Proposed Addition of Non-Mandatory
Appendix FC-B Withdrawn
Record # 06-934
Non-Mandatory Appendix FC-B (DRAFT April 2013)
FC-B-1400 BACKGROUND
Page 2 of 7
Proposed Addition of Non-Mandatory
Appendix FC-B Withdrawn
Record # 06-934
Two major direct consequences of water exposure
are:
an increase in filter pressure drop and
FC-B-1500 DEFINITIONS
Page 3 of 7
Proposed Addition of Non-Mandatory
Appendix FC-B Withdrawn
Record # 06-934
cellaneous/Div_15/15861S_HEPA_Filter_InServi
Physical absorption: A phenomenon that can ce_Life_0303.doc .
involve the attraction of vapor molecules to the
surface of a liquid and their subsequent phase 32nd International Nuclear Air Cleaning
change and incorporation into the liquid. Conference, 2012 , Development of a Loading
Test for Use in Qualifying AG-1 HEPA Filters,
Physical adsorption: A process that proceeds Charles Waggoner
with increasing air relative humidity during which
vapor molecules are attracted to form initially a
single layer and subsequently multiple layers upon FC-B-3000 AGE AND ADVERSE
a solid surface under the influence of van der OPERATING CONDITION LIMITS
Waals forces.
Test data from the referenced literature, relevant
to filter reliability during service, were evaluated
FC-B-2000 to determine recommended HEPA Filter Service
REFERENCE DOCUMENTS Life limits on age and on operating conditions
involving moisture exposure. The limits on
The recommendations presented in this Non- service life were set based primarily upon data
Mandatory Appendix are primarily based upon the derived from observed decreases in tensile
following references. strength and water repellency of dry filter media
samples with age and cumulative reductions in
Lawrence Livermore National Laboratory, strength with repeated exposure to water.
Maximum HEPA-filter Life, UCRL-AR-134141,
June 1999.
FC-B-3100 AGE LIMIT FOR DRY
DOE, Nuclear Air Cleaning Handbook, CONDITIONS
DOE HDBK-1169-2003, Appendix C,
Determination of HEPA Filter Life, It is recommended that the maximum allowable
http://www.hss.doe.gov/hssnew/nuclearsafety/tec limit on service life for HEPA filters under dry
hstds/docs/handbook/appendixc.pdf . conditions be set at no greater than10 years.
Page 4 of 7
Proposed Addition of Non-Mandatory
Appendix FC-B Withdrawn
Record # 06-934
Page 5 of 7
Proposed Revisions to Section FD Withdrawn
Letter Ballot 12-1706RC1
Revision Record No. 12-1231
Record # 12-1231 Incorporation of Comments from LB 12-1706
Page 1 of 2
FD-4410 GENERAL
A representative sample is a sample of the same lot and batch installed in the main
carbon bed that has been exposed in parallel to the same process stream as the main
carbon bed, with a bed depth equal to the design bed depth of the main carbon bed, and
at a superficial face velocity within ±10% of the design superficial face velocity of the
system main carbon bed . The detailed means to achieve this is left to the designer of
each system, but detailed supporting data (either theoretical or empirical) shall be
presented to substantiate that the flow is representative and the sample is, therefore,
representative of the entire adsorber bank.
The design criterion can be met only when the sampler bed depth is equal to the
system design bed depth and the calculated residence time is within + 10% of the
system design residence time at the system design bed depth. All flow restrictions must
be taken into account when designing a sampler to assure that the pressure drop across
the sampler is consistent with a volumetric flow rate through the sampler that produces a
superficial face velocity and residence time within +10% of the main bed design. Pipe
stubs, valves, unions, fittings, elbows, nozzle effects, and similar items or effects add
pressure drop to the flow path and tend to make a sampler non-representative. This
paragraph does not restrict any specific approach or hardware but requires that the flow
criterion for equal bed thickness must be met.
An adsorbent test canister should be designed to hold adsorbent for testing. The
canister shall be the same depth as the main bed, a nominal 2 in. (50 mm cm) minimum
of 2.25 in. (57 mm) in diameter. If there is a guard bed it shall be duplicated for the
sampler.
The sampler shall be filled with adsorbent from the same lot and batch as the main bed.
The details of test canister designs are provided in Mandatory Appendix FD-II and shall
include provisions to ensure that no bypass will occur, that the sampler(s) will be halide
leak tested concurrently with main bank leak testing, and that the flow path shall be
sealed leak tight after the sampler is removed.
Page 6 of 7
Proposed Revisions to Section FD Withdrawn
Letter Ballot 12-1706RC1
Revision Record No. 12-1231
Record # 12-1231 Incorporation of Comments from LB 12-1706
Page 2 of 2
A test tray assembly is an adsorber cell modified to provide for removal of a portion of
the adsorbent (usually one-eighth) in a section without disturbing the remainder of the
adsorbent. Its use is acceptable as an alternative to individual test canisters described in
Paragraph FD-4431 for obtaining representative samples.
When a test tray assembly is removed, an entire section is emptied into a clean plastic
container or bag and mixed to ensure uniformity. The section shall be refilled with such
makeup adsorbent as required. Plugging of the section is not allowed. This makeup
carbon shall meet the same requirements as the original adsorbent.
The section sampled shall be marked to indicate when a sample was taken and the
section number and position noted both in the field test report and permanent plant
records to ensure that this section is not sampled again. The use of a grain thief or
slotted sampler is not recommended for obtaining a sample from a Type II adsorber cell.
An entire adsorber cell or bed may be removed to obtain a sample. It shall be emptied
into a clean plastic container or bag, the adsorbent mixed to ensure uniformity, a sample
taken, the cell refilled or replaced. If the adsorber cell is refilled it shall be marked as
having been refilled and to indicate a sample was taken. The tray location within the
bank shall be noted both in the field test report and permanent plant records and shall be
marked to not be used for future samples as they are not representative of the adsorbent
in the rest of the bank. The adsorber cell may be replaced provided that the replacement
cell is of the same design as the removed cell and has been filled and tested to the
requirements of FD-5000.
The use of a grain thief is not recommended for obtaining a sample from a Type II
adsorber cell.