You are on page 1of 28

FLAMEPROOF & MINING SOLUTIONS

Short Form Catalogue 2014

www.acdc.co.za
HALO SERIES UNDERGROUND LIGHTING SOLUTIONS IP68
Lumen per LED’s per Power per Range fed from Min. Cutting
Code meter meter meter both sides 36V Length
HALO-UL-60 1000lm 60 9W 35m 183mm (11LED's)
Applications Its versatility provides daylight conditions underground, ideal for
haulages, refuge bays, conveyors and tipping areas
HALO-UL-36 600lm 36 5.5W 55m 306mm (11LED's)
Applications Ideal where high bright conditions are required, commonly used at
machine stations of conveyors
HALO-UL-30 500lm 30 4.4W 65m 367mm (11LED's)
Medium to high bright option, ideal for haulages and general tunnel
lighting
HALO-UL-24 300lm 24 3.6W 75m 458mm (11LED's)
Applications Providing a medium to good lighting platform, a good solution to run
along conveyor belts
HALO-UL-18 250lm 18 3.3W 105m 500mm (9LED's)
Applications Good luminescence, long range and high energy efficiency. Ideal lighting
platform for stopes and confined spaces
HALO-UL-12 200lm 12 2.4W 155m 250mm (3LED's)
Applications Medium to good lighting solution, with a long range and low consumption,
ideal for stope areas and confined spaces
Accessories
Code Description
HALO-UL-CC Connector Kit: L-connector, T-connector, 5x anti-skid clips,
HALO-UL-ACH 5x PC cover, 5x heat shrink tube
HALO-UL-RK Repair Kit: front connector, 3m lead & end
HALO-UL-CC HALO-UL-RK
HALO-UL-ACH 1m Length profile & 5x fixing screws
Power Supplies - Input 85-265VAC; Output: 36VDC
Code Description
HALO-PC-60 60W Power Supply, Aluminium IP67
HALO-PC-80 80W Power Supply, Aluminium IP67
HALO-PC-100 100W Power Supply, Aluminium IP67
HALO-PC-150 150W Power Supply, Aluminium IP67
HALO-PC HALO-PC-200 200W Power Supply, Aluminium IP67
HALO-MC HALO-PC-240 240W Power Supply, Aluminium IP67
HALO-PC-300 300W Power Supply, Aluminium IP67
HALO-PC-350 350W Power Supply, Aluminium IP67
MSD-CV-300W 300W Power Supply, Encapsulated IP67
Enclosure
HALO-MC Lockable vented metal enclosure for power controllers,
MSD-CV-300W complete with pre-drilled holes for cable entries

Halo Series Evacuation Pulse System IP68


Lumen per LED’s per Power per Range fed from
Code meter meter meter both sides 24VDC
HALO-PS 80lm 14 1W 100m

Applications
• Operating on high sight impact and not sound
• Perfect for machine operators with excellent visibility in smoke filled or low light conditions
• The Halo Series Evacuation Pulse System will:
- prevent your work force from entering dangerous environments
- bring order
- suppress panic and provide comfort in a stressed and dangerous environment.

Accessories
Code Description
HALO-PS-CR Pulsating controller & remote
HALO-PS-CR For 24VDC Power Supplies see pages 81 - 82

1 FLP
EXPLOSION PROOF LIGHTING
LED Bulkhead Fittings IP66
• Anti glare, shock and vibration resistant
• Osram LED's and high efficiency drivers
• Suitable for harsh and corrosive environments -40 to 55°C
• Die Cast Aluminium body with tempered glass bowl
• Group II Zone 1, 2
Code Supply* Power Colour Temp. Lumen Beam Weight (kg) Size (mm)
EX-KFTB12CH 100-240VAC 12W 6000-7100K 1200lm 80° 2 Ø162x147
EX-KFTB18CH 100-240VAC 18W 6000-7100K 1600lm 80° 2 Ø162x147
Ex d IIC (H2) T6 Gb EX-KFTB24CH 100-240VAC 24W 6000-7100K 2150lm 80° 2 Ø162x147
80° 80°
EX-KTFF12CH 100-240VAC 12W 6000-7100K 1200lm 200° 2 Ø162x147
EX-KTFF18CH 100-240VAC 18W 6000-7100K 1600lm 200° 2 Ø162x147
EX-KTFF24CH 100-240VAC 24W 6000-7100K 2150lm 200° 2 Ø162x147
* Other voltages available on request

200° 200°
KHJ-09 KHJ-10

Accessories
Code Description Weight (kg)
KHJ-09 Mounting Bracket 0.4
KHJ-10 Stanchion Bracket 2.26
Mid-Power LED Light IP66
• Osram LED & high efficiency drivers
• Suitable for harsh and corrosive environments -40 to 55°C
• Robust Aluminium enclosure and tempered glass
• Group II Zone 1
Code Supply Power Colour Temp. Lumen Beam Weight (kg) Size (mm)
EX-KF120H4V4CH 180-277VAC 120W 6000-7100K 11500lm 60° 13.5 426x410x187
Ex d IIB T8 Gb EX-KF120H6V6CH 180-277VAC 120W 6000-7100K 11500lm 120° 13.5 426x410x187
60° 60° EX-KF150H4V4CH 180-277VAC 150W 6000-7100K 14400lm 60° 13.5 426x410x187
EX-KF150H6V6CH 180-277VAC 150W 6000-7100K 14400lm 120° 13.5 426x410x187

KHJ-03 KHJ-12 SB209333/M12 KHJ-11

120° 120° Accessories


Code Description Weight (kg)
KHJ-03 Mounting Bracket 0.4
KHJ-12 Stanchion Bracket 2.26
SB209333/M12 Pendant Mount Eye Bolt M12 0.26
KHJ-11 Wire Guard 0.38
Torches IP68
• Osram/Cree LED source
• High strength Aluminium hard anodized to military spec. for extreme resistance to abrasion and corrosion
• Tempered glass and advanced optics for use up to 200m
• 3 Modes: High output, working output, flashing (5Hz)
• Constant current ensures stability of brightness
• Lithium batteries with built-in heat/failure protection, provides high power capacity and long life span
• Anti-roll octagonal design
• Group II Zone 1
Beam Bat. Life Span
Ex ib IIC T4 Gb Code Colour Temp. Lumen Weight (kg) Size (mm)
Spot Flood High Working
KACF80GCH68 6000-7000K 143lm 10° 80° ≥ 9hrs ≥ 18hrs 0.19 Ø35x156
Battery Lifespan: 300 cycles. Charge time: 6hrs. Rated input voltage: 3.7V. Rated capacity: 2.2Ah
Spot beam at high output: @ 1m, Ø = 0.1m 5700Lx
@ 5m, Ø = 0.5m 245Lx
@ 10m, Ø = 1m 0Lx

FLP 2
EXPLOSION PROOF LIGHTING
Ex nR II T4 Gc LED High Power Multi Purpose Light IP66
• Energy saving in strong Aluminium housing
• Powerful, accurate, anti glare, shock and vibration resistant
• Osram LED's and high efficiency drivers
• Used for area lighting in warehouses and petrochem sites -40 to 55°C
• Group II zone 2, Zone 22
Code Supply Power Colour Temp. Lumen Beam Weight (kg) Size (mm)
EX-KPLB80H4CH 100-240VAC 80W 6000-7100K 8700 60° 9 210x400x161
EX-KPLB120H4CH 100-240VAC 120W 6000-7100K 12420 60° 11 260x400x161
EX-KPLB160H4CH 100-240VAC 160W 6000-7100K 16560 60° 11 260x400x161
60° 60°
EX-KPLB200H4CH 100-240VAC 200W 6000-7100K 20700 60° 16 400x400x161
EX-KPLB240H4CH 100-240VAC 240W 6000-7100K 24800 60° 21 500x400x161
EX-KPLB80H6CH 100-240VAC 80W 6000-7100K 8700 120° 9 210x400x161
EX-KPLB120H6CH 100-240VAC 120W 6000-7100K 12420 120° 11 260x400x161
EX-KPLB160H6CH 100-240VAC 160W 6000-7100K 16560 120° 11 260x400x161
EX-KPLB200H6CH 100-240VAC 200W 6000-7100K 20700 120° 16 400x400x161
120° 120°
EX-KPLB240H6CH 100-240VAC 240W 6000-7100K 24800 120° 21 500x400x161
Accessories
Code Description
KHJ-01 Pipe Clamp
KHJ-02 Stanchion Bracket
SB209333/M10 Pendant Mount Eye Bolt M10 KHJ-01 KHJ-02 SB209333/M10

Ex d IIB T8 Gb Robust Low Bay LED Lights IP66


• Osram LED's and high efficiency drivers
• High impact resistant enclosure, ideal for marine and corrosive environments -40 to 55°C
• For extremely corrosive, wet, dusty, hot and cold conditions
• Group II Zone 1, 2
Rectangular
Code Supply Power Colour Temp. Lumen Beam Weight (kg) Size (mm)
EX-KAF30CH 100-240VAC 30W 6000-7100K 3000 120° 4.7 480x180x62
Accessories
Code Description Weight (kg)
KHJ-03 Mounting Bracket 0.4
KHJ-04 Pipe Clamp 0.27
KHJ-05 Wire Guard 0.1
SB209333/M10 Pendant Mount Eye Bolt M10 0.1
Ex d IIB T5/T6 Gb

KHJ-03 KHJ-04 KHJ-05 SB209333/M10

Round
Code Supply Power Colour Temp. Lumen Beam Weight (kg) Size (mm)
EX-KGF30 100-240VAC 30W 6000-7100K 2900 60° 5.5 311x284x190
EX-KGF60 100-240VAC 60W 6000-7100K 4500 60° 5.5 311x284x190
Accessories
Code Description Weight (kg)
KHJ-03 Mounting Bracket 0.4
KHJ-07 Stanchion Bracket 0.4
KHJ-08 Wire Guard 0.3
SB209333/M10 Pendant Mount Eye Bolt - M10 0.1

KHJ-03 KHJ-07 KHJ-08 SB209333/M10

LED High Bay Explosionproof Light - Supply Voltage: 85 - 265VAC 120° Beam Angle
Code SEM-HG*-*
*Add Watts to code: 50W, 70W, 100W, 120W
Luminous Efficiency 100lm/W
Size (mm) Ø295 x 164H
*Add colour to code: ● CW (Cool White) 5000-5500k, ● WW (Warm White) 2700-3000k

3 FLP
EXPLOSION PROOF LIGHTING
Ex II2G Ex d I/II B LED Area Lights with Protection Brackets - c/w LED (Size is Body of Lamp)

LT-0300 Code Code Description Size (mm) Watts Watts


Light Guard Ø x L 110/220V 12/24V
LT-0300* ALT-0300-GD Area Light 300mm 141.5 x 300 28W 48W
LT-0600* ALT-0600-GD Area Light 600mm 141.5 x 600 56W 96W
ALT-0300-GD LT-1200* ALT-1200-GD Area Light 1200mm 141.5 x 1200 112W 192W
* Add voltage to code: 12 (12/24VDC), 110 (110VAC), 220 (220VAC)
Light & Guard • Order light & guard separately
Combined

Flood Light 230V IP66 - Lamps excluded


Watts Code High Code Code Lamp
Pressure Sodium Lamp Metal Halide Lamp Empty Fitting Holder
 70W BAT53-HSE70G BAT53-HIE70G – E27
100W BAT53-HSE100G BAT53-HIE100G – E27
250W BAT53-HSE250G BAT53-HIE250G – E40
400W BAT53-HSE400G BAT53-HIE400G BAT53-EMPTY E40
Description
400W 250W 70/100W ATEX: Group II category 2G Ex mark: Ex II 2G Ex de II BT3
Ideal for IIA, IIB locations Material: 
Suitable for Zone 1, 2 and 21, 22 locations Die cast aluminium alloy outer shell
Aluminium reflector IP66 High pressure anti static plastic sprayed
Temperature Range: -25°C to +55°C Silicon rubber seal, high grade anodic
Bulkhead IP65 - Supply Voltage: 230VAC - Lamps excluded

