B31.

1 FLUID SERVICES

Applies to all fluids where steam vapor is generated at 15 psig or higher. Steam condensate (liquids) where water is
160 psig or temperatures exceed 250F.

B31.3 FLUID SERVICES

CATEGORY D FLUID SERVICE

 Fluid is not flammable, not toxic or otherwise harmful to human tissues. Harmful means exposure that can
harm skin, eyes or mucous membranes that irreversible damage may result unless immediate action is taken.
 Design Gauge pressure is below 150 psi (1,035 kPa)
 Design Temperature is between -20F to 366F (-29C to 186C)

An example of Category D fluid might be utility water in a plant or low pressure steam condensate.

CATEGORY M FLUID SERVICE


Category M service is a fluid where the potential for personnel exposure is considered to be significant and where a
single exposure to a very small amount can cause serious irreversible harm to people. This could be death,
respiratory failure, blindness, etc. Design for Category M Fluid service should also meet the requirements of Chapter
VIII of B31.3.

An example of Category M fluid could be Hydrogen Sulfide gas, high concentrations of HydroChloric Acid or high
pressure steam.

HIGH PRESSURE FLUID SERVICE


High Pressure Fluid Service is one the pressures are in excess of ANSI Class 2500. It is important to note that B31.3
notes that there are no specified pressure limitations for the application of the High Pressure Piping Rules. Design
for High Pressure Fluid service should also meet the requirements of Chapter IX of B31.3.

NORMAL FLUID SERVICE


Fluid service that is covered by 31.3 but not subject to the rules for Category D, Category M or High Pressure Fluid
definitions.
ASME B31.3-Fluid Service Categories
*****************************************************************
Fluid Service Categories
  Category D Service
  Category M Service
  High Pressure Service (K)
  Normal Fluid Services

------------------------------------------------------------------------------------------------------------
Category D Service
  Non Flammable, Non Toxic  & Not Damaging to Human Tissue
  Design Pressure does not exceed 1035 kPa(g).
  Design Temperature Range -29C to 186C.
  Example-Utilities Services

------------------------------------------------------------------------------------------------------------
Category M Service
  Toxic fluid
  Produce serious Irreversible harm to persons on breathing or bodily contact.(even when prompt
restorative measure are taken)
  Chapter VIII for piping design and construction.
  Example-Lethal Fluid (Poisonous)

---------------------------------------------------------------------------------------------------------------------
High Pressure (K) Service
  Pressure in excess of that allowed by ASME B 16.5 flange Class 2500 rating.
  Chapter IX for piping design and construction.
  Example-High Pressure Fluid

------------------------------------------------------------------------------------------------------------
Normal Fluid Service
  A fluid service that are not
  Category D
  Category M
  or High Pressure  (K) Fluid Service.
  Piping design according to first Seven chapters of code.
  Example-Process Fluid

------------------------------------------------------------------------------------------------------------

Severe Cyclic Conditions


  Displacement Stress Range “SE” exceeds “0.8 SA” Allowable Stress Range.
  And the equivalent number of cycles exceeds 7000.
  Or conditions which the designer determines will produce an equivalent effect.