K
100% CONSTRUCTION DOCUMENTS
PERMIT SET
ICE RINK
GENERAL CONSULTANT:
ARCHITECT: JIM MALAND
D MANAGER: PROJECT MANAGER
MICHAEL SHULL
PROJECT MANAGER
LAWRENCE SCARPA, F.A.I.A.
PRINCIPAL IN CHARGE CIVIL ENGINEER:
PROJECT ELEF STAVRIDI AUTUMN WAGGONER
MANAGEMENT: PROJECT MANAGER PROJECT MANAGER
PRINCIPAL
A HONGJOO KIM
A0.00
REVISION DATES
PRINCIPAL
CONTRACTIBILITY
REVIEW:
NOT TO SCALE - -
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
PROJECT DESCRIPTION & DATA SYMBOLS SHEET INDEX ENGINEERING
ARCHITECTURAL A8.00 WALL TYPES
A8.01 WALL DETAILS
K Sheet Number Sheet Title
X ROOM NAME & A8.02 CEILING DETAILS
X NUMBER A0.00 COVER SHEET
A GRID
100 A8.10 FLOOR DETAILS
PROGRAM WILL BE DEVELOPED UNDER A SINGLE STORY MEMBRANE STRUCTURE AND A CMU STRUCTURE. A0.01A SHEET INDEX, PROJECT DESCR. & SYMBOLS
A8.20 ROOF DETAILS
000.0 DOOR NUMBER A0.01B SHEET INDEX
THE NORTH LOT WILL INCLUDE AN OUTDOOR SKATE PARK, LANDSCAPE AREA, FIRE LANE, 2 PARKING SPACES AND A ZONE FOR ELECTRICAL EQUIPMENT TO SERVE THE ICE RINK BUILDING. THIS LOT
WILL BE FENCED ALL AROUND WITH GATES ON THE NORTH AND SOUTH SIDE TO ALLOW ACCESS TO FIRE DEPT. VISITORS AND USERS OF THE ICE RINK BUILDING WILL BE COMING IN FROM SHERMAN A8.21 ROOF DETAILS
1 ELEVATION 000.A WINDOW NUMBER A0.02 3D VIEWS
WAY VIA THE NORTH LOT. MARKER A8.30 SITE DETAILS
A4.00 SRVI SURVEY
THE TWO LOTS AT 18210 SHERMAN WAY, ARE DESIGNATED AS [Q] C2-1L-CDO AND [Q] P-1L-CDO. HOWEVER THEY HAVE BEEN ACQUIRED BY THE DEPARTMENT OF RECREATION AND PARKS, CITY OF LA A8.31 SITE DETAILS
S SMOKE DETECTOR SRVII SURVEY
AND WILL BE RE-ZONED AND RE-DESIGNATED TO OPEN SPACE (SEE A0.31)
A8.32 SITE DETAILS
THE PROJECT IS LOCATED IN COUNCIL DISTRICT 3, BOB BLUMENFIELD ELEVATION SRVIII SURVEY
FE FIRE EXTINGUISHER A8.33 SITE DETAILS
BULLET
J THE PROJECT IS FUNDED BY PROPOSITION K- L.A. FOR KIDS PROGRAM BALLOT MEASURE AND OTHER SOURCES. A0.09 LOT LINE ADJUSTMENT
A8.34
CEILING MOUNTED SITE DETAILS
THE ICE RINK BUILDING IS APPROXIMATELY 28,235 GROSS SF AND WILL BE 'NFPA 13' FULLY AUTOMATIC SPRINKLERED. EXIT SIGNAGE A0.10 GENERAL NOTES
A8.35 SITE DETAILS
SUSTAINABILITY: THE PROJECT SHALL OBTAIN LEED SILVER RATING MINIMUM FROM THE USGBC. WALL MOUNTED A0.11 GENERAL NOTES
1 SECTION A8.40 SITE DETAILS
SEE SHEET A0.30 FOR CODE ANALYSIS AND MORE INFORMATION. MARKER EXIT SIGNAGE A0.12 GREEN BUILDING FORMS
A5.00 CIVIL 10/31/2023
SITE IS NOT IN A 'METHANE ZONE.' WALL MOUNTED A0.13 GREEN BUILDING FORMS
MOTION SENSOR SHEET No. SHEET TITLE
NOTES: A0.14 GREEN BUILDING FORMS
A1 WALL TYPE CEILING MOUNTED C100 GENERAL NOTES
