You are on page 1of 3

MOD.

PANEL = MARCA =
TIPO DE CASA = UNIFAMILIAR INT. PRINCIPAL =
CARGA DE DISEÑO = 14,575 W
KVA DESCRIPCION TUBERIA
0.90 Luminarias 1/2´´
2.4 Tc (uso general) 1/2´´
1.5 Tc (uso especiall) 1/2´´
1.5 Tc (uso especiall) 1/2´´

CARGA A FUTURO

6.3
CARGA INSTALADA (KVA ) = 12,146 KVA
Luminarias 0.9 KVA
Tomacorrientes (UG) 2.4 KVA
Demanda Máxima 9.72 KVA
Carga Fase A 6.3 KVA
Carga Fase B 5.9 KVA
CUADRO DE CARGAS - GRUPO #
#CIRCUITOS = TIPO DE BREAKER = THQL - THQP
NOMBRE DE LA EMPRESA CONTRATISTA =
VOLTAJE = 120/240 FASE = MONOFASICA
CALIBRE BRK No. A B No BRK CALIBRE
12 15 1 2 30 10
12 20 3 4 30 10
12 20 5 6 20 12
12 20 7 8 20 12
9 10 20 12
11 12
13 14
GA A FUTURO 15 16
CARGA A FUTU
17 18

46 KVA
Carga de Reserva = 2,429.2 KVA
Desbalance de Carga 0.4 KVA
Factor de Demanda 0.8 INTERRUPTOR PRINI
Carga de Diseño 14,575 KVA
Corriente de Diseño 60.73 A
HQL - THQP

TUBERIA DESCRIPCION KVA


3/4´´ Tc (A/C) 0
3/4´´ Tc (A/C) 3
1/2´´ Tc (lav) 1.5
1/2´´ Tc (nev) 0.6
1/2´´ Tc (bom) 0.75

CARGA A FUTURO

5.9

TERRUPTOR PRINICIPAL =