You are on page 1of 5

Subject Bill of Quantities

Project Owner SUNSAT -LABORATORY


Ground floor
No Description Width Length Height No Unit Qty
1 Excavation
Clearing before the construction and after the construction and removing
1.1 19.8 16.32 1 1 M2 323.14
all the debris from the site
1.2 Excavation of footings 1.6 1.6 1.2 4 M 3
12.29
1.3 Excavation of footings 1.7 1.7 1.2 2 M3 6.94
3
1.4 Excavation of footings 1.8 1.8 1.2 2 M 7.78
3
1.5 Excavation of footings 2.1 2.1 1.2 2 M 10.58
3
1.6 Excavation of footings 2.2 2.2 1.2 4 M 23.23
3
1.7 Excavation of footings 2.3 2.3 1.2 3 M 19.04
3
1.8 Excavation of footings 2.4 2.4 1.2 2 M 13.82
1.9 Excavation of footings 2.5 2.5 1.2 1 M3 7.50
3
1.10 Excavation of footings 3.5 3.5 1.2 2 M 29.40
3
1.11 Excavation of trenches (.4m x216m x0.5) 0.4 216 0.5 1 M 43.20
Sub Total
2 Masonary Work
Rubble stone foundation in cement & sand mortar 1:4 mix (216 m x 0.4 m )
2.1 0.4 216 1.2 1 M3 103.68
at an average depth of 1.2m upto below ground level.

Rubble stone foundation in cement & sand mortar 1:4 mix (64 m x 0.4 m )
2.2 0.4 64 0.5 1 M3 12.80
at an average depth of 0.50m under the ground beam level
Sub Total
3 Back filling
Backfilling with selected sand to an average depth of 0.90 and compacting
3.1 1 237 0.9 1 M3 213.30
to a desired compacting level

Backfilling with selected sand of crushed dusts to an average depth of 1.0m


3.2 m and compacting to a desired compacting level with no more thanl 20cm 1 116.62 1 1 M3 116.62
each layer- under the ground beam

Sub Total
4 Lean and Concrete Works
4.1 Lean concrete 10cm thick with (1:2:4) mix for levelling the footing beds 1.6 1.6 0.1 4 M3 1.02