Code Watts Lamp Type Lamp


Holder
BAD-A200X 200W Incandescent or E27
(empty fitting for use 160W Mercury Blended or
with a variety of lamps)  20W Energy Saving CFL
BAD61-HSE70X  70W High Pressure Sodium. c/w ballast & ignitor E27
BAD61-HSE100X 100W High Pressure Sodium. c/w ballast & ignitor E27

Description
BAD-A200X BAD61 ATEX: Group II2G Ex d II CT4
Ideal for IIA, IIB, IIC areas
Suitable for Zone 1 and Zone 2 locations. (Certificate No. PTB 03 ATEX 1077)
Energy Saving Lighting IP65 - Supply Voltage: 230VAC. Lamps included. Suitable for ceiling mounting.
Code Watts Lamp Type Lamp
Holder
BAD81-42X 42W Energy Saving CFL E27
BAD81-68X 68W Energy Saving CFL E27
Description
Atex: Group II Category 2G Accessories
Ideal for IIA, IIB, IIC areas Code Description
Suitable for zone 1, 2 and 21, 22 81004 42W Spare lamp
BAD81-42X BAD81-68X Ex mark: II 2G Ex d II CT4 81005 68W Spare lamp
Explosion Induction Proof Lighting IP66 - Supply Voltage: 230VAC - Lamps included.
Code JM-04-001*
*Add Watts to Code 40W, 50W
Size (mm) Ø265 x 240H
• High Corrosive & High Temperature Resistant
• High Pressure Die-cast Polycarbonate Material
• Aluminium Anti-Corrosion Surface Treatment

FLP 4
EXPLOSION PROOF LIGHTING
Fluorescent 230V - IP66 (Certificate No. S-XPL/04547)
ATEX: Group II category 2GD Material: Polycarbonate diffuser
Ideal for IIA, IIB, IIC locations Full plastic body
Suitable for Zone 1, 2 and 21, 22 Ex mark: Ex II 2G Exedq II CT4 Ballast for 2 x 36W

Ballast for 2 x 58W Key

* NB Note: For LED Zone 2,21 & 22 - Led Fitting complete with LED Tubes Accessories
Code (CFL) Size (mm) Code (CFL) * Code (LED)
Code Description
Ceiling Mount Watts L x W x D Emergency Ceiling Mount
BAY51-Q18X1X 1 x 18W (2FT)   780 x 196 x 128 BAY51-Q18X1X-EMG BNY81-LED9X1X 5136011 Explosion-proof ballast for 1x36W or 2x36W
BAY51-Q18X2X 2 x 18W (2FT)   780 x 196 x 128 BAY51-Q18X2X-EMG BNY81-LED9X2X 5118004 Explosion proof ballast for 1x18W or 2x18W
BAY51-Q36X1X 1 x 36W (4FT) 1380 x 222 x 134 BAY51-Q36X1X-EMG BNY81-LED18X1X BAY51-Q56-BAL Explosion proof ballast for 2x58W
BAY51-Q36X2X 2 x 36W (4FT) 1380 x 222 x 134 BAY51-Q36X2X-EMG BNY81-LED18X2X 5136004 36W Key for opening fitting
BAY51-Q56X2X 2 x 58W (5FT) 1672 x 196 x 115 BAY51-Q56X2X-EMG BNY81-LED28X2X 5118002 18W Key for opening fitting
(Lamps excluded.) See page 743 for spare lamps. Emergency duration 90min on one lamp. BAY51-LH Spare Lamp Holder for 18W to 36W
Fluorescent 230V IP65 - c/w Lamps Portable Explosion Proof Light IP65 - c/w Battery

Description Description
ATEX: Group II category 2G Ideal for IIA, IIB, IIC locations suitable for Zone Lamps included 6400k daylight
1 and 2 Material: Aluminium body, glass lamp housing, stainless steel Rechargeable.
diffuser, carbon steel reflector c/w wheels & 2 light levels selectable
Ex mark: Ex II 2G Ex d II C T6 Ex mark: Ex de II C T6

Code - Ceiling Mount Size (mm)


Watts L x W x D Code BW3210
BAY51S-18X 1 x 18W   885 x 130 x 130 Lamp Power 30W
BAY51S-36X 1 x 36W 1470 x 130 x 130 Battery Type 12Ah Sealed Lead acid
BAY51D-36X 2 x 18W 865 x 225 x 140 Working Time High: 16hrs/Low: 36hrs
BAY51D-72X 2 x 36W 1470 x 225 x 140 Material - Head/Battery Box Aluminium Alloy/Aluminium Alloy
Hand Lights • Toughened c/w battery charger c/w battery charger c/w battery charger
Glass
& Torches
• Cable not
included

Code BSX-60 BAD203 BAD201 BAD303


Power Supply ≤100W (E27) 7.2V 2Ah Battery (incl.) 3.6V 1.8Ah Battery (incl.) 6V 4.5Ah Battery (incl.)
Battery life ­– ≥10hrs ≥10hrs High Intensity: 1-2hrs. Working light: ≥10hrs
Charging time ­– 4.5-6hrs 4.5hrs 12-16hrs
Ex Mark Ex II 2G Ex de II CT4 Ex II 2G Ex ib II CT6 Ex II 2G Ex ib II CT6 Ex II 2G Ex de II CT4
Zone Zones 1 & 2 Zones 1 & 2 Zones 1 & 2 Zones 1 & 2
IP-Rating IP65 IP68 IP66 IP68
Size Ø138 x 433mm Ø40 x 208mm Ø25 x 120mm 105 x 53 x 153 (excl. head)
Spares Spare Glass: BSX102 Battery 203-BAT Battery 201-BAT Battery 303-BAT

5 FLP
EX ED
AT OV
PR
EXPLOSION PROOF LIGHTING
AP Titano Asymmetrical Diffused Floodlights (wide beam) 230V IP66
Code Watts Lamp Type Current Lamp Holder
GW84592M 250W MT Metal Halide 2.2A E40
GW84594M 400W MT Metal Halide 3.4A E40
GW84407 Optional Wire Guard - - -
GW84592M - 250W 1kV II 3G - Ex nR IIA T2 Gc X II 3D - Ex tc IIIA T240°C Dc IP66 X -20°C ≤ Ta ≤ +25°C
GW84594M - 400W 1Kv II 3G - Ex nR IIA T2 Gc X II 3D - Ex tc IIIA T240°C Dc IP66 X -20°C ≤ Ta ≤ +25°C
Halle-High Bay 230V IP65 Control Gear. 470mm ø Bowl
GW83563S 250W SE High Pressure Sodium 3A E40
GW83564M 250W ME Metal Halide 2.2A E40
GW83566S 400W SE High Pressure Sodium 4.2A E40
GW83567M 400W ME Metal Halide 3.4A E40
GW84814 Optional Wire Guard -
GW83563S - 250W II3GD Ex nA IIC T2 Gc Ex tc IIIC T113°C Dc -20°C ≤ Ta ≤ +25°C X IP65
GW83564M - 250W 1kV II3GD Ex nA IIC T1 Gc Ex tc IIIC T137°C Dc -20°C ≤ Ta ≤ +25°C X IP65
GW83566S - 400W II3GD Ex nA IIC T1 Gc Ex tc IIIC T156°C Dc -20°C ≤ Ta ≤ +25°C X IP65
GW83567M - 400W 1kV II3GD Ex nA IIC T1 Gc Ex tc IIIC T137°C Dc -20°C ≤ Ta ≤ +25°C X IP65
IP65 - ATEX ZNT ZONE 2(G) - ZONE 22D Range - with P.F. correction - Class 1 RAL 7035 Grey
shock ­resistant polycarbonate base, weatherproof light fitting (Lamps excluded)
Spare Lamp No. of Dimensions (mm)
Code Diffuser Power Lamps L x H x W
GW81084 GW80134 18W 2 (2ft) 680 x 112 x 195
GW81085 GW80135 36W 2 (4ft) 1290 x 112 x 195
GW81086 GW80136 58W 2 (5ft) 1590 x 112 x 195`
ATEX Classification - versions with electronic ballast
Stainless steel diffuser clamps GW81084 - II 3 G – Ex nA IIB T4 Gc II 3D- Ex tc IIIB T50°C Dc IP65
GW81085 - II 3 G – Ex nA IIB T4 Gc II 3D- Ex tc IIIB T52°C Dc IP65
Spare Clamps GW88255
GW81086 - II 3 G – Ex nA IIB T4 Gc II 3D- Ex tc IIIB T55°C Dc IP65

Atex IEC309 Plugs & Interlock Sockets Zone 22(D) - IP67


Vertical Interlock
Ex tc IIIC T40 Dc X Plugs - 60 Atex Sockets - 67 Atex
60 Atex Amp Rating Poles Rated Voltage Reference H IP67 IP67
GW678-
2P+E 230V 6 GW67873 GW60604
16A 3P+E 6 GW67877 GW60608
400V
3P+N+E 6 GW67878 GW60609
2P+E 230V 6 GW67884 GW60615
32A 3P+E 6 GW67888 GW60619
400V
3P+N+E 6 GW67889 GW60620
67 Atex
GW606- 2P+E 230V 6 GW67896 GW60627
63A 3P+E 6 GW67900 GW60631
400V
3P+N+E 6 GW67901 GW60632

Atex PAINTED ENCLOSURES IP66


Zone 2(G) Zone 22(D)
Enclosure Internal Pack/Carton Chassis Box
Code Dimensions(mm) Qty Plates QTY
GW76291 91 x 91 x 54 40 - -
GW76292 128 x 103 x 57 32 GW76272 10
GW76293 155 x 130 x 58 24 GW76273 10
GW76294 178 x 156 x 75 16 GW76274 10
GW76295 239 x 202 x 85 8 GW76275 5
GW76296 294 x 244 x 114 4 GW76276 5
GW76297 392 x 298 x 149 1 GW76277 5
c/w kit for external earthing Atex Class: II 3GD Ex nA IIC Gc Ex tc IIIC Dc -20°C ≤ Ta85 °C U

Note: FLP Discounts Apply


FLP 6
EXPLOSION PROOF LIMIT SWITCHES IP65
Ex II 2G Exed II CT6 Roller Lever Forked Roller Lever Push Button Push Roller

Code BZX51-6D BZX51-6S BZX51-6Z BZX51-6L


Contacts: 1NO + 1NC. 6A@380VAC. Cable entry: M20 c/w cable gland. Suitable for: Zone 1 & 2. Group IIA, IIB, IIC class T6 or below

Roller Limit Switch


Code Description Enclosure Size Cable Entries
LSWR80 Roller Limit Switch 120x120x90 1 x Side (20mm)
Contacts 1NO+1NC. 10A@250VAC

PULLWIRE CONVEYOR TRIP SWITCH IP45


CTSFLP-D

190mm

130mm
190mm

130mm

LOCK LOCK
STOP STOP
80mm

BELT 80mm BELT

300mm 300mm

Code Description Amps Weight Cable Entries


CTSFLP-S Single Ended Trip Switch 10A 12kg 1 x Side 20mm
CTSFLP-D Double Ended Trip Switch 10A 18kg 1 x Side 20mm
CTSFLP-S Suitable for: Zone 1 & 2. Group IIA, IIB, IIC class T6. Contacts: 1NO + 1NC. 10A@250VAC Per End
Rope
Accessories

