One platform
– countless possibilities
• Lower your costs with reduced
stock levels
• Decrease your total lifetime
investment
• Future-proof your heat and cooling
installation with full flexibility
MULTICAL® 303, 403, 603 and 803

Next-level flexibility
Quality, flexibility and scalability are key to ensuring that the metering
solution you choose today also provides you with the right tools for the
demands of the future.

Third generation platform


Kamstrup has developed a complete meter platform that gives you the
ultimate flexibility. Our shared MULTICAL® platform for 303, 403, 603
and 803 heat, cooling and combined heat/cooling meters allows you to
easily upgrade rather than replace your meters as new possibilities and
challenges occur. These upgrades can be done without interfering with
legal registers and with no or minimal impact on meter readings and
network management.

Geared for the future


The modularity of the MULTICAL® 403, 603 and 803 platform means
that you are able to seamlessly add or switch communication
modules to match your communication demands. The built-in two-
way communication allows software download to either meter or
communication module as well as remote configuration of meter and
module. Furthermore, it is possible to read out the data logger without
direct access to the installation.

In this way, you can effectively future-proof across your Kamstrup


solution.

Heat Cooling

Built to last – designed to perform


The third generation of Kamstrup’s MULTICAL®
heat and cooling meters is based on a deep
understanding of the challenges faced
by utilities. Combined with decades of
experience developing innovative ultrasonic
technology and future-proof design, the
result is high-quality meters with simple-
to-use functionality, unrivalled accuracy and
reliability.

2
MULTICAL® 303, 403, 603 and 803

Better operation Lower costs and


optimisation higher ROI
MULTICAL® 303, 403, 603 and 803 offer full support for The new and updated Kamstrup ultrasonic flow sensors
remote reading for billing and give you instant access for MULTICAL® 303, 403, 603 and 803 have an increased
to the information needed to analyse and optimise dynamic range compared to their predecessors, but
your distribution network. The data loggers are fully despite this, they have a low pressure loss, which means
programmable to save yearly, monthly, daily, hourly and less pumping capacity is required. This reduces the
minute values. This lets you effectively analyse and consumption of the circulation pumps and limits the
diagnose your application for faster identification of load energy loss in the installation – all of which lowers the total
profiles, errors and inconsistencies. lifetime cost of the meters and ensures a larger return on
investment.
MULTICAL® 403, 603 and 803 can be equipped with a wide
range of advanced communication modules, e.g. M-Bus MULTICAL® 403, 603 and 803 can be powered with mains
and Wireless M-Bus. The improved M-Bus allows fast and or battery supply depending on your needs. No matter what
frequent data readouts without reducing the meter’s solution you choose, the own consumption of the meters is
battery lifetime. extremely low. This lowers your operational costs as well as
the total lifetime cost of each meter.

010110
010110
010110
010110
010110
010110
010110
010110
010110
010110
010110
010110

Mixed fluid
COP for heat compatible Fully
pumps and gas programmable
boilers data logger
Software 7 or 8 digit
download display
(MID approved) resolution
Thermal
3 tariff disconnect
registers
i
ii
system
Temperature
off-set Info code
adjustment logger

Backup of real
Third generation
time clock
(RTC)
heat and cooling meters Pulse
in-/outputs

Though different, our third generation heat and cooling meters share
many of the same functionalities. This means that you reap the
same benefits regardless of which meter is the right choice for you.

Low stockholding and easy installation


MULTICAL® 303, 403, 603 and 803 are suited for many different applications and settings including energy unit and inlet/
outlet position of the flow sensor, and much more can be individually configured on-site using the front keys. This allows you
to keep a low stock, be more cost-effective and save resources previously spent on planning.

One screwdriver is all you need for mounting a third generation MULTICAL® meter. The design and high quality of the meter
means that it is virtually maintenance-free while reconfiguration or service is easily completed due to the simple setup.
Therefore, the time and cost spent on installations and maintenance are lower than ever before.
3
MULTICAL® 303, 403, 603 and 803

Choose the right meter


MULTICAL® 303 MULTICAL® 403 MULTICAL® 603 MULTICAL® 803
This overview will help you pick the
meter that matches your needs and
requirements.

Heat meter approval (MID, EN1434) DK-0200-MI004-045 DK-0200-MI004-037 DK-0200-MI004-040 DK-0200-MI004-042


Cooling meter approval (BEK-1178, EN1434) TS 27.02 015 TS 27.02 009 TS 27.02 012 TS 27.02 013
Temperature range 2…180 °C
Differential temperature 3…178 K
Medium temperature 2…130 °C
Mains supplied 24 VAC/VDC or 230 VAC
Battery supplied 1 x A-cell/2 x A-cell 1 x C-cell/1 x D-cell/ 1 x D-cell/2 x A-cell 2 x A-cell
2 x A-cell
Battery lifetime 1) Up to 16 years Up to 6 years 2)
Flow range qp 0.6…2.5 m³/h qp 0.6…15 m³/h qp 0.6…1000 m³/h 3)
Flow sensor cable length 1.5 m 2.5…100 m 4)
Temperature sensor 2-wire, 2-wire, 2- or 4-wire, 4-wire,
Pt500 Pt500 Pt500 or Pt100 Pt500/100 auto
Temperature sensor cable length 1.5…3 m 1.5…10 m 1.5…100 m
Protection class Calculator IP65 Calculator IP54 Calculator IP65

58115007_G1_EN_09.2022
Flow sensor IP68 Flow sensor IP68 ULTRAFLOW® IP65/IP67
Integration mode 4…64 s 2…64 s 2 s (8 s)
Measuring unit MWh – kWh – GJ MWh – kWh – GJ – Gcal
Module slots 1 2 4
Integrated M-Bus ü ü
Integrated Wireless M-Bus ü
Data and analog modules ü ü ü
M-Bus and Wireless M-Bus modules ü ü ü
Industrial modules (ModBus, BACnet) ü ü ü
Separable calculator and flow sensors ü ü
Connection of third-party flow sensors 5) ü ü
Backlit display ü (option) ü
Mixed fluid compatible ü (option) ü (option)
1) Battery lifetime depends on various factors, e.g. integration mode, readout interval.
2) Backup battery for the operation of the basic meter functionality or basic meter functionality and communication on module slot no. 1.
3) MULTICAL® 603 and 803 can be ordered with Kamstrup ultrasonic flow sensors series, ULTRAFLOW®.
4) Standard cable lengths are 2.5 m, 5 m and 10 m. Can be extended up to 30 m with Cable Extender Box with extended flow info codes. Can also be
extended up to 100 m with Pulse Transmitter, however without extended flow info codes.
5) qp 0.6…15,000 m³/h.

Kamstrup A/S
Industrivej 28, Stilling
DK-8660 Skanderborg
T: +45 89 93 10 00
info@kamstrup.com