Professional Documents
Culture Documents
Customer/plant information
Drawing/sketch
Please provide us with a sketch or drawing of the upstream process as this will be extremely
helpful in the project evaluation. If you do not have a real drawing (in most cases, you will
not) then please make a sketch by hand (as you see the set-up) – then scan it and forward it
together with this document.
Pumps –
Process information
Feed Type (primary, WAS, digested or) Primary Fresh hot POME
Feed Ratio, % (if mixture of different streams) Fresh POME
Total feed rate, m3/hr (not per decanter but total) Max 3 m3/hr.
Feed Solids, % TSS (total suspended solids) 30,000 mg/lit
Solids rate, kg/hr (solids loading) 90 kgs/hr.
Feed Volatiles, % TVS (total volatile solids) No Data
Feed SVI ( Sludge Volume Index - how well does it No Data
settle)
Feed Temp, °C 70 -80
Is the feed corrosive? (specify pH-level, Cl-) Yes, corrosive and acidic pH3.5 to
4.5
Is the feed erosive? (does it contain sand or similar?) Yes, (sand/Solids)
Does the feed contain fat, oil or grease? Yes ,3000 -4000 ppm
Specify industrial application (if more than 15% of Palm oil mill
total)
Plant Chemical Addition (ferric, lime, alum, etc.) No
Most critical item? (what is the bottle neck) Solids
Section 3
Sizing Data
Operating Times
Total Flow
Volumetric (m3/h) 3
Solids (Kg/h) 90
Capacity
Number of Unit
Operating 1
Standby 0
Range (%)
Design (%)