Operating instructions
Features
-Feeder operating frequency is adjustable and independent of mains frequency.
-Constant feed rate ensured by internal compensation, irrespective of mains
fluctuations.
-Integrated track control via backlog sensor.
-24 V DC output for operating an air valve (IP 54 version), and amplitude control
(sensor required).
-Independent resonant frequency search possible for feeder.
-Enable input (start / stop), status relay (output active / inactive).
-Stand-alone housings (IP 54) or panel-mounted units (IP 20).
Technical data:
Supply voltage 110 / 240 V, +/- 10%, 50/60 Hz
Output 0...100 / 0... 205 V, 3 A, 6 A, 8 A, 12A, 16A
Output frequency 5...300 Hz, (preset at 35... 140 Hz)
Enable input Contacts or 24 V, DC
MFS 268XXL 16A Track sensor 24 V, PNP (100 mA)
MFS 268XL 12A
ID# 626887 Solenoid air valve output 24 V, (150 mA)
ID# 626867
MFS 268 IP20 16A Status output relay (ON/OFF) Changeover contact (250 V, 1 A)
Operating temperature 0...+45 °C
ID# 621103
Storage temperature -10...+80 °C
Recommended fuse 3 A, 8 A, 16 A slow-blowing, Type 'D' MCB
Decrease value All adjustments are made by first pressing the P key, followed by Track full
selecting the menu code, using the cursor keys.
F Return Settings Setpoint in %
Programming mode Pressing the cursor key for a short time causes one digit Timer running
I P increase/decrease, holding down for a longer time gives changes in
F or Enter
Controller Output ten-digit steps. Stop using "0" key
I
P 0 ON Changed settings are saved when exiting the menu or automatically
Controller Output if a key is not pressed for 60 seconds.
0
OFF
No code number is required to change the feed rate: pressing the P key twice will call the setpoint display.
2
Safety instructions
This description contains the necessary information for the correct application of the product described below. It is intended for use by technically qualified personnel.
Qualified personnel are persons who, because of their training, experience and position, as well as their knowledge of appropriate standards, regulations, health and
safety requirements and working conditions, are authorised to be responsible for the safety of the equipment, at all times, whilst carrying out their normal duties and are
therefore aware of, and can report possible hazards (definition of qualified employees according to IEC 364).
Installation
Do supply voltage, operating voltage of the conveyor and controller input voltage match ?
Is the controller adequately rated for the rated power of the feeder ?
What is the vibrating frequency of the feeder ?
During switch-on, internal capacitors cause a high inrush current. Especially if several controllers are switched on simultaneously, the
external fuse can blow or the circuit breaker can trip. Therefore, we recommend fitting slow-acting fuses or circuit breakers, e.g. with type 'D'
characteristic.
Connect the unit in accordance with the wiring instructions and ensure that earthing is correct !
If an external setpoint source is used, select "E.S.P." = I in Menu C003. If a potentiometer is used, select also 'Pot.' = I.
To set the minimum vibration level, select E.S.P. = 0, adjust the vibration level with the cursor keys and then set E.S.P. = I.
The specific settings for a system can be saved by selecting 'US.PA.' in Menu C143 (recall settings via Menu C 210 'US.PA').
Menu access can be hidden by selecting 'Hd.C.' = I in Menu C117.
3
Code 003 Function settings Display 0...+10 V 0(4)...20mA Potentiometer .
7 8 9
-
7 8 9
7 8 9
P 0...+10 V,
+ 10 kR
+ 0(4)...20 mA
+5 V Potentiometer 10 KW
0 = Setpoint using display 500R
P
I = external setpoint 0...+10 V ON Sensor input
+24 V Sensor +24 V Track control
0 = external setpoint 0...+10 V or
P 0 0
Sensor input
I = external setpoint 4...20 mA Coarse / fine control with
a [mm] Feed rate two feed rates
a [mm]
0 = 0...10 V/ 0(4)...20 mA
P Feed rate
I = Potentiometer
0 = Track control via backlog sensor t t
P I = Coarse/fine control with second setpoint t-on t-off
Track control / backlog Coarse / fine control
P
0 = Enable
I = Invert enable Enable Enable
+24 V signal or
+24 V +24 V
closed contact will
Enable input
Operating mode enable the output.
