GENERAL
The cable is gel-filled loose tubes, dry cable core type with aramid strength yarns, aluminum tape protection,
galvanized steel messenger wire as aerial support and has the HDPE UV resistant black outer jacket protection.
The cable is applicable for outdoor, installed on up to 100-m span for aerial networks.
REFERENCE STANDARDS
The offered fiber optic cables comply to ITU-T G.652 (Table D) recommendation and annexes. The offered cables are
also fully compliant to the relevant IEC specification, especially IEC 60793-2-50 B1.3, IEC 60794-3 and related TIA/
EIA standards.
CABLE STRUCTURE
Cable DIN code : A-DQ(ZN)(L)T2Y E9/125/245 0.35F2.0 + 0.20H18 LG
- Fiber type is standard single mode according to ITU-T G.652.D recommendation
- FRP/ GRP, non-metallic, anti buckling central strength element
- Gel-filled thermoplastic loose buffer tubes (PC and PBT) to protect optical fibers from chemical reaction
- Each six fibers are inserted into the gel-filled thermoplastic loose buffer tubes
- The loose tube and plastic filler/ s are SZ-stranded around FRP/ GRP central element
- Water ingression protection using water blocking swellable material
- Aramid yarns as peripheral strength element
- Ripcord to ease jacket opening
- Aluminum tape longitudinally applied over the stranded loose tubes as moisture barrier
- Galvanised steel messenger wire 7 x Ø 1.2 mm
- Black UV resistant polyethylene (HDPE) jacket on cable core, bridge and messenger wire.
CABLE MARKINGS
The cable is printed with white-coloured markings as below format :
[meter] CCS INDONESIA [year] KABEL OPTIK SM.D A-LT [total fiber qty]/[tube qty] T
CABLE PARAMETERS
Cable Diameter (nominal) 10.4 mm
Cable Height (nominal) 19.5 mm
Cable Weight (nominal) 175 kg/km
Operating Tensile Strength (Refer to IEC 60794-1-E1) 2900 N
Crush Strength (Refer to IEC 60794-1-E3) 2.5 kN/ 100 mm
Impact Strength (Refer to IEC 60794-1-E4) 12 Nm
Kink Strength (Refer to IEC 60794-1-E10) 10 x Cable Outside Diameter
Minimum Bending Radius 15 x Cable Outside Diameter
Water Ingression Resistance (Refer to IEC 60794-1-F5B) Passed with 1-m cable sample, 24 hours,
1-m water column height pressure
Operating & Storage Temperature -10 deg.C up to +70 deg.C
HDPE Cable
Web/ Bridge
HDPE Jacket
Water Blocking Black Colour
Tape (WBT) Aramid Yarn
Aluminum Tape Strength Member
FRP/ GRP
Swell Yarn Central Member
Loose Tube
Contains
Ripcord Optical Fibers