Professional Documents
Culture Documents
Contents
1 Process assignment acc. to HPH ....................................................................................................... 1
Its contents are not to be passed on, duplicated, exploited or disclosed without our express permission. All rights reserved, especially the right to apply for protective rights.
Note:
HF-00128 (2018-06-25)
Edition date: Designer of the HN: PDE of the related process: PLD of the related process:
2021-06-01 E-QD-B Norbert Kröger E-QD-B Norbert Kröger E-QS Dr. Tobias Becker
Replacing: HN20037 Edition: 2015-07-27 Pages: 9 Page: 1
Uncontrolled copy when printed E-SE-D2-MD: Andreas Kupezki, 2023-01-27
Page 2
HN20037: 2021-06-01
3 Level of confidentiality
This HELLA Norm is assessed as INTERNAL.
It is available for HELLA suppliers.
4 Normative references
The integration of Inspection and Special Characteristics in the drawing shall be executed according to
function-, production- and inspection-related aspects.
Herein, external requirements by bodies, public authorities and customers as well as HELLA-internal
requirements must be considered and may have to be agreed with the customer and supplier.
The following references apply to the current issue of each document, unless otherwise agreed.
ISO 286-1
Geometrical product specifications (GPS) - ISO code system for tolerances on linear sizes - Part 1: Basis of
tolerances, deviations and fits (ISO 286-1:2010)
ISO 128-1 Technical drawings — General principles of presentation (ISO 128-1:2003)
ISO 1101
Geometrical Product Specifications (GPS) - Geometrical tolerancing - Tolerances of form, orientation,
location and run-out (ISO 1101:2017)
HN22024
Technical product specification (TPS) – Tolerancing and general tolerances (HELLA-internal norm)
HN22025
Technical product specification (TPS) – Deviations from international standards
HN22026
Technical product specification (TPS) - Execution of component and product measurements
BMM-50-40-70
Identify and Control Special Characteristics and Inspection Characteristics (HELLA-internal process)
HF-00150
List of Special Characteristics (HELLA-internal form)
HN11020
Qualify and Control of Process (HELLA-internal norm)
VDA Joint Quality Management in the Supply Chain
A process description covering Special Characteristics (SC)
VDA Band 1 Documented Information and Retention
Guideline for control and retention of documentation within the framework of the product lifecycle –
particularly their classification
AD-00385 (former HP-C-509)
HELLA Quality Management - Guideline for Suppliers
Special Characteristics must be marked without exception in all technically relevant documents of the
product and process documentation and run like a common thread through product development and
production all the way from the customer requirements to the product manufactured under series conditions.
According to their importance for the product, Special Characteristics are subdivided into the categories
• SC/S – Special Characteristics related to safety
• SC/L – Special Characteristics related to legal and regulatory requirements
• SC/F – Special Characteristics related to functions and requirements.
For all documents that include Special Characteristics the recommendation for retention period of “VDA Joint
Quality Management in the Supply Chain - A process description covering Special Characteristics (SC)” has
to be followed.
Retention period (operating and archiving period):
➢ 30 years for Special Characteristics SC/S and SC/L
➢ 10 years for Special Characteristics SC/F
Besides that, customer specific requirements or higher requirements need to be considered.
In general, the specific requirements of “VDA Band 1 Documented Information and Retention” need to be
considered.
• Decorative properties
• Geometry-related dimensions
• Shape and positional tolerances
• Information on toothing, threading etc.
• Information on surface properties
• Information on heat and surface treatment, material and welding, etc.
• Characteristics related to the process, e.g., pull/push/shear forces, starting power
For automatic scan and interpretation of drawings this order must be followed strictly.
For better visualization in the drawing an upside-down triangle has to be used. It shall be applied near the
characteristic, so that a clear relation is given, the exact position is free to choose.
As a consequence of this the Inspection Characteristics must be included into the Control Plan and be
marked there accordingly, too. In the Control Plan the Inspection Characteristics will be marked with the
same sequence of characters “IC/P” in the classification column.
A marking of Inspection Characteristics in further documents is not required.
For automatic scan and interpretation of drawings this order must be followed strictly.
For better visualization in the drawing an upside-down triangle has to be used. However, to highlight the
special importance of the characteristic an additional rectangle will be attached on top to distinguish it from
an Inspection Characteristic. It shall be applied near the characteristic, so that a clear relation is given, the
exact position is free to choose.
Special Characteristics shall be defined unambiguous and therefore multiple dimensions (see following
picture) should be avoided when assigning a Special Characteristic. If it is not possible to avoid it at least it
must be possible to clearly assign test results to each of the individual dimensions.
In case of tolerance frames the assignment of a SC or IC must be done for each characteristic separately at
the right side of the tolerance frame (see following example).
---------------
Special Characteristics and Inspection Characteristics
according to HN20037: 2021-06-01
Total number of Special Characteristics and Inspection Characteristics:
SC/S - (Special Characteristics related to safety) = 0
SC/L - (Special Characteristics related to legal and regulatory requirements) = 0
SC/F - (Special Characteristics related to functions and requirements) = 1
IC/P - (Inspection Characteristics) = 0
---------------
Inspection level P1
Measured variables:
1) Proof of short-term-/machine capability Cmk for ISIR/PSW1
Calculation basis ≥ 50 pcs per tool/nest/cavity.
2) Proof of preliminary process capability Ppk
Calculation basis ≥ 125 pcs, e.g. collected in 25 samples at 5 pcs each.
3) Proof of long-term process capability Cpk or Ppk respectively with instable processes
Calculation basis: production period ≥ 20 days and ≥ 250 pcs (e.g. 2 x 5 parts per shift in 2-shift production:
400 parts after 20 production days; or 1 x 5 per shift in 1-shift production: 250 parts after 50 production
days).
4) The collection of the random samples for preliminary and long-term process capability must be
accompanied by a process control card (SPC-card). It must be maintained over the entire production period.
The test frequency must be selected to ensure a sensible statistical process control suitable for the
production process. Random sampling size is same as defined for 2) and 3).
Re. 1-4: For processes with very small production volumes (e.g., annual requirement produced in < 5 shifts)
or for special processes (e.g., production of sealing rings in a 50-cavity tool), special agreements can be
made between manufacturer and customer.
If short-term capability, preliminary capability or long-term process capability cannot be proven, 100% testing
of the characteristic is required. If 100% testing is planned anyway (e.g. in highly automated lines), process
capability and trends analyses are not mandatory (nevertheless recommended for process improvements).
In case of destructive tests or very complex tests, a suitable random sampling test including control card
monitoring may be executed instead. The actual reaction plan must be described in the Control Plan, in
agreement with the internal customer or HELLA for external suppliers.
Documentation (HELLA-internal: qs-STAT-reports):
Re. 1), 2), 3) Initial:
• Capability indices, distribution, mode of calculation
• Actual value, mean value, standard deviation
Re. 4) Permanent:
• SPC-card
Attributive characteristics:
100% testing must be executed throughout the entire production period.
The documentation/proof of 100% testing (measured variables as well as attributive characteristics) will be
determined project-specifically.
Inspection level P2
1) Proof of short-term/machine capability (Cmk) for ISIR/PSW
Calculation basis ≥ 50 pcs per tool/nest/cavity.
2) Regular random sampling for actual values (frequency depends on the potential changes in the process,
such as material batch changes etc.) with random sample size of typically 3-5 pcs per tool/nest/cavity. For
these characteristics, it is not mandatory to keep a control card.
Documentation (HELLA-internal: qs-STAT-reports):
Re. 1) Initial:
• Capability indices, distribution, mode of calculation
• Actual value, mean value, standard deviation
Re. 2) Permanent:
• Actual values
Inspection level P3
1) Proof for ISIR/PSW: Actual values lie within the specification. Sample size ≥ 5 pcs per tool/nest/cavity.
2) Regular random sampling for actual values (frequency depends on the potential changes in the process,
such as material batch changes, tool wear depending on the number of shots etc.) with sample size of
typically 3-5 pcs per tool/nest/cavity. For these characteristics, it is not mandatory to keep a control card.
Documentation:
Re. 1) Initial:
• Actual values
Re 2) Permanent:
• Actual values
Inspection level P4
The verification requirements of inspection level P4 correspond to those of P3, but they are used for
attributive characteristics or measured variables which will be tested with a gauge during production.
1) Proof for ISIR/PSW: Actual values lie within the specification. For attributive characteristics a clear
o.k./n.o.k. result is sufficient. Sample size ≥ 5 pcs per tool/nest/cavity.
2) Regular random sampling with an attributive test, e.g. o.k./n.o.k. gauge (frequency depends on the
potential changes in the process, such as material batch changes, tool wear depending on the number of
shots etc.) with sample size of typically 3-5 pcs per tool/nest/cavity.
Documentation:
Re. 1) Initial:
• Actual values (measured variables) or test result o.k./n.o.k. (attributive characteristics)
Re. 2) Permanent:
• Test result o.k./n.o.k.
Inspection level P5
1) Proof for ISIR/PSW: Actual values lie within the specification. For attributive characteristics a clear
o.k./n.o.k. result is sufficient. Sample size ≥ 5 pcs.
Inspection level P5 is applied for all Inspection or Special Characteristics which change very slowly, if at all,
and which do therefore not require series-accompanying monitoring. A deviating random sampling number
can be defined (e.g. in case of high-effort or destructive tests), it does, however, require agreement with the
internal customer or HELLA. P5 characteristics are to be tested 1x per year unless agreed otherwise.
Specific HELLA-internal CoP (Conformity of Production) test frequencies are defined in AD-HN29201-01.
Documentation: Actual values (measured variables) or test result o.k./n.o.k. (attributive characteristics)
Inspection
P1 P2 P3 P4 P5
level
1.) Short-term/machine
capability Cmk Actual values lie Actual values lie
2.) Preliminary process within the within the
Short-term/machine Actual values lie specification or clear specification or clear
Proof capability Ppk within the
capability Cmk o.k./n.o.k. result (for o.k./n.o.k. result (for
3.) Long-term process specification
attributive attributive
capability Cpk or Ppk for characteristics) characteristics)
instable processes
1.) ≥ 50 pcs per
Initial
tool/nest/cavity
Extent of 2.) ≥ 125 pcs e.g. collected ≥ 50 pcs per ≥ 5 pcs per ≥ 5 pcs per
≥ 5 pcs
sampling in 25 samples, 5 pcs each tool/nest/cavity tool/nest/cavity tool/nest/cavity
3.) Production period
≥ 20 days and ≥ 250 pcs