The document reports the results of a babbitt compression test conducted according to DOD STD 2183 specifications. A single rod of babbitt was tested at a speed of 0.5mm/min, with a maximum force of 2768.12N calculated over the entire test area.
The document reports the results of a babbitt compression test conducted according to DOD STD 2183 specifications. A single rod of babbitt was tested at a speed of 0.5mm/min, with a maximum force of 2768.12N calculated over the entire test area.
The document reports the results of a babbitt compression test conducted according to DOD STD 2183 specifications. A single rod of babbitt was tested at a speed of 0.5mm/min, with a maximum force of 2768.12N calculated over the entire test area.
DOD STD 2183 hole babbitt DOD STD Test File Name Method File Name 4.xtak 2183.xmak Report Date 08/02/2023 Test Date 08/02/2023 Test Mode Single Test Type Compression Speed 0,5mm/min Shape Rod No of Batches: 1 Qty/Batch: 1
Name Max_Force Calc. at Entire Parameters Areas Unit N 1_1 2768,12
S.No. Product / Material of Test Specific Test Performed Test Method Specification Against Which Tests Are Performed Range of Testing / Limits of Detection