Comen air compressor is

equipped with easy-observing


pressure gauge, which offers
better operation experience for
clinicians.

NV8
Neonatal Ventilator

Dual - CPU Intelligent Warning System: Built- in lithium battery provides up


Monitoring with higher Double confirmation when to four hours of working time,
efficiency setting key parameters ensuring no interruption during
power failure and transportation

0197

Shenzhen Comen Medical Instruments Co., Ltd.


Add: Floor 10, Floor 11 and Section C of Floor 12 of Building 1A &Floor 1 to Floor 5
of Building 2, FIYTA Timepiece Building, Nanhuan Avenue, Matian Sub-district,
Guangming District, Shenzhen, Guangdong, 518106,P.R. China
Tel:+86-755-2640 8879 Fax:+86-755-2643 1232 Website: en.comen.com E-mail: info@szcomen.com

P/N:EN-NV8-8P-20210602-V1.4
Nasal Continuous Positive Airway Pressure
For most of the premature infants, their respiratory system is under
Paw Apnea wakeup development. This will lead to irregular breath and apnea.
If not handled properly and timely, it will influence infants’brain
development. And in some severe cases, apnea will threaten infants’lives.

Apnea rescue function


Babies often suck their abdomens in and out while breathing, a pattern
called abdominal breathing.
NCPAP Waveform Comen invented a particular apnea rescue system consisting of a
(with apneawakeup signal display) abdominal breathing sensor, which will monitor the infants’respiratory
conditions all the time. And NV8 will give infant a strong air flow which
is higher than CPAP when apnea happened.

Paw
Nasal Intermittent Positive Pressure Ventilation
NIPPV mode can provide PIP which is higher airway pressure, and PEEP
which is relatively low airway pressure in setting frequency.
Compared with NCPAP mode, NIPPV mode can produce higher mean
airway pressure.
It will benefit the infant’s oxygenation and ventilation, reduce infant’s work
of breathing (WOB), and increase functional residual capacity (FRC).
NIPPV Waveform

Synchronized Nasal Intermittent Positive Pressure Ventilation


Paw
With breath sensors and special algorithm, NV8 can provide synchronized
ventilation, which is more comfortable, and benefits infant’s respiratory
system development. In case of the breath signal loss caused by apnea,

Comprehensive NV8 also has a back-up ventilation function.

Ventillation Modes
The system will switch to preset ventilation mode when an infant’s
breathing is not detected.

SNIPPV Waveform
Comen NV8 is equipped with various ventilation modes (with synchronously triggered signal display)
(including SNIPPV NIPPV NCPAP and HFNC), which enable
precise and suitable ventilation for a patient’s different stages.
Features with apnea rescue function, NV8 can handle with
infant’s apnea risk, relieving the heavy workload of clinicians.
With iFlow closed-loop pressure control system and automatic
Paw
leakage compensation system, NV8 can realize precise flow and High Flow Nasal Cannula
pressure control even in high flow ventilation. Compared with traditional oxygen therapy ventilators, NV8 features with
NV8 is designed to provide user-friendly operation experience pressure monitoring function. By this, doctors can monitor and adjust the
increase the efficiency of medical staff. infant’s airway pressure in real-time. This feature will greatly reduce the
risk of high airway pressure, which always leads to respiratory
system harm to infants.
HFNC Waveform

01
Pressure generator

Precise Pressure Setting Precise O2 Concentration Control

Traditional CPAP device produces certain Traditional CPAP device mixes O2 and
pressure by adjusting flow rate manually. medical air mechanically, while NV9 NV8 system Traditional CPAP device
Unlike traditional CPAP device, NV8 reaches adopts digital O2/Air blender. NV9 will
to and maintains target pressure with help of automatically adjust the ratio of O2
airway pressure airway pressure
real-time near nose pressure monitoring as and Air with the help of built-in flow
well as automatic pressure compensation, sensor and flow valve, and reach to
which greatly reduces the workload of the target O2 concentration.
caregiver.

The most stable respiratory waveform

Special design airway. Multi-size soft silicone


Near-nose pressure It can help to reduce CO2 nasal plugs, nasal masks
monitoring retention & WOB. and cotton bon-nets are
provided, which can be
k

rea

used for premature infants


ac
db

l-ti

weighing as low as 500g.


ee

m
ef

em
tim

on
al-

ito
re

rin
g

iFlow

Flow control
Patient
module
Near-nose pressure
monitoring:
In NV8, the airway
pressure is measured at
closed-loop adjustment the near-nose end which
will provide more
accurate monitoring
of the airway
pressure.

iFlow closed-loop pressure control system:

In NV8, sensors will keep monitoring the airway pressure near the infant’s nose. The data will be feedbacked to
CPU for closed-loop adjustment.
By this system, NV8 can compensate for the leaking gas and guarantee stable pressure ventilation.

02 03
User-friendly Design

8”touch screen with angle for easy observation.

Oxygen Concentration Power-on Self-test LED Back Lit Touch Screen


Calibration

Oxygen Concentration Calibration: With the POST function, NV8 can 8”LED touch screen,
With special structure design, remind the clinicians timely when Easy to operate and observe.
Comen NV8 can conduct oxygen there is any problem with the
concentration calibration during the machine.
ventilation.

Handle with skin-friendly material:


Easy and comfortable to grip.

Safe and Reliable

The trolley is made of aluminum alloy, light and strong.


Besides, this structure specially designed for Comen air
compressors can significantly reduce the noise caused
by resonance.
360° visible alarm light design:
Provide visible alarm wherever
clinicians are.

04