Maintenance Error Code Table - Central Panel Display System

CPDS
SDS 31-65-00,09

REFERENCE
Documentary Unit SDS 31-65-00,09

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
References/Effectivity Maintenance Error Code Table - Central Panel Display System CPDS
Language EN( en)
Issue Date 2014.12.01

EFFECTIVITY
Model EC135
Version
Serial Number 0005-0008, 0011-0012, 0015-0018, 0020-0036, 0038-0043, 0045-0046,
0048-0053, 0055-0061, 0064, 0066, 0068, 0070-0078, 0080-0090, 0092-
0093, 0095-0102, 0104, 0106, 0109-0113, 0115-0120, 0123-0134, 0136-
0141, 0143-0144, 0147, 0149, 0151, 0153-0159, 0161-0169, 0174-0175,
0178-0179, 0181-0182, 0184-0188, 0190-0193, 0195-0199, 0204-0205,
0207, 0209-0210, 0212, 0215, 0218-0223, 0225-0240, 0242-0253, 0255,
0257, 0259-0260, 0262, 0265, 0267-0278, 0280-0285, 0287-0294, 0296-
0298, 0300, 0303, 0305-0313, 0315-0327, 0329-0335, 0337-0341, 0343-
0348, 0350-0352, 0354-0358, 0360-0368, 0370-0377, 0379-0405, 0407-
0431, 0433-0444, 0446-0449, 0451-0473, 0476-0500, 0502-0507, 0509-
0511, 0513-0515, 0517-0528, 0530-0534, 0536, 0538, 0540-0541, 0543-
0545, 0547-0548, 0550-0552, 0554-0557, 0559, 0561-0564, 0566-0579,
0581-0591, 0593, 0596-0602, 0604-0607, 0609-0616, 0618, 0620, 0622-
0628, 0630-0643, 0646-0647, 0649-0658, 0660-0673, 0675, 0677-0678,
0680-0684, 0686-0692, 0694-0707, 0709-0721, 0723-0727, 0729-0730,
0732-0741, 0743-0755, 0757-0766, 0769-0773, 0775-0776, 0778-0779,
0781-0790, 0792-0795, 0797-0801, 0803-0807, 0809-0811, 0813-0819,
0821-0825, 0827-0868, 0870-0885, 0887-0930, 0932-0934, 0936-0943,
0945-0948, 0950-0957, 0959-0967, 0969-0974, 0976-0979, 0981-0982,
0984-0987, 0989-0991, 0993-0994, 0996-1001, 1003-1004, 1006-1008,
1010-1014, 1016-1017, 1019-1022, 1024-1025, 1027-1031, 1033-1034,
1036-1037, 1039-1040, 1042-1089, 1091-1114, 1116-1126, 1128-1140,
1142-1171, 1173-1274, 1276

STATUS
Type of modification U
Description M
Reason for update Completely revised
Maintenance work affected Yes

Effectivity : CPDS

A. VEMD Error Code Table

Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
NOTE
Information in the error code table are only used to help identify errors.

NOTE
The effectivities for the different software configurations (V2002, V2003 and V2005)
are given in the titles of the individual tables.

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
NOTE
Disregard error codes 9, 11, 27, 34, 35, 39, which can only occur up to and including
software version V2002.

The following error code table is effective for All starting with software V2002
Table 1 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure Sources
0 CHECK_DATA_CONF Consistency check between VEMD VEMD
different part numbers and GS
identification written during ATP in VEMD
software and : -
PARTNUMCHAN=B19030J* for non
NVG version, B19030G* for NVG
version - PARTNUMMODC=B19030J*
for non NVG version, B19030G* for NVG
version - MPARTNUMCHAN= C19184P*
for non NVG version, C19184S* for NVG
version - MPARTNUMMODC=
C19186D* for non NVG version,
C19186G* for NVG version -
GSVERSION= 6.* N.B.: “*” replaces any
letter or number
0 CROSS_DATA_ENG Engine type comparison through the VEMD
TYP crosstalk
0 CROSS_OEITRQINC OEI TRQ INC discrete comparison VEMD
through the crosstalk
0 TEST_CONN_IDENT Connector identifiers surveillance VEMD
0 CHECK_DATA_REFP Computation of reference voltages and VEMD
identification information from the other
module checksum CSom
0 CHECK_DATA_AC Computation of AC options checksum VEMD
CSt
0 CHECK_DATA_LOA D Computation of compensation sensor VEMD
checksum CSc
0 CHECK_DATA_EEPR Check the range of dataloadable value VEMD
OM from EEPROM2
0 CROSS_DATA_PRG Equality of software versions (excluding VEMD
index): SOFTVERSION and
SOFTVERSIONOTH
Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
Table 1 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure Sources
0 CROSS_DATA_CONF Consistency check between modules VEMD
definitions (EEPROM1 and EEPROM2):
- Equality of VEMD part numbers:
PARTNUMCHAN, PARTNUMOTH,
PARTNUMMODC and PARTNUM stored
in the code