DEFERRED SUBMITTALS ARE LISTED ON SHT. A0.30. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN, ENGINEERING AND PERMITTING OF ALL DEFERRED SUBMITTALS. PROVIDE ARCHITECT WITH A A0.15 GREEN BUILDING NOTES
MOTION SENSOR GENERAL NOTES
C101
MIN. 3 WEEKS REVIEW TIME PRIOR TO SUBMITTING FOR PLAN CHECK. A0.16 GREEN BUILDING NOTES
A SECURITY CAMERA DEMOLITION PLAN
CD100
THE CITY OF LA IS IN THE PROCESS OF ACQUIRING A 25'-0" X 265'-0" PIECE OF LAND TO EXPAND THE SOUTH LOT ON THE WEST. THE LAND ACQUISITION IS NOT YET COMPLETED AND NOT
I REFLECTED ON SURVEY HEREIN, BUT IT IS TAKEN INTO CONSIDERATION FOR THE PROPOSED ICE RINK DESIGN. SECURITY GATED
A0.17 GREEN BUILDING NOTES
C200 SITE CONTROL PLAN
INTERIOR
BUREAU OF ENGINEERING
SECURITY GATE
C301 GRADING SECTION
ALARM KEYPAD A0.22 ACCESSIBILITY NOTES
THE WORK DESCRIBED IN THESE DRAWINGS AND SPECIFICATIONS, IS TO BE PERFORMED BY TWO PRIME CONTRACTORS AS DESCRIBED BELOW: C C302 GRADING SECTION
ALARMED DOOR/ A0.23 ACCESSIBILITY DETAILS
i. SHELL & CORE (S&C) SCOPE TO INCLUDE BUILDING AND LIFE SAFETY, MEP, HEATING AND VENTILATION SYSTEMS AND INFRASTRUCTURE AS WELL AS DISABLED ACCESS COMPLIANCE. S&C
1 SECURITY GATE C303 OVER EXCAVATION PLAN
SCOPE ALSO INCLUDES SITE WORK, GRADING AND EXCAVATION, UTILITIES, LANDSCAPE AND HARDSCAPE, STRUCTURAL WORK, ALL PLUMBING FIXTURES, BATHROOM ACCESSORIES AND LIGHTING AL A0.24 ACCESSIBILITY DETAILS
DETAIL
AS NOTED. A9.10 C400 UTILITY PLAN
MARKER A0.25 ACCESSIBILITY DETAILS
FD FLOOR DRAIN (FD)
ii. FACILITY FURNISHING AND EQUIPMENT (FF&E) SCOPE SHALL INCLUDE ALL RELATED ICE EQUIPMENT, ICE RINK FLOOR AND RELATED SUB FLOOR ICE RINK PIPING, DEHUMIDIFIER EQUIPMENT, C401 STORMDRAIN PROFILES
SCOREBOARD AND SOUND SYSTEMS, SPECIALTY LIGHTING, NETTING, ALL BUILDING FURNISHING INCLUDING: BENCHES, BLEACHERS, SCOREBOARD, SKATE RACKS, DESKS, SKATE SHARPENER, A0.26 ACCESSIBILITY DETAILS
AD
HORIZONTAL CONTROL:
SEE EACH DISCIPLINE'S DRAWINGS FOR FURTHER NOTES AND CLARIFICATION ON THE SCOPE OF WORK. DEMOLITION SCHEDULE MARKER C601 EROSION CONTROL DETAILS
# A0.35 SOILS REPORT APPROVAL LETTER
NOTE MARKER
VERTICAL CONTROL:
PER TOS No 57, THE PROJECT ORIGINALLY INCLUDED TWO MORE LOTS AT 18132 SHERMAN WAY RESEDA CA 91335, TO BE USED AS ON-GRADE PARKING LOTS. DUE TO LIMITED BUDGET THE CITY OF MECHANICAL CEILING A0.36 STRUCTURAL
MODIFICATON
G LA HAS DECIDED TO MINIMIZE THE WORK ONLY ON THE (E) SOUTH LOT TO INCLUDE THE FOLLOWING : REMOVAL OF ALL WEEDS, PATCH, SLURRY AND RE-STRIPING OF THE (E) ASPHALT LOT. THIS 12.01 KEYNOTE GRILLE, SEE MECH.