Code PWR SB209331/6 SB209332/6.5 SB209333/M8 SB209336/8


Description Steel Wire. PVC sheathed Thimble Clamp Eye bolt Tensioner
rope 100 metre 6mm 6.5mm M8 8mm
Ø5mm
Red MET

EXPLOSION PROOF PLUGS & SOCKETS IP66


Material: GRP (Glass Fibre Reinforced Polyester Resin
Suitable for use in: Zone1 & Zone 2
Zone 21 & Zone 22
Explosion Protection:
112 GD EX de IIC T6G6 / EX ED A21 T80°C IP66

Plug & Socket


Rated Rated
Current (A) Voltage (V) Poles Plug Socket Coupling Set
200 - 250 2P+E BCZ8060-16/250/3P/T BCZ8060-16/250/3P/Z BCZ8060-16/250/3P/L
16A 380 - 415 3P+N+E BCZ8060-16/415/5P/T BCZ8060-16/415/5P/Z BCZ8060-16/415/5P/L
480 - 500 3P+E BCZ8060-16/500/4P/T BCZ8060-16/500/4P/Z BCZ8060-16/500/4P/L
200 - 250 2P+E BCZ8060-32/250/3P/T BCZ8060-32/250/3P/Z BCZ8060-32/250/3P/L
32A 380 - 415 3P+N+E BCZ8060-32/415/5P/T BCZ8060-32/415/5P/Z BCZ8060-32/415/5P/L
480 - 500 3P+E BCZ8060-32/500/4P/T BCZ8060-32/500/4P/Z BCZ8060-32/500/4P/L
200 - 250 2P+E BCZ8060-63/250/3P/T BCZ8060-63/250/3P/Z -
63A 380 - 415 3P+N+E BCZ8060-63/415/5P/T BCZ8060-63/415/5P/Z -
480 - 500 3P+E BCZ8060-63/500/4P/T BCZ8060-63/500/4P/Z -

7 FLP
ATEX WALL MOUNTING ENCLOSURES IP66
Ex e IIC Gb Wall Mounting Enclosures
Ex tb IIIC Db
Mild Steel Grey Electric Orange 304L Stainless Size (mm)
H x Wx D Locks Hinges
LOM 12ATEX 3060U
ATEX94/9/CE ATX0302515-G ATX0302515-O ATX0302515-INX 300 x 250 x 150 1 2
ATX0403020-G ATX0403020-O ATX0403020-INX 400 x 300 x 200 1 2
ATX0404020-G ATX0404020-O ATX0404020-INX 400 x 400 x 200 1 2
ATX0504020-G ATX0504020-O ATX0504020-INX 500 x 400 x 200 2 2
ATX0604025-G ATX0604025-O ATX0604025-INX 600 x 400 x 200 2 2
ATX0606025-G ATX0606025-O ATX0606025-INX 600 x 600 x 250 2 2
ATX0705025-G ATX0705025-O ATX0705025-INX 700 x 500 x 250 2 2
ATX0806030-G ATX0806030-O ATX0806030-INX 800 x 600 x 300 2 2
ATX1008030-G ATX1008030-O ATX1008030-INX 1000 x 800 x 300 3 3
• Zone 1 & 2, Zone 21 • Grey RAL7035 - Mild Steel • Polished 304 L Stainless Steel
• -20ºC to +60ºC • Electric Orange RAL2000 - Mild Steel • Include chassis plate & 4 wall brackets

EXPLOSION PROOF JUNCTION & TERMINAL BOXES


Ex II 2G Ex e II T6 Aluminium Terminal Boxes IP65 - Material: Aluminium Alloy, Yellow Powder coated
Size (mm) No. of Terminals Fitting into box No. of No. of
Code LxWxD rows entries
2.5mm2 4mm2 6mm2 10mm2 16mm2
BXJ-E-1 190 x 132 x 127 20 18 15 12 10 1 2 bottom
BXJ-E-2 190 x 190 x 127 20 18 15 12 10 1 2 bottom
BXJ-E-3 250 x 190 x 127 30 28 22 18 15 1 3 bottom
BXJ-E-4 250 x 250 x 127 60 56 44 36 30 2 3 bottom
BXJ-E-5 300 x 200 x 150 80 72 60 48 – 2 4 bottom
• Suitable for use in: Zones 1 & 2, 21 & 22
• Terminals not included
• For use with Atex approved terminals
• Cable Entries: M20 x 1.5
Ex II 2G Ex e II T6 Polyester Terminal Boxes IP65 - Material: Glass fibre reinforced Polyester resin
Size (mm) No. of Terminals Fitting into box No. of No. of
Code LxWxD entries
2.5mm2 4mm2 6mm2 10mm2 16mm2 rows
BXJ8050-1 139 x 110 x 98 12 11 9 — — 1 2 bottom
BXJ8050-2 220 x 130 x 109 25 23 18 15 — 1 2 bottom
BXJ8050-3 260 x 179 x 120.5 30 27 22 18 15 1 3 bottom
BXJ8050-4 360 x 220 x 122 44 40 33 26 22 1 4 bottom
BXJ8050-5 360 x 360 x 122 88 80 66 52 44 2 4 bottom
• Suitable for use in: Zones 1 & 2, 21 & 22
• Terminals not included
• For use with Atex approved terminals
• Cable Entries: M20 x 1.5
Engineering Plastic Die-Cast Aluminium
Code BXJ8050-20B/6-4 BHD51-G3/4I BHD-D/M25
Type Terminal box Lightning Terminal Box Terminal Box
Material Glass fibre reinforced plastic Aluminium Alloy, powder-coated
EX-Mark II 2G Exe II T6 II 2G Exd II BT6 / CT6
BXJ8050-20B/6-4
Certificates PTB 03 ATEX 1021 PTB 06 ATEX 1013
Gland Size M25 x 1.5 G3/4 (not incl.) M25 x 1.5 (not incl.)
Terminals Posts 0.2-2.5mm² x 6 Posts 0.2-2.5mm² DIN 2.5mm² x 6
Size 120 x 120 x 60mm Ø110 x 110H Ø110 x 71H
BHD-D/M25
Suitable for Zone 1, 2, 21 and 22
Ideal for IIA, IIB and T6 Areas
BHD51-G3/4I Temperature Range: -20˚C to +55˚C

FLP 8
EXPLOSION PROOF CONTROL STATIONS IP65
Code Description Gland Enclosure Size
Size H x W x D (mm)
BZA8050-K1 On/Off Selector Switch 1 x N/O (10A) M25 107 x 85 x 87
BZA8050-A1-G Start Pushbutton 1N/O M25 107 x 85 x 87
-K1 -A1-R -A1-C
BZA8050-A1-R Stop Pushbutton 1 N/C M25 107 x 85 x 87
BZA8050-A1-C Emg. Stop Twist to release 1N/C M25 107 x 85 x 87
BZA8050-A2-C Emg. Stop (Twist to release 1N/C) & Start M25 139 x 85 x 87
Pushbutton 1N/O
-A2-C -A2-R/G -A1-G
BZA8050-A2-R/G Start/Stop 1N/O & 1N/C M25 139 x 85 x 87
BZA8050-A3-R/G/L Start/stop and LED pilot light c/w 1N/O + 1N/C per M25 185 x 85 x 87
button
BZA8050-A3-R/G/E Start/stop and emergency stop (twist to release) M25 185 x 85 x 87
c/w 1N/O + 1N/C per button
BZA8050-A3-R/G/S Start/stop & selector 3 position stay put switch c/w 1NO + M25 185 x 85 x 87
1NC per button (switch can be used as auto-off-man)
-A3-R/G/E -A3-R/G/L -A3-R/G/S
Explosion Protection: Ex II 2G Exed II CT6 Rated Working Voltage: 220VAC/380VAC
Material: Glass fibre reinforced polyester Rated Working Current: 10A
ATEX Classification Group II Category 2GD. Suitable for Zone 1, 2 and 21, 22 locations.
Explosion Proof - On/Off Switches for Zone 2,21 & 22
202271EX 1 Lever 1 WAY 16A@250V Switch IP66 M25 80 x 62 x 38
202282EX 2 Lever 1 WAY 16A@250V Switch IP66 M25 80 x 62 x 38
202276EX 1 Lever 2 WAY 16A@250V Switch IP66 M25 80 x 62 x 38

EXPLOSION PROOF PUSHBUTTONS & PILOT LIGHTS


Suitable for use in
BZA8050 Control
Stations

2-Position stay-put

Selector Switch EMG-Stop Twist EMG-Stop


Colour Pushbutton Flush Pilot Light Head Release Push/Pull Button On/Off Key Switch
Red ● EX8050-R EX8050-PLR EX8050-SS EX8050-EMG EX8050-40093 EX8050-KS
Green ● EX8050-G EX8050-PLG
Yellow ● EX8050-Y EX8050-PLY
White ● – EX8050-PLW
Contact Blocks LED Lamp Blocks Isolating Switch On/Off

Description Code Description Code Description Code


1N/O EX8050-NO 24VAC EX8050*-24VAC 2 Pole 10A EX8050-2P
1N/C EX8050-NC 110VAC EX8050*-110VAC 4 Pole 10A EX8050-4P
230VAC EX8050*-230VAC
*Add colour of lamp to code: ● R (Red), ● G (Green), ● Y (Yellow), ● W (White)

9 FLP
FLAMEPROOF CONTROL STATIONS
1 Way Control Stations - Zone 1 Group IIA, IIB, IIC
PBS71
Code Cast Iron Description Enclosure Size Code
PBS71-START-* Start Station b
PBS71-1-* Emergency Stop (spring return) b
PBS71-2-* Padlockable Stop Station b
PBS71-3-* Emergency Stop (push/pull) b
PBS71-6-* Emergency Stop Padlockable b
CT/KMS-93-† Mining Key Switch a
*Add ‘D’ for 1 x Top & 1 x Bottom 20mm entries, ‘B’ for 2 x 20mm bottom entries
†SC = shuttle car key, CM = continuous miner, DV = feeder bunker

CT/KMS-93 2 Way Control Stations


PBS72-* Start/Stop Station b
PBS72-3-* Emergency Stop (push/pull)/Start b
PBS72 *Add ‘D’ for 1 x Top & 1 x Bottom 20mm entries, ‘B’ for 2 x 20mm bottom entries
Enclosure Size Code: H x W x D (External) a = 120 x 120 x 90 b = 144 x 100 x 75
RBS-81-2 RBS-85 1 & 2 Way Fabricated FLP Control Stations - Material: 350wA - Silver Cadium Plated
Description Base Size (mm) Weight Cable Entries 20mm
Code L x H x Ø
RBS-81 Start Station 125 x 125 x 150 4.5kg 1 x Top & 1 x Bottom
RBS-81-2 Start/Stop Station 125 x 125 x 150 4.5kg 1 x Top & 1 x Bottom
RBS-82 Emergency Stop (spring return) 125 x 125 x 150 4.5kg 1 x Top & 1 x Bottom
RBS-83 Padlockable Stop Station 125 x 125 x 150 4.5kg 1 x Top & 1 x Bottom
RBS-84 Emergency Stop (push/pull) 125 x 125 x 150 4.5kg 1 x Top & 1 x Bottom
RBS-85 Emergency Stop Padlockable 125 x 125 x 150 4.5kg 1 x Top & 1 x Bottom
RBS-86 Mining Key Switch 125 x 125 x 150 4.5kg 1 x Top & 1 x Bottom
RBS-84 RBS-86 Zone 1 Group IIA, IIB, IIC
Ex d 1T4 Intertrunk - Material 300WA Steel
Code Description Size (mm)
H x L x W
Intertrunk 2 sides open c/w 32mm flanges with
INTTRUNK 210 x 160 x 163
4x 14mm holes

