VIBRATION ANALYSIS CHECKLIST 1/2
MONTH: DECEMBER
ISO
VELOCITY FOUNDATIO
EQUIPMENT R POINTS DIRECTION EN ACC gE MACHINE EN. ACC CLASS SEVERITY REMARKS DATE
(mm/s) N
GROUP
SN°
G1&3 G2&4 R F CL1 CL2 CL3 G A D Sustain Intervent Stop
Axial (A) / / / / / / / /
DE Radial vertical (V) 1.6 2.17 A YES
CEMENT MILL YES
Radial horizontal (H) 3 2.66 A
1 MOTOR
Axial (A) 2.5 8.28
● ● ● D YES
18.01.2023
(84RM01.M01)
NDE Radial vertical (V) 0.9 11.03 D YES
Radial horizontal (H) 2.1 5.46 D YES
Axial (A) / / / / / / / /
DE Radial vertical (V) 20 14.73 D YES
INDUCED DRAFT Radial horizontal (H) 6.5 18.62 D YES
2
FAN (84FN01.M01) Axial (A) 3.4 2.67
● ● ● A YES
18.01.2023
7
(83BC02.M01) Axial (A) / /
● ● ● / / / / / /
18.01.2023
Axial (A) / / / / / / / /
DE Radial vertical (V) 11 0.83 G YES
SEAL FAN MOTOR Radial horizontal (H) 4.1 0.63 G YES
8
(84FN02.M01) Axial (A) / /
● ● ● / / / / / /
18.01.2023
DEPARTMENT: ELECTRICAL
SECTION: UTILITY
LEGEND
R: Rigid
F: Flexible
CL: Classification
G: Good
A: Alert
D: Danger
G1&3/G2&4: Machine Group REPORTED BY: MINDINI ERIC CHANDOP
gE: Enveloped Acceleration
OBSERVATION(S) :
1. MILL MOTOR: OK
2. INDUCED DRAFT FAN: Excessive Vertical and Horizontal vibration on the DE indicates possible MISALIGNMENT and IMBALANCE.
3. SEPARATOR MOTOR: OK. The entire structure is experiencing excessive vibration.
4. 86 BUCKET ELEVATOR MOTOR: Ok
5. DILUSION FAN MOTOR: Ok
6. 84 BUCKET ELEVATOR MOTOR: Excessive Horizontal vibration on the DE of the motor, indicating possible IMBALANCE.
7. 83BC02 MOTOR: Excessive Vertical vibration on DE and excessive Vertical and Horizontal vibration on the NDE indicates possible MISALIGNMENT and IMBALANCE
8. SEAL FAN MOTOR: OK
9. 84RF02 MOTOR: Here we notice very high Vertical vibration on the entire motor.
CRAFT´s SIGNATURE: ENG´s SIGNATURE