FLEX-FLASH UN HYDROFLEX 30 OR OTHER APPROVED PROTECTION ST. STL. BAND CLAMP ST. STL. BAND CLAMP 1 Yo FLEX-FLASH UN r—} H HYDROFLEX 30 OR OTHER APPROVED PROTECTION MONOLITHIC PIPEVENT Li NOTES: ABOVE SUBSTRATE, MEMBRANE 6125-FR 0 C 6° Mi IN MONOLITHIC (SEE NOTE 4) MEMBRANE 6125-FR EPOXY GROUT 4. PENETRATION MUST BE PROPERLY SECURED TO STRUCTURE TO PREVENT VERTICAL OR LATERAL MOVEMENT. EXPOSED DECK CLAMPS ARE NOT APPROPRIATE. 2, SOME PIPE MATERIALS (PVC, COPPER, BRASS) MAY REQUIRE ROUGHENINGISANDING, IN ADDITION TO WIPING WISURFACE CONDITIONER FOR PROPER ADHESION OF MM6125. METAL, PIPES MUST BE FREE OF ALL OIL AND RUST. 3. THE SAME DETAILING ABOVE WOULD BE EMPLOYED FOR PENETRATIONS THROUGH \VERTICALIFOUNDATION WALL APPLICATIONS. 4, INCOVERED/BURIED CONDITIONS, THE FLASHING DETAIL SHOULD EXTENDED AS HIGH AS POSSIBLE. FLASHING MUST BE TERMINATED AT OVERBURDEN LEVEL AND NO LESS THAN 6” Bea HYDROTECH _] 6125-FR {e Ue eh porte acpi cea och es ef Monolithic Membrane AMERICAN H¥YDROTECH, INC. TYP. ROUND PENETRATIONS (PIPE, CONDUIT, ETC.) SCALE: NONE DATE: 11/01/17