You are on page 1of 5

ELEVATOR EXPERT STEP WITH THE WORLD

MCTC-MIB-A
Monitoring information board manual

V0.00

Suzhou Monarch Control Technology Co., Ltd.


MCTC-MIB-A monitoring information board introduction

MCTC-MIB-A

Ⅰ.Handware and installation


1、real object photo:

2、Diagram and terminal:

1)24V、COM need external power supply;


2)J11 used to connect computer, connect the MIB board in the monitoring center to the serial port of
computer;board in the machine-room connect to the NICE3000;
3)J12 used for 485 communication ,connect the MIBin the monitor center to the MIB:MOD+、
MOD- in the machine-room;

-1-
MCTC-MIB-A monitoring information board introduction
4)J14、J15 for terminal matching,connect the board on the monitor center to part 1,and connect
the board on the machine room to part 2(default side to part 2);
5)Indication light
A、OK:the board power, ARM run normal;
B、S1:computer communication is ok;
C、S2:485 communication normal;
3、wiring diagram :

-2-
NICE3000
NICE3000
DB9 DB9
NICE3000 DB9

Room 2
Room 1

Machine
Machine

Room N
Machine
232
232
232

J11 J11 J11

TX RX GND TX RX GND TX RX GND


RJ45 RJ45 RJ45

ARM ARM ARM


Pow- Pow- Pow-
1 2 1 2 1 2
J14 er J14 er J14 er
J15 J15 J15
S3 S2 S1 OK S3 S2 S1 OK S3 S2 S1 OK
24V MOD+ MOD- COM 24V MOD+ MOD- COM 24V MOD+ MOD- COM

J12 J12 J12

-3-
485

nication
Commu-

J12

24V MOD+ MOD- COM


S3 S2 S1 OK
J15
J14
1 2
Power
ARM

RJ45 TX RX GND

J11
232

COM1
Room

PC
room
Monitor

Monitor
MCTC-MIB-A monitoring information board introduction
MCTC-MIB-A monitoring information board introduction
Function code:

Min. Oper Remark


Code Name Setting range Default
unit ation
Software
F0-00 Software version 0~65535 1 ●
version
0:NICE1000
F0-01 System name 1:NICE3000 1 1 ☆
2:NICE5000/NICE2000
Set MIB in
themonitor
center as
F0-02 Address 0~255; 1 0 ☆ 200;MIB in
the machine
room as 1~
32;
Set the
communicatio
0:9600bps
n paud rate of
1:19200bps
MIB in the
F0-03 Paud rate 2:38400bps 1 0 ☆
monitor
3:57600bps
center and
4:115200
computer
serial port
Set the
communicatio
n paud rate of
Paud rate of
MIB in the
F0-04 Modbus2/Zigbee/G 0~4 1 0 ☆
monitor
PS
center and
the 485 In the
machine room
Set the
single
elevator
Monitor the
amount need
F0-06 single elevator 1~32 1 1 ☆
to monitor by
amount
the MIB in the
monitor
center

Min. Oper Remark


Code Name Setting range Default
unit ation
0:485 communication;
Monitoring 1 : Zigbee
F1-00 1 0 ☆
method communication ;
2:GPS communication;

☆:parameter is adjustable ;
● :Parameters should be remained as defaulf, no change. 。