PENTENS T-201 Product Data Sheet

Acrylic Waterproofing Emulsion

Description Technical & Physical Data


PENTENS T-201, is a high quality one- Form Liquid
component elastomeric waterproofing coating, in Grey, white, green,
Color
an acrylic emulsion base, intended for the yellow, etc.
protection and decoration of above ground Resin Acrylic
concrete and masonry surfaces. It is also Density 1.20  0.1 kg/litre
finishing for all types of roofs and facades. Solid content >60% by weight
Elongation (ASTM
>200%
Uses D412)
Tensile Strength
 PENTENS T-201 is formulated to be applied >13 kgf/cm2
(ASTM D412)
as a waterproof and decorative coating on all Tear Strength
horizontal and slopped concrete roofs, >10 kgf/cm
(ASTM D624)
asbestos-cement surfaces, metals, bricks,
wood, and defective asphalt. Aging Test (800C、
 PENTENS T-201 also can be used as a 168hrs) ASTM D573-04
>20 kgf/cm2
coating for building facades and several a. Tensile Strength
>190 %
types of concrete, concrete block, brick and b. Elongation
> 18 kgf/cm
stucco structures and retaining walls. c. Tear Strength
Water Vapor Transmission <4
(Perms)
Advantages ASTM E96 Method B
 Completely waterproof
Application Temperature 5oC to 40oC
 Excellent elastic regain
Service Temperature 0oC to 80oC
 Flexible at low temperatures
At least 1 year when
 Superb adhesion to all sound roofing
Self Life unopened and
surfaces
damaged
 Outstanding exterior durability UV light,
infra-red and ozone resistance Store in a dry cool
Storage condition
 High resistance to dirt pickup hence long place
term reflectivity and lower air-conditioning 20kg pail
Packaging
costs 200kg drum
 Low toxicity and odor
 Low moisture-vapor transmission Important Notes
 Excellent film integrity 1. Minimum ambient and substrate temperature
 Easy application is 5oC.
 Easy cleaning 2. Apply only to clean, sound substrates where
 Pedestrian properties of the roofing surfaces should be well dampened but free of
membrane surface water and leaks.
3. Thoroughly agitate contents before use.

Disclaimer. All representations and recommendations set forth are given in good faith and to the best of our knowledge. Howev er due to
varying conditions and applications, the buyer shall conduct its own tests of this product before use. Under no circumstances will the
manufacturer be liable for any loss or damages caused by incorrect usages. The sale of this product shall be on terms and con ditions set
forth on Pentens order acknowledgement.
Product Data Sheet

Instruction for Use For more details, please refer to our Technical
Department.
Surface Preparation
Ensure that the surface to be treated is free from Curing
any loose particles, dust, oil, dirt, extra cement Allow the coating to cure thoroughly before
blocks and especially sand. applying the next coat. Depending on
Clean a second time, using a soft broom or a temperature, humidity and wing conditions,
vacuum cleaner, to make sure that the surfaces normally 1~8 hours should be taken between
are absolutely dust free. two coats.
Priming Note
Apply one coat of diluted PENTENS T-007 (1 The best method to assure good penetration of
portion of T-007 with 3 portions of water) by the first coat into the surface is by application
roller, brush or spray gun. with a nap roller. The succeeding coats may be
When applying on a defective bitumen layer use spray or roller applied.
0.1kg/m2.
For concrete surfaces use 0.2~0.3 per m2. Cleaning
Note: It is advised for a heavy duty and long Tools and equipment just can be clean with
lasting application to lay special fiber PENTENS clean water immediately, after use. Hardener
W-015 on the surface to be treated. This fiber material can only be mechanically removed.
can be applied on the pre-existing cracks only.

Application
Safety
PENTENS T-201 is non-toxic. For personal
On areas exposed hot drying winds. 2 to 3 thin
precautions, applicators are recommended to
coats of paint may be more successful than 1
wear gloves and goggles when handling
thick coat.
PENTENS T-201. Treat any splashes to the skin
or eyes with fresh water immediately. Should
PENTENS T-201 is suggested to apply at least 2
any of the products be accidentally swallowed,
coats. The first coat should be applied in one
do not induce vomiting, call for medical
direction only. If possible the second coat should
assistance immediately.
be applied at right angles to the first. Leave to
cure for approximately 8 hours before applying
second coat. PENTENS T-201 can be installed
with conventional airless spray equipment, brush
or roller.

In case of using PENTENS W-015 fiber layer,


paint T-201 in one direction to avoid bubbling of
the fiber.

Consumption
On concrete roofs: 1kg/m2/per coat
On facade/vertical: 0.5~1kg/m2/per coat
2
 1.3kg/m per coat when PENTENS W-015
Glass Fiber Mesh is used.
2
 1.0kg/m per coat when PENTENS W-015
Glass Fiber Mesh is not used.