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
0 CROSS_DATA_REFA Other module reference voltages and VEMD
identification data checksum CSom on
the channel identical to CSmo
exchanged through the cross-talk
0 CROSS_DATA_AC AC options checksum (CSt) exchanged VEMD
through the cross-talk
0 CROSS_DATA_COMP Compensation sensor checksum (CSc) VEMD
exchanged through the cross-talk
0 SURV_CHARGE_CP At the end of each basic cycle, Basic VEMD
U software verifies during GSV IT waiting,
that software activity is less than 50 ms
1 TEST_CPU 68332 used external RAM test: - Write VEMD
the value $5555 - Read and compare to
$5555 - Write the value $AAAA - Read
and compare to $AAAA Computation of
level B program code checksum
2 TEST_ASIC IOM pattern registers reading test: Read VEMD
the first pattern register: $AAAA Read
the second patten register: $5555
3 TEST_ACCES_GS Reticules are sent to GSV to check the VEMD
good running of the securities; the test
securities are: - Parity - Serial line (0
value words sent) - Overflow capacity
(290 reticles) - False reticule
(unforeseen reticule) - 4 Reticule/Colour
overlap RAM 1 and 2
4 TEST_BF_GS_IN GSV failure if IRQ6 (It GS-OK) and VEMD
(Receive error = 1 or BFRET = 1 or FIFO
overflow)
5 TEST_BF_GS RAM1 and 2 reticle color test GSV VEMD
failure if IRQ6 (It GS-OK) and BFXY0..3
=1
6 CHECK_DATA_REFA Computation of reference voltages for VEMD
other module and identification
information checksum CSmo and
computation of module reference
voltages checksum CSm
10 TEST_LOOP_HF_BF_ Every FREQ can be connected with the VEMD
A FREQTEST (TP14) by a multiplexer
before ASIC IOM. Software puts
FREQTEST on the tested entry and
verifies the value given by ASIC IOM
Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
Table 1 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure Sources
12 TEST_CHAIN_ANA_ * Groups gain and offset on each module VEMD
are computed. For each group a
comparison is done with MIN and MAX
value (refer to Table )
13 TEST_CHAIN_ANA_ Gains and offset on other module are VEMD
OTH_* computed. For each group a comparison

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
is done with MIN and MAX value (refer
to Table )
14 SURV_ALIM_OTHER Test of ASIC IOM values : filtered +-15 V VEMD
1 COM filtered 5 V other filtered +-15 V
other equation : failure if (15C.
(15.5+15.5)) is true, during 16
consecutive cycles
15 SURV_ALIM_OTHER Test of ASIC IOM values : filtered +-15 V VEMD
2 COM filtered 5 V other filtered +-15 V
other equation : failure if (5.15C.15) is
true, during 16 consecutive cycles
16 TEST_BF_IOM_ACQ Verification of the IOM analogue VEMD
acquisition status
17 SURV_CPU 68332 used external RAM test (except VEMD
RAM used by interrupts): - Write the
value $5555 - Read and compare to
$5555 - Write the value $AAAA - Read
and compare to $AAAA Computation of
level B program code checksum
18 SURV_DOM_TCJ TOTCJ value domain checking VEMD
19 SURV_ENGTYP_ME engine type memorisation surveillance VEMD
M
20 CROSS_DISC Dissimilarity check between discrete VEMD
values computed by a module and
corresponding discrete inputs received
through the crosstalk
21 SURV_OEITRQ_ME P1/P2 respectively T1/T2 engine type VEMD
M memorisation surveillance
22 CROSS_P0 Dissimilarity check between P0 value FADEC1
acquired by a module and value
received through the crosstalk
23 CROSS_T0 Dissimilarity check between OAT value FADEC1
acquired by a module and FADEC
values
24 CROSS_TOT_R Dissimilarity check between TOT_R VEMD
value acquired by a module and value
received through the crosstalk
25 CROSS_FLI Dissimilarity check between FLI value VEMD
computed by a module and value
received through the crosstalk

Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
Table 1 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure Sources
26 CROSS_NVG Dissimilarity check between NVG value VEMD
computed by a module and value
received through the crosstalk (test
performed in flight condition only)

The following error code table is valid for All starting with software V2012

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
Table 2 - VEMD error code table for All starting with software V2012
Failure Code / Test Name Failure Description Possible Failure Sources
27 CROSS_IAS Dissimilarity check between IASBUS IAS sources (ADC, FCDS,
value computed by a module and value AFCS)
received through the crosstalk

The following error code table is effective for All starting with software V2002
Table 3 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure Sources
28 SURV_CAD_FAIL CAD Failure detected CAD HW
29 SURV_CADTALK An arinc 429 link failure is declared if the CAD Switched OFF
label 030 (Mode Management) is not during flight -- or -- CAD
received three times successively HW -- or -- wiring CAD
CTK- VEMD
30 FAIL_FADEC FADEC failed FADEC
31 SURV_FADEC A RS422 FADEC link failure is declared FADEC -- or -- FADEC
if an invalid frame has been received or RS422 wiring VEMD
no valid frame has been received 3
times successively for PW engine or TM
engine
32 TEST_HEATER If DISINOUT2 = 1 => HEATER ON VEMD
(command), then DISINOUT0 value in
ASIC IOM must be 0 (BF heating)
33 TEST_FAN DISINOUT1 = 1 => Command Fan ON VEMD
The reading of FAN value after at least
300 ms in ASIC IOM must be lower than
1.2 V (Start state) Nota : Do not perform
TEST_FAN if temperature is under 0 oC
36 TEST_WRITE_NVM One EEPROM cell writing is requested, VEMD
the software verifies after writing the
written value (by reading it in the
EEPROM cell)
37 TEST_ACCES_LUM Gcj (Corrected gain day/night) and, for VEMD
NVG version, Gcn (corrected gain NVG)
are read in the serial BAL EEPROM
during power-on if Gcj failure (Gcj
greater or equal than 5 or Gcj less or
equal than 0.5) set Gcj to 1 for NVG
version: if Gcn failure (Gcn greater or
equal than 4) set Gcn to 1.5

Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
Table 3 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure Sources
38 TEST_ALIMOUT On channel A : EOP2 power supply is VEMD
read by ASIC IOM and must be equal at
least to 10 V +10 mV / - 100 mV On
channel Ap : EOP1 and XMSNOP power
supply are read by ASIC IOM and must
be equal at least to 10 V +10 mV / - 100

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
mV
39 TEST_BUTTONS During Power-on, all buttons have to be VEMD
released on message request
40 TEST_LOOP_ARINC When TP8=1, crosstalk OUT is VEMD
connected to crosstalk IN and to the
three other inputs with label 377 issued
41 TEST_LOOP_RS422 When TP8=1 RS422 OUT is connected VEMD
to RS422 IN
42 TEST_ASS_LUM Verifies FLUM is not null VEMD
43 SURV_CROSSTALK A cross-talk failure is declared if in bi- VEMD other chanel -- or -
channel and the label 030 (Mode - wiring VEMD1 CTK
Management) is not received three VEMD 2 CTK
times successively
44 SURV_BRT_BUTTON Verifies BRT buttons are not stuck VEMD
S
45 SURV_DOM_N1 N1 value domain checking N1 sensor engine 1 -- or -
- wiring N1 sensor engine
1 VEMD
49 SURV_UNDOFF_BC BC 1under offset checking Measurement shunt
Battery current 1 -- or --
wiring BC Shunt
VEMD
50 SURV_DOM_BC BC 1value domain checking Measurement shunt
Battery current 1 -- or --
wiring BC Shunt
VEMD
52 SURV_DOM_SLING SLING LOAD value domain checking Hook load measurement
device
56 SURV_DOM_EOP EOP1 value domain checking EOP 1 sensor -- or --
wiring EOP 1 VEMD --
or -- wiring VEMD power
supply EOP 1 sensor