SHEET No. SHEET TITLE
WORK SHALL BE PERFORMED BY THE S&C CONTRACTOR. DWGS. A0.40 OCCUPANCY DIAGRAM
SHEET TITLE:
MARKER
ADDRESS:
PROJECT:
A0.41 EGRESS EXITING DIAGRAM & FIRE LANE S0.01 GENERAL NOTES
A0.42 FIRE RATED WALL & EXIT ACCESS TRAVEL S0.02 GENERAL NOTES
ABBREVIATIONS TUB/SHOWER ROLL-IN
SHOWER A0.43 ALLOWABLE OPENINGS S1.01 TYPICAL DETAILS
A0.50 ACCESSIBLE PATH OF TRAVEL S1.02 TYPICAL DETAILS
BY:
ABS ABSOLUTE MOD MODULE SP STAND PIPE FLOOR A0.90 (E) SITE PHOTOS S1.03 TYPICAL DETAILS
CLEARANCES HB HOSE BIBB A1.00 SITE PLAN S1.11 TYPICAL DETAILS
DATE:
CIP NO.
ACC ACCESSIBLE F FIXED MTD MOUNTED SPECS SPECIFICATIONS SHOWN DOTTED
ADJ ADJACENT FE FIRE EXTINGUISHER MTL METAL S.S. STAINLESS STEEL A1.01 SITE LIGHTING PLAN S1.12 TYPICAL DETAILS
F AFF ABOVE FINISH FLOOR FF FINISHED FLOOR STL STEEL A1.10 FLOOR PLAN S1.21 TYPICAL DETAILS
ALUM ALUMINUM FF&E FACILITY FURNISHING & EQUIPMENT N/A NOT APPLICABLE STOR STORAGE A1.10A SLAB PLAN S1.22 TYPICAL DETAILS
@ AT FH FIRE HYDRANT NIC NOT IN (SHELL & CORE) CONTRACT STRUC A1.11 FINISH FLOOR PLAN TYPICAL DETAILS
T STRUCTURE
S1.31
FIN FINISH NO NUMBER A1.12 REFLECTED CEILING PLAN
BLDG BUILDING FLR FLOOR N NORTH
STRUC
T'L STRUCTURAL
PLAN LEGEND S1.32 TYPICAL DETAILS
A1.13 SPECIALTY LIGHTING & EQUIPMENT RCP (FF&E) S1.41 TYPICAL DETAILS
BLKG BLOCKING FLRG FLOORING (N) NEW SUSP SUSPENDED A1.20 ROOF PLAN S1.51 STANDARD QUALITY ASSURANCE PLAN
BM BEAM FLUOR FLUORESCENT NR NON RATED
1-HR RATED CMU WALL A2.00 ELEVATIONS S1.52 STANDARD QUALITY ASSURANCE PLAN
B.O. BOTTOM OF F.O.PLY FACE OF PLYWOOD TEMP TEMPERED
A2.01 ELEVATIONS S1.53 STANDARD QUALITY ASSURANCE PLAN
E BTWN BETWEEN F.O.C. FACE OF CONCRETE OAE OR APPROVED EQUAL THK THICK
CMU WALL. FIN. PER SPECS. SEE PLANS AND DETAILS FOR MORE INFO. A3.00 SECTIONS
S2.01 FIRST FLOOR FOUNDATION PLAN
BUR BUILT UP ROOF F.O.F. FACE OF FINISH OC ON CENTER THRU THROUGH
A3.01 SECTIONS MEMBRANE ROOF FRAMING PLAN
F.O.S. FACE OF STUD OWNER FURNISHED/CONTRACTOR T.O. TOP OF S2.02
OFCI INSTALL MEMBRANE STRUCTURE A3.02 SECTIONS MEMBRANE FRAMING ELEVATIONS
CEM CEMENT FRMG FRAMING T.O.S TOP OF SLAB S3.01
REVISIONS:
OPP OPPOSITE A3.10 ENLARGED SECTIONS
CFCI CONTRACTOR FURNISHED / INSTALLED FSR FLAME SPREAD RATING TYP TYPICAL S4.01 SECTION & DETAILS
OPER OPERABLE NON-RATED STUD WALL. PAINT PER SPECS. SEE PLANS AND DETAILS A3.11 ENLARGED SECTIONS
CJ CONTROL JOINT FURR FURRING FOR MORE INFO. S4.02 SECTION & DETAILS
INDEX NO.
UFAS UNIFORM ACCESSIBILITY STANDARDS
A3.12 ENLARGED SECTIONS
CL CENTER LINE S4.03 SECTION & DETAILS
PIC POURED-IN-PLACE CONCRETE 1-HR RATED STUD WALL. PAINT PER SPECS. SEE PLANS AND DETAILS
NO.