4.2 Lean concrete 10cm thick with (1:2:4) mix for levelling the footing beds 1.7 1.7 0.1 2 M3 0.58

4.3 Lean concrete 10cm thick with (1:2:4) mix for levelling the footing beds 1.8 1.8 0.1 2 M3 0.65

4.4 Lean concrete 10cm thick with (1:2:4) mix for levelling the footing beds 2.1 2.1 0.1 2 M3 0.88

4.5 Lean concrete 10cm thick with (1:2:4) mix for levelling the footing beds 2.2 2.2 0.1 4 M3 1.94

4.6 Lean concrete 10cm thick with (1:2:4) mix for levelling the footing beds 2.3 2.3 0.1 3 M3 1.59

4.7 Lean concrete 10cm thick with (1:2:4) mix for levelling the footing beds 2.4 2.4 0.1 2 M3 1.15

4.8 Lean concrete 10cm thick with (1:2:4) mix for levelling the footing beds 2.5 2.5 0.1 1 M3 0.63

4.9 Lean concrete 10cm thick with (1:2:4) mix for levelling the footing beds 3.5 3.5 0.1 2 M3 2.45
Lean concrete 10cm thick with (1:2:4) mix for levelling and smoothening
4.10 1 237 0.1 1 M3 23.70
of the floor over the compacted sand
Casting RCC footings (1.4m x 14m) with (1:1.5:3) an average depth of .40
4.11 1.4 1.4 0.4 4 M3 3.14
m
Casting RCC footings (1.5m x 1.5m) with (1:1.5:3) an average depth of .40
4.12 1.5 1.5 0.4 2 M3 1.80
m
Casting RCC footings (1.6m x 1.6m) with (1:1.5:3) an average depth of .40
4.13 1.6 1.6 0.4 2 M3 2.05
m
Casting RCC footings (1.9m x 1.9m) with (1:1.5:3) an average depth of .40
4.14 1.9 1.9 0.4 2 M3 2.89
m
4.15 Casting RCC footings (2m x 2m) with (1:1.5:3) an average depth of .40 m 2 2.0 0.4 4 M3 6.40
Casting RCC footings (2.1m x 2.1m) with (1:1.5:3) an average depth of .40
4.16 2.1 2.1 0.4 2 M3 3.53
m
Casting RCC footings (2.1m x 2.1m) with (1:1.5:3) an average depth of .50
4.17 2.1 2.1 0.5 1 M3 2.21
m
Casting RCC footings (2.2m x 2.2m) with (1:1.5:3) an average depth
4.18 2.2 2.2 0.5 1 M3 2.42
of .50m
Casting RCC footings (2.2m x 2.2m) with (1:1.5:3) an average depth
4.19 2.2 2.2 0.4 1 M3 1.94
of .40m
Casting RCC footings (2.3m x 2.3m) with (1:1.5:3) an average depth
4.20 2.3 2.3 0.4 1 M3 2.12
of .40m
Casting RCC footings (3.5m x 3.5m) with (1:1.5:3) an average depth
4.21 3.3 3.3 0.5 2 M3 10.89
of .50m
Casting RCC foundation columns(0.25m x 0.60m) with (1:1.5:3) depth of
4.22 0.25 0.6 2 19 M3 5.70
2.0m.
Casting RCC foundation columns(0.25m x 0.50m) with (1:1.5:3) depth of
4.23 0.25 0.5 2 5 M3 1.25
2.0m.
Casting RCC foundation columns(0.25m x 0.40m) with (1:1.5:3) depth of
4.24 0.25 0.4 2 4 M3 0.80
2.0m.
Casting RCC foundation columns(0.25m x 1.05m) with (1:1.5:3) depth of
4.25 0.25 1.05 1.8 2 M3 0.95
1.80m.
Casting RCC (1:2:4 mix) Tie beam (216m x 0.4m x 0.2m) . See the
4.26 0.4 216.0 0.2 1 M3 17.28
structural design

4.27 Casting RCC columns (1:1.5:3 mix) (0.25 m x 0.40m x 4.0m depth ) 0.25 0.4 4 4 M3 1.60

4.28 Casting RCC columns (1:1.5:3 mix) (0.25 m x 0.50m x 4.0m depth ) 0.25 0.5 4 5 M3 2.50

4.29 Casting RCC columns (1:1.5:3 mix) (0.25 m x 0.60m x 4.0m depth ) 0.25 0.6 4 19 M3 11.40

4.30 Casting RCC columns (1:1.5:3 mix) (0.25 m x 1.05m x 4.0m depth ) 0.25 1.05 4 2 M5 2.10

Cast RCC (1:1.5:3 mix) Lintel beams 4Y12 re-bars & R8 links @ 200 mm
4.31 0.2 173 0.2 1 M3 6.92
c/c.
Cast RCC (1:1.5:3) mix) beams of Slab (0.60x186x0.25). See the
4.32 0.44 186 0.25 1 M3 20.46
structural design
4.33 Cast RCC (1:1.5:3) mix) Slab of 160 mm thick 1 296 0.16 1 M3 47.36
4.34 Cast RCC (1:1.5:3) mix) Staircase 1 5 1 1 M3 5.00
Sub Total
5 Walls

Supply and built hollow cement block walls type 400×200×200 mm with
5.1 mixture of 1:4 cement & sand mortar and fill the space between the 1 172 3.4 1 M2 524.80
blocks(Jaajuurka Horseed)

Sub Total
6 Doors & Windows
Supply and install internal Turkish wooden door size (900x2100)mm.
6.1 1 1 1 10 PCS 10.00
With all required sealants, locks, specifications and engineer's instructions

Supply and install internal Turkish wooden door size (800x2100)mm.


6.2 1 1 1 4 PCS 4.00
With all required sealants, locks, specifications and engineer's instructions

Supply and install alumunium entrance double door double swing with
6.3 (2800x6000)mm. With all required sealants, locks, specifications and 2.8 1 6 1 PCS 16.80
engineer's instructions
Supply and install aluminium sliding door double swing with Decorative
6.4 glass(1600x1500)mm. With all required sealants, locks, specifications and 1.6 1 1.5 8 PCS 19.20
engineer's instructions
Supply and install aluminium sliding door double swing with Decorative
6.5 glass(1600x2400)mm. With all required sealants, locks, specifications and 1.6 1 2.4 2 PCS 7.68
engineer's instructions
Providing & Fixing aluminium double glazed sliding window with 10mm
6.6 1 1 1.5 2 M2 3.00
thick and size of (100x1500mm) inclduing safety grills

Providing & Fixing aluminium double glazed sliding window with 10mm
6.7 0.5 1 5.1 6 M2 15.30
thick and size of (500x5100mm) inclduing safety grills