The subsequent error code table is valid for All starting with software V2012
Table 4 - VEMD error code table for All starting with software V2012
Failure Code / Test Name Failure Description Possible Failure Sources
57 SURV_DOM_VNE VNE value domain checking VEMD
58 CROSS_VNE Dissimilarity check between VNE value VEMD
acquired by a module and value received
through the crosstalk
Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
The following error code table is effective for All starting with software V2002
Table 5 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure Sources
60 SURV_TOT_FADEC TOT FADEC validity checking FADEC 1 when VEMD
lane “L” -- or -- FADEC 2
when VEMD Lane “R”
61 SURV_TRQ_FADEC TRQ FADEC validity checking FADEC 1 when VEMD
lane “L” -- or -- FADEC 2

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
when VEMD Lane “R”
62 SURV_N1_FADEC N1 FADEC validity checking FADEC 1 when VEMD
lane “L” -- or -- FADEC 2
when VEMD Lane “R”
63 SURV_CLP_FADEC CLP FADEC validity checking FADEC 1 when VEMD
lane “L” -- or -- FADEC 2
when VEMD Lane “R”
64 SURV_N2_FADEC N2 FADEC validity checking FADEC 1 when VEMD
lane “L” -- or -- FADEC 2
when VEMD Lane “R”
65 SURV_DOM_AV AV 1 value domain checking Wiring Bus voltage 1
VEMD
66 SURV_UNDOFF_GC GC 1 under offset checking Measurement shunt
Generator current 1 -- or
-- wiring GC Shunt 1
VEMD
67 SURV_DOM_GC GC 1 value domain checking Measurement shunt
Generator current 1 -- or
-- wiring GC Shunt 1
VEMD
68 SURV_DOM_EOT EOT 1 value domain checking EOT 1 sensor -- or --
wiring EOT1 sensor
VEMD
69 SURV_DOM_OAT OAT value domain checking OAT sensor -- or --
wiring OAT sensor
VEMD
72 SURV_DOM_TOT_R TOT_R value domain checking wiring TM maching
resistor box engine 1
VEMD
73 SURV_DOM_FFT FFT1 value domain checking Fuel temperature sensor
1 -- or -- wiring Fuel
temperature sensor 1
VEMD
74 SURV_DOM_FF2 FF2 value out of domain Fuel Flow sensor 2 -- or
-- wiring Fuel Flow
sensor 2 VEMD
75 SURV_DOM_NR NR value domain checking NR sensor -- or -- wiring
NR sensor VEMD
76 SURV_N1BIAS_FADEC N1 BIAS FADEC validity checking PW only: FADEC 1
77 SURV_TOTBIAS_FADEC TOT BIAS FADEC validity checking PW only: FADEC 1
Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
Table 5 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure Sources
78 SURV_TRQBIAS_FADEC TRQ BIAS FADEC validity checking PW only: FADEC 1

The following error code table is effective for All starting with software V2003
Table 6 - VEMD Error Code Table for All starting with Software V2003
Failure Code / Test Name Failure Description Possible Failure Sources

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
79 CROSS_P0_ARINC Dissimilarity check between P0 value P0 sources (ADC, FCDS,
acquired by a module and value received AFCS)
through the crosstalk
80 CROSS_T0_ARINC Dissimilarity check between OAT value T0 sources (ADC, FCDS,
acquired by a module and ARINC input AFCS)
values

The following error code table is effective for All starting with software V2002
Table 7 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure Sources
81 COMP_N1 Comparison test between N1 value FADEC 1 -- or -- N1
acquired by a module and FADEC value sensor engine 1 -- or --
wiring N1 sensor engine 1
VEMD
85 COMP_TRQ Comparison test between CAD TRQ FADEC 1 -- or -- wiring
value and FADEC value acquired by a TRQ 1 FADEC 1 PWM
module output CAD
86 COMP_TOT Comparison test between CAD TOT PW only: FADEC 1 -- or --
value and FADEC value acquired by a wiring TOT 1 FADEC 1
module PWM output CAD

