SR

Type D
Series
mechanical diaphragm

The right dosing choice


SR Series
Type D
Mechanical Diaphragm
Dosing Pumps
SUPPORTING ELEMENTS OF OUR FEATURES
PRODUCTS Mechanical Diaphragm pumps are
suitable for use when:

Versatility
Different diaphragm sizes are available to
- The dosed liquid contains small
amounts of suspended solids
- The dosed liquid is a toxic solution
- A drip proof/air tight application is
required
CODE 11 - S.S.316 VERSION

suit different applications. Starting from - High pressure is not required


1.25 gph to 181.9 gph.
Each pump has a standard gearbox

Reliability
The use of quality materials along with a
reduction system and is available with
either a NEMA 56C motor flange (with
or without motor) and is also available
with an IEC B14 electric motor that meets
UNEL-MEC specifications.
high degree of accuracy and repeatability
assures maximum reliability for the The motor power range is from 1/4 HP to
mechanical diaphragm SR series. 1/2 HP and for IEC motors from 0.18 Kw
up to 0.37 Kw. There are many options

Quality available including different voltages, CODE 13 - PVC VERSION

insulation classes and special explosion


proof versions.

The best performance for each application The gearbox is a standard wormwheel
is achieved through optimal selection of reduction system with all bearings
pump materials and diaphragm design. supported within a fully lubricated
gearbox.

The mechanism for adjusting the stroke


length is a positive stroke spring return
that is operated by an eccentric.
SR Series
Type D
PUMP HEADS the following.
Pump heads are manufactured in - Manual: by a linear micrometer stroke
standard materials: S.S. 316, PVC and knob
PP. - Electrical: via servo motor with
4-20 mA input signal or interfaced
A wide range of other materials such as with PROFIBUS or other BUS
HASTELLOY, ALLOY 20, PTFE and PVDF - Pneumatic: by a pneumatic servo
are also available. controller with signal from 3 to 15 PSI
Maximum temperature of fluids air input.
pumped
- 140° F with S.S. 316 pump head MULTIPLE HEADED PUMPS
- 104° F with PVC pump head Pumps with multiple heads are available
upon request.
Jacketed pump heads for either cooling or
heating are available. Flow rates of each pump head can be
adjusted independently while running
DIAPHRAGM or stopped.
PTFE
“D” series Mechanical Diaphragm
SUCTION AND DISCHARGE pumps are available in four different
CONNECTIONS models:
Standard: NPT - D 50 U Stroke length 5 mm
Upon request: Flanged, ANSI or UNI - D 100 U Stroke length 10 mm
- D 101 U Stroke length 10 mm
All pumps use ball check valves as - D 121 U Stroke length 12.50 mm
standard: single or double balls in each
valve, determined by the piston diameter The above models have different
or the materials of construction. diaphragm sizes for varied capacities and
pressures.
STROKE ADJUSTMENT
Flow rate adjustment is possible while
the pump is running or stopped. The
movement of the diaphragm is based
on a precise reciprocating gearbox
which provides an exact volumetric
displacement.
Stroke adjustment can be carried out by
Mechanical Diaphragm
Dosing Pumps
STANDARD MATERIALS OF CONSTRUCTION FOR MECHANICAL DIAPHRAGM PUMPS
CODE PUMP HEAD VALVE BALL VALVE SEAT DIAPHRAGM VALVE SEALS
11 S.S. 316 S.S. 316 S.S. 316 PTFE/NBR FPM
12 PP/FRV PYREX PP/FRV PTFE/NBR FPM
13 PVC PYREX PVC PTFE/NBR FPM
16 PVC S.S. 316 PVC PTFE/NBR FPM
17 PP S.S. 316 PP PTFE/NBR FPM
23 PVDF PYREX PVDF PTFE/NBR FPM
FPM = fluoroelastomer S.S 316 = stainless steel 316 C.O. = Chromium Oxide PP/FRV = polypropylene + glass fiber
Difference executions on request

Pump Model Numbering System


D 100N 70/ B 11 DV
1ST group 2nd group 3rd group 4th group 5th group 6th group
“D” series
Diaphragm diameter Strokes Per Minute Not standard
Mechanical diaphragm Stroke length Liquid End Materials
in mm F(1/24) B (1/12) Special code
dosing pump
If pump is to be supplied without motor add: W/M

GENERAL DIMENSIONS IN mm

D050 D100 D101 D121

A 57 57 68 68

B 90 90 100 100

C 70 70 65 65

D 75 75 73 73
E

E 375 375 410 410

F 90 90 90 90 H

G 75 75 75 75 I

H 115 115 125 125

I 65 65 65 65
G
F

O
D

L 7 7 7 7

M 130 130 170 170


L
N 33 33 33 33

O 80 80 78 78 A B C N

These are general dimensions and indicative of the maximum acceptable pump dimensions
SR Series
Type D 050U