Ex d 1T4 Flameproof Mains Failure Indicator & Siren


Code Description Size (mm)
H x L x W
MAIN-FC Voltage Monitor with Flasher & Siren 260 x 160 x 185
• Monitoring Voltage 230VAC
• Battery backup 4 hours run time on mains failure
• Flasher & Siren on when mains fail
Flameproof Jet Fan Enclosure - 1000V with Victor Socket - 250A
Code Description Size (mm)
H x L x W
JETFAN-E1 Jet fan panel wired with Victor socket 250 x 250 x 153
• Start/Stop Buttons
• 3 x Terminals with Diode

Ex d I/IIB + H2 Flameproof Battery & Breaker Box


Code Description
Description Size (mm)Size (mm)
H x L xHWx L x W
BOXBATT-12V Flameproof
Flameproofenclosure
enclosuresuitable
for battery
for 12V
battery
Ah 12V 35-100Ah525 x 317 525
x 221x 317 x 221
Note: Battery Box without battery. For Batteries see page 91
Flameproof Breaker Box
Code Description
Description Size (mm)Size (mm)
H x L xHWx L x W
BOXBREAK-600A Flameproof enclosure for breaker 600A, 1000V 525 x 317 x 221
• Circuit breaker Box complete with 600A,1000V, 3 Pole Terasaki Breaker
• Cable Entries 5 x M32

FLP 10
FLAMEPROOF ISOLATORS
Polyester Enclosed Isolators - Padlockable 8mm - Rated working voltage: 220VAC/380VAC
Code Description Entry Size (mm)
Lx H xW
BZZ8050-16/2 16A 2-Pole Isolator Padlockable 2 x M25 139 x 110 x 109
BZZ8050-16/3 16A 3-Pole Isolator Padlockable 2 x M25 139 x 110 x 109
BZZ8050-32/2 32A 2-Pole Isolator Padlockable 2 x M25 220 x 130 x 109
BZZ8050-32/3 32A 3-Pole Isolator Padlockable 2 x M25 220 x 130 x 109
-16/2 / -16/3 • Explosion protection: Ex II 2G Exed II CT6 • Material: Glass fibre reinforced polyester
-32/2 / -32/3
ATEX Classification Group II Category 2GD. Suitable for Zones 1, 2 and 21, 22 locations
Diecast Enclosed Isolators - Padlockable 8mm
Code Description Enclosure Size Cable Entries
Code
ISO80/1/20 20 Amp 2 Pole Isolator a 1 x Top & 1 x Bottom
ISO80/3/20 20 Amp 3 Pole Isolator a 1 x Top & 1 x Bottom
ISO80/3/32 32 Amp 3 Pole Isolator a 1 x Top & 1 x Bottom
ISO160/3/32 32 Amp 3 Pole Isolator g 2 x Bottom
ISO80
ISO160/3/40 40 Amp 3 Pole Isolator g 2 x Bottom
ISO160/3/63 63 Amp 3 Pole Isolator g 2 x Bottom
ISO160/3/80 80 Amp 3 Pole Isolator g 2 x Bottom
Enclosure Size Codes: H x W x D (External), a = 120 x 120 x 90, g = 210 x 150 x 135.
ISO160 Zone 1 Group IIA,IIB,IIC.
Fabricated Enclosed Isolators - Padlockable 8mm - Material 350WA - Silver Cadium Plated
Code Description Size (mm) Weight Cable Entries 20mm
Padlockable Ø x H
RIS25/2P 25 Amp 2 Pole Isolator 150 x 120 4.5kg 1 x Top & 1 x Bottom
RIS25/3P 25 Amp 3 Pole Isolator 150 x 120 4.5kg 1 x Top & 1 x Bottom
RIS32/2P 32 Amp 2 Pole Isolator 150 x 120 4.5kg 1 x Top & 1 x Bottom
RIS32/3P 32 Amp 3 Pole Isolator 150 x 120 4.5kg 1 x Top & 1 x Bottom
RIS40/3P 40 Amp 3 Pole Isolator 200 x 150 8.0kg 1 x Top & 1 x Bottom
RIS63/3P 63 Amp 3 Pole Isolator 200 x 150 8.0kg 1 x Top & 1 x Bottom
RIS80/3P 80 Amp 3 Pole Isolator 200 x 150 8.0kg 1 x Top & 1 x Bottom
Zone 1 Group IIA, IIB, IIC

FLAMEPROOF JUNCTION BOXES


Flameproof Junction Boxes -
No of Cable Size
Code Description Entries Ø x H
KBE2M20L-2 K-Box - Empty with 2xM20 Hole 2 x M20 145 x 104
KBE2M25L-2 K-Box - Empty with 2xM25 Hole 2 x M25 145 x 104
KBE4M20L-2 K-Box - Empty with 4xM20 Hole 4 x M20 145 x 104
KBE4M25L-2 K-Box - Empty with 4xM25 Hole 4 x M25 145 x 104

OTHER FLAMEPROOF EQUIPMENT


Ex d1/II B
Flameproof Level Line Lazer
Description Size Watts
Code Ø x H
LLL24-HOR Flameproof Level Line Laser - Horizontal 12/24VDC 112 x 148 1W
LLL24-VER Flameproof Level Line Laser - Vertical 12/24VDC 112 x 148 1W
Ex d1/II B Flameproof Volt/Amp/Hour Meter
Description Size
Code Ø x H
VMETFLP-50V Flameproof Volt Meter 0 - 50VDC 112 x 148
AMETFLP-50A Flameproof Amp Meter 0 - 50ADC 112 x 148
VMETFLP AMETFLP HMETFLP HMETFLP-24V Flameproof Hour Meter 12 - 24VDC 112 x 148

11 FLP
FLAMEPROOF STARTERS
Zone 1 Group IIA, IIB, IIC Direct On Line Starter – No Terminal Box
AC3 kW Overload D.O.L. Enclosure With Enclosure Coil Voltage
400V 525V Range Code Size Code Isolator Size Code AC
4 5.5 7-10A FDL09 c /S d
5.5 7.5 9-13A FDL12 c /S d
7.5 10.5 12-18A FDL18 c /S d
11 15 17-25A FDL25 d /S e U = 240V
(170-280V)
15 18.5 23-32A FDL32 d /S e
18.5 22 33-50A FDL40 f /S f N = 415V
(291-465V)
22 30 33-50A FDL50 f /S f
SF = 550V
30 37 43-65A FDL65 f /S f (467-605V)
37 45 54-80A FDL80 f /S f
45 55 83-90A FDL95 f /S f
Enclosure Size Codes: H x W x D (External)
c = 210 x 150 x 115, d = 320 x 210 x 190, e = 320 x 150 x 135, f = 450 x 330 x 220
Ex d1 Flameproof Starter Panel - 525/100V Dual Voltage
Code Description Internal Sizes (mm)
L x H xW
FLS-XLW-*A Anglo Spec Starter Panel with large round window 280 x 280 x 220
FLS-XSQ-*S Sasol Spec Starter Panel with square window 280 x 280 x 220
(Waterproof panel) IP65
FLS-XSM-*E Exxaro Spec Starter with small round window
380 x 300 x 220
FLS-XSM-* Starter Panel with small round window 280 x 280 x 220
FLS-XNN-* Starter Panel without window 280 x 280 x 220
* Add KW to Code Range: 3.7KW, 4KW, 5.6KW, 7.5KW, 11KW, 15KW, 18.5KW, 22KW, 30KW, 37KW
S for Sasol Spec, A for Anglo Spec and E for Exxaro Spec
Mine Specifications
• Sasol Spec Starter Enclosure: Includes Small window with O-ring, Contactor, M20 & Transformer.
• Anglo Spec Starter Enclosure: Includes M/R31 Big window, Contactor, M20, Transformer with 1000V fuse
holders & Victor socket.
• Exxaro Spec Starter Enclosure: M/R401 with contactor, M20, Transformer with 1000V fuse holders
& Victor socket
Ex d1 Flameproof Camera - Supply Volts 12/24VDC
Description Size (mm)
Code Ø x H
FCA-CAM-1 Flame Proof Camera + 70mm Apeture 112 x 93
• 7.5” Screen c/w 8m cable & quick connectors
• Camera Range ± 15 meters with infra-red LEDs
Ex d1 Flameproof Gulley Boxes
Code Description Size (mm)
H x L x W
GULL-101 Gulley Box Incomer, Main & Feeder Compartments 730 x 988 x 268
GULL-102 Gulley Box Incomer, Main & Feeder Compartments 986 x 943 x 300
GULL-103 Gulley Box Incomer, Main & Feeder Compartments 1010 x 650 x 250
• Can be customised to user specification.
• All other panels can be made to order with the enquiry form supplied

Ex d 1T4 Flameproof Compressor Panel - Dual Voltage 525/1000V System


Code Description Internal Sizes (mm)
H x L x W
COMP-FP-37 Compressor Panel + Window 18.5 - 30kW 380 x 300 x 220
COMP-FP-60 Compressor Panel + Window 37 - 60kW 435 x 700 x 220
COMP-FP-150 Compressor Panel + Window 90 - 150kW 585 x 435 x 226
• Complete with Circuit Breaker, Contactor, Electronic Overload & Transformer
• Cable Entries 5 x M32

FLP 12
FLAMEPROOF ACCESSORIES
Adaptor Plates & Socket Blocks
Code Description
APLT-3.3 3,3-kVA Adaptor Plate for Transformer Box
APLT-6.6 6,6-kVA Adaptor Plate for Transformer Box
SOC-AP40 Socket Adaptor with M40 Entry
3.3/6.6kVA Adaptor SOC-AP50 Socket Adaptor with M50 Entry
90° Socket SOC-APV250 Socket Adaptor (Intertrunk to Proof/Victor 250A socket)
Adaptor SOC-AP90D 90° Socket Adaptor

Socket Adaptor

FLAMEPROOF INDICATION LIGHTS


Live Line Indicators - 1000V Indicator Lights LED Indication Lights
Size: Ø 85mm x 25mm Thread Size: M25
Thread Size: M25 Size: Ø38mm

c/w male & female connectors


Code Description Code Description Colour Code
FLP-EV-1KV 3-LED Live Line FLP-EP2-24 2-Row Cluster Light Red FLP-EA-R*
Indicator In Brass Body (Red & Green) 12/24VDC Blue FLP-EA-BL*
•1000VAC FLP-EP3-24 3-Row Cluster Light Green FLP-EA-GN*
•RED Light (Red, Green & Amber) 12/24VDC White FLP-EA-WH*
•M25 Cable Entry Amber FLP-EA-A*
•Size: Ø60 x 110(L)mm *Add voltage: 24 (12/24VDC), 110 (110VAC) or 230 (230VAC)

FLAMEPROOF PUSH BUTTONS


Head Size:
25(H) x 30(Ø)mm
Body Size: 80mm

Description Start Stop Test Reset


Mounting Hole - M20 PBUTM20-ST PBUTM20-STP PBUTM20-TEST PBUTM20-RES
Mounting Hole - M25 PBUTM25-ST PBUTM25-STP PBUTM25-TEST PBUTM25-RES
Contact 10A@240V 1NO 1NC 1NO 1NO
Waterproof
Push Buttons
Head Size:
32.5(H) x 40(Ø)mm
Body Size: 80mm

Description Start Stop Test Reset


M20 PBUTM20-STWP PBUTM20-STPWP PBUTM20-TESTWP PBUTM20-RESWP
M25 PBUTM25-STWP PBUTM25-STPWP PBUTM25-TESTWP PBUTM25-RESWP
Contact 10A@240V 1NO 1NC 1NO 1NO
Emergency Stop
Push Buttons
Head Size:
43(H) x 60(Ø)mm
Body Size: 80mm Push - Pull Push - Pull
Description E/Stop E/Stop Lockable
M20 PBUTM20-ES PBUTM20-ESLK
M25 PBUTM25-ES PBUTM25-ESLK
Contact 10A@250V 1NC 1NC
For additional contacts refer to Page 190

