Page 1 of 5

Epicentrum Walk Office Boulevard Suite


MATERIAL SAFETY DATA SHEET JL.HR Rasuna Said, 5th Floor A529
Jakarta Selatan 12940
Emergency Call : +62 21 5682703

ScaleChemTM SI-7022
Date Effective 04/11/2019
Oil Field Scale Inhibitor

SECTION I: PRODUCT IDENTIFICATION

Company Name : PT. PANJI LABORTA CHEMINDO


Emergency Telephone No : +62 21 56882703
Address : Epicentrum Walk Office Boulevard Suite
JL.HR Rasuna Said, 5th Floor A529
Jakarta Selatan 12940
INDONESIA
Trade Name ScaleChemTM SI-7022
Chemical Family Scale Inhibitor For Oil Field
Chemical Formula Phosponate Based
CAS Number Proprietary Blend

SECTION II: COMPOSITION INFORMATION ON HAZARDOUS INGREDIENTS

CAS Number Component Common Name TWA STEL PEL Weight Percent
34890-00-1 Phosponate Base NE NE NE > 40%
10124-56-8 Sodium Hexametaphospate NE NE NE 5-20%
1310-73-2 Caustic soda NE NE NE 1-10%
7732-18-5 Water NE NE NE >20%

Schedule B, Harmonized Tariff Number for Import/Export


3402903000 Surface-active preparations, contain surface active agents

SECTION III: HAZARDS IDENTIFICATION

Routes of Entry Skin contact, eye contact, inhalation, ingestion.


Potential Health Effects This product may cause eye, skin, or respiratory irritation.
Carcinogenicity (NTP) This product is not believed to be carcinogenic.
Carcinogenicity (IARC) This product is not believed to be carcinogenic.
Carcinogenicity (OSHA) This product is not believed to be carcinogenic.

SECTION IV: FIRST AID MEASURES

Eyes Flush eyes with plenty of water at least 15 minutes. Get medical
attention immediately.
Skin Flush exposed area with soap and water. In case of persistent skin
irritation, get medical attention immediately. Wash clothing before
reuse .
Ingestion Do not induce vomiting. Rinse mouth with water. If conscious,
give 1-2 glasses of water. Get medical attention immediately.
Do not give anything to unconscious persons.
Inhalation Remove to fresh air. Remove contaminated clothing. If breathing has
stopped, apply artificial respiration. If breathing is difficult , give oxygen.
Get medical attention immediately.

Disclaimer For further information, please contact the manufacturer listed above. This information and recommendations contained herein are based upon data believed to be correct.
However, no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein. This Material Safety Data Sheet was
prepared to
comply with OSHA Hazardous Communication Standard (29 CFR 1910.1200) and the Workplace Hazardous Materials Information System (WHIMS).

Untuk informasi lebih lanjut, silahkan hubungi produsen yang tercantum di atas. Informasi ini dan rekomendasi terkandung didasarkan pada data yang diyakini benar.
Namun, tidak ada jaminan atau jaminan apapun tersurat maupun tersirat dibuat sehubungan dengan informasi yang tercantum di sini. Lembar Data Keselamatan
Bahan ini siap untuk mematuhi Standar OSHA Berbahaya Komunikasi (29 CFR 1910.1200) dan Tempat Kerja Sistem Informasi Bahan Berbahaya (WHIMS).
Page 2 of 5
Epicentrum Walk Office Boulevard Suite
MATERIAL SAFETY DATA SHEET JL.HR Rasuna Said, 5th Floor A529
Jakarta Selatan 12940
Emergency Call : +62 21 5682703

ScaleChemTM SI-7022
Date Effective 04/11/2019
Oil Field Scale Inhibitor

SECTION V: FIRE FIGHTING MEASURES

Flammable Limits, Flash Point No Flammability


Flammable Limits in Air – LEL ND
Flammable Limits in Air – UEL ND
Auto Ignition Temperature ND
General Hazards None known.
Extinguishing Media Foam, dry chemical, carbon dioxide, and water spray to cool
containers.
Fire Fighting Equipment Wear self-contained breathing apparatus and protective clothing.
Fire and Explosion Hazards Containers may explode from internal pressure if confined to fire.
Hazardous Combustion Products Not available.
Sensitivity to Mechanical Impact Not expected
Sensitivity to Static Discharge Not expected.
Additional Information No additional information available

SECTION VI: ACCIDENTAL RELEASE MEASURES

Accidental Release Measures Provide good ventilation. Avoid breathing vapors and contact with skin
and eyes Wear appropriate personal protection (as directed in Section
VIII). Contain and absorb spill with sand, earth, inert material or
vermiculate, wipe up and place in a suitable labeled container for
waste disposal. Avoid run off into sewers, ditches and water course.