TECHNICAL GUIDE
Reduction ratio (*1) Capacity (*2) Max Press. PSI Diaphrag.
Stroke
Connections Ø
Pump type SPM GPM GPH PSI Motor Lenght
(*3) (mm)
(mm)
60 Hz 60 Hz 60 Hz SS 316 PVC
I 42 0,0211 1,27
F 70 0,0369 2,22 1/4 HP
D-050U-30 203 145 NEMA 30
C 116 0,0607 3,64 56C
B 139 0,0738 4,43 1/2” or
5
I 42 0,0738 4,43 NPT
0,18kW
F 70 0,1268 7,60 for
D-050U-50 145 IEC 50
C 116 0,2166 13,00 motor
B 139 0,2586 15,53

(*1) Strokes per minute designation code with 4 poles motor (1725 rpm)
I = Reduction ratio 1 : 40 = 42 strokes at 60 Hz
F = Reduction ratio 1 : 24 = 70 strokes at 60 Hz
C = Reduction ratio 1 : 14,5 = 116 strokes at 60 Hz
B = Reduction ratio 1 : 12 = 139 strokes at 60 Hz
(*2) The capacity is subject to change due to working pressure, dosed liquid, viscosity and piping dimensions.
(*3) Different types and sizes of connections are available upon request
(4) The pumps can be supplied with accessories if requested.
(5) The pumps are epoxy coated RAL 7030
Mechanical Diaphragm
Dosing Pumps
Type D 100U

TECHNICAL GUIDE
Reduction Ratio (*1) Capacity (*2)
Max Press. PSI Connections (*3) Diaphrag. Stroke
Pump type SPM GPM GPH Motor Ø Lenght
(mm) (mm)
60 Hz 60 Hz 60 Hz SS 316 PVC SS 316 PVC
I 42 0,24 14,27
F 70 0,40 23,78
D-100U-70 72 1/2” NPT 70
C 116 0,66 39,63
B 139 0,79 47,56
I 42 0,36 21,66
F 70 0,61 36,46 1/4 HP
D-100U-90 43 NEMA 90
C 116 1,01 60,77 56C
B 139 1,22 72,91 or
3/4” NPT 10
I 42 0,49 29,59
0,18kW
F 70 0,82 49,41 for
D-100U-105 IEC 105
C 116 1,31 78,73 motor
B 139 1,57 94,48
22
I 42 0,56 33,55
F 70 0,93 56,01
D-100U-120 1” NPT 120
C 116 1,65 98,81
B 139 1,98 118,57

(*1) Strokes per minute designation code with 4 poles motor (1725 rpm)
I = Reduction ratio 1 : 40 = 42 strokes at 60 Hz
F = Reduction ratio 1 : 24 = 70 strokes at 60 Hz
C = Reduction ratio 1 : 14,5 = 116 strokes at 60 Hz
B = Reduction ratio 1 : 12 = 139 strokes at 60 Hz
(*2) The capacity is subject to change due to working pressure, dosed liquid, viscosity and piping dimensions.
(*3) Different types and sizes of connections are available upon request
(4) The pumps can be supplied with accessories if requested.
(5) The pumps are epoxy coated RAL 7030
SR Series
Type D 101U
and D 121U

TECHNICAL GUIDE
Reduction Ratio (*1) Capacity (*2)
Max Press. PSI Connections (*3) Diaphrag. Stroke
Pump type SPM GPM GPH Motor Ø Lenght
(mm) (mm)
60 Hz 60 Hz 60 Hz SS 316 PVC SS 316 PVC
F 84 0,48 28,53
D-101U-70 C 116 0,66 39,00 116 1/2” NPT 70
B 144 0,81 48,72
F 84 0,78 46,92 1/3 HP
NEMA
D-101U-90 C 116 1,01 64,04 72 56C 90
B 144 1,35 80,85
or
3/4” NPT 10
F 84 1,06 63,73
0,25kW
D-101U-105 C 116 1,31 87,19 for 105
IEC
B 144 1,75 104,94 motor
43
F 84 1,19 71,33
D-101U-120 C 116 1,65 97,65 1” NPT 120
B 144 2,16 129,35

F 84 1,70 102,09
1/2 HP
D-121U-120 C 116 2,31 138,86 43 1” NPT NEMA 120 12,5
56C
B 144 3,03 181,98

(*1) Strokes per minute designation code with 4 poles motor (1725 rpm)
I = Reduction ratio 1 : 40 = 42 strokes at 60 Hz
F = Reduction ratio 1 : 20 = 84 strokes at 60 Hz
C = Reduction ratio 1 : 14.5 = 116 strokes at 60 Hz
B = Reduction ratio 1 : 11.5 = 144 strokes at 60 Hz
(*2) The capacity is subject to change due to working pressure, dosed liquid, viscosity and piping dimensions.
(*3) Different types and sizes of connections are available upon request
(4) The pumps can be supplied with accessories if requested.
(5) The pumps are epoxy coated RAL 7030
Mechanical Diaphragm
Dosing Pumps
Typical Installation
SAFETY VALVES