13 FLP
TOXIC GAS SENSOR
Toxic Gas Sensors - Not Explosion Proof Gas Sensor
c/w gas sensor with gasket, calibrated 4-20mA digital transmitter Wheatstone bridge type combustible gas sensor
board and mounting posts. Gasket sensor diameter: 32.3mm Sensor diameter: 20.25mm

Colour Code Type


Code Type
Carbon Monoxide CH-A3-BF CH-A3-BF Explosive Gas Pellistor
CO-BF-* Green
COMPLETE UNIT Hydrogen Sulphide 440P55 PCB socket for Pellistor
H2S-BE-* Orange
S02-BE-1 Sulphur Dioxide Red CH-A3-BF detects: Propane, Ethylene, Nonane,
Designed for Acetylene, Butane, Isobutylene, Hydrogen, n-Pentane
*Add sensor range to code: 1 (0-500ppm), 2 (0-2000ppm)
mounting in any and Carbon Monoxide
Input voltage: 10-30VDC (loop powered)
enclosure Pellistor and PCB Socket to be ordered separately
Connection: 2-Pin Molex (22-27-2021)
440P55 EX II 2G Ex d IIC T4 SIRA 07 ATEX 1088X
CE Approval: BS EN 61326 (Industrial)

EXPLOSION PROOF FANS


Explosion Proof IP55 - 230VAC, Maximum Operating Temperature 135°C
Explosion Flow Size (mm) Grill
Proof Fans kW Volts Rate H x WxØ Code
OW354 0.12 230 900m3/h 340 x 340 x 260 OW595
OW355 0.14 230 1500m3/h 390 x 390 x 312 OW596
OW356 0.16 230 2250m3/h 460 x 460 x 365 OW597
OW350 0.18 230 2900m3/h 510 x 510 x 415 OW598
OW351 0.21 230 4500m3/h 630 x 630 x 515 OW599
OW361* 0.23 2900m3/h 510 x 510 x 415 OW598
Ex-Atex Approved N.03 Atex 251
Fan Grill
*Supply Voltage: 400VAC-3PH FAN

EXPLOSION PROOF ACCESSORIES


Class 1 Zone 1 Cert. MS787/J608 Class 1 Zone 1 Compression Glands
For use on Exd equipment to SABS 314. S.W.A. Glands Cert. MS787/J206 Size Code
Size Code 00 FCG-00
0 FSG-0 0 FCG-0
1 FSG-1 1 FCG-1
2 FSG-2 2 FCG-2
3 FSG-3 3 FCG-3
Supplied with Shroud 4 FSG-4 4 FCG-4
Cable Glands Explosive Areas IP68 For Armored Cable Compression Glands
5 Bar with strain relief black Polyamide Double Seal IP66 IP65
Group II Category 2GD, ATEX1087X Size Code Size Code
Code Size Cable Size Ø 20mm EPG-709002 20mm EPC-706001
124M20EX03 M20 6-12mm 25mm EPG-709004 25mm EPC-706002
124M25EX03 M25 13-18mm 32mm EPG-709006 32mm EPC-706003
124M32EX03 M32 18-25mm Ex II 2G Exd IIC 40mm EPG-709008 Ex II 2G Exe II 40mm EPC-706004
Hole Plugs
L

Size Code Length Code Length Code Length


Alum. Alloy L (mm) Brass Nickel Plated L (mm) Plastic L (mm)
20 BA-715001 17 BPT-715011 17 BZ-714002 10
25 BA-715002 17 BPT-715012 17 BZ-714003 12
32 BA-715003 20 BPT-715013 20 BZ-714004 12
40 BA-715004 20 BPT-715014 20 BZ-714005 14.5
50 BA-715005 20 BPT-715015 20 BZ-714006 15
Ex II 2G Exd IIC Ex II 2G Exe II
Material: Aluminium Alloy, carbonate Steel Zinc-Plated

FLP 14
FLAMEPROOF ACCESSORIES
90° Glands & Keeper Plates
GLND900 Code Description Size Ø
GLND90050.8 90° Compression Glands & Keeper Plates FLP 50.8mm
GLND90063.5 90° Compression Glands & Keeper Plates FLP 63.5mm
GLND90076.2 90° Compression Glands & Keeper Plates FLP 76.2mm
Ø
Flameproof Bushings

BFLPM32MOT BFLPM32THR BFLPM20THR


Code Description
BFLPM32MOT M32 Motor Bushing with M12 Studs
BFLPM20THR M20 through Bushing with 6 x 1.5mm² Wires (1m Total Length)
BFLPM25THR M25 through Bushing with 12 x 1.5mm² Wires (1m Total Length)
BFLPM32THR M32 through Bushing with 20 x 1.5mm² Wires (2m Total Length)
Adaptors Reducers Blanking Plug

Code Description Code Description Code Description


ADA3/4NPTM25F ¾ NPT to M25 Adaptor REDM25M16F M20 to M16 reducer BPLGM20F M20 Blanking Plug
ADAM32M40F M32 to M40 Adaptor REDM25M20F M25 to M20 reducer BPLGM25F M25 Blanking Plug
ADAM25M32F M25 to M32 Adaptor REDM32M25F M32 to M25 reducer BPLGM32F M32 Blanking Plug
REDM40M32F M40 to M32 reducer BPLGM40F M40 Blanking Plug
REDM50M25F M50 to M25 reducer BPLGM50F M50 Blanking Plug
REDM63M50F M63 to M50 reducer
High Security Key Switches
Ronnis Key Switches Abloy Key Switch Barrel Abloy
Key
Switch
Brass Body

Code Description Code Description Code Description


Ronnis Keyswitch KEYSW-AB3K Abloy key switch barrel only with 3 keys KEYSW-AB1 Abloy key switch
KEYSW-SR-1
(Spring Return) x 2 Keys KEYSW-RB Roof bolter key switch barrel & 3 keys (RB engraved) barrel & brass body
Ronnis Keyswitch KEYSW-SC Shuttle car key switch barrel & 3 keys (SC engraved) & 1NO 10A Contact
KEYSW-SP-2 incl 3 keys
(Stay Put) x 2 Keys KEYSW-CM Continuous miner key switch barrel & 3 keys (CM engraved)
KEYSW-PDS PDS key switch barrel & 3 keys (PDS engraved)
Abloy Keys Only
KEY-AB Abloy Keys Only - 3 Keys
KEY-ABMAS Abloy Master Key - 3 Keys
Flameproof Quick Connectors - with or without cable
Code Description Wire Length
FQC-PL-*-2M Quick Connector Plug (Male) 2 meters
FQC-SC-*-3M Quick Connector Socket (Female) 3 meters
FQC-SC-*-6M Quick Connector Socket(Female) 6 meters
* Add no. of way to code: 04, 05, 19

F114 1000V Fuse Holders & Fuses


Code Description
P114 1000V Fuse Holder For 10 x 85 Fuse
F602
F602* 1500V Fuse Size 10 x 85 Fuse
L * Add Amps to code: 2A, 4A, 6.3A, 10A, 16A

15 FLP
MINING STARTERS - NON FLAMEPROOF IP54
Mining Winch Starters Mono Winch Starters
All winch starters are standard with a system voltage All winch starters are standard with a system voltage of
of 525VAC 3PH supplied in an IP54 mild steel enclosure. 525VAC 3PH, supplied in an IP54 mild steel enclosure.
Code Description Code Description
WINCHS-22* 22KW at 525V N/FLP MONWS-04* 4KW at 525V N/FLP
WINCHS-37* 37KW at 525V N/FLP MONWS-05* 5.5KW at 525V N/FLP
WINCHS-45* 45KW at 525V N/FLP MONWS-07* 7.5KW at 525V N/FLP
WINCHS-55* 55KW at 525V N/FLP MONWS-11* 11KW at 525V N/FLP
*Add Control Volts to Code: MONWS-15* 15KW at 525V N/FLP
F(110VAC), U(240VAC), SF(550V) MONWS-18* 18.5KW at 525V N/FLP
Conveyor Starters MONWS-22* 22KW at 525V N/FLP
MONWS-30* 30KW at 525V N/FLP
Code Description MONWS-37* 37KW at 525V N/FLP
CONS-11* 11KW at 525V N/FLP *Add Control Volts to Code:
CONS-15 15KW at 525V N/FLP F(110VAC), U(240VAC), SF(550V)
CONS-18* 18.5KW at 525V N/FLP Mining Pump Starters
CONS-22* 22KW at 525V N/FLP All pump starters are standard with a system voltage of
CONS-30* 30KW at 525V N/FLP 525VAC 3PH, supplied in an IP54 mild steel enclosure.
CONS-37* 37KW at 525V N/FLP Code Description
CONS-45* 45KW at 525V N/FLP PUMPS-07* 7.5KW at 525V N/FLP
CONS-55* 55KW at 525V N/FLP PUMPS-11* 11KW at 525V N/FLP
CONS-75* 75KW at 525V N/FLP PUMPS-15* 15KW at 525V N/FLP
*Add Control Volts to Code: PUMPS-18* 18.5KW at 525V N/FLP
F(110VAC), U(240VAC), SF(550V) PUMPS-22* 22KW at 525V N/FLP
PUMPS-30* 30KW at 525V N/FLP
Mining Vacuum Pump Starters
PUMPS-37* 37KW at 525V N/FLP
All vacuum pump starters are standard with a system PUMPS-45* 45KW at 525V N/FLP
voltage of 525VAC 3PH, supplied in an IP54 mild steel PUMPS-55* 55KW at 525V N/FLP
enclosure. *Add Control Volts to Code: F(110VAC), U(240VAC),SF(550V)
Code Description DOL Mining Starters
VACPS-07* 7.5KW at 525V N/FLP
Code Description
VACPS-11* 11KW at 525V N/FLP
DOLMS-04* DOL 4KW at 525V N/FLP
VACPS-15* 15KW at 525V N/FLP DOLMS-05* DOL 5.5KW at 525V N/FLP
VACPS-18* 18.5KW at 525V N/FLP DOLMS-07* DOL 7.5KW at 525V N/FLP
VACPS-22* 22KW at 525V N/FLP DOLMS-11* DOL 11KW at 525V N/FLP
VACPS-30* 30KW at 525V N/FLP DOLMS-15* DOL 15KW at 525V N/FLP
VACPS-37* 37KW at 525V N/FLP DOLMS-18* DOL 18.5KW at 525V N/FLP
VACPS-45* 45KW at 525V N/FLP DOLMS-22* DOL 22KW at 525V N/FLP
VACPS-55* 55KW at 525V N/FLP DOLMS-30* DOL 30KW at 525V N/FLP
*Add Control Volts to Code: DOLMS-37* DOL 37KW at 525V N/FLP
F(110VAC), U(240VAC), SF(550V) DOLMS-45* DOL 45KW at 525V N/FLP
DOLMS-55* DOL 55KW at 525V N/FLP
Mining Vacuum Fan Starters *Add Control Volts to Code: F(110VAC), U(240VAC),SF(550V)
All fan starters are standard with a system voltage of Mining Drill Rig Starters
525VAC 3PH, supplied in an IP54 mild steel enclosure. All drill rig starters are standard with a system voltage
Code Description of 525VAC 3PH, supplied in a steel enclosure.
FANVS-07* 7.5KW at 525V N/FLP Code Description
FANVS-11* 11KW at 525V N/FLP DRST-55* 55KW at 525V N/FLP
FANVS-15* 15KW at 525V N/FLP DRST-75* 75KW at 525V N/FLP
FANVS-18* 18.5KW at 525V N/FLP *Add Control Volts to Code: F(110VAC), U(240VAC),SF(550V)
FANVS-22* 22KW at 525V N/FLP Mining Fan Starters
FANVS-30* 30KW at 525V N/FLP All fan starters are standard with a system voltage of
525VAC 3PH with control fuse protection and 110 or
FANVS-37* 37KW at 525V N/FLP 230V for the alarm circuit.
FANVS-45* 45KW at 525V N/FLP Code Description
FANVS-55* 55KW at 525V N/FLP FANS-07* 7.5KW at 525V N/FLP
*Add Control Volts to Code: FANS-11* 11KW at 525V N/FLP
F(110VAC), U(240VAC), SF(550V) FANS-15* 15KW at 525V N/FLP
• Non-Plug-In Starters FANS-22* 22KW at 525V N/FLP
• Mining Glands fitted *Add Control Volts to Code: F(110VAC), U(240VAC),SF(550V)
• Control Circuit Protection : 550V - 2 Fuses
Note: All of the above Mining Starters can be manufactured to
: 110 or 240V - Transformer with 3 Fuses customer requirements.