CLNG CEILING GA GAUGE UNO UNLESS NOTED OTHERWISE A3.13 ENLARGED SECTIONS
FOR MORE INFO. S4.04 SECTION & DETAILS
PL PROPERTY LINE
CLR CLEAR GALV GALVANIZED URNL URINAL A4.00 ENLARGED PLAN
S4.05 SECTION & DETAILS
PLAS PLASTER
D CMU CONCRETE MASONRY UNIT GEO GEOTECHNICAL A4.01 ENLARGED RCP
LANDSCAPE
PLAS
CITY ENGINEER
PLANTED AREA
DATE:
COL COLUMN GI GALVANIZED IRON LAM PLASTIC LAMINATE VER VERIFY A4.10 ENLARGED PLAN
L0.00 COVER SHEET
CONC CONCRETE GLAZ GLAZING PLY PLYWOOD VIF VERIFY IN FIELD A4.11 ENLARGED RCP
L0.01 CONSTRUCTION SCHEDULE AND NOTES
CONST CONSTRUCTION GYP BD GYPSUM BOARD PN PLAN NORTH VNR VENEER A4.20 ENLARGED PLAN
L1.00 LANDSCAPE OVERALL PLAN
CONT'S CONTINUOUS PNL PANEL A4.21 ENLARGED RCP
L1.01 LANDSCAPE ENLARGEMENT PLAN
CT CERAMIC TILE HB HOSE BIBB POT PATH OF TRAVEL W/ WITH A4.30 ENLARGED PLAN
W/D WASHER / DRYER L1.02 LANDSCAPE DIMENSION PLAN
HC HOLLOW CORE PP POWER POLE A4.31 ENLARGED RCP
D/B DESIGN BUILD HM HOLLOW METAL PR PAIR W/O WITHOUT L1.10 LANDSCAPE SECTIONS & ELEVATIONS
A4.40 ENLARGED PLANS
DBL DOUBLE HR HOUR PT POINT WD WOOD L1.20 LANDSCAPE DETAILS
C D.G. DECOMPOSED GRANITE HT HEIGHT PTD PAINTED WINDOW
A4.41 ENLARGED RCP
L1.21 LANDSCAPE DETAILS
WNDW
A4.50 ENLARGED PLAN
DESIGN GROUP
DIA DIAMETER HW HOT WATER WM WATER METER L2.01 LANDSCAPE HYDROZONE PLAN
A5.00 METAL STUD DETAILS
DIM DIMENSION RAD RADIUS WP WATERPROOFING L3.00 IRRIGATION NOTES
A5.01 METAL STUD DETAILS
DN DOWN INSUL INSULATION / INSULATED REF REFER TO IRRIGATION PLAN
WR WATER RESISTANT L3.01
A6.00 DOOR & WINDOW SCHEDULE
DR DOOR INT INTERIOR REFR REFRIGERATOR
L3.10 IRRIGATION DETAILS
A6.01 DOOR TYPES
DS DOWNSPOUT RES RESISTANT
L3.11 IRRIGATION DETAILS
RESIL RESILIENT
A6.02 WINDOW TYPES
DETL DETAIL JAN JANITOR
L4.00 PLANTING SCHEDULE & NOTES
APPROVED BY:
DESIGNED BY:
CHECKED BY:
(E) EXISTING RM ROOM A6.13 GATEWAY DETAILS
DRAWN BY:
ENGINEER:
EA EACH LAV LAVATORY RO ROUGH OPENING A6.14 GATEWAY DETAILS SHEET INDEX CONTINUES ON A0.01.B
EJ EXPANSION JOINT LDSC LANDSCAPE A6.20 DOOR DETAILS
EL LV LOW VOLTAGE S&C SHELL & CORE A7.00 SCHEDULES (SHELL & CORE)
(ELEV.) ELEVATION
LOC LOCATION SCHED SCHEDULE A7.00A SCHEDULES (FF&E) WORK ORDER NO.