UFON NANO-CHEMICAL CORP.


PENTENS No.36, Lane 105, Chengfu Rd., Sansia Dist., New Taipei City 23743, Taiwan
Tel: +886 2 26682003 Fax: +886 2 26681546
URL: www.pentens.com E-mail: service@pentens.com
T-201
Acrylic Waterproofing Emulsion
Pentens T-201, is a high quality one component elastomeric waterproofing
coating, in an acrylic emulsion base, intended for the protection and
decoration of above ground concrete and masonry surfaces. It is also
finishing for all types of roofs and facades.

Pentens T-201 is formulated to be applied as a waterproof and decorative


coating on all horizontal and slopped concrete roofs, asbestos-cement
surfaces, metals, bricks, wood, and defective asphalt.

Pentens T-201 also can be used as a coating for building facades and several
types of concrete, concrete block, brick and stucco structures and retaining
walls.

Good Elastic
Elongation > 200 %

Crack Seal
Excellent Bonding

ADVANTAGES:
- Completely waterproof
- Excellent elastic regain
- Flexible at low temperatures
- Superb adhesion to all sound roofing surfaces
- Outstanding exterior durability UV light, infra-red and
ozone resistance
- High resistance to dirt pickup hence long term reflectivity
and lower air-conditioning costs
- Low toxicity and odor
- Low moisture-vapor transmission
- Excellent film integrity
- Easy application
- Easy cleaning
- Pedestrian properties of the roofing membrane

8
SURFACE PREPARATION TECHNICAL & PHYSICAL DATA
Ensure that the surface to be treated is free from any loose particles,
dust, oil, dirt, extra cement blocks and especially sand. Clean a Form Liquid
second time, using a soft broom or a vacuum cleaner, to make sure Color Grey, white, green
that the surfaces are absolutely dust free.
Resin Acrylic
PRIMING Density 1.20 ± 0.1 kg/litre
Apply one coat of diluted Pentens T-007 (1 portion of T-007 with 3
portions of water) by roller, brush or spray gun. Solid content > 60% by weight

Elongation > 200%


When applying on a defective bitumen layer use 0.1kg/m2. (ASTM D412)
For concrete surfaces use 0.2 0.3 kg per m2.
Tensile Strength >13 kgf/cm2
Note: It is advised for a heavy duty and long lasting (ASTM D412)
application to lay special fiber Pentens W-015 on the surface Tear Strength >10 kgf/cm
to be treated. This fiber can be applied on the (ASTM D624)
pre-existing cracks only.
Aging Test (800C、168hrs)
ASTM D573-04
APPLICATION
a. Tensile Strength >20 kgf/cm2
On areas exposed hot drying winds. 2 to 3 thin coats of paint may be b. Elongation >190 %
more successful than 1 thick coat. c. Tear Strength > 18 kgf/cm

Water Vapor Transmission (Perms) <4


Pentens T-201 is suggested to apply at least 2 coats. The first coat
ASTM E96 Method B
should be applied in one direction only. If possible the second
coat should be applied at right angles to the first. Leave to cure for Application Temperature 5o C to 40o C
approximately 8 hours before applying second coat. Pentens T-201
Service Temperature 0o C to 80o C
can be installed with conventional airless spray equipment brush or
roller. Self Life At least 1 year when
unopened and
In case of using Pentens W-015 fiber layer, paint Pentens T-201 in damaged
one direction to avoid bubbling of the fiber. Storage condition Store in a dry cool
place
COVERAGE
On concrete roofs: 1kg/m2 Packaging 20kg pail
On facade/vertical: 0.5 1kg/m2
IMPORTANT NOTES
1.3kg/m2 per coat when Pentens W-015 Glass Fiber Mesh is used.
1. Thoroughly agitate contents before use.
2. Minimum ambient and substrate temperature is 5oC.
For more details, please refer to our Technical Department.
3. Apply only to clean, sound substrates where surfaces should be well
dampened but free of surface water and leaks.
CURING
Allow the coating to cure thoroughly before applying the next coat.
Depending on temperature, humidity and wing conditions, normally
1 8 hours should be taken between two coats.

NOTE
The best method to assure good penetration of the first coat into the
surface is by application with a nap roller. The succeeding coats may
be spray or roller applied.

CLEANING
Tools and equipment just can be clean with clean water immediately,
after use. Hardener material can only be mechanically removed.

SAFETY
Pentens T-201 is non-toxic. For personal precautions, applicators
are recommended to wear gloves and goggles when handling
Pentens T-201. Treat any splashes to the skin or eyes with fresh water
immediately. Should any of the products be accidentally swallowed,
do not induce vomiting, call for medical assistance immediately.