Providing & Fixing aluminium double glazed sliding window with 10mm
6.8 1.5 1 8 1 M2 12.00
thick and size of (1500x8000mm) inclduing safety grills

Providing & Fixing aluminium double glazed sliding window with10mm


6.9 0.7 0.7 1 4 M2 1.96
thick and size of (700mmx700mm) inclduing safety grills
Sub Total
7.0 Tiling and Handrailing
600mmx600mm Main Floor ceremic tiles inclduing Rooms,Corridor,
7.1 1 350.82 1.1 1 M2 385.90
toilets and Verandah tiles
7.2 300mmx600mm wet areas Wall ceramictiles (Toilets) 1 41.2 4 1 M 2
164.80
supply and install stainless steel handrails for staircases including all
7.3 1 16 1 1 LM 16.00
accessories required to complete the job
Sub Total
8 Plastering
8.1 Plastering on walls surfaces with 15mm plaster thickness 1 172 4 2 M2 1256.00
8.2 Plastering on walls surfaces with 15mm plaster thickness 1 76 1 1 M2 76.00
Sub Total
9 Painting
Apply three coats of approved type plastic emulsion paint to internal wall,
9.1 1 268.4 4 1 M2 953.60
beams and columns.
9.2 Painting for the slab 1 296 1 1 M2 296.00
Apply one coat of Graphic paint and distemper for the exterior
9.3 1 76 5 1 M 2
320.00
walls(Rinji Xabashi iyo distemper)
Sub Total
10 Plumbing
10.1 Water supply (Fresh water system ) . . . . LS 1.00
10.2 Sanitary works ( 4WC,4washing basin and sewage system) . . . . LS 4.00
Sub Total
11 Electrical

All wires should be the best quality like Saudi arabian wires. All wire
Note
dimensions should be 6mm, 4mm and 2.5mm for the whole building.

Supply and Electrical Installations including all light fittings, Power and
11.10 data outlets, conduits,cables and Mains connection (GF.T 3% Excluding . . . . LS
septic tank)
Sub Total

13 Septic tank

Concrete septic tank size 3000Lx3500Wx4800mm Deep. The septic tank


13.1 must be lower the ground by minimum 300mm and build to resist cars load 3 3.5 4.8 1 M3 50.40
and septic tank to have 200mm thick slab

Sub Total

Grand Total of Ground floor

First floor
1 Concrete Works

1.1 Casting RCC columns (1:1.5:3 mix) (0.25 m x 0.40m x 3.6m depth ) 0.25 0.4 3.6 4 M3 1.44

1.2 Casting RCC columns (1:1.5:3 mix) (0.25 m x 0.50m x 3.60m depth ) 0.25 0.5 3.6 5 M3 2.25

1.3 Casting RCC columns (1:1.5:3 mix) (0.25 m x 0.60m x 3.6m depth ) 0.25 0.6 3.6 19 M3 10.26

1.4 Casting RCC columns (1:1.5:3 mix) (0.25 m x 1.05m x 3.6m depth ) 0.25 1.05 3.6 2 M5 1.89
Cast RCC (1:1.5:3 mix) Lintel beams 4Y12 re-bars & R8 links @ 200 mm
1.5 0.2 173 0.2 1 M3 6.92
c/c.
Cast RCC (1:1.5:3) mix) beams of Slab (0.60x191.3x0.25). See the
1.6 0.44 191.4 0.25 1 M3 21.05
structural design
1.7 Cast RCC (1:1.5:3) mix) Slab of 160 mm thick 1 296 0.16 1 M3 47.36
3
1.8 Cast RCC (1:1.5:3) mix) Staircase 1 5 1 1 M 5.00
Sub Total
5 Walls

Supply and built hollow cement block walls type 400×200×200 mm with
5.1 mixture of 1:4 cement & sand mortar and fill the space between the 1 172 3 1 M2 470
blocks(Jaajuurka Horseed)

Sub Total
6 Doors & Windows
Supply and install internal Turkish wooden door size (900x2100)mm.
6.1 1 1 1 10 PCS 10.00
With all required sealants, locks, specifications and engineer's instructions

Supply and install internal Turkish wooden door size (800x2100)mm.