ELEC ELECTRICAL
SCRN SCREEN
ENL
A7.01 FINISH DETAILS E170121B
SCW SOLID CORE WOOD
(DESIGN STAGE ONLY)
MAX MAXIMUM
A7.10 INTERIOR ELEVATIONS
A EQ EQUAL / EQUAL TO
MECH MECHANICAL SD STORM DRAIN
SHEET NAME
A7.11 INTERIOR ELEVATIONS
REVISION DATES
EQMT EQUIPMENT
MEMB MEMBRANE SECT SECTION
EVCS
EXP
ELECTRIC VEHICLE CHARGING STATION
EXPANSION
MDF
MANUF
MEDIUM DENSITY FIBERBOARD
MANUFACTURER
SHT
SHWR
SHEET
SHOWER
A7.12
A7.13
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS A0.01A
X X
SHEET OF SHEETS
A7.14 INTERIOR ELEVATIONS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A001A_24X36.DWG 12/7/2021 1:32 PM
C501 MISC. DETAILS
C502 MISC. DETAILS
C503 SUMP PUMP DETAIL & SOILS APPROVAL LETTER
1 2 3 4 5 6 7 8 9 10 11 12 13 14 C504 15
SUMP PUMP 2 DETAIL 16
C600 SITE CONTROL PLAN
SHEET
C601 INDEX
EROSION CON'T
CONTROL
ENGINEERING
ELECTRICAL
E-01 ABBREVIATIONS & GENERAL NOTES
K E-02 LEGEND
SHEET INDEX
EL-13 LIGHTING CATALOGUE CUTS
HORIZONTAL CONTROL:
EL-16 LIGHTING CATALOGUE CUTS
VERTICAL CONTROL:
MECHANICAL
G M-01 NOTES & LEGEND
SHEET TITLE:
ADDRESS:
PROJECT:
M-02 HVAC LAYOUT PLAN
DATE:
CIP NO.
M-08 MECHANICAL SYSTEM FORMS
F M-09 OUTDOOR HEAT PUMP & FAN CUT SHEET
PLUMBING
E P-01 GENERAL NOTES & ABBREVIATION
REVISIONS:
P-04 PLUMBING ROOF PLAN
INDEX NO.
P-06 PIPE SUPPORT DETAILS
NO.
P-07 PIPING DETAIL
CITY ENGINEER
DATE:
P-10 WATER SUPPLY FIXTURE COUNT
REFRIGERANT
R0.01 RINK COVER SHEET
DESIGN GROUP
R1.05 RINK SUBSOIL & SNOWMELT HEATING PLAN
APPROVED BY:
DESIGNED BY:
FIRE PROTECTION
CHECKED BY:
DRAWN BY:
ENGINEER:
FP-01 GENERAL NOTES & SINGLE LINE DIAGRAM
E170121B
(DESIGN STAGE ONLY)
A SHEET NAME
REVISION DATES
A0.01B
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A001B_24X36.DWG 12/7/2021 1:32 PM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
10/31/2023
3D VIEWS
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G
SHEET TITLE:
ADDRESS:
PROJECT:
DEPARTMENT OF PUBLIC WORKS
BY:
DATE:
CIP NO.
F
05 02
REVISIONS:
INDEX NO.
NO.
D
CITY ENGINEER
DATE:
C
DESIGN GROUP
CITY OF LOS ANGELES
B
APPROVED BY:
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
04
WORK ORDER NO.
E170121B
NOTE: SEE SHT. A1.00 FOR ALL LOCATIONS OF THESE 3D MODEL IMAGES. THESE IMAGES ARE FOR CLARIFYING PURPOSES ONLY,
(DESIGN STAGE ONLY)
A CONTRACTOR SHALL REFER TO A2.00 & A2.01 AND OTHER SHEETS FOR TECHNICAL INFORMATION.
SHEET NAME
REVISION DATES
01 A0.02
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A002_24X36.DWG 2/4/2022 10:05 AM
SRVI
SRVII
SRVIII
REVISION DATES
(DESIGN STAGE ONLY)
G
K
D
H
A
E
F
1
1
2
2
3
3
4
4
5
5
6
6
7
7
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A009_24X36.DWG 12/3/2021 9:06 AM
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
PROJECT:
DRAWN BY:
X
APPROVED BY:
18210 SHERMAN WAY, RESEDA CA 91335
SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
GENERAL NOTES: COMMERCIAL 14. PROTECTION OF FLOORS. USE CARE TO PROTECT FLOOR SURFACES FROM DAMAGE BUILDING 19. ALL EXTERIOR DOORS SHALL BE EQUIPPED WITH A LIGHTING DEVICE CAPABLE OF
AND EQUIPMENT, INCLUDING MOBILE EQUIPMENT WITH PNEUMATIC TIRES. PROVIDING AT LEAST ONE FOOTCANDLE OF LIGHT AT THE GROUND LEVEL DURING
1. THESE DRAWINGS AND SPECIFICATIONS AND COPIES ARE LEGAL INSTRUMENTS OF 1. THERE SHALL BE NO EXPOSED PIPE CONDUITS, DUCTS, VENTS, ETC. ON EXTERIOR OF
HOURS OF DARKNESS. LIGHTING DEVICES SHALL BE PROTECTED BY VANDAL-RESISTANT
K SERVICE FOR USE BY THE OWNER AND AUTHORIZED REPRESENTATIVES ON THE 15. CONVENTIONAL DETAILS SHALL APPLY WHERE NO SPECIAL DETAILS OR SECTIONS ARE THE BUILDING OR IN DESIGNATED FINISH SPACES, UNLESS NOTED AS EXPOSED
COVERS.