0 t 0 t
+24 V signal or
a [mm] a [mm]
Feed rate Feed rate closed contact will inhibit
the output.
0 t 0 t
P. 100%
100 %
The set point will still
Amplitude
Feed rate display 0... 100 %, even
P Feed rate 0...100 % 0 Setpoint though it is limited
100 % internally.
Vibrating frequency
Vibrating frequency [Hz] The frequency setting
P
depends on the feeder
type.
Important!
P Soft start time 0...5 sec.
The wrong frequency
setting can damage the
coil.
P Soft stop time 0...5 sec.
a [mm]
4
Code 008 Control mode
a [mm] Limiting of output voltage
P. 80% P. 100% Maximum
100 % a [mm]
or feed rate, e.g. to
Amplitude
P prevent hammering. The
100 %
displayed setpoint range
Amplitude
Feed rate Feed rate
remains at 0...100%.
P Feed rate 0...100 % 0 Setpoint 100 % t
0 Setpoint 100 % 100 % t
P Maximum limit 100...5 %
Frequency setting
depends upon the feeder
P Vibrating frequency [Hz] type.
Operating mode t
Automatic frequency
f = fixed f = f resonant change in case of
resonance.
* An acceleration sensor, type SW-70, has to be fitted to the feeder for constant amplitude control. Care must be taken in the method of mounting to ensure
that the fixtures are solid, provide the correct orientation and do not flex under vibration.
Time delays
0 0
P
Feeder
a [mm] a [mm]
ON Feeder OFF
P Switch on time delay
0...60 sec.
t t
Switch off time delay t-on t-off
P
0...60 sec.
Sensor
P Invert sensor function 24V Sensor 24V
I = inverted 0 0
t t
Operating mode
Sensor control
0 detected during the
inactive Feeder ON
0 = Feeder doesn't switch off during timeout a [mm] timeout period, the
P
I =Feeder switches off during timeout active t-on feeder switches off.
t
P E. = Sensor timeout [sec]
P
0 = Pulse feed Off
I = Pulse feed On
Pulse feed
P Feeder off time
0 t
Operating mode
6
Code 117 Inhibit access
P P
Parameter menus cannot be accessed, except for the feed rate setpoint Hide programming
I= Hidden menus menus.
P P
Parameter menus can be accessed
P Operating mode
P P
P Operating mode
Service
P P
P P
Save parameter settings All previously set parameters are saved.
P Operating mode
P P
P Operating mode
7
Code 127 Enable service menu
Code 008
P P
Service
Extended
P P
0 = Service mode OFF Fmin / Fmax, and Output voltage limiting. settings
I = Service mode ON
P Service mode
Current limit
Current limit in % of Imax. Adjusting output current
P P
llimit depending on coil.
Adjustment of the current limit I-limit x 100 4,8 x 100
= = 80 %
in & of the nominal current (Inom). Inom 6
P P Lower frequency limit
5 Hz 300 Hz
Setting the limits of the
Adjustable frequency range F.L. F.H.
Frequency range
frequency adjustment
P P Upper frequency limit Parameters 'F.L.' and 'F.H.'
range accessible for the
in Menu C 040.
user.
Actual frequency value max. 1 : 4 A narrow adjustment
P P
Effective frequency range range is preferable for
(display only) Parameter 'F' in the automatic frequency
Menus C 008, C 096, and C 020. search function.
Output voltage F.L. F.H.
P P limiting 100 V
0 = Off, I = On
Monitoring the
Display shows the actual vibration frequency. vibration frequency
P Operating mode
When operated with 230 / 240 V mains supply, the output voltage is limited to 100 V.