6.2 1 1 1 4 PCS 4.00
With all required sealants, locks, specifications and engineer's instructions

Supply and install aluminium sliding door double swing with Decorative
6.3 glass(1600x1500)mm. With all required sealants, locks, specifications and 1.6 1 1.5 8 PCS 19.20
engineer's instructions
Supply and install aluminium sliding door double swing with Decorative
6.4 glass(1600x2400)mm. With all required sealants, locks, specifications and 1.6 1 2.4 2 PCS 7.68
engineer's instructions

Providing & Fixing aluminium double glazed sliding window with 10mm
6.5 1 1 1.5 2 M2 3.00
thick and size of (100x1500mm) inclduing safety grills

Providing & Fixing aluminium double glazed sliding window with 10mm
6.6 0.7 0.7 1 4 M2 1.96
thick and size of (700mmx700mm) inclduing safety grills
Sub Total
7 Tiling and Handrailing
600mmx600mm Main Floor ceremic tiles inclduing Rooms,Corridor,
7.1 1 309.1 1.1 1 M2 340.01
toilets and Verandah tiles
7.2 300mmx600mm wet areas Wall ceramictiles (Toilets) 1 41.2 4 1 M 2
164.80
supply and install stainless steel handrails for staircases including all
7.3 1 16 1 1 LM 16.00
accessories required to complete the job
Sub Total
8 Plastering
8.1 Plastering on walls surfaces with 15mm plaster thickness 1 173 3.6 2 M2 1163.60
Sub Total
9 Painting
Apply three coats of approved type plastic emulsion paint to internal wall,
9.1 1 268.4 3.6 1 M2 884.24
beams and columns.

9.2 Apply one coat of Graphic paint for the exterior walls(Rinji Xabashi) 1 76 3.6 1 M2 227.60

9.3 Painting for the slab 1 296 1 1 M2 296.00


Sub Total
10 Plumbing
10.1 Water supply (Fresh water system ) . . . . LS 1.00
10.2 Sanitary works ( 4WC,4washing basin and sewage system) . . . . LS 4.00
Sub Total
11 Electrical
All wires should be the best quality like Saudi arabian wires. All wire
Note
dimensions should be 6mm, 4mm and 2.5mm for the whole building.

Supply and Electrical Installations including all light fittings, Power and
11.10 . . . . LS
data outlets, conduits,cables and Mains connection (GF.T 3%)
Sub Total

Total of first floor


Second=Stair cover, Roof screed, Parapet Wall and Sktligth Glass
Stair cover
12 Check section and elevation drawings Note
The price rates included its construction, plastering, white washing and
Note
distempering and painting

Supply and build hollow cement blocks 40x15x20cm thick for the stair
12.1 1 19 3 1 M2 55.11
cover walls with cement & sand mortar 1:4 mix.

Supply and make external and internal plastering 15 mm thick for all
walls, colmns and Beams with tow faces, mix(1:3) cement and sand
12.2 1 19 3 2 M2 114.00
according to specifications and superver's instructions.( space openings
deducted)
Apply three coats of approved type plastic emulsion paint to internal wall,
1 19 3 1 M2 54.00
beams and columns.
12.3 Apply one coat of Ethiopian paint for the exterior walls 1 19 3 1 M2 57.00
Cast RCC (1:2:4 mix) Lintel beams Y12 re-bars & R8 links @ 200 mm
12.4 0.2 19 0.2 1 M3 0.76
c/c.
12.5 Corrugated Iron Sheet Roof, nr 28 including woods 1 22 1.3 1 M2 28.60

12.6 Suspension ceiling 600mm x600 mm 1 22 1 1 2 22.00


M
12.7 non-slippery ceramic tiles 600mm x600 mm 1 22 1.1 1 2 24.20
M

12.8 Steel door with complete with frames, hinges and locks(0.90m x 2.1m) 1 1 1 1 PCS 1.00

13 Roof Screed and parapet wall


Supply and cast foam concrete with fine aggregates for roof screeding
13.1 1 302 1 1 M2 302.00
+asphalt+damp proof membrane

Supply and build hollow cement blocks 40x20x15cm thick for the parapet
13.2 wall with cement & sand mortar 1:4 mix.including blocks construction. 1 74 1.2 1 M2 88.80
Plastering, painting both interior and exterior

14 Skylight
14.1 supply and install skyligth with its all accessories 1 15.8 1.05 1 M2 16.59
Sub Total

GRAND TOTAL

M-metre
General NoNo- numbers
M3-cubic metre
M2-square metre
Lm- linear metre
Mm-milimetre
LS- Lump Sum
PCS- pieces
QUANTITY SURVEYOR BY:
CHECKED BY:

You might also like