DESIGNATED PROPERTY ONLY. SHOWN. THE ARCHITECT WILL FURNISH ANY CLARIFICATION DETAILS AT THE REQUEST CONSTRUCTION ON FINISH SCHEDULE.
OF THE JOB SUPERINTENDENT. ENVIRONMENTAL IMPACT REPORT
2. THE CONTRACTOR SHALL CAREFULLY INSTRUCT EACH OF THE SUBCONTRACTORS TO 2. WHERE FACTORY PRIMED ITEMS OCCUR, SUCH AS GRILLES, DIFFUSERS, METAL TRIM
BECOME THOROUGHLY FAMILIAR WITH ALL OF THE DRAWINGS AND SPECIFICATIONS 16. ALL SHOP DRAWINGS SHALL BE PREPARED AS REQUIRED AND SUBMITTED TO THE AND ACCESSORIES, ETC. PAINT TO MATCH THE ADJACENT SURFACE OR AS DIRECTED BY 1. CONTRACTOR SHALL REVIEW AND FOLLOW ALL MITIGATION MEASURES AND PROJECT
AND WHEREVER EXISTING CONDITIONS MAY HAVE A BEARING ON THE EXPEDITIOUS ARCHITECT FOR CHECKING. ALL SHOP DRAWINGS REQUIRE 15 WORKING DAYS FOR THE ARCHITECT. REFER TO SPECIFICATIONS FOR ALL OTHER ITEMS NOT INCLUDED ON CONDITIONS.
PERFORMANCE OF HIS WORK. THE SUBCONTRACTOR SHALL VISIT THE JOBSITE AND REVIEW UPON RECEIPT BY ARCHITECT. SHOP DRAWINGS FOR ALL LOW VOLTAGE WORK, FINISH SCHEDULE. THE NOTE 'GSM' REFERS TO GALVANIZED OR BONDERIZED METAL, FIRE PROTECTION
PERSONALLY INSPECT AND VERIFY THE SITE FOR COMPARISON WITH PERTINENT WHETHER UNDER THIS CONTRACT OR NOT, SHALL BE SUBMITTED FOR THE ARCHITECT'S SEE FINISH SCHEDULE AND ELEVATIONS FOR PAINT COLORS. ALL PARAPET AND WALL
SECTIONS OF SPECIFICATIONS AND DRAWINGS. NO ALLOWANCE CAN BE REVIEW. COPING AND METAL WINDOW SILLS SHALL MATCH ADJACENT WALL COLOR UNLESS 1. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING AS REQ'D BY CODE FOR
SUBSEQUENTLY MADE ON BEHALF OF THE SUBCONTRACTOR FOR ERRORS DUE TO THIS 17. SPECIFICATIONS, BOUND SEPARATELY, ARE PART OF THESE DOCUMENTS. ALL NOTED OTHERWISE. SPECIFIC USE AT EVERY 75' MAX AND AS REQUIRED BY CALIFORNIA FIRE CODE. SEE
NEGLIGENCE OF FAILING TO ACQUAINT HIMSELF WITH THE EXISTING SITE CONDITIONS. ADDENDA, CHANGE ORDER, BULLETINS AND NOTICES, IF ISSUED LATER, SHALL BE PLANS FOR LOCATION AT 'FINISHED AREAS', FOR 'UN-FINISHED AREAS' SUCH AS PARKING
3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN APPROVAL BY THE
CONSIDERED AS PART OF THE WORK. THE SPECIFICATIONS, GENERAL CONDITIONS AND GARAGES, PROVIDE PLAN FOR ARCHITECT'S REVIEW.
3. CONTRACTOR SHALL VERIFY THE DIMENSIONS OF ALL EXISTING CONDITIONS AT THE APPROVED BUILDING INSPECTOR FOR ALL CONCEALED WORK BEFORE CLOSING UP.