SECTION VII: HANDLING AND STORAGE

Handling and Storage Guidelines Avoid contact with skin, eyes and clothing. Do not ingest or inhale.
Use only in adequate ventilation. Wash thoroughly after handling.
Remove contaminated clothing and shoes, and wash before reuse.
Keep away from, heat, ignition and incompatibles. Keep in a tightly
closed container stored in a dry, cool, well ventilated area, away from
incompatible materials, heat and open flame
SECTION VIII: EXPOSURE CONTROL/PERSONAL PROTECTION

Personal Protective Equipment Wear appropriate equipment to prevent probability of exposure.


Eye Protection Goggles or glasses with side shields.
Skin Protection Wear impervious gloves as a standard handling procedure.
Respiratory Protection Use NIOSH approved respiratory protection where exposure
levels exceed regulatory limits
Engineering Controls Do not aerosolize.
Mechanical Exhaust Required in confined spaces.
Local Exhaust Recommended to keep fumes from concentrating.
Emergency Response Protection No additional specialized equipment should be required

Disclaimer For further information, please contact the manufacturer listed above. This information and recommendations contained herein are based upon data believed to be correct.
However, no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein. This Material Safety Data Sheet was
prepared to
comply with OSHA Hazardous Communication Standard (29 CFR 1910.1200) and the Workplace Hazardous Materials Information System (WHIMS).

Untuk informasi lebih lanjut, silahkan hubungi produsen yang tercantum di atas. Informasi ini dan rekomendasi terkandung didasarkan pada data yang diyakini benar.
Namun, tidak ada jaminan atau jaminan apapun tersurat maupun tersirat dibuat sehubungan dengan informasi yang tercantum di sini. Lembar Data Keselamatan
Bahan ini siap untuk mematuhi Standar OSHA Berbahaya Komunikasi (29 CFR 1910.1200) dan Tempat Kerja Sistem Informasi Bahan Berbahaya (WHIMS).
Page 3 of 5
Epicentrum Walk Office Boulevard Suite
MATERIAL SAFETY DATA SHEET JL.HR Rasuna Said, 5th Floor A529
Jakarta Selatan 12940
Emergency Call : +62 21 5682703

ScaleChemTM SI-7022
Date Effective 04/11/2019
Oil Field Scale Inhibitor

SECTION IX: PHYSICAL AND CHEMICAL PROPERTIES

Appearance and odor Brown liquid, pungent


Specific Gravity 0.956 – 1.156
Density, lbs/gal 7.98 – 9.65
Boiling Point/Range ° 213 – 218
Viscosity, Cst (30 oC) 1.00 – 3.5
pH 2.0 – 3.0
Residue 0 - 10 %
Solubility Soluble in water
Color (ASTM D 1500-64) 4.5 – 5.5

SECTION X: STABILITY AND REACTIVITY

Stability Stable at normal temperatures and operating conditions.


Incompatibilities Alkalis, oxidizing agent
Decomposition Phosphine (highly flammable and toxic)
Polymerization Polymerization will not occur

SECTION XI: TOXICOLOGICAL INFORMATION

Eye Irritation Eye contact may be painful and irritating.


Skin Irritation Prolonged and repeated skin exposure may be painful and irritating.
Inhalation Toxicity Inhalation of this product during manufacturing may be irritating.
Sensitization Not evaluated.
Chronic/Carcinogenicity Not evaluated.
Reproduction Not evaluated.
Mutagenicity Not evaluated.
Acute Oral Effects Not evaluated.
Acute Dermal Toxicity Not evaluated.
` Additional Information Not evaluated.

SECTION XII: ECOLOGICAL INFORMATION

Ecotoxicity Not evaluated.


Biological Oxygen Demand (BOD5) Not evaluated.
Chemical Oxygen Demand Not evaluated.
Activated Sludge Respiration Inhibition Test Not evaluated.
Additional Information Expected to readily biodegrade, is expected to leach into groundwater
and is not expected to evaporate significantly. This material has a log
octanol-water partition coefficient of less than 3.0. This material is not
expected to significantly bioaccumulate. When released into the air,
this material is expected to be readily degraded by reaction with
photochemically produced hydroxyl radicals, and this material is
expected to have a half-life of less than 1 day.

Disclaimer For further information, please contact the manufacturer listed above. This information and recommendations contained herein are based upon data believed to be correct.
However, no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein. This Material Safety Data Sheet was
prepared to
comply with OSHA Hazardous Communication Standard (29 CFR 1910.1200) and the Workplace Hazardous Materials Information System (WHIMS).

