You are on page 1of 2

CANSWITCH TERMINAL BLOCK

CAN transceiver interface to switches and controls

BENEFITS
n Reduced Wiring
Clean up crowded control panels. Up to 56 switches and 4
analog inputs can be combined into a single CAN cable.
n Flexible Configuration
Use your own preferred switches of virtually any type or
arrangement.
n Switch “friendly”
On-board power supply provides 32VDC excitation - reduces
oxidation and extends switch life.
n Analog/Proportional Inputs
APPLICATIONS

4 analog inputs provided to incorporate analog devices such as
potentiometers, sensors, or joysticks.
n Simplify wiring in busy control panels and dashboards n Wide Compatibility
n Reduce number of wires needed - great for long cable runs Factory programmable for a wide range of CAN-compatible
protocols and network addresses.

WIRING
Customer supplied potentiometer or joystick
10K OHM

V
COMMON
SWITCH

CAN Network
32V

4
GND
+5V

1
3
2

and power
connection
1

5
3
2

Customer supplied switches ORDERING INFORMATION


PART # DESCRIPTION
CANSWTB Terminal block for field wiring customer switches

Consult factory for available protocols.

PAGE 40 MIRATRON 866-417-5008 503-352-0654 www.miratron.com


WIRING
PIN CANBUS
1 GROUND - NEGATIVE
DEUTSCH
0462-201-16141 2 BATTERY + POSITIVE
DEUTSCH 6 1
DEUTSCH SOLID SOCKET 3 CAN HI
W6S DT06-6S -OR- 5 2
WEDGE PLUG 1062-16-0122 4 3 4 CAN LO
FORM SOCKET 5 CAN SHIELD
6 NO CONNECT

POINT MAP
Address: 11 or 29 bits factory set - consult factory for specific requirements
Data Rate: 250kbps; update 20 times per second

Address 0x96 (150 decimal)


Analog IN 4 (MSB)

Analog IN 3 (MSB)

Analog IN 2 (MSB)

Analog IN 1 (MSB)
Analog IN 4 (LSB)

Analog IN 3 (LSB)

Analog IN 2 (LSB)

Analog IN 1 (LSB)
HEARTBEAT
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
BYTE 7 BYTE 6 BYTE 5 BYTE 4 BYTE 3 BYTE 2 BYTE 1 BYTE 0

Address 0x97 (151 decimal)


7 HEARTBEAT
6 NOT USED
5 NOT USED
4 NOT USED
3 NOT USED
2 NOT USED
1 NOT USED
0 NOT USED
Switch 56
Switch 55
Switch 54
Switch 53
Switch 52
Switch 51
Switch 50
Switch 49
Switch 48
Switch 47
Switch 46
Switch 45
Switch 44
Switch 43
Switch 42
Switch 41
Switch 40
Switch 39
Switch 38
Switch 37
Switch 36
Switch 35
Switch 34
Switch 33
Switch 32
Switch 31
Switch 30
Switch 29
Switch 28
Switch 27
Switch 26
Switch 25
Switch 24
Switch 23
Switch 22
Switch 21
Switch 20
Switch 19
Switch 18
Switch 17
Switch 16
Switch 15
Switch 14
Switch 13
Switch 12
Switch 11
Switch 10
Switch 9
Switch 8
Switch 7
Switch 6
Switch 5
Switch 4
Switch 3
Switch 2
Switch 1
BYTE 7 BYTE 6 BYTE 5 BYTE 4 BYTE 3 BYTE 2 BYTE 1 BYTE 0

Byte 7 reserved, TBD


Heartbeat output changes state every update. Controller should be programmed to monitor this output for fault detection.

SPECIFICATIONS
General Power requirement 12-30vdc, 50mA nominal
Fuse Self-resetting
Inputs Digital Up to 56 dry contact inputs
32-volt switch excitation voltage provided
Analog 4 x 0.5v to 4.5vdc
Communication CAN Compatible with most popular controllers, consult factory
Dimensions/Mounting CANSWTB 6.5”l x 2.85”w x 1.85”h

Environmental Conformal coated, enclosure required for environmental sealing
Operating temperature -30ºC to 65ºC

PAGE 41 MIRATRON 866-417-5008 503-352-0654 www.miratron.com