FLP 16
MINING GULLEY BOXES - NON FLAMEPROOF IP54
Gulley Boxes Incomers - 250A Bus
Size (mm)
Code Description H x Wx D
Harmony Mine Spec
Top Box
800 x 280 x 185 (Vertical Box)
GBIN-250-HA-** 250A Tee Box Incomer Harmony Spec Tee Box Incomer
180 x 515 x 185 (Top Box)
Other Mines Spec
GBIN-250-*-** 250A Gulley Box Incomer 600 x 200 x 190
Incomer
GBIN-250 * Add mine to code: EX(Exxaro), DE(De Beers Consolidated Mines), PE(Petra), AA(Anglo American),
AGA(Anglo Gold Ashanti), GF(Gold Fields), HA(Harmony Gold), AP(Anglo American Amplats)
** Add control volts to code: SF(550V), Z(1000V)
Other mine
Incomer Gulley Boxes Feeders - 250A Bus
Code Description
GBFE-40-*-** 40 A Feeder box
GBFE-60-*-** 60A Feeder box

Feeder
GBFE-100-*-** 100A Feeder box

GBFE * Add mine to code: EX(Exxaro), DE(De Beers Consolidated Mines), PE(Petra), AA(Anglo American),
AGA(Anglo Gold Ashanti), GF(Gold Fields), HA(Harmony Gold), AP(Anglo American Amplats)
** Add control volts to code: SF(550V), Z(1000V)
Note: All gulley boxes incomer fitted with Terasaki integrated earth leakage circuit breaker.
Other specifications available on request

Gulley Boxes - Lighting Feeders (Transformers)


Code Description
GBFEL-S3 Lighting Transformer Box 3KVA 550V
GBFEL-S4 Lighting Transformer Box 4KVA 550V
GBFEL-S5 Lighting Transformer Box 5KVA 550V
Complete with Terasaki Incoming Circuit Breaker, Gewiss output Circuit Breakers 4 x 6A and Isolating Transformer
550V/230VAC

OTHER STARTERS - NON FLAMEPROOF


Flitting Panels Non-Flameproof - 110kW 550V Forward/Reverse DOL Starter
Code Description
FLITPAN Exxaro Spec Flitting panel
Incl. 2 x 110kW DOL Contactors, MCCB, transformers with fuse holders & terminals.
With Victor plug and New Elec WA Electronic Overload

Note: Other combinations and specifications manufactured to your order.

Heavy Duty Starter Non-Flameproof Mining Starter - 525V


Code Description Size mm
L xW xD
HDFST-*-* Heavy duty DOL fan starter 730 x 988 x 268
HDPST-*-* Heavy duty DOL pump starter 986 x 943 x 300
HDWST-*-* Heavy duty DOL winch starter 1010 x 650 x 250
* Add kW rating to code: 03(3.7kW), 05(5.5kW), 07(7.5kW), 11(11kW), 18(18.5kW), 22(22kW),
37(37kW), 45(45kW), 75(75kW),
* Add control voltage to code: F(110V) or U(240V)

17 FLP
VICTOR PLUGS & SOCKETS 650/1100VAC
Flameproof 250Amp 4 Pin Screw Type Plugs Non-Flameproof 250Amp 4 Pin Screw Type Plugs

Code Description Cable Type Code Description Cable Type


Z100001/101 Flameproof 250A 4 Pin Plug for 4mm2 41 Z7100001/101 Non-Flameproof 250A 4 Pin Plug for 4mm 2
41
Z100001/102 Flameproof 250A 4 Pin Plug for 6mm2 41 Z7100001/102 Non-Flameproof 250A 4 Pin Plug for 6mm2 41
Z100001/104 Flameproof 250A 4 Pin Plug for 16mm2 41 Z7100001/104 Non-Flameproof 250A 4 Pin Plug for 16mm2 41
Z100001/114 Flameproof 250A 4 Pin Plug for 16mm2 61A Z7100001/114 Non-Flameproof 250A 4 Pin Plug for 16mm2 61A
Z100001/115 Flameproof 250A 4 Pin Plug for 25mm2 61A Z7100001/115 Non-Flameproof 250A 4 Pin Plug for 25mm2 61A
Z100001/116 Flameproof 250A 4 Pin Plug for 35mm2 61A Z7100001/116 Non-Flameproof 250A 4 Pin Plug for 35mm2 61A
Z100001/117 Flameproof 250A 4 Pin Plug for 50mm2 61A Z7100001/117 Non-Flameproof 250A 4 Pin Plug for 50mm2 61A
Z100001/118 Flameproof 250A 4 Pin Plug for 70mm2 61A Z7100001/118 Non-Flameproof 250A 4 Pin Plug for 70mm2 61A
Z100001/126 Flameproof 250A 4 Pin Plug for 35mm2 61B Z7100001/126 Non-Flameproof 250A 4 Pin Plug for 35mm2 61B
Z100001/127 Flameproof 250A 4 Pin Plug for 50mm2 61B Z7100001/127 Non-Flameproof 250A 4 Pin Plug for 50mm2 61B
Flameproof 250Amp Non-Flameproof 250Amp
4 Pin Screw Type Sockets 4 Pin Screw Type Sockets

Code Description Cable Type Code Description Cable Type


Z100002/101 Flameproof 250A 4 Pin Socket for 4mm2
41 Z710002/101 Non-Flameproof 250A 4 Pin for 4mm 2
41
Z100002/102 Flameproof 250A 4 Pin Socket for 6mm2 41 Z710002/104 Non-Flameproof 250A 4 Pin for 16mm2 41
Z100002/104 Flameproof 250A 4 Pin Socket for 16mm2 41 Z710002/115 Non-Flameproof 250A 4 Pin for 25mm2 61A
Z100002/114 Flameproof 250A 4 Pin Socket for 16mm2 61A Z710002/116 Non-Flameproof 250A 4 Pin for 35mm2 61A
Z100002/115 Flameproof 250A 4 Pin Socket for 25mm2 61A Z710002/117 Non-Flameproof 250A 4 Pin for 50mm2 61A
Z100002/116 Flameproof 250A 4 Pin Socket for 35mm2 61A Z710002/118 Non-Flameproof 250A 4 Pin for 70mm2 61A
Z100002/117 Flameproof 250A 4 Pin Socket for 50mm2 61A
Z100002/118 Flameproof 250A 4 Pin Socket for 70mm2 61A
Z100002/126 Flameproof 250A 4 Pin Socket for 35mm2 61B
Z100002/127 Flameproof 250A 4 Pin Socket for 50mm2 61B
Flameproof 425Amp 4 Pin Screw Type Plugs Flameproof 425Amp
4 Pin Screw Type Sockets

Code Description Cable Type Code Description Cable Type


Z120001/100 Flameproof 400A 4 Pin Plug for 16mm2 41 Z120003/10 Flameproof 425A 4 Pin Socket for 150mm2 NA
Z120001/110 Flameproof 400A 4 Pin Plug for 16mm2 61A Z120003/20 Flameproof 425A 4 Pin Plug for 120mm2 NA
Z120001/111 Flameproof 400A 4 Pin Plug for 25mm2 61A Z120003/30 Flameproof 425A 4 Pin Plug for 95mm2 NA
Z120001/112 Flameproof 400A 4 Pin Plug for 35mm2 61A Z120003/40 Flameproof 425A 4 Pin Plug for 70mm2 NA
Z120001/113 Flameproof 400A 4 Pin Plug for 50mm2 61A Z120003/50 Flameproof 425A 4 Pin Plug for 50mm2 NA
Z120001/114 Flameproof 400A 4 Pin Plug for 70mm2 61A Z120003/60 Flameproof 425A 4 Pin Plug for 35mm2 NA
Z120001/115 Flameproof 400A 4 Pin Plug for 95mm2 61A Z120003/70 Flameproof 425A 4 Pin Plug for 25mm2 NA
Z120001/116 Flameproof 400A 4 Pin Plug for 120mm2 61A Z120003/80 Flameproof 425A 4 Pin Plug for 16mm2 NA
Z120001/117 Flameproof 400A 4 Pin Plug for 150mm2 61A Z120003/30 H Flameproof 425A 4 Pin Plug for 95mm2 NA
Z120001/122 Flameproof 400A 4 Pin Plug for 35mm2 61B Accessories
Z120001/123 Flameproof 400A 4 Pin Plug for 50mm2 61B
Z120001/124 Flameproof 400A 4 Pin Plug for 70mm2 61B Code Description Cable Type
Z120001/125 Flameproof 400A 4 Pin Plug for 95mm2 61B 002706 200/250A Test Plug NA
Z120001/126 Flameproof 400A 4 Pin Plug for 120mm2 61B 037001 300/425A Test Plug NA
Z120001/127 Flameproof 400A 4 Pin Plug for 150mm2 61B Note: For testing the operation of the Pilot Circuit and Live Indication.
Z120001/134 Flameproof 400A 4 Pin Plug for 70mm2 63 Dual Voltage 650/1100VAC.
Z120001/135 Flameproof 400A 4 Pin Plug for 95mm2 63
Z120001/136 Flameproof 400A 4 Pin Plug for 120mm2 63
Z120001/137 Flameproof 400A 4 Pin Plug for 150mm2 63