8
MFS 268, 621605, 3Amp, IP 20
F I
P O
REOVIB
MFS
9
MFS 268, 626848, 8Amp, IP 20
REO - USA
F I
P O
10
MFS 268, 621103, 15Amp, IP 20
REO - USA
F I
P O
11
MFS 268, 3Amp & 8Amp, IP 20, Electrical
1
Track Sensor E
2
3
+24V
- USA
4
4
Enable +
5
5
12...24V, DC
6
- E A
7 - 7
7
0(4)...20mA 0...10V S
Set point + 8 + 8 10k
8
9 10
+10V
F I
black GND
31 32 33 34
Accelerometer SW... orange E
+ 24V
P 0
red
SPEED
P P P
21
Status Relay
22
23
24
Feeder
25
26
L
27
N
Main Input PE
28
29
PE
12
MFS 268, 15Amp, IP 20, Electrical
USA
26
L
Main Input
27
N
28
PE
29
PE
F I
1
Track Sensor E
2
3
+24V
-
P 0
4
4
Enable +
5
5
12...24V, DC SPEED
6
- E A
7 - 7 P P P
7
0(4)...20mA 0...10V S
Set point + 8 10k
8
+ 9
9 10 31 32 33 21 22 23
+10V
black
GND
Accelerometer SW... orange
E
red
+ 24V
Screen clamb
for cable from
acceleration sensor
Feeder
Output
24
25
29
13
MFS 268, 626848, 8Amp, IP 54
14
MFS 268, 626867, 12Amp, IP 54
6.314 8.200
REO - USA
REOVIB MFS 268
F I
P O
7.598 8.071
Key Functions:
F = Former Menu
P = Pass/Accept
= Increase DISCONNECT MAIN SUPPLY
= Decrease BEFORE REMOVING COVER
I = Run
O = Stop
www.reo-usa.com
15
MFS 268, 626887, 16Amp, IP 54
7.125 8.000
F I
P O
7.563 8.062
Key Functions:
F = Former Menu
P = Pass/Accept
= Increase DISCONNECT MAIN SUPPLY
= Decrease BEFORE REMOVING COVER
I = Run
O = Stop
www.reo-usa.com
7.875
16
1
MFS 268, IP 54, 8A, Electrical
2 2 1
+24V PNP-sensor
3
4
-
X4 3 4 3 GND
4
+ Enable 4 Input
3 4
5
5
12...24V, DC
6
10k
- - 0(4)...20mA
7
7 7
A S E + + R=500 ohm
+10V 8 8
8
sensor 2 Input
External set point 3
X 40 3 4 GND 3 4
4
5pol.Flanschdose
31 32 33 34
Acceleration
SW...
+24 V sensor +Schwingweite
Output
A1 brown / A1
blue A2
21
Output Feeder
26
Buchsenein-
satz 4+PE L brown / A1
PE PE
28
blue N
PE
/ A2
29
ye/gn
17
MFS 268, IP 54, 12A & 16A, Electrical
Acceleration 2 1 1 + 24 V Track control 2 1 1 + 24 V, DC
sensor 2 Input 2
3
PNP-sensor
X 40 3 4 GND
X4 3 4 3 GND
4 4 Input
2 1 2 1
3 4 3 4
Internal status relay
22 23
5pol.Flanschdose
+Schwingweite
21
PE PE PE PE PE
Time out +24V
35 36 37
51
Valve + 24V
54 53 52
GND
55
31 32 33 34
Buchsenein-
satz 4+PE Buchsenein-
+24 V Acceleration satz 4+PE
SW...
sensor
PE PE
28
29
0...10V + + 0(4)...20mA
8
7
24
A2 A1
A E Output
6
12...24V, DC
25
5
+ feeder
5
- Enable
4
4
Main
26
N
3
+24V
input
27
110 / 240 V
1
Input Output
L Buchsenein-
brown / A1 satz 4+PE A1 brown / A1
blue N
blue A2
/ A2
/ A2
ye/gn ye/gn
screen
18