The following error code table is effective for All starting with software V2003
Table 8 - VEMD Error Code Table for All starting with Software V2003
Failure Code / Test Name Failure Description Possible Failure Sources
87 SURV_DOM_P0_BUS P0 bus domain and validity check P0 sources (ADC,
FCDS, AFCS)
or
88 SURV_DOM_OAT_BUS OAT bus domain and validity check T0 sources (ADC, FCDS,
AFCS)

The following error code table is effective for All starting with software V2002
Table 9 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure Sources
97 COMP_DN1 Comparison test between DN11 -N11 FADEC 1 -- or -- FADEC
and DN12 - N12 values 2 -- or -- wiring DN1
FADEC 1 PWM output
CAD -- or -- wiring
DN1 FADEC 2 PWM
output CAD

Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
Table 9 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure Sources
105 SURV_DOM_XMSNOP XMSNOP value domain checking XMSNOP sensor -- or --
wiring XMSNOP sensor
VEMD -- or -- wiring
VEMD power supply
sensor XMSNOP
sensor

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
106 SURV_DOM_XMSNOT XMSNOT value domain checking XMSNOT sensor -- or --
wiring XMSNOT sensor
VEMD

The following error code table is effective for software V2002 and V2003
Table 10 - VEMD Error Code Table only for Software V2002 and V2003
Failure Code / Test Name Failure Description Possible Failure Sources
109 TEST_MMO Test Mast moment MM device -- or -- Wiring
VEMD Mast moment test
output MM device -- or
-- Wiring MM device
VEMD

The following error code table is effective for All starting with software V2002
Table 11 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure Sources
110 SURV_UNDOFF_MMO Mast Moment under offset checking MM device -- or -- Wiring
MM device VEMD
111 SURV_DOM_MMO Mast Moment value domain checking MM device
113 TEST_ENG_TYPE Verifies engine type configuration is TM Wiring engine type
or PW discrete VEMD

The subsequent error code table is valid for All starting with software V2012
Table 12 - VEMD error code table for All starting with software V2012
Failure Code / Test Name Failure Description Possible Failure Sources
115 SURV_VAL_IAS1 IAS1 validity IAS1 sources (ADC,
FCDS, AFCS) - or -
ARINC Bus wiring
VEMD
116 SURV_VAL_IAS2 IAS2 validity IAS2 sources (ADC,
FCDS, AFCS) - or -
ARINC Bus wiring
VEMD

The following error code table is effective for All starting with software V2002
Table 13 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure
Sources
146 SURV_DOM_TCJ TOTCJ value domain checking VEMD
Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
Table 13 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure
Sources
152 CROSS_TOT_R Dissimilarity check between TOT_R VEMD
value acquired by a module and
value received through the crosstalk
153 CROSS_FLI Dissimilarity check between FLI VEMD
value computed by a module and

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
value received through the crosstalk
173 SURV_DOM_NG N1 engine 2 value domain checking N1 sensor engine 2 -- or
-- wiring N1 sensor
engine 2 VEMD
177 SURV_UNDOFF_BC BC2 under offset checking Measurement shunt
Battery 2 current -- or --
wiring BC Shunt
VEMD
178 SURV_DOM_BC BC2 value domain checking Measurement shunt
Battery 2 current -- or --
wiring BC Shunt
VEMD
184 SURV_DOM_EOP EOP 2 value domain checking EOP 2 sensor -- or --
wiring EOP 2 VEMD
-- or -- wiring VEMD
power supply EOP 2
sensor
193 SURV_DOM_AV AV value domain checking Wiring Bus voltage 2
VEMD
193 SURV_UNDOFF_GC GC2 under offset checking Measurement shunt
Generator current 2 -- or
-- wiring GC Shunt 2
VEMD
193 SURV_DOM_GC GC2 value domain checking Measurement shunt
Generator current 2 -- or
-- wiring GC Shunt 2
VEMD
193 SURV_DOM_EOT EOT2 value domain checking EOT 2 sensor -- or --
wiring EOT2 sensor
VEMD
200 SURV_DOM_TOT_R TOT_R value domain checking wiring TM maching
resistor box engine 2
VEMD
201 SURV_DOM_FFT FFT2 value domain checking Fuel temperature sensor
2 -- or -- wiring Fuel
temperature sensor 2
VEMD
204 SURV_N1BIAS_FADEC N1 BIAS FADEC validity checking PW only: FADEC 2
205 SURV_TOTBIAS_FADEC TOT BIAS FADEC validity checking PW only: FADEC 2
206 SURV_TRQBIAS_FADEC TRQ BIAS FADEC validity checking PW only: FADEC 2
Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
Table 13 - VEMD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure
Sources
209 COMP_N1 Comparison test between N1 value FADEC 2 -- or -- N1
acquired by a module and FADEC sensor engine 2 -- or --
value wiring N1 sensor engine
2 VEMD
213 COMP_TRQ Comparison test between CAD TRQ FADEC 2 -- or -- wiring

