Professional Documents
Culture Documents
Standard Features
Low-pressure high-output lamps (LPHO) Available Options
Lamp statusindicator UV Monitoring Package: UV intensity reading with
System hours of operation NIST certified sensor
Lamp out alert (LOA) Control Panel: UL Type 4X or UL Type 12
Remote start/stop(HOA) Control Panel: Sloped Top
304 stainless steel control cabinet 4-20mA output signal with UV monitoring option
316L stainless steel treatment chamber Viton Elastomers
Ra 32 internal surface finish Ra 15 internal surfacefinish
EPDM Elastomers
Minimum Water Quality Requirements
Fe count is less than: 0.3 mg/l TH level is less than 10 grains per gallon
H2S count is less than: 0.05 mg/l Turbidity is less than 1NTU
TSS count is less than: 10 mg/l Tanning is less than 0.1mg/l
Mn count is less than: 0.05 mg/l
Industrial UV Sterilizers UVI
SERIES
Capacity: 12 to 1,380 GPM
Advantages of UV
Effective: Virtually all microorganisms are susceptible to UV disinfection
Economical: Hundreds of gallons of water can be purified for a few cents per day
Specifications UV- UV- UV- UV- UV- UV- UV- UV- UV- UV- UV- UV- UV- UV- UV- UV-
12 33 60 90 125 175 248 338 492 553 664 793 909 1095 1292 1380
Flow Rate (gpm ) 12 33 60 90 125 175 248 338 492 553 664 793 909 1095 1292 1380
Num ber of UV lamps 1 3 2 2 4 4 4 4 6 8 8 8 8 10 12 12
Material of
316L Stainless Steel
Treatment Chamber
Construction
Lam p Length -
inch
15 15 30 30 30 30 60 60 60 60 60 60 60 60 60 60
Chamber diameter
6 6 6 8 6 8 6 8 8 8 10 12 14 14 14 16
- inch
ANSI flanges size-
2 2 2 4 4 4 4 6 6 6 8 8 8 8 8 10
inch
Shipping W eight (Lbs.) 125 170 267 267 400 534 670 770 820 950 1150 1250 1350 1450 1450 1450
Electrical
Power
Consumption ( W )
173 274 265 265 407 407 693 693 1548 1833 1833 1833 1833 2118 2403 2403
Maximum water
operating tem - 40º-104º (5º-40º)
Conditions
Operatin
perature F (C°)
Maximum Operat-
ing Pressure PSI 150 (10)
g
(BAR)
Surface Finish Ra32
Elastomers EPDM
Material of
3 0 4 Stainless Steel
Construction
UL Type 12 (IP54) with
Rating UL Type 1 (IP50)
Fan
Control Panel
Note: system designed based on 94% UVT, Dose Level: 30 mJ/cm 2 after 9,000 hours of operation.
Authorized Dealer:
Water & Ice process solution