Pump Performance Datasheet

Customer : Quote number :


Customer enquiry : Rdo Pump Size : TE10D
Item number : 002 Stages :1
Usage - Tertiary : Based on curve number : TE10D-FMT-C2950 Rev 1G-C2
Quantity :1 Date last saved : 03 Mar 2021 4:05 PM
Operating Conditions Liquid
Flow, rated : 180.0 m3/h Liquid Type/ Application : Chemical
Differential Head (requested) : 12.00 bar Additional liquid description :
Suction pressure, rated / max : 0.00 / 0.00 bar.g Temperature, max : 20.00 deg C
NPSH available, rated : Ample Fluid density, rated / max : 0.999 / 0.999 kg/dm3
Site Supply Frequency : 50 Hz Viscosity, rated : 1.00 cSt
NFPA Limits Performance
Flow, rated : 170.3 m3/h Speed, rated : 2950 rpm
Head, rated : 12.17 bar Impeller diameter, rated (approx.) : 318 mm
Power, rated : 79.66 kW Impeller diameter, maximum : 370 mm
NPSHr, rated : 4.27 m Impeller diameter, minimum : 270 mm
Efficiency, rated : 72 % Efficiency : 73 %
Flow at 150% : 255.5 m3/h NPSH required / margin required : 4.38 / 0.50 m
Head at 150%, actual/limit : 10.36 bar Head, maximum, rated diameter : 13.80 bar
Efficiency at 150% : 76 % (approx.)
NPSHr at 150% flow : 5.64 m Diameter ratio (rated / max) : 85.95 %
Power required at 150% flow : 96.94 kW Driver & Power Data (@Max density)
Peak power : 122 kW Power, hydraulic : 60.00 kW
Closed valve pressure : 13.80 bar.g Power, rated : 81.93 kW
140% Head at shutoff : 17.03 bar Power, maximum, rated diameter : 122 kW
65% Head at 150% flow : 7.91 bar Material
Cooling flow (None) : 0.00 m3/h Material selected : CI / Br / CS
Pressure Data Selection status
Maximum working pressure : 13.80 bar.g FM/UL/cUL approved : FM/UL/cUL
Maximum allowable working pressure : 25.00 bar.g Near miss reasons :
Maximum allowable suction pressure : 5.17 bar.g
Hydrostatic test pressure : 20.70 bar.g
160
Power - kW

120 Power

80

40

20 100

18 90

16 80
318 mm
14 70
Efficiency - %
Head - bar

12 60

10 50

8 Efficiency 40

6 30

4 20

2 10

0 0
NPSHr - m

50
NPSHr
25

0
0 50 100 150 200 250 300 350 400 450 500 550
Flow - m3/h

Version: 21.0.0
Pump Performance Datasheet
Customer : Quote number :
Customer enquiry : Rdo Pump Size : TE10D
Item number : 002 Stages :1
Usage - Tertiary : Based on curve number : TE10D-FMT-C2950 Rev 1G-C2
Quantity :1 Date last saved : 03 Mar 2021 4:05 PM
Operating Conditions Liquid
Flow, rated : 180.0 m3/h Liquid Type/ Application : Chemical
Differential Head (requested) : 12.00 bar Additional liquid description :
Suction pressure, rated / max : 0.00 / 0.00 bar.g Temperature, max : 20.00 deg C
NPSH available, rated : Ample Fluid density, rated / max : 0.999 / 0.999 kg/dm3
Site Supply Frequency : 50 Hz Viscosity, rated : 1.00 cSt
Flow Head Pump Efficiency Power Required NPSH required
(m3/h) (bar) (%) (kW) (m)
0.00 13.80 0 39.98 2.23
58.06 13.31 43 50.11 2.86
116.1 12.86 63 65.62 3.65
174.2 12.10 73 80.57 4.31
232.2 10.92 76 92.69 5.11
290.3 9.46 74 103 6.90
348.3 7.92 69 112 11.11
406.4 6.10 58 119 19.75
464.4 3.81 40 122 35.38