Untuk informasi lebih lanjut, silahkan hubungi produsen yang tercantum di atas. Informasi ini dan rekomendasi terkandung didasarkan pada data yang diyakini benar.
Namun, tidak ada jaminan atau jaminan apapun tersurat maupun tersirat dibuat sehubungan dengan informasi yang tercantum di sini. Lembar Data Keselamatan
Bahan ini siap untuk mematuhi Standar OSHA Berbahaya Komunikasi (29 CFR 1910.1200) dan Tempat Kerja Sistem Informasi Bahan Berbahaya (WHIMS).
Page 4 of 5
Epicentrum Walk Office Boulevard Suite
MATERIAL SAFETY DATA SHEET JL.HR Rasuna Said, 5th Floor A529
Jakarta Selatan 12940
Emergency Call : +62 21 5682703

ScaleChemTM SI-7022
Date Effective 04/11/2019
Oil Field Scale Inhibitor

SECTION XIII: DISPOSAL CONSIDERATIONS

Container Disposal Management Dispose of in accordance with local, state, and federal regulations.
RCRA Hazard Class No Ignition
Waste Disposal Method Dispose of in accordance with local, state, and federal regulations.

SECTION XIV: TRANSPORT INFORMATION

DOT Hazard Class Liquid Acid


DOT Proper Shipping Name DOT. 08
Packaging Group PG II
UN Number UN 1993
NA Number NA
Packaging Size Plastic Drums / IBC Plastic

SECTION XV: REGULATORY INFORMATION

SARA 302/304 RQ NA
SARA 302/304 TPQ NA
SARA 311/312 Acute Yes
SARA 311/312 Chronic Yes
SARA 311/312 Fire Yes
SARA 311/312 Pressure NA
SARA 311/312 Reactivity NA
SARA 313 List NA
CERCLA RQ Yes
TSCA Status All components are registered on TSCA inventory.
CAA Section 111 & 112
CWA Section 304, 307, 311, & Safe Drinking Water Act
SARA 311/312 Acute Yes
SARA 311/312 Chronic Yes

Disclaimer For further information, please contact the manufacturer listed above. This information and recommendations contained herein are based upon data believed to be correct.
However, no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein. This Material Safety Data Sheet was
prepared to
comply with OSHA Hazardous Communication Standard (29 CFR 1910.1200) and the Workplace Hazardous Materials Information System (WHIMS).

Untuk informasi lebih lanjut, silahkan hubungi produsen yang tercantum di atas. Informasi ini dan rekomendasi terkandung didasarkan pada data yang diyakini benar.
Namun, tidak ada jaminan atau jaminan apapun tersurat maupun tersirat dibuat sehubungan dengan informasi yang tercantum di sini. Lembar Data Keselamatan
Bahan ini siap untuk mematuhi Standar OSHA Berbahaya Komunikasi (29 CFR 1910.1200) dan Tempat Kerja Sistem Informasi Bahan Berbahaya (WHIMS).
Page 5 of 5
Epicentrum Walk Office Boulevard Suite
MATERIAL SAFETY DATA SHEET JL.HR Rasuna Said, 5th Floor A529
Jakarta Selatan 12940
Emergency Call : +62 21 5682703

ScaleChemTM SI-7022
Date Effective 04/11/2019
Oil Field Scale Inhibitor

SECTION XVI: OTHER INFORMATION

HMIS Hazard Classification Health Flammability Reactivity Personal Protection


0 0 1 G
NFPA Hazard Classification Health Flammability Reactivity Personal Protection
Classification Code or Markings 0 0 1

Explanation of NFPA Special Symbol

Oxidizer; a chemical that can increase the rate of combustion or fire

Reactive with water; avoid using water when fighting a fire involving material

Corrosive material(s); can be corrosive in either an acid or alkaline state

Poison or highly toxic material(s)

Explosive material(s); redundant notation of instability

Corrosive material(s); can be corrosive in either an acid or alkaline state

Disclaimer For further information, please contact the manufacturer listed above. This information and recommendations contained herein are based upon data believed to be correct.
However, no guarantee or warranty of any kind expressed or implied is made with respect to the information contained herein. This Material Safety Data Sheet was
prepared to
comply with OSHA Hazardous Communication Standard (29 CFR 1910.1200) and the Workplace Hazardous Materials Information System (WHIMS).

Untuk informasi lebih lanjut, silahkan hubungi produsen yang tercantum di atas. Informasi ini dan rekomendasi terkandung didasarkan pada data yang diyakini benar.
Namun, tidak ada jaminan atau jaminan apapun tersurat maupun tersirat dibuat sehubungan dengan informasi yang tercantum di sini. Lembar Data Keselamatan
Bahan ini siap untuk mematuhi Standar OSHA Berbahaya Komunikasi (29 CFR 1910.1200) dan Tempat Kerja Sistem Informasi Bahan Berbahaya (WHIMS).