSDescription NBS Uniclass title.

NBSNote Where a second system which is related to the BIM object can
be described.

NBSReference NBS Uniclass section/clause number.

NBSTypeID A reference to the object for the user if one or more is used
within the project.

Uniclass2 Uniclass2 code.

Version The version number of the BIM object.

Version 1.0 5th March 2013 Page 5 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

2.2 NBS Parameters

AdditionalHardware Additional hardware that is not part of the doorset


system.

AdditionalHardwareOptions Available hardware options.

AlternativeDoorsetGlazing Glazing specification if not part of the doorset system


and it is to be installed on site or in joiner's shop.

AntiFingerTrapRequirement Indication whether there is a requirement for an anti-


finger trap.

BreakoutFacility Indication if doors can be opened manually in an


emergency.

ComponentNumber Project component number reference.

Configuration Doorset arrangement indicating number of door


leaves and operation.

DoorNumber Project door number.

DoorSeal Indication if a door seal is required to prevent or


reduce penetration of weather, fire/smoke, sound or
light.

DoorsetFasteners Type of door fasteners used during installation.

DoorsetType Doorset type according to principal material.

ElectronicLock Indication whether an electronic lock is required.

FloorFinish Floor finish to doorset location.

FrameFinish Door frame finish.

FrameMaterial Door frame make-up where there are product


options.

FrameRevealFiller Intumescent material used in cavities to prevent


spread of fire/smoke or weatherproofing compounds.

FrameSeal Indication if a frame seal is required to prevent or


reduce penetration of weather, fire/smoke, sound or
light.

Version 1.0 5th March 2013 Page 6 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

Handing Doorset handing.

HardwareSet Essential hardware supplied with doorset.

HeadDetail Referenced head drawing number.

HoldOpen Indication whether a hold open arm is required.

JambDetail Referenced jamb drawing number.

KeySuiting Key suiting reference.

LeafFacing Indication of door leaf finish.

LeafSwing Directional swing.

OpeningMechanism Indication whether there is a requirement for an


opening mechanism.

OverPanels Requirement for an overpanel which is not part of


the door system.

SidePanels Requirement for a side panel which is not part of the


door system.

SignageFire Fire signage requirement.

SignageSecurity Security signage requirement.

SignageWayfinding Way finding signage requirement.

SystemAccessories Additional items which do not come as integral parts


of the doorset system.

SystemAccessoryOptions Available accessory options.

ThresholdBase Threshold type if not part of the door system.

ThresholdStripping Indication if a threshold stripping is required to


prevent weather, fire/smoke, sound or light that is
not part of the doorset system.

Trim Indication of trim used as cloaking or for any other


detail.

Version 1.0 5th March 2013 Page 7 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

2.3 Manufacturers Parameters

AirPermeability Performance classification according to BS 6375-1.

ExposureCategory Performance according to BS 6375-1.

FrameFinishOptions Available finish options.

FrameOptions Available frame options.

GlassUnitOptions Available glazing options.

GlazingBeadOptions Available beading options.

GlazingBeadPositioning Indication whether glazing bead is internal or


external.
GlazingUnit Glazing specification.

MaximumLeafWeight Maximum weight measured in [kg].

SillOptions Available sill options.

ThermalBarrier Thermal barrier specification.

WaterTightness Performance classification according to BS 6375-1.

WindResistance Performance classification according to BS 6375-1.

Version 1.0 5th March 2013 Page 8 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

2.4 IFC Parameters

Note: IFC definitions have been obtained from BuildingSmart IFC2x3 website
(http://buildingsmart-tech.org).

AcousticRating Acoustic rating for this object. It is provided


according to the national building code. It indicates
the sound transmission resistance of this object by
an index ratio (instead of providing full sound
absorption values).

BeamRadiationTransmittance Direct solar radiation transmittance that passes the


glazing at normal incidence. It is a value without unit,
often referred to as (Tsol).

FillGas Name of the gas by which the gap between two


glass layers is filled. It is given for information
purposes only.

FireExit Indication whether this object is designed to serve as


an exit in the case of fire (TRUE) or not (FALSE).
Here it defines an exit door in accordance to the
national building code.

FireRating Fire rating for this object. It is given according to the


national fire safety classification.

GlassColour Colour (tint) selection for this glazing. It is given for


information purposes only.

GlassLayers Number of glass layers within the frame. E.g. "2" for
double glazing.

GlassThickness1 Thickness of the first (inner) glass layer.

GlassThickness2 Thickness of the second (intermediate or outer)


glass layer.

GlassThickness3 Thickness of the third (outer) glass layer.

GlazingAreaFraction Fraction of the glazing area relative to the total area


of the filling element. It shall be used, if the glazing
area is not given separately for all panels within the
filling element.