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
value and FADEC value acquired by TRQ 2 FADEC 2 PWM
a module output CAD
214 COMP_TOT Comparison test between CAD TOT PW only: FADEC 2 -- or
value and FADEC value acquired by -- wiring TOT 2 FADEC
a module 2 PWM output CAD

B. CAD Error Code Table

NOTE
Information in the error code table are only used to help identify errors.

NOTE
The effectivities for the different software configurations (V2002, V2003 and V2005)
are given in the titles of the individual tables.

NOTE
Disregard error codes 9, 11, 27, 34, 35, 39, which can occur up to and including
software version V2002.

The following error code table is effective for All starting with software V2002
Table 14 - CAD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure
Sources
0 CHECK_DATA_CONF Consistency check between CAD CAD
part number written during ATP in
CAD software and : -
PARTNUMCHAN = C19243A* for
non NVG version, C19243B* for
NVG version N.B.: “*” replaces any
letter or number
1 TEST_CPU 68332 used external RAM test: - CAD
Write the value $5555 - Read and
compare to $5555 - Write the
value $AAAA - Read and compare
to $AAAA Computation of level C
program code checksum

Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
Table 14 - CAD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure
Sources
2 TEST_IOM 1 IOM 1 pattern registers reading CAD
test: Read the first pattern register:
$AAAA Read the second patten
register: $5555
3 TEST_ACCES_GS Reticules are sent to GSV to check CAD

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
the good running of the securities;
the test securities are: - Parity -
Serial line (0 value words sent) -
Overflow capacity (290 reticules) -
False reticule (unforeseen reticule)
- 4 Reticule/Colour overlap RAM 1
and 2
5 TEST_GSV_OPER RAM1 and 2 reticule colour test CAD
GSV failure if It GS-OK and TP6 =
1 (GS NOK) and BFXY0..3 = 1
7 TEST_IOM 2 IOM 2 pattern registers reading CAD
test: Read the first pattern register:
$AAAA Read the second patten
register: $5555
8 TEST_EEPROM_CONF_CKS Verify that the EEPROM_CONFIG CAD
computed checksum is equal to
the stored checksum
10 TEST_FREQ_IN (include Every FREQ (and PWM) can be CAD
TEST_PWM_IN) connected with the FTESTFREQ
(TPU output see IRS) by a
multiplexer before ASIC IOM.
Software puts FTESTFREQ on the
tested entry and verifies the value
given by ASIC IOM
12 TEST_ANA_IN (include Groups gain and offset on module CAD
TEST_DISCRET_IN) are computed. For each group a
comparison is done with MIN and
MAX value (refer to IRS)
13 SURV_OEITRQ_MEM engine type memorisation CAD
surveillance
14 TEST_INTERN_SUPPLY Test of ASIC IOM values : +-15 V CAD
SURVEILLANCE PWRDIS
16 TEST_IOM1_OPER_ACQ Reading of the IOM1 status CAD
acquisition
18 TEST_LUM Verify FLUM is not zero CAD
19 SURV_ENGTYP_MEM engine type memorisation CAD
surveillance
20 TEST_13V_OUT_MFQ1 Fuel tank sensors power supply CAD
are read by ASIC IOM and must be
equal at least to 13 V + / - 26 mV

Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
Table 14 - CAD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure
Sources
21 TEST_13V_OUT_MFQ2 Fuel tank sensors power supply CAD
are read by ASIC IOM and must be
equal at least to 13 V + / - 26
22 TEST_13V_OUT_SFQ1 Fuel tank sensors power supply CAD
are read by ASIC IOM and must be

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
equal at least to 13 V + / - 26
23 TEST_13V_OUT_SFQ2 Fuel tank sensors power supply CAD
are read by ASIC IOM and must be
equal at least to 13 V + / - 26
24 TEST_13V_OUT_AFQ Fuel tank sensors power supply CAD
are read by ASIC IOM and must be
equal at least to 13 V + / - 26 mV
26 TEST_COUNTER_IN The counter input signals can be CAD
connected with the FTESTPULSE
and FTESTSYNC (TPU output see
IRS) by a multiplexer before ASIC
IOM. Software puts TESTPULSE
and FTESTSYNC on the tested
entry and verifies the value given
by ASIC IOM
28 CHECK_DATA_REFA Verify that the EEPROM_SXT CAD
computed checksum is equal to
the stored checksum
30 SURV_DOM_DN1 DN1 ENG 1 domain checking TM only: FADEC 1
PWM DN1 output -- or
-- Wiring FADEC 1
CAD
31 SURV_DOM_TOT TOT ENG 1 domain checking PW only: FADEC 1
PWM TOT output -- or
-- Wiring FADEC 1
CAD
32 TEST_HEATER Check the consistency between CAD
CDE RECHAUF ON (DISINOUT7)
and heater activated (DISIN8)
33 TEST_FAN Command Fan ON (DISINOUT6) CAD
The reading of ventilation activated
(DISIN8) value after at least 300
ms. Nota: Do not perform
TEST_FAN if temperature is under
0 oC
36 TEST_EEPROM_WRITE if an EEPROM written has been CAD
requested, software verifies after
writing the write value (by reading)
37 TEST_EEPROM_BAL Verify that the EEPROM BAL CAD
computed checksum is equal to
the stored checksum

Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
Table 14 - CAD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure
Sources
38 TEST_ACCES_LUM Gcj (Corrected gain day/night) and, CAD
for NVG version, Gcn (corrected
gain NVG) are read in the serial
BAL EEPROM during power-on if
Gcj failure (Gcj greater or equal

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
than 5 or Gcj less or equal than
0.5) set Gcj to 1 for NVG version: if
Gcn failure (Gcn greater or equal
than 4) set Gcn to 1.5
40 TEST_ARINC_LOOP Connect the ARINC output to the CAD
ARINC input and check the link.
42 SURV_VEMDTALK1 An arinc 429 link failure is declared VEMD 1 Failure or
if the label 030 (Mode switched off -- or --
Management) is not received three Wiring VEMD1
times successively from channel A Crosstalk CAD
43 SURV_VEMDTALK2 An arinc 429 link failure is declared VEMD 2 Failure or
if the label 030 (Mode switched off -- or --
Management) is not received three Wiring VEMD2
times successively from channel Crosstalk CAD
Ap
44 TEST_BRT_BUTTON Check that the “BRT+” and/or CAD
“BRT-” push-buttons are not
detected depressed during more
than 30 seconds
83 CT_TRGB_CHIP_NA TRGB Chip continuity test could be CAD
not performed
84 CT_ENG_FUEL_FILT_NA ENG 1 Fuel Filter continuity test CAD
could be not performed ENG 1
85 CT_XMSN_OIL_TEMP_NA XMSN Oil Temperature continuity CAD
test could be not performed
86 CT_XMSN_OIL_FILT_NA XMSN Oil filter continuity test CAD
could be not performed
87 CT_ENG_OIL_FILT_NA ENG1 Oil filter continuity test could CAD
be not performed ENG 1
88 CT_ENG_CHIP_NA ENG 1 chip continuity test could be CAD
not performed ENG 1
89 CT_XMSN_CHIP_NA XMSN Chip continuity test could CAD
be not performed
90 SURV_DOM_BATT BATT domain checking Not applicable on
EC135
91 SURV_DOM_MFQ1 MFQ1 domain checking Main tank sensor 1 --
or -- Wiring Main tank
sensor 1 “signal”
CAD

Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
Table 14 - CAD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure
Sources
92 SURV_DOM_MFQ2 MFQ2 domain checking Main tank sensor 2 --
or -- Wiring Main tank
sensor 2 “signal”
CAD
93 SURV_DOM_SFQ1 SFQ1 domain checking Supply tank sensor 1 -

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
- or -- Wiring Supply
tank sensor 1 “signal”
CAD
94 SURV_DOM_SFQ2 SFQ2 domain checking Supply tank sensor 2 -
- or -- Wiring Supply
tank sensor 2 “signal”
CAD
95 SURV_DOM_AFQ AFQ domain checking Auxiliary tank sensor -
- or -- Wiring Auxiliary
tank sensor “signal”
CAD
96 SURV_DOM_RHCL RHCL domain value checking Rescue Winch
97 SURV_DOM_TRQ Torque ENG 1 domain checking FADEC 1 PWM TRQ
output -- or -- Wiring
FADEC 1 CAD
100 CT_TRGB_CHIP TRGB Chip continuity test failed Wiring CAD TRGB
Chip detector CAD
101 CT_ENG_FUEL_FILT ENG 1 Fuel Filter continuity test Wiring CAD
failed Engine 1 Fuel Filter
switch CAD
103 CT_XMSN_OIL_TEMP XMSN Oil Temperature continuity Wiring CAD XMSN
test failed Oil temperature switch
CAD
104 CT_XMSN_OIL_FILT XMSN Oil filter continuity test Wiring CAD XMSN
failed Oil filter switch
CAD
105 CT_ENG_OIL_FILT ENG1 Oil filter continuity test failed Wiring CAD
Engine 1 Oil filter
switch CAD
107 CT_ENG_CHIP ENG 1 chip continuity test failed Wiring CAD
Engine 1 Chip
detector CAD
109 CT_XMSN_CHIP XMSN Chip continuity test failed Wiring CAD XMSN
Chip detector CAD
110 SURV_DOM_FF1 FF1 Domain checking Fuel Flow sensor
Engine 1 -- or --
Wiring Fuel Flow
sensor Engine 1
CAD
Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12
Table 14 - CAD Error Code Table for All starting with Software V2002
Failure Code / Test Name Failure Description Possible Failure
Sources
113 TEST_ENG_TYPE Check engine type consistency Wiring of Engine Type
selection (TM or PW)
CAD
114 TEST_TANK_TYPE Check Tank type consistency Configuration file CAD
corrupted -- or -- CAD

THE DOCUMENT REFERENCE IS AVAILABLE ONLINE. PLEASE CHECK IF THE ONLINE DOCUMENTATION CORRESPONDS TO THE PRINTED VERSION
158 SURV_DOM_DN1 DN1domain checking Eng 2 TM only: FADEC 2
PWM DN1 output -- or
-- Wiring FADEC 2
CAD
159 SURV_DOM_TOT TOT domain checking Eng 2 PW only: FADEC 2
PWM TOT output -- or
-- Wiring FADEC 2
CAD
212 CT_ENG_FUEL_FILT_NA ENG 2 Fuel filter continuity test CAD
could be not performed
215 CT_ENG_OIL_FILT_NA ENG 2 Oil filter continuity test CAD
could be not performed
216 CT_ENG_CHIP_NA ENG 2 Chip continuity test could CAD
be not performed ENG 2
225 SURV_DOM_TRQ Torque ENG 2 domain checking FADEC 2 PWM TRQ
output -- or -- Wiring
FADEC 2 CAD
229 CT_ENG_FUEL_FILT ENG 2 Fuel filter continuity test Wiring CAD
failed Engine 2 Fuel Filter
switch CAD
233 CT_ENG_OIL_FILT ENG 2 Oil filter continuity test Wiring CAD
failed Engine 2 Oil filter
switch CAD
235 CT_ENG_CHIP ENG 2 Chip continuity test failed Wiring CAD
Engine 2 Chip
detector CAD

© Copyright - Airbus

Printed from ORION H135 Rev.012.00 (Update 01) SDS 31-65-00,09 (2023-03-22) - Printed by z00000079692 on 2023-07-12