FLP 18
EXPLOSION PROOF LIGHTING
Ex d II C T4-Gb Flameproof Spot Lights - Material Mild Steel Zinc Plated
Ex d I 150°C Mb
Description LED Light Power Cable Size (mm)
Code Power Output mA Entry H x W x L
S1-LFP-5W-** Flameproof Spotlight 5W 49 LUX at 5m 28mA 1 x M20 195 x 171 x 166
S1-LFP-7W-** Flameproof Spotlight 7W 118 LUX at 5m 72mA 1 x M20 195 x 171 x 166
S1-LFP-12W-** Flameproof Spotlight 12W 190 LUX at 5m 111mA 1 x M20 245 x 171 x 180
*Add colour: ●R (Red), ●A (Amber), ●G (Green), C (Clear) Zone 1 & Zone 2
Zone 21 & 22
*Add Volts to Code: 12VDC, 110VAC, 230VAC EXD 11
S1
EX Terminal Box for S1 Lights - Optional for S1 Spotlight
Code Description
TBOX-S1 TBOX-S1 EX Terminal Box
Ex d1 T4 Flameproof Area Flasher with Battery Backup - 12VDC
S2
Cable Size (mm)
Code Description Watts Entry Øx H
S2-FLP-R12VDC Red Flasher Unit 12VDC c/w Battery Backup 20W 3 x M20 152 x 171
215mm max OD with Foot & Push Button
Ex d1 T4 Flameproof Flasher / Siren Combo - 8 different settings, flashings, 3 speed rotating, 4 strobe settings
Size (mm)
Code Description Watts Øx H
S3-CFLP-R* Red Flasher/Siren Combo Flameproof 7.5W / 10W 140 x 259.5
S3-CFLP-BL* Blue Flasher/Siren Combo Flameproof 7.5W / 10W 140 x 259.5
S3-CFLP-GN* Green Flasher/Siren Combo Flameproof 7.5W / 10W 140 x 259.5
S4-SFLP* Flameproof Siren Only 95dB 140 x 259.5
S3
*Add voltage to code: 24 for (24/12VDC), 220 for (110/220VAC)
Ex d1 T4 Flameproof Flashers with Keyswitch - c/w keyswitch body, lock & keys
Size (mm)
Code Description Watts H x L
S5-KFLP-R* Flasher Unit with Keyswitch Red 7.5W / 10W 140 x 252
S5-KFLP-GN* Flasher Unit with Keyswitch Green 7.5W / 10W 140 x 252
S5-KFLP-BL* Flasher Unit with Keyswitch Blue 7.5W / 10W 140 x 252
S5 *Add voltage to code: 24 for (24/12VDC), 220 for (110/220VAC)
Ex d1 T4 Flameproof Flasher Units - 160mm Max OD with Foot
Size (mm)
Code Description Watts Ø x L
S6-FLP-R* Red Flasher Units 7.5W / 10W 128 x 120
S6-FLP-BL* Blue Flasher Units 7.5W / 10W 128 x 120
S6 S6 S6-FLP-GN* Green Flasher Units 7.5W / 10W 128 x 120
S6-FLP-WH* White Flasher Units 7.5W / 10W 128 x 120
*Add voltage to code: 24 for (24/12VDC), 220 for (110/220VAC)
Flameproof Timer Light - 160mm Max OD with Foot
S7-TFP-R-24 Flameproof resin timer light Red 12/24VDC 7.5W 128 x 120
S6 S7 S7-TFP-A-24 Flameproof resin timer light Amber 12/24VDC 7.5W 128 x 120
S7-TFP-GN-24 Flameproof resin timer light Green 12/24VDC 7.5W 128 x 120

LED EXPLOSION PROOF EMERGENCY LIGHT FITTING IP65


Zone 1 & 2 40W LED-Emergency Light
Zone 21 & 22
EXD 11 Code Size Volts
BAJ52-20 340 x 300 x 125mm 220 - 240VAC
Specifications
• 2 x 20W LED • 6V, 6Ah NI-MH Battery
• EMG Time 90min • Charge Time 24H

19 FLP
FLAMEPROOF VEHICLE LIGHTS

Code S312LEDR-6-* S316LEDR-6-* HDLT24-15W HDLT24-30W


Description FLP Mini Light FLP Red LED Maxi Reverse Light FLP Small Head Light FLP Large Head Light
*Add Voltage to Code 12(12VAC/DC) or 24(24VAC/DC) 12(12VAC/DC) or 24(24VAC/DC) Voltage: 12/24VDC Voltage: 12/24VDC
Power 15W 15W 15W 30W
Size (mm) Ø112 x 112L x 120H Ø140 x 165L x 186W Ø112 x 148H Ø139 x 172H
Area Ex d I/IIC T4 / Zone 1/21/22 Ex d I/IIC T4 / Zone 1 Ex d I/II B Ex d I/II B

Code HFRL-*-* HAFC-*-* HSHC-*


Description FLP Rotating LED Flasher FLP Siren Flasher Combo FLP 5 Tone Siren
*Add Voltage to Code 36V (9-36VAC/DC) or 250V (75-250VAC/DC) 36V (9-36VAC/DC) or 250V (75-250VAC/DC) 36V (9-36VAC/DC) or 250V (75-250VAC/DC)
Power 3W 5W / 108dB 3W / 108dB
Size (mm) Ø160 x 140L 222L x 195H x 155W Ø133 x 223L x 170W
Area Ex d I/IIC T4 / IP65 Ex d I/IIC T4 / Zone 1/21/22 Ex d I/IIC T4
*Add colour to code: ● W (White), ● R (Red), ● GR (Green), ● B (Blue), ● A (Amber)

NON-FLAMEPROOF VEHICLE LIGHTS


Thread Size:
25mm

Code EHL-4LED EHL-6LED EHL-FEL-* EHL-STB-*


Description 4 x 5W LED Lamp 6 x 5W LED Loco Lamp Round LED Marker Lamp Strobe Light
Voltage 12 - 36VDC 12 - 36VDC 12 - 36VDC 12 - 36VDC
Power 20W 30W 4.2W 7.6W
Size (mm) Ø70 x 80H Ø150 x 60H Ø70 x 80H Ø90 x 70H
*Add colour to code: ● R (Red), ● GR (Green), ● B (Blue), ● A (Amber - For FEL-Range Only)

FLAMEPROOF SWITCHES FLASHER


Non-Flameproof

Code CSS-TRIP OPS/DM1-*-* LS4-* EHL-REC-*


Description FLP Coal Tip Trip Switch FLP Oil Pressure Switch FLP Level Switch Rectangular Flasher
Voltage 1NO 10A@250VAC 1NO 10A@250VAC 1NO 10A@250VAC 12 - 36VDC / 2.7W
Size (mm) Ø150 x 165H Ø68 x 160L x 103H 550/1000/1500/2000 200L x 40H x 22D
Area Ex d I/IIC T4 / Zone 1 Ex d I/IIC T4 / Zone 1 *Add colour to code:
Ex d I/IIC T4 / Zone 1
● R (Red), ● GR (Green),
Ranges - * Add Pressure to code: * Add Size (mm) to code: ● B (Blue), ● A (Amber),
10(1-10bar), 20(10-20bar), 550, 1000, 1500, 2000 ● W (White), R/G (Red &
1(0.1-1bar). * Add Contact Green Combined to be switched
Type to code: NO, NC separately)

FLP 20
FLAMEPROOF SIRENS & BEACONS
Flameproof Motorised Sirens
• Application: Class 1, 2 & 3 all groups. Division 1 and 2 areas
Min Sound
Operating Max Current
Frequency Audible at Rated
Code Voltage at Rated
(Hz) Range Voltage
Range Voltage (A) (dB@1m)
† Duty Cycle 1min on, 8min off *Duty Cycle - Continuous
EP500* 115VAC 1200 2 1000m 113 - Ex Duplo
EP500
Mono EP500* 230VAC 1200 1 1000m 113 - Ex Duplo
&
Duplo EP500† 12VAC/DC 1200 9 1000m 113 - Ex Mono
EP1500
EP500† 24VAC/DC 1200 4.8 1000m 113 - Ex Mono
Duty Cycle 30min on, 10min off
EP1500 115VAC 1600 2.6 1500m 126
EP1500 230VAC 1600 2.1 1500m 126

EP2000 115VAC 370/660 4.0 2000m 128


EP2000 EP2000 230VAC 370/660 3.0 2000m 128

Flameproof Electronic Sounder


• Maintenance free solid state sounder
• Four sounds from one unit for different applications
• High sound output with volume control
• Application: Class 1, 2 & 3 all groups. Division 1 and 2 areas
Code Description Sound Output @1m
EXS* Flameproof Multi Sounder 93-113dB
EXS Multi *Add voltage: 12VDC, 24VDC, 115VAC, 230VAC
Sounder

• High quality steel casting, precision engineered Flameproof Beacon - Xenon Strobe
• Rugged multipurpose weatherproof device Code Description Colour FPM Light
• Application: Class 1, 2 & 3, all groups. Division
1. 1 and 2 areas EXF-A* Flameproof Beacon ● Amber 110 Xenon Tube
EXF-B* Flameproof Beacon ● Blue 110 Xenon Tube
EXF-G* Flameproof Beacon ● Green 110 Xenon Tube
EXF-R* Flameproof Beacon ● Red 110 Xenon Tube
Flameproof Beacon - LED Type
EXFL-A* Flameproof Beacon ● Amber 110 LED
EXFL-R* Flameproof Beacon ● Red 110 LED
Xenon EXFL-G* Flameproof Beacon ● Green 110 LED
&
*Add voltage: 12VDC, 24VDC, 110VAC, 230VAC
LED

Flameproof Beacon and Sounder Combination - Xenon Strobe


Code Colour Light Description FPM
EXCX-A* ● Amber Xenon Tube Flameproof Sounder and Beacon 110
EXCX-B* ● Blue Xenon Tube Flameproof Sounder and Beacon 110
EXCX-G* ● Green Xenon Tube Flameproof Sounder and Beacon 110
EXCX-R* ● Red Xenon Tube Flameproof Sounder and Beacon 110
Multi Sounder &
LED Beacon Flameproof Beacon and Sounder Combination - LED Type
EXCX* EXCL-A* ● Amber LED Flameproof Sounder and Beacon 110
Multi Sounder & EXCL-G* ● Green LED Flameproof Sounder and Beacon 110
Xenon Tube
EXCL-R* ● Red LED Flameproof Sounder and Beacon 110
*Add voltage: 12VDC, 24VDC, 115VAC, 230VAC

Colours

21 FLP
EXPLOSION PROOF EQUIPMENT IP66
E2S Flameproof Manual Call Points
Code Description Duty Cycle Voltage
ECPG003 EX Break Glass Call Point Continuous Rated 24VDC
ECPG002 Call Point Spare Glass - -
ECPP002 EX Push Button Call Point Continuous Rated 24VDC
ECPG003 ECPP002 ECPT002 ECPT002 EX Tool Reset Call Point Continuous Rated 24VDC
Housing Material: Marine grade copper free LM6 Aluminium

FLAMEPROOF SIRENS & BEACONS IP67


EX11 Flameproof Sounders
Code Description Duty Sound Current Tone
Cycle Output Consumption
EXS1012 EX 11 Sounder 12VDC Continuous Rated 110db 195mA 32 Tone
EXS1024 EX 11 Sounder 24VDC Continuous Rated 110db 250mA 32 Tone
EXS1012 EXS1110 EX 11 Sounder 110VAC Continuous Rated 110db 110mA 32 Tone
EXS1220 EX 11 Sounder 220VAC Continuous Rated 110db 56mA 32 Tone
EX12 Flameproof Sounders
EXS2012 EX 12 Sounder 12VDC Continuous Rated 120db 850mA 32 Tone
EXS2024 EX 12 Sounder 24VDC Continuous Rated 120db 800mA 32 Tone
EXS2110 EX 12 Sounder 110VAC Continuous Rated 120db 180mA 32 Tone
EXS2012 EXS2220 EX 12 Sounder 220VAC Continuous Rated 120db 90mA 32 Tone
EX 05 Flameproof Beacons
Duty Light Light
Code Description Output
Cycle Source
EXB051* EX 05 Beacon 12VDC Continuous Rated Xenon Tube 5 Joule @ 1Hz
EXB052* EX 05 Beacon 24VDC Continuous Rated Xenon Tube 5 Joule @ 1Hz
EXB051
EXB053* EX 05 Beacon 110VAC Continuous Rated Xenon Tube 5 Joule @ 1Hz
EXB054* EX 05 Beacon 220VAC Continuous Rated Xenon Tube 5 Joule @ 1Hz
EX 10 Flameproof Beacons
EXB101* EX 10 Beacon 12VDC Continuous Rated Xenon Tube 10 Joule @ 1Hz
EXB102* EX 10 Beacon 24VDC Continuous Rated Xenon Tube 10 Joule @ 1Hz
EXB101 10 Joule @ 1Hz
EXB103* EX 10 Beacon 110VAC Continuous Rated Xenon Tube
EXB104* EX 10 Beacon 220VAC Continuous Rated Xenon Tube 10 Joule @ 1Hz