SITE, AND SHALL REPORT TO THE ARCHITECT IN WRITING ANY DISCREPANCIES BETWEEN ALL ISSUED ADDENDA AND CHANGE ORDERS ARE PART OF ARCHITECTURAL DRAWINGS. 2. PROVIDE AND MAINTAIN FIRE EXTINGUISHERS AS REQUIRED BY THE LOCAL FIRE
4. ALL BATHROOMS AND TOILET ROOMS SHALL BE MECHANICALLY VENTILATED PER
J ACTUAL EXISTING CONDITIONS AND THE DRAWINGS FOR THE ARCHITECT'S DECISIONS 18. THE ARCHITECT SHALL BE NOTIFIED 48 HRS. PRIOR TO ANY FINISH WORK APPLICATION. MECHANICAL CODE (MIN. 5 AIR CHANGES PER HOUR), AND CONNECTED DIRECTLY TO DEPARTMENT FIELD INSPECTOR DURING CONSTRUCTION.
AND INSTRUCTIONS BEFORE PROCEEDING WITH THE WORK AFFECTED BY SUCH THE OUTSIDE. 3. FIRE EXTINGUISHERS SHALL BE REQUIRED AND DETERMINED BY FIRE DEPARTMENT
DISCREPANCIES. IF ANY DISCREPANCY OR CONFLICT APPEARS BETWEEN THE 19. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN OVER
5. NOT USED FIELD INSPECTOR.
DRAWINGS OR SPECIFICATIONS REGARDING MATERIALS THE SITUATION SHALL BE SMALL SCALE DETAILS. DIMENSIONS ARE TO FACE OF ROUGH FRAMING UNLESS
REPORTED TO THE ARCHITECT IN WRITING AND THE ARCHITECT WILL ISSUE A OBVIOUSLY SHOWN, MARKED TO CENTERLINE OF WALL OR COLUMN, OR NOTED 4. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT ALL FIRE RATED SPACES TO
6. PROVIDE BACKING AND BLOCKING FOR ALL CABINETS, LOCKERS, TOWEL BARS, GRAB
CLARIFICATION. OTHERWISE. THE REQUIREMENTS OF THE APPLICABLE CODES AND STANDARDS. PROVIDE
BARS, DOOR STOPS, HARDWARE, ETC. TYP. EVEN IF NOT SHOWN ON DETAIL. PROVIDE 10/31/2023
APPROPRIATE FIRE RATED ENCLOSURES BEHIND RECESSED LIGHT FIXTURES WHERE
4. CONTRACTOR SHALL STUDY AND COMPARE THE CONTRACT DOCUMENTS AND SHALL AT 20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTINUOUS CLEAN-UP OF THE SITE BACKING AND BLOCKING FOR OTHER ACCESSORIES/ ITEMS SHOWN AS FUTURE OR
REQUIRED.
ONCE REPORT TO THE ARCHITECT IN WRITING ALL ERRORS, INCONSISTENCIES, OR AND OF ALL DEBRIS, WHETHER CREATED BY HIS WORK, OR BY THE FAILURE OF HIS OPTIONAL ON ALL FRAME WALLS.
OMISSIONS DISCOVERED. CONTRACTOR SHALL NOT BE LIABLE TO OWNER OR SUBCONTRACTORS TO CLEAN UP AFTER THEIR WORK. 5. OMIT.
7. ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE LESS THAN 6" ABOVE THE
ARCHITECT FOR DAMAGE RESULTING FROM ANY SUCH ERRORS, INCONSISTENCIES OR 21. THESE GENERAL NOTES SHALL APPLY EQUALLY TO THE GENERAL CONTRACTOR AND GROUND SHALL BE PRESSURE-TREATED WOOD. 6. WIDTH AND HEIGHT OF REQUIRED EXIT DOORWAYS SHALL COMPLY WITH APPLICABLE
OMISSIONS IN THE CONTRACT DOCUMENTS, BUT, IF THE CONTRACTOR PROCEEDS WITH ALL PRIME SUBCONTRACTORS ENGAGED UPON THIS PROJECT. THE WORD BUILDING CODE.
