You are on page 1of 1

Performance Study

No.: 22-015A

12%
Reduction in
energy consumption

50%
Commodity Technology Application Reduction in
Copper and Molybdenum REFLUX™ Flotation Cell Flotation Rougher and footprint
Cleaner Circuits

Study type Country


Site Pilot Tests Australia and North America
CO2

How a single REFLUX™ 60%


Reduction in

Flotation Cell could replace CO2e

up to 10 conventional
flotation cells
5-8%
Pilot testing of the REFLUX™ rougher flotation product. Flotation volume Improved
could therefore be reduced by up to tenfold recovery
Flotation Cell (RFC) in copper
compared to conventional rougher systems,
and molybdenum applications translating into substantially lower CAPEX.
has demonstrated the potential
to reduce energy consumption RFC systems also do not require direct
power input, since power consumption is
by 60%, CO2e emissions by 60%,
limited to transfer pumping of slurry and
and plant footprint by 50%,
compared to traditional
wash water. This delivered a power saving
ranging up to 60% with consequent savings
10%
Increase in
mechanical flotation cells. in CO2e emissions.
throughput
The technology also delivered A second pilot-scale test took place at a
significant process benefits that North American molybdenum mine, where
result in improved recovery a slipstream of second column feed was
Copyright © 2022 FLSmidth A/S.
and throughput. treated in the RFC unit. The RFC proved All Rights Reserved. FLSmidth is a
capable of achieving target grade of 51.5% (registered trademark) of FLSmidth A/S.
Mo in a single cleaning stage. In contrast, This study makes no offers,
representations or warranties of any
The existing mechanical rougher bank at an the existing cleaner circuit comprises kind (express or implied), and
Australian copper mine delivered combined multiple cleaning stages and suffers poor information and data contained in this
study are for general reference only
residence time of 9 minutes. Concentrate of performance due to gradual build-up of
and may change at any time. FLSmidth
28-30% Cu was consistently achieved at circulating loads. does not guarantee or make any
80% recovery. To evaluate performance of representation regarding the use or the
results of the information or the data
the RFC technology, we installed a small These pilot studies show RFC units can provided in the study in terms of its
scale RFC100 pilot skid at site. deliver improved recoveries, grades and correctness, accuracy, reliability or
throughputs, in a much smaller footprint, otherwise, and shall not be liable for
any loss or damage of any kind
Testing demonstrated that a 5%-8% recovery compared to traditional cleaner circuits. incurred as a result of the use of the
improvement and 10% increase in throughput This is achieved while also lowering energy information or data provided.
could be realised to produce on-spec consumption and so reducing the carbon
concentrate in excess of 28% Cu. This is footprint of the cleaning process. FLSmidth A/S
possible without additional cleaning of the www.flsmidth.com

You might also like