ACI 318-14 COLUMN SECTION DESIGN Type: Sway Special Units: N, mm, C (Summary)

Element : 75 B=130.000 D=400.000 dc=36.000


Section ID : K1 E=24855.578 fc=21.000 Lt.Wt. Fac.=1.000
Combo ID : COMB2 L=4500.000 fy=320.000 fys=320.000
Station Loc : 4500.000 RLLF=1.000

Phi(Compression-Spiral): 0.750
Phi(Compression-Tied): 0.650
Phi(Tension Controlled): 0.900
Phi(Shear): 0.750
Phi(Seismic Shear): 0.600
Phi(Joint Shear): 0.850

AXIAL FORCE & BIAXIAL MOMENT CHECK FOR PU, M2, M3


Capacity Design Design Design Minimum Minimum
Ratio Pu M2 M3 M2 M3
1.587 152928.532 25685524.64 -11986416.2 2927052.106 4165773.217

AXIAL FORCE & BIAXIAL MOMENT FACTORS


Cm Delta_ns Delta_s K L
Factor Factor Factor Factor Length
Major Bending(M3) 0.400 1.000 1.000 1.000 4500.000
Minor Bending(M2) 0.520 8.775 1.000 1.000 4500.000

SHEAR DESIGN FOR V2,V3


Rebar Shear Shear Shear Shear
Av/s Vu phi*Vc phi*Vs Vp
Major Shear(V2) 0.000 4304.685 32769.041 0.000 0.000
Minor Shear(V3) 0.000 688.910 26037.953 0.000 0.000

JOINT SHEAR DESIGN


Joint Shear Shear Shear Shear Joint
Ratio VuTop VuTot phi*Vc Area
Major Shear(V2) N/A N/A N/A N/A N/A
Minor Shear(V3) N/A N/A N/A N/A N/A

(6/5) BEAM/COLUMN CAPACITY RATIOS


Major Minor
Ratio Ratio
N/A N/A

Notes:
N/A: Not Applicable
N/C: Not Calculated
N/N: Not Needed

D:\2. JOB\REVISI perubahan denah goa gong\sap bayu\83819_ISI.pdf.sdb 6/26/2016 7:43 AM