8. FIRE- BLOCKING IS REQUIRED AT MID- HEIGHT OF WALLS OVER 8'-0" HIGH.
ANY WORK SO AFFECTED WITHOUT THE WRITTEN INSTRUCTIONS FROM THE ARCHITECT, "CONTRACTOR" AS USED HEREINAFTER SHALL APPLY EQUALLY TO THE WORK OF ALL
I THE CONTRACTOR SHALL MAKE GOOD ANY RESULTING DAMAGE OR DEFECTS. THE TRADES. 9. ALL EXTERIOR OPENINGS EXPOSED TO THE WEATHER SHALL BE FLASHED IN SUCH A
7. COMMERCIAL DUMPSTERS OR CONTAINERS WITH AN INDIVIDUAL CAPACITY OF 1.5 CUBIC
YARDS OR GREATER SHALL NOT BE STORED OR PLACED WITHIN 5' OF COMBUSTIBLE
CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK AT ANY TIME WITHOUT MANNER AS TO MAKE THEM WEATHERPROOF. ALL FLASHING, COUNTER-FLASHING AND
22. THESE DRAWINGS ARE INTENDED TO BE READ IN CONJUNCTION WITH SCHEDULES, WALLS, OPENINGS OR COMBUSTIBLE ROOF EAVE LINES UNLESS AREAS CONTAINING
CONTRACT DOCUMENTS OR WHERE REQUIRED APPROVED SHOP DRAWINGS, PRODUCT COPING WHEN OF METAL, SHALL BE MINIMUM 24 GA. GALVANIZED OR BONDERIZED IF
DETAILS AND SPECIFICATIONS EMBODIED IN THE PROJECT MANUAL(S). NO ONE
BUREAU OF ENGINEERING
DATA, OR SAMPLES FOR PORTIONS OF THE WORK. PAINTED. AT ALL ROUGH OPENINGS IN EXT. WALL OF BUILDING, CONTRACTOR SHALL
DRAWING OR SPECIFICATION SCHEDULE SHALL "GOVERN". CONTRACTOR SHALL
PROVIDE, AT A MINIMUM, SELF-HEALING FLASHING WATERPROOFING, LAPPED A MIN. OF 8. PROVIDE FIRE RESISTIVE CONSTRUCTION AS NOTED ON PLANS.
5. REQUIREMENTS FOR REGULATORY AGENCIES: ALL PERTAINING STATUTES, CORRELATE WORK BETWEEN ARCHITECTURAL DRAWINGS AND SPECIFICATIONS AND
ORDINANCES, LAWS, RULES, CODE REGULATIONS, STANDARDS, AND THE LAWFUL CONSULTANT DRAWINGS AND SPECIFICATIONS. IT IS THE EXPLICIT AND SPECIFIC 6" BEYOND OPENING. SEE DETAILS AND SPECIFICATIONS. 9. FIRE RESISTIVE ASSEMBLIES FOR PROTECTION OF OPENINGS SHALL COMPLY WITH
ORDERS OF ALL PUBLIC AUTHORITIES HAVING JURISDICTION OF THE WORK, ARE RESPONSIBILITY OF THE CONTRACTOR TO EXAMINE THE CONTRACT DOCUMENTS IN 10. NOT USED. BUILDING CODE:2017 CBC SECTION 715.
HEREBY INCORPORATED INTO THESE CONTRACT DOCUMENTS THE SAME AS IF THEIR ENTIRETY, REPORT ALL WITH ANY WORK AFFECTED BY SUCH DISCREPANCIES. 10. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE
11. ALL OUTSWINGING EXTERIOR DOORS SHALL HAVE DRIPS AT THE HEAD OF THE DOOR,
REPEATED IN FULL HEREIN AND SUCH ARE INTENDED WHERE ANY REFERENCE IS MADE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.
23. GENERAL NOTES ARE AN AID TO THE CONTRACTOR IN UNDERSTANDING THE WORK AND TYPICALLY, IF NOT COVERED WITH A CANOPY OR OVERHANG.
IN EITHER THE SINGULAR OR PLURAL TO CODE OR BUILDING CODE UNLESS OTHERWISE
SHOULD NOT BE CONSTRUED AS BEING COMPLETE IN EVERY DETAIL. IT IS THE EXPLICIT 11. SHAFTS SHALL BE ENCLOSED IN COMPLIANCE WITH 2017 CBC, SECTION 708. EXT. WALLS
SPECIFIED INCLUDING WITHOUT LIMITATION, THOSE IN THE SITE LIST BELOW. 12. CONTRACTOR SHALL PROVIDE A GYP. BOARD ACCESS PANEL AT ALL DAMPER
GENERAL NOTES
24. ALL LINES, SYMBOLS, NOTES, POCHE AND OTHER GRAPHIC DEVICES CONTAINED IN THE CONSTRUCTION OR THE FIRE RESISTANCE-RATING OF THE STAIR ENCLOSURE,
PART 1 2019 CALIFORNIA ADMINISTRATIVE CODE, CA CODE OF REGULATIONS TITLE 24 C.C.R, CONTRACT DOCUMENTS CARRY SPECIFIC OR INFERENTIAL MEANING. ITEMS INDICATED 14. AT ALL WOOD STUD WALL SILL PLATES, PROVIDE SILL SEAL BY DOW (OR EQUAL) WHICHEVER IS GREATER. SPACES UNDER STAIRWAYS WITHIN A SINