You are on page 1of 14
AVEVA Multi Discipline Supports BX or Free (BEDPLATE) r ey (eer) 5 r <7. STEEL, x PABRICATE ~~ OVER LENGTH FOR SITE TRIM DIM2 (000mm) LADDER RACK (REF) 4 ELEVATION TYPE A: AS DRAWN TYPE B: MIRROR IMAGE OF TYPE A TYPE C: ORIENTATION DRAWING SUPPLIED BY PDMS ADP DRAWING. waters. — | aarzniat | APPLICATION SUMMARY SUBIC” | DEFAULT T | Goxeoxat 2 | soxsori0 sore) “or'stEe 3 | tooetd0xtzn d mee 8 = ; = 3 = 1] Soxboxar 2 | Boxboe101 c As DRAWING 53 | 100xt60eie 4 ne 3 = 8 = : = 8 = of STEELNORK OVERLAP FROM DEFAULT FILE, x SITE TRIM LENGTH FROM DEFAULT FILE 4 APPLICATION MAXIMUM LENGTH FROM TEMPLATE, IF FT22 1S REQUIRED IT MUST BE CALLED UP AS A SEPARATE ITEM CABLE RACK FIXING BY CONTRACTOR CABLE SUPPORT sTD-Dii-DIMe L BRACKET E.G. CT01-500-500 P TOL ‘STANDARD Avsve [Ph ‘A SHEET 1 0 AVEVA Multi Discipline Supports > FaBpicaTe usr. sth. OVER LENGTH Bust. (BEDPLATE) (REF.) FOR SITE TRIM ELEVATION TYPE A: AS DRAWN ‘TYPE B: MIRROR IMAGE OF TYPE A. TYPE C: ORIENTATION DRAWING SUPPLIED BY PDMS ADP DRAWING. ‘APPLICATION MATERIAL DEFAULT SUFFIX’ | ‘STEEL stzes @0x60%x8L, 80x80%10L, 100x100x 124 MATERIAL ‘TYPES ‘SUMMARY 8.7 METRES OF STEEL G0x80x81, 80x80x10L, 100x 100% 12L, ‘AS DRAWING eveveun-|evecaun-| ok STEBLWORK OVERLAP FROM DEFAULT FILE. x SITE TRIM LENGTH FROM DEFAULT FILE. 4 APPLICATION MAXIMUM LENGTH FROM TEMPLATE. IF FT22 15 REQUIRED IT MUST BE CALLED UP AS A SEPARATE ITEM. CABLE RACK FIXING BY CONTRACTOR. cove CABLE SUPPORT ‘STD-DIMi-DIMz L BRACKET EG. CT02-500-500 AVEVA Multi Discipline Supports DIM 3. (000m) FABRICATE. x LENGT! (Typ.) (BEDPLATE REF.) PLAN OR ELEVATION TYPE A: AS DRAWN TYPE B: MIRROR IMAGE OF TYPE A TYPE C: ORIENTATION DRAWING SUPPLIED BY PDMS ADP DRAWING. APPLICATION waTeRc sumaRy | MATERIAL trees | (inte Cnossaaes) | “SUrFIK™ | DEFAULT 60x60x8L Sose0s 101 Toontooxtan 4.8 METRES OF STEEL. 1.0 METRE EXTRA STEEL REQUIRED IF 100x100x12L ISD. GOxGOxEL, 80x80x10L 100x100x12L, AS DRAWING erecsune|erecsone ok STEELWORK OVERLAP FROM DEFAULT FILE. x SITE TRIM LENGTH FROM DEFAULT FILE. 4 APPLICATION MAXIMUM LENGTH FROM TEMPLATE. IF FT22 IS REQUIRED IT MUST BE CALLED UP AS A SEPARATE ITEM. CABLE RACK FIXING BY CONTRACTOR. CODE CABLE SUPPORT S7O-Mt-D2-Daed-Mies GOAL POST fc. eTO4-1000-$00-500-800 AVEVA Multi Discipline Supports FABRICATEX OVER LENGTH FOR SITE TRIM (TYP) PLAN OR ELEVATION SUPPLIED BY PDMS ADP DRAWING. "APPLICATION MATERIAL SUMMARY TERIAL (WITH 2 CROSSBARS) DEFAULT. STEEL SIZES ‘BOx6OxBL 80x80x10L 100x100xi2L AS DRAWING. —_ ok STEELWORK OVERLAP FROM DEFAULT FILE. x SITE TRIM LENGTH FROM DEFAULT FILE. # APPLICATION MAXIMUM LENGTH FROM TEMPLATE. IW FT22 IS REQUIRED IT MUST BE CALLED UP AS A SEPARATE ITEN. CABLE RACK FIXING BY CONTRACTOR. CODE CABLE SUPPORT ‘STD-DIM1-DIM2-DIMa-DIMe SUPPORT FRAME E.G. C¥05-1000-500-500-500 AVEVA Multi Discipline Supports REF-ELV. TYPE A:aS DRAWN TYPE Bas DRAWN TYPE F:MIRROR IMAGE OF A TYPE G-IRROR (MAGE OF B TYPE L:PDMS ADP DRAWING TYPE MPDMS ADP ORAWING EXIST, a:f a] REF.ELV. TYPE C:s DRAWN TYPE Das prawn TYPE H30RROR IMAGE OF C TYPE J:MIRROR IMAGE OF D TYPE N-PDMS ADP DRAWING TYPE PDMS ADP DRAWING ‘APPLICATION DEFAULT MATERIAL ‘SUMMARY aoe ‘80x80x10L, 100x100x 121. (60x80x8L. ‘80x80x10L, 100x100x 121, AS DRAWING avecaen-|oveosen- ok STEELWORK OVERLAP FROM DEFAULT PILE. x SITE TRIM LENGTH FROM DEFAULT FILE. ‘# APPLICATION MAXIMUM LENGTH FROM TEMPLATE. IF FT22 IS REQUIRED [T MUST BE CALLED UP AS A SEPARATE ITEM. CABLE RACK FIXING BY CONTRACTOR. (cove CABLE SUPPORT SrD-piMi-DIMz CANTILEVER BRACKET EG. CT06-500-500 AVEVA Multi D: pline Supports X FABRICATE OVER EAT, EXIST. STEEL OR FT22 FOR SITE TRIN (BEDPLATE. REF.) ELEVATION APPLICATION DEFAULT STEEL SIZES MATERIAL, SUMMARY 60x60x8L oMErRES 80x80x 101 OF STEEL 100"100x12L. exvousen- NOTES IF FT22 IS REQUIRED IT MUST BE CALLED UP AS SEPARATE ITEM. CABLE RACK FIXING BY CONTRACTOR. ok STEELWORK OVERLAP FROM DEFAULT FILE. x SITE TRIM LENGTH FROM DEFAULT FILE. ‘ APPLICATION MAXIMUM LENGTH PROM TEMPLATE. (cove CABLE SUPPORT SrD-piMi-DIMz INVERTED T POST EG. cT07-500-500 AVEVA Multi Discipline Supports EXIST, STEEL (BEDPLATE ~ REF.) DIM 4. ( 41000mm) REP. ELV. | ELEVATION ‘APPLICATION MATERIAL MATERIAL, DEFAULT. ‘SUMMARY peEAGLT ‘SUFFIX ‘80x80x8L, 45 METHES ‘80x80x10L, OF STEEL 100xt00x12L, NOTES IF F722 IS REQUIRED [T MUST BE CALLED UP AS SEPARATE ITEN. HVAC DUCTWORK FIXING BY CONTRACTOR. 4 STESLWORK OVERLAP FROM DEFAULT FILE. x SITE TRIM LENGTH FROM DEFAULT FILE. # APPLICATION MAXIMUM LENGTH FROM TEMPLATE. HVAC SUPPORT y-o-Dexe-Di-Die SUPPORT FRAME E.G. DT01-1000-500-500-500 VANTAGE Plant Design - Multi Discipline Supports Application TYPE 1 ELEVATION TYPE 3 ELevaniON TYPE 2 ELEVATION TYPE 4 ELEVATION TYPE 6 — ELEVATION ‘uareRia, seuRCTION 100100 150 2 90 PFC 200 x 99 FF DESCRIPTION [cove FBO! MATL-ORE MDS FRAME BRACING VANTAGE Plant Design - Multi Discipline Supports Application “T a TYPE 7 ELEVATION TYPE 9 ELEVATION TYPE 10 ELEVATION MDS FRAME BRACING SSE Poe ae AVEVA Multi Discipline Supports o& STEELWORK OVERLAP FROM DEFAULT FILE. EXISTING STEELWORK ‘ SITE TRIM LENGTH FROM DEFAULT FILE. (Of BEDPLATE 4 APPLICATION MAXIMUM LENGTH FROM TEMPLATE. ‘OVER LENGTH FOR SITE TRIM (1000 Max.) FOR PLATE SIZE ‘SBE TABLE. je I PLAN OR ELEVATION TYPE A: AS DRAWN TYPE B: MIRROR IMAGE OF TYPE A. TYPE C: ORIENTATION DRAWING SUPPLIED BY PDMS ADP DRAWING. MATERIAL, wateRiaL | APPLICATION | O/ALL SIZE DEFAULT SUMMARY SUFFIX” | DEFAULT 60x80x8L. 80x80x10L 100% 100x12L 127xB4e14 C 9.1 METRES OF STEEL + BLATE GOxBOx8L, 80x80x10L 100% 100x12L te7Kbaxl4 C AS DRAWING execsun-|evecsun-| cove ‘STD-DIM1-DIMz EG. FT04-800-500 Pa pero TOA L BRACKET AVEVA Multi Discipline Supports DATUM ZZ Pie FABRICATE OVER LENGTH DIM 1 FOR SITz TRIM (1000mm) —— EXIST STEEL OR FT22 (BEDPLATE REF) ELEVATION TYPE A: AS DRAWN TYPE B: MIRROR IMAGE OF TYPE A. TYPE C: ORIENTATION DRAWING SUPPLIED BY PDMS ADP DRAWING. x SITE TRIM LENGTH FROM DEFAULT FILE. ## APPLICATION MAXIMUM LENGTH FROM TEMPLATE. APPLICATION MATERIAL, MaTeRiAL | APPLICATIO SUMMARY SUFFIX” | DERAULT (G0x60x81. 80x80x10L, 100x100x 12 1.1 METRES OF STEEL ‘60x60x8L 80x80x10L, 100x100x 2. AS DRAWING. DESCRIPTION cove POST srD-piMt EG. FT07-500 AVEVA Multi Discipline Supports i500 wax(100x100x12L & 152x60() 1000 WAX(60x60x8 & 80x80x10L) FABRICATE * ‘OVER LENGTH FOR SITE TRIM Typ) 4 STEELWORK OVERLAP FROM DEFAULT FILE. x SITE TRIM LENGTH FROM DEFAULT FILE. = APPLICATION MAXIMUM LENGTH FROM TEMPLATE. ‘APPLICATION DEFAULT MATERIAL MATERIAL SUMMARY SUFFIX” | STEEL sizes 4.6 METRES OP STEEL. 60x60xaL, ‘80x80x10L, 1.0 METRE EXTRA STEEL REQUIRED IF 100x100x12L 1008100x12L. ‘OR 182x89f IS USED 152n89{ cove ‘STO-DIMt-DIM2-DIM3-DIM4 GOAL POST .. FT08-1000-500-500-800 AVEVA Multi Discipline Supports EXIST. STEEL Fre2 (BEDPLATE) (REF) pia ‘# 1500 MAX(100x12L & 152x89() * 1000 MAK(6Ox8L & 80x101) PLAN OR ELEVATION ok STEELWORK OVERLAP FROM DEFAULT FILE. x SITE TRIM LENGTH FROM DEFAULT FILE. # APPLICATION MAXIMUM LENGTH FROM TEMPLATE. "APPLICATION MATERIAL SUMMARY MATERIAL | "DEFAULT SUFFIX’ | STEEL SIZES 4.9 METRES OF STEEL. e0x60x8L, 1.0 METRE EXTRA STEEL 80x80x10L, REQUIRED IF 100x12L OR 100x100x12L, 152x89{ IS USED 152x80{ SUPPORT FRAME ‘S7D-DIMi-DIM2-DIM3-DIMe E.G. FTOB- 1000-500-500-500 AVEVA Multi Discipline Supports 1000(MAX) ‘50mm, 1000(MAX)_ 1000(MAX) EXIST Dim. exist [| 01 ] STEEL [ows STEEL REPEL. REPEL 450x75x10 STIFFENER PLATE SITE CUT & FIT TO SUIT. (FOR COLUMNS ONLY) (FOR COLUMNS ONLY) (FOR BEAMS ONLY) TYPE Aas DRAWN TYPE Bas prawn TYPE Cas prawn TYPE F MIRROR IMAGE OF A TYPE GwiRROR IMACE OF B TYPE Ha iRROR (MACE OF C TYPE Lbus app DRAWING TYPE Mepms ADP DRAWING TYPE NebMs ADP DRAWING DIM. 1 __-450x75x10 STIFFENER PLATE Sire cUY a FIT TO SUIT. (FOR BEAMS ONLY) EXIST ' TYPE Das DRAWN ea] TYPE JMIRROR IMAGE OF D TYPE Prpms ADP DRAWING sonn,| 1000(MAX) REPEL. ‘APPLICATION MATERIAL DEFAULT MATERIAL, SUMMARY steel sizes | SUFFIX ‘60x80x8L, ‘80x80x 101, 100x100812L 152489 (cove CANTILEVERED SrD-piMi-DIMz BRACKET EG. FT14-800-500

You might also like