PULSATION
BACK PRESSURE
DAMPENERS
VALVES

FILTERS

Each metering pump can be supplied with accessories 4.- PULSATION DAMPENER
to enhance the performance and accuracy of the Metering pumps have a pulsating flow.
dosing pump system. Both spring return plunger dosing pumps and quick
These accessories will assure : closing valves start and stop fluids that are in motion.
- Increased efficiency and increased pump life Spring return plunger dosing pumps derive their
- Decreased maintenance and operational costs pumping action by capturing a given amount of fluid in
a chamber and pushing it out of the pump’s discharge
Controlling fluid dynamics is essential to ensure efficient valve.
and safe use of the process system. Uncontrolled fluid
in motion can physically destroy a pumping system Each pump cycle also includes a suction stroke during
which includes pump, valves, flow meters, back which the discharge fluid flow is stopped.
pressure valves, inline instrumentation and piping. This pumping action produces an acceleration/
deceleration of the fluid, creating units of uncontrolled
1.- FILTERS energy resulting in pulsations observed as pressure
We suggest installing filters on the suction side piping spikes.
to prevent problems that can be caused by welding
particles, seal fragments or impurities in the liquid. Pulsation dampeners are required for two reasons:
The use of filters assures trouble-free dosing. - To reduce high, non-permissible pressure fluctuations.
- To create a nearly smooth and continuous flow.
2.- PRESSURE RELIEF VALVES
Pressure relief valves are designed to protect the pump 5.- CALIBRATION CYLINDERS
and chemical feed system from over pressure damage Calibration Cylinders allow visual confirmation of the
caused by defective equipment or a blockage in the pumps flow rate.
chemical feed line.

3.- BACK PRESSURE VALVES


Back pressure valves apply a constant positive pressure
to the discharge of the metering pump to prevent
siphoning and eliminate varying down-stream line
pressure.
Accessories
Safety relief valves

Type Pump capacity Connections


TS-10 200 l/h 3/8” or 1⁄2”G.F.
TS-13 400 l/h 1⁄2” G.F
TS-21 1000 l/h 1” G.F

Body PVC or S.S. 316

* 316 S.S. Safety Relief Valve set pressure: max 588


PSI. Higher pressures are available upon request.
PVC Safety Relief Valve set pressure: max 145 PSI.
For higher set pressures consult our technical
department.

Pulsation dampeners

Type: HSTX
Body in 316 S.S. composed of a
two part assembly utilizing a special
housing that under dynamic pressure
tends to seal itself.
Bladders are compatible with the
liquids used. Built in accordance with
ASME VIII° Div. 1 rules.

Type: HSTPVC
Body in PVC composed of a two part
assembly utilizing a special hosing
that under hydraulic pressure tends to
seal itself.
Maximum temperature: + 122 °F.
Bladders are chemically compatible
with process liquids.
Relief valves

Type Pump Capacity Connections


VSCS-6 23.7 g/h 1⁄2” G.F
VSCS-10 60.7 g/h 1⁄2” G.F
VSCS-14 110.9 g /h 3⁄4” G.F
VSCS-22 277.4 g/h 1” G.F

Body PVC or S.S. 316


Diaphragm PTFE/NBR

* Relief valve set pressure is 0-284 psi : Maximum


set pressures will change based on valve size and
materials of construction
G.F.= gas Female

Back pressure valves

Type Pump Capacity Connections


VSCC-6 23.7 g/h 1⁄2” G.F
VSCC-10 60.7 g/h 1⁄2” G.F
VSCC-14 110.9 g/h 3⁄4” G.F
VSCC-22 277.4 g/h 1” G.F

Body PVC or S.S. 316


Diaphragm PTFE/NBR

* Back pressure valve set pressure: 0-35.5 psi.


G.F.= gas Female

Polyethylene tanks
Metering pumps can be mounted on
tank tops
Our product line also includes the following:

SR series:
Hydraulic diaphragm dosing pumps, type “B”, “BR” and “SD”
Mechanical diaphragm dosing pumps, type “FM”
Plunger dosing pumps, type “A”

PDP series: API 675, non-lost motion


Positive displacement dosing pumps, type “AI” and ”SDI”
High pressure positive displacement dosing pumps, type “AP-AI”

SDP series:
Solenoid dosing pumps, type “S”
Solenoid dosing pumps type “GA”

H series:
Automatic plants for dissolution and preparation of powdered polyelectrolytes, type “HA” and “HB”

EM series:
Electric mixers for chemical mixing, type “DMT”, “DEM”, “DRV” and “DRC”

Standard Equipment & Controls HOME OFFICE


P.O. Box 330453 Via G. Carducci 141
Atlantic Beach, Florida 32233 20093 Cologno Monzese (MI) Italy
1-800-367-9230 Toll Free Tel.: +39 02 27301324
XMUOPCDG000G0010

1-904-223-4381 Office Fax: +39 02 26700883


1-904-223-5607 Fax e-mail: info@doseuro.com
sales@standarde.com E-mail www.doseuro.com
www.standarde.com

The right dosing choice