You are on page 1of 1

Quality Test & Engineering Services

Office No.03,Plot No. W-120,Near Metropolitan Exichem,MIDC Phase II, Dombivli (East) – 421 204
Tel.: 0251-2437575 / 8828607575, Email: customerservice.qtes@gmail.com / info.qtes@gmail.com QTES/FM/38
Test Record Page 1 of 1
Lab Ref No. : C3295 Report Date : 22-11-2022

Ref. No. : 102 Ref. Date : 03-11-2022


P.O. No : P.O. Date :
Customer Remark : Test Completed on : 22-11-2022
Sample Description : Nil
Material Description : S.S.Round Bar
Material Specification : ASTM A 182 Grade F 316:2021/ASTM
A 182 Grade F 316L:2021
Material Dimension : 40mm Ø
Heat No : V03B24
Stamped By: TPL-1327
Discipline: Mechanical, Group: Metals & Alloys
IGC Practice 'E' Test Report Test Method : ASTM A 262:2015 (2021)
Equipment : ST-A1
Result
Test Duration 15 Hours
Sensitized 675°C for 1 Hours
Test Details Corrosion environment = Boiling copper, copper sulphate, 16% of
sulphuric acid solution
Loading Date: 19-11-2022 Time: 6.00 P.M.
Unloading Date: 20-11-2022 Time: 9.00 A.M.
Specimen Size (mm) (WxTxL) 22.68 X 6.10 X 100.52
Mandrel Size = 1t = 6.00
Angle Of Bend 180°
Magnification 20X
#Observation No evidence of any cracks, fissure or orange peel seen.
Result. Satisfactory.
Microstructure Test Report (On cross section of Bend Portion of IGC-E Piece)
Etchant 10% Oxalic Acid (Electrolytic)
Magnification. 250X
Observation No evidence of any cracks or grain dropping seen.
Result Satisfactory
…………..END OF REPORT………….

______________ _____________________
Checked By Reviewed & Authorised
Signatory