You are on page 1of 2

39232 IB Date: 17.05.

23
1 E4A Speed difference between DDU & SPM.
2 E5A TFP-1 & 2 breather silica gel colour changed.
3 E5A TFP silica gel discoloured.
4 E8 Speed difference between DDU & SPM.
5 E8 F0702P1 & F0201P1 faults are experienced 23.04.23.
6 M1INSP Cab-2 LP side & Cab-1 LP & ALP side sander not working.
7 M1INSP Wheel no-10 earthing cable broken condition.
8 E4B U-1 meter "0" error.
9 E5B2 Machine room-1 middle tube light not glowing.
10 FAB Loco number not stencilled in both side of loco.
11 FAB Cab-2 LP side look out glass screen lock system defective.
12 M2 SS-2 not blowing 11 kg/cm2.
13 M2 Cab-2 FP showing 6.3 kg/cm2.
14 M2 Cab-1 SA-9 applu BC 3.0 kg/cm2.
37436 IB
1 E4A OCR 78 not sealed.
2 E4A AFL malfuctioning.
3 E4A 01 KMPH speed difference between DDU & SPM.
While changing cab some unusual sound from roof top found some burn mark on
4 E4B PT-1 & roof top 11.05.23.
5 E5B1 Cab-2 AC not working.
6 E8 01 KMPH speed difference between DDU & SPM.
7 E8 TM-4 temperature less showing (TM-4 isolated) 25.02.23.
8 M1INSP Cab-1 CBC operating handle not available.
Some times while applying direct brake Bogie-1 brakes are not applied & BC
9 M1INSP pressure also "0".
10 M1INSP cab-1 CBC operating handle broken due to CRO.
11 M1INSP Bogie-1 brake cylinder late application 05.05.23.
12 M2 Cab-2 AFI gauge light not glowing.
13 M2 Cab-2 ALP wiper not wiping properly.
While changing cab some unusual sound from roof top found some burn mark on
14 M2 PT-1 & roof top 11.05.23.
15 M2 AFL malfuctioning.
Some times while applying direct brake Bogie-1 brakes are not applied & BC
16 M2 pressure also "0".
17 M2 BP hose pipe broken due to CRO.
18 M2 Bogie-1 brake cylinder late application 05.05.23.
27651 IC
1 E4A LSFI glowing continuously.

2 E4A SIV restart automatically DJ trips via QVSI-1, HVSI-1 in 3 rd position dt 03.04.23.
3 E4B 100 V difference between U-5 & U-6.
4 E4B LSGR glowing with leakage current.

5 E8 SIV restart automatically DJ trips via QVSI-1, HVSI-1 in 3 rd position dt 03.04.23.


28020 IA
Every time after DJ closing DJ trip due to VCB defective fault message occuring
1 E4A 29.04.23.
After passing neutral section DJ tripped due to VCB defective message comes on
2 E4A closing DJ 20.04.23.
3 E4A VCD acknowledged only by PVEF not by PVCD 06.05.23.
4 E4A VCD not acknowledged by ACK push button 08.05.23.
5 E4B VCD Acknowledge only by PVEF not by PVCD 06.05.23.
Every time after DJ closing DJ trip due to VCB defective fault message occuring
6 E4B 29.04.23.
After passing neutral section DJ tripped due to VCB defective message comes on
7 E4B closing DJ 20.04.23.

You might also like