Version 1.0 5th March 2013 Page 9 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

HandicapAccessible Indication that this object is designed to be


accessible by the handicapped. It is giving according
to the requirements of the national building code.

HasDrive Indication whether this object has an automatic drive


to operate it (TRUE) or no drive (FALSE).

Infiltration Infiltration flowrate of outside air for the filler object


based on the area of the filler object at a pressure
level of 50 Pascals. It shall be used, if the length of
all joints is unknown.

IsCoated Indication whether the glass is coated with a material


(TRUE) or not (FALSE).

IsExternal Indication whether the element is designed for use in


the exterior (TRUE) or not (FALSE). If (TRUE) it is
an external element and faces the outside of the
building.

IsLaminated Indication whether the glass is tempered (TRUE) or


not (FALSE).

IsWired Indication whether the glass includes a contained


wire mesh to prevent break-in (TRUE) or not
(FALSE).
Reference Reference ID for this specified type in this project
(e.g. type A-1), provided, if there is no classification
reference to a recognized classification system used.

Reflectivity Fraction of the visible light that is reflected by the


glazing at normal incidence. It is a value without unit.

SecurityRating Index based rating system indicating security level. It


is giving according to the national building code.

SelfClosing Indication whether this object is designed to close


automatically after use (TRUE) or not (FALSE).

SmokeStop Indication whether the object is designed to provide


a smoke stop (TRUE) or not (FALSE).

SolarHeatGainTransmittance Thermal transmittance coefficient (U-Value) of a


material. Summer thermal transmittance coefficient
of the glazing only, often referred to as (U-value).

Version 1.0 5th March 2013 Page 10 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

ThermalTransmittance Thermal transmittance coefficient (U-Value) of a


material. It applies to the total door construction.

ThermalTransmittanceSummer Thermal transmittance coefficient (U-Value) of a


material. Summer thermal transmittance coefficient
of the glazing only, often referred to as (U-value).

Version 1.0 5th March 2013 Page 11 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

2.5 COBie Parameters

The following COBie parameters have been included within the Dualframe 75 mm HP
Entrance Door BIM object and can be used to prepare COBie data schedules:

AccessibilityPerformance Accessibility issue(s) which the product satisfies.

AssetIdentifier The asset identifier assigned to an occurrence of a


product (prior to handover).

BarCode The identity of the bar code (or rfid) given to an


occurrence of the product.

CodePerformance Code Compliance requirement(s) which the product


satisfies.

Colour Characteristic or primary colour of product.

Constituents Optional constituent features, parts or finishes.

Cost Cost impact of replacement process.

Documentation Location (Uniform Resource Information) for further


product information.

DocumentReference Location (Uniform Resource Information) for the


source or updates to this product information.

Features Features or other important characteristics relevant


to product specification.

Finish Characteristic or primary finish of product.

Grade Standard grading(s) to which the product


corresponds.

InstallationDate The date that the manufactured item was installed.

LifeCyclePhase Life Cycle Phase as defined in ISO 15978.

Manufacturer The organization that manufactured or assembled


the item.

Material Main material of the covering.

Version 1.0 5th March 2013 Page 12 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

MethodOfMeasurement Method of measurement.

ModelLabel The model number assigned by manufacturer.

ModelReference The name used by the manufacturer.

NominalHeight Nominal height of product, typically the vertical or


secondary characteristic dimension.

NominalLength Nominal length of product, typically the larger or


primary horizontal dimension.

NominalWidth Nominal width of product, typically the characteristic


or secondary horizontal or characteristic dimension.

Process Specification of process.

ProductionYear The year of production for the manufactured item.

ReferenceStandard Reference standard(s) to which the product is


compliant.

ReplacementCost An indicative cost for unit replacement.

SerialNumber The serial number assigned to an occurrence of a


product by the manufacturer.

ServiceLifeDuration The length or duration of a service life.

ServiceLifeType The typical service life that is quoted for an artefact


under reference operating conditions.

Shape Characteristic shape of product.

Size Characteristic size of product.

SustainabilityPerformance Sustainability issue(s) which the product satisfies.

TagNumber The tag number assigned to an occurrence of a


product.

WarrantyDescription Description of the warranty.

WarrantyDurationLabour Duration of labour warranty (years).

WarrantyDurationParts Duration of parts warranty (years).

Version 1.0 5th March 2013 Page 13 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

WarrantyGuarantorLabour Organization acting as guarantor of labour warranty.

WarrantyGuarantorParts Organization acting as guarantor of parts warranty.

WarrantyStartDate The date on which the warranty commences.

Version 1.0 5th March 2013 Page 14 of 15


The National BIM Library
BIM Object Guide: Sapa Building Systems Ltd

3.0 Abbreviations

Drset Doorset
nbl national BIM library
Sym System

Version 1.0 5th March 2013 Page 15 of 15