You are on page 1of 1

Pump Performance Datasheet

Customer : Quote number : 154873


Customer enquiry : Pump Size : RKBF40/14H
Project : Default Stages : 16
Item number : ITEM 2 Based on curve number : HA12992006 Rev 1
Usage - Tertiary : IPH-WSS Date last saved : 15 Jun 2023 4:32 PM
Quantity :1 Note - Only duty point is guaranteed as per testing standard.
Operating Conditions Liquid
Flow, rated : 18.00 m3/h Liquid Type/ Application : Water
Differential Head (requested) : 427.0 m Additional liquid description : CLEAR WATER
Differential Head (actual) : 427.0 m Solids diameter, max : 0.00 mm
Suction pressure, rated / max : 0.00 / 0.00 bar.g Solids/Bagasse/Stock consistency by : 0.00 %
NPSH available, rated : Ample volume
Site Supply Frequency : 50 Hz Temperature, max : 20.00 deg C
Performance Fluid density rated : 1.00 SG
Speed, rated : 2970 rpm Viscosity, rated : 1.00 cSt
Impeller diameter, rated (approx.) : 150 mm Vapor pressure, rated : 0.02 bar.a
Impeller diameter, maximum : 150 mm Material
Impeller diameter, minimum : 110 mm Material selected : Refer Construction Datasheet
Efficiency : 56.08 % Pressure Data
NPSH required / margin required : 2.32 / 0.50 m Maximum working pressure : 54.32 bar.g
nq (imp. eye flow) / S (imp. eye flow) : 15 / 126 Metric units Maximum allowable working pressure : 44.62 bar.g
Minimum Continuous Safe Flow (MCSF) : 3.07 m3/h Maximum allowable suction pressure : 9.81 bar.g
Head, maximum, rated diameter (approx.) : 554.8 m Hydrostatic test pressure : 66.69 bar.g
Head rise to shutoff (approx.) : 29.94 % Driver & Power Data (@Max density)
Flow, best eff. point : 15.42 m3/h Driver sizing specification : Rated Power
Flow ratio, rated / BEP : 116.73 % Margin over specification : 0.00 %
Diameter ratio (rated / max) : 100.00 % Service factor : 1.00
Head ratio (rated dia / max dia) : 99.22 % Power, hydraulic : 20.90 kW
Cq/Ch/Ce/Cn [HI2010] : 1.00 / 1.00 / 1.00 / 1.00 Power, rated : 37.27 kW
Performance testing standard : ISO 9906 / ANSI-HI 14.6 Power, maximum, rated diameter : 38.50 kW
Gr 2B Minimum recommended driver rating : 45.00 kW / 60.35 hp
60
Power - kW

45
Power
30

15

600 100
Minimum Continuous Safe Flow (MCSF)
540 90
150 mm
480 80

420 70
Efficiency - %

360 60
Head - m

300 Efficiency 50

240 40

180 30

120 20

60 10

0 0
NPSHr - m

5.0
NPSHr
2.5

0.0
0 2 4 6 8 10 12 14 16 18 20 22 24

Flow - m3/h

· · ,
Phone:

Version: 23.1.2