EX 15 Flameproof Beacons
EXB151* EX 15 Beacon 12VDC Continuous Rated Xenon Tube 15 Joule @ 1Hz
EXB152* EX 15 Beacon 24VDC Continuous Rated Xenon Tube 15 Joule @ 1Hz

EXB151 EXB153* EX 15 Beacon 110VAC Continuous Rated Xenon Tube 15 Joule @ 1Hz
EXB154* EX 15 Beacon 220VAC Continuous Rated Xenon Tube 15 Joule @ 1Hz
*Add colour: ●R (Red), ●A (Amber), ●G (Green), ●B (Blue)
EX 1105 Flameproof Beacons/Sounder Combo
Code Description Duty Sound Current Light Light
Cycle Output Consumption Output Tone
Source
EXC111* EX 1105 Combo 12VDC Continuous 110db 195mA Xenon Tube 5 Joule @ 1Hz 32 Tone
EXC112* EX 1105 Combo 24VDC Continuous 110db 250mA Xenon Tube 5 Joule @ 1Hz 32 Tone
EXC113* EX 1105 Combo 110VAC Continuous 110db 110mA Xenon Tube 5 Joule @ 1Hz 32 Tone
EXC111 EXB114* EX 1105 Combo 220VAC Continuous 110db 56mA Xenon Tube 5 Joule @ 1Hz 32 Tone
*Add colour: ●R (Red), ●A (Amber), ●G (Green), ●B (Blue)
Accessories (see H200 page 343)
Code Description
H200CAGE Flameproof Cage For H200 Siren

FLP 22
EXPLOSION PROOF SIRENS & BEACONS
Flameproof Sounders and Beacons
• Application: Class 1, 2 & 3 all groups. Division 1 and 2 areas
Max Min Sound
Operating Current at at Rated IP
Code Voltage Material Rated Voltage Rating Tone
Range Voltage (A) (dB@1m)
DB1 DB1 240VAC 240VAC ABS 30mA 103 IP66 27 Tone
DB5
DB1 24VDC 24VDC ABS 250mA 103 IP66 27 Tone
DB5 24VDC ABS 14mA 100 IP65 26 Tone
DB7 24VDC Polyester 34mA 103 IP66 27 Tone

XB8 XB8 24VDC Polyester 55mA 60F/M IP66 Beacon

Manual Callpoint IP67


Code Description
DB7 BG2 Switch Ratings: 0 to 30VDC – 5A (resistive) or 3A (inductive); 30 to 50VDC – 1A
BG2 ­(resistive) or 3A (inductive); 0 to 254VAC – 5A (resistive) or 3A (inductive).
Material: UV resistant glass reinforced polyester.
EXH 24VAC 24VAC PC/ABS 450mA 105 IP55 Horn
EXH 115VAC 115VAC PC/ABS 205mA 105 IP55 Horn
EXH 230VAC 230VAC PC/ABS 70mA 105 IP66 Horn

GR3T 24VAC 230VAC Aluminium 70mA 110 IP55 Siren


GR3T 115VAC 115VAC Aluminium 150mA 110 IP55 Siren
GR3T 24V 12-24VAC/DC Aluminium 160mA 109 IP55 Siren
Above Sirens 100% continuous rated
Aluminium Explosion Proof Beacon IP66 Xenon Tube
GR3T
Code Colour FPM Connection
FHL113-A* ● Amber 110 3/4 inch
FHL113-R* ● Red 110 3/4 inch
FHL113-G* ● Green 110 3/4 inch
*Add Voltage 24V (12-24VAC/DC), 110VAC, 230VAC
Spare PCB c/w Xenon Tube
113/FH-PCB 12/24VAC/DC P.C.B c/w Xenon Tube
FHL113 113/FH-PCB 110V 110V P.C.B c/w Xenon Tube
113/FH-PCB 230V 230V P.C.B c/w Xenon Tube 113/FH-PCB 230V
Sounders Intrinsically safe zone 0, 1 & 2 Gas Group 11C
Operating Max Min Sound
Voltage Material Current at at Rated IP
Code
Range Rated Voltage Rating Tone
Voltage (A) (dB@1m)
E2SIS 24VDC ABS Flame retardant 25mA 100 IP65 49 Tone
E2SIS E5YIS UL94VO
E5YIS 24VDC ABS Flame retardant 93mA 105 IP66 32 Tone
UL94VO

Beacons
E2BIS-* 24VDC ABS Flame retardant 25mA – IP65 Beacon
UL94VO
*Add colour: ●R (Red), ●A (Amber), ●G (Green), ●B (Blue)
Sounder/Beacons
E25BIS-* 24VDC ABS Flame retardant 48mA 100 IP65 49 Tone
UL94VO
E2BIS E25BIS *Add colour: ●R (Red), ●A (Amber), ●G (Green), ●B (Blue)

23 FLP
LED EXPLOSION PROOF BEACONS IP65
Beacon / Sounder - ≥80dB Beacon

II 2G Exd [ib] ib II CT6 II 2G Exd II CT6

Code Colour Code Colour


BBJ-ZG-* ● Green BJD-ZG-* ● Green
BBJ-ZR-* ● Red BJD-ZR-* ● Red
BBJ-ZY-* ● Yellow BJD-ZY-* ● Yellow
BBJ-ZB-* ● Blue BJD-ZB-* ● Blue
*Add voltage to code: 110VAC, 230VAC
• LED lamp, low energy consumption, long service life • Ideally suited for use in IIA, IIB and IIC areas.
• IP-Rating IP65 • Glass cover resistant to temperature changes
• Flash frequency: 150/min • Housing in aluminium alloy, powder-coated
• Cable entry c/w cable seal-ring and locking device • Suitable for use in Zones 1 & 2

EXPLOSION PROOF ANALOGUE ULTRASONIC LEVEL DETECTION

For continuous no-contact level


measurement of various liquid
and bulk solid materials in
closed or open vessels, sumps,
reservoirs etc.
Sensing Distance
Output Type
0,2 - 2m 0,25 - 6m 0,4 - 10m 0,5 - 20m
Explosionproof Field Adjustable Type - Must be used with IRU-420 (Below) c/w Connector Socket
4 - 20mA (2-Wire) ULM-53XI-02-I ULM-53XI-06-I ULM-53XI-10-I ULM-53XI-20-I
EX Rating Suitable for explosive areas Suitable for explosive areas Suitable for explosive areas Suitable for explosive areas
(combustible gases or vapours) (combustible gases or vapours) (combustible gases or vapours) (combustible gases or vapours)
II 1/2G Ex ia IIB T5 with II 1/2G Ex ia IIB T5 with II 1/2G Ex ia IIA T5 with II 2G Ex ia IIA T5 with
isolating repeater (IRU–420) the isolating repeater (IRU–420) the isolating repeater (IRU–420) isolating repeater (IRU–420)
whole level meter – zone 1, front whole level meter – zone 1, front the whole level meter – zone 1, the whole level meter – zone 1
head part – zone 0 head part – zone 0 front head part – zone 0

Mounting Type G1" G1½" Polypropylene Aluminium Alloy Flange


Supply Voltage 18 - 36VDC
Accuracy 0.20%
Ambient Temperature -30° to 70°C -30° to 60°C
Dimensions ground Wiring Diagram
terminal
Al alloy
Ø18 x 18
20

Polypropylene
DN65
179

Ø14x4
150
14

122
131

55
94
115

102
86

43
55
39

32

Ø56 Ø106
18

Ø130 Ø180
Ø25 Ø38
G 1 1 2” Ø160 Ø220
G1”

Isolating Repeater - for use with ULM-53XI


Code IRU-420-I-* IRU-420-H-* IRU-420-U-*
Input Signal 0/4 - 20mA 4 - 20mA 4 - 20mA
Output Signal 0/4 - 20mA 4 - 20mA 4 - 20mA
Bi-directional Trans Comms NO YES NO
Signal HART
TM

*Add Voltage to Code: 24V (18-30VAC/18-40VDC) 230V (60-230VAC/85-230VDC)


II(1)G[EEx ia] IIB /IIC I(M1)G[EEx ia] I

FLP 24
COMMUNICATION EQUIPMENT
Robust Telephones Explosion Proof ABS Weatherproof IP54
Ex d I/II B + H2 T6/
Ex m e [ia]I/II C T6

I430-ICE I448
Zenith Ratel Phoenix Code I430-ICE
Size: 310 x 220 x 130.
Code Z500 A120 A130 Single Telephone Cable Pair, 2-80 telephone.
Rating IP65 Weatherproof Double Protection Line Voltage: 48VDC. Distance: 10-12km.
Max 80 phones per power supply.
Size (HxWxD) 260 x 120 x 100mm 230 x 140 x 110mm 280 x 15 x 140mm
Housing ABS M/Steel Powder Coated Gun Metal Brass Code I448
Weight 1Kg 2.5Kg 9Kg 110/230-48VDC
Automatic analogue industrial/mining telephone compatible with all 24V/48V Power supply to be ordered separately with
PABX systems, pulse/tone switchable. Ring signal 45V-90VAC 17Hz-50Hz 48hr battery back up included
Telephone Booths Telephone Extension Light/Siren
Phone Ringer. For standard 2 wire analogue phones only.
SSLU
Weatherproof IP65
340 x 140 x 120
ABS
3Kg
Acoustic Non Acoustic
Code ATB100 TB100 • Operates in sympathy with the
telephone ring signal.
Size (HxWxD) 670 x 500 x 450mm 670 x 450 x 500mm • Powered by 110 or 220VAC
Housing Fibreglass Polypropylene • Siren 116db o/p.
Weight 7.5Kg 5Kg • Light 8 x super bright LED. Light & Siren Unit

PAGE TELEPHONES
Page Telephones
Code P300 P300NHT
Handset No Yes
Rating Weatherproof IP65 Weatherproof IP65
Size (HxWxD) 310 x 140 x 120mm 310 x 140 x 120mm
Housing ABS ABS
Weight 3kg 3.5kg
• 2-50 telephones connect in parallel with twisted telephone cable pair
P300NHT • Operates on 230VAC/ 110VAC
• Central 12V PSU option available
P300 • Simplex, open voice comms at 2 watt output

EX HOWL CALL TELEPHONE BOOTHS


Ex Howl Telephones - without power supply.
Sound-powered telephone systems for use in rough conditions, including areas
with explosive atmospheres and fire-damp.
Code Description
5069 Howl-Call Telephone without snap-in plug
Application - If you want or need to telephone in areas where this is normally not possible, you need a sound-powered telephone
system. Operation without external power supply and complex equipment, sound-powered telephones are ideal for communications
whenever there is no power supply available, e.g. at blast furnaces, in tunnelling or mining, or offshore on oil rigs or high-sea steam-
ers, and provide a direct connection to the switchboard, base, bridge or colleagues on the surface or wherever. This surprisingly
easy, but effective method is already used widely to call for material, report faults or save lives.

25 FLP
NOTES

FLP 26
Head Office NATIONAL
P.O. Box 3812, Edenvale Sales Tel: 010 202 3400
1610, South Africa Technical Tel: 010 202 3500
26 Nguni Drive info@acdc.co.za Germiston Tel: 011 418 9600
Longmeadow Estate West Tel: 010 202 3300 Cape Town Tel: 021 510 0710
Edenvale, Gauteng Fax: 087 807 5441 Pinetown Tel: 031 700 4215
South Africa www.acdc.co.za Riverhorse Tel: 031 492 4800
Distributors and Franchises throughout Southern Africa

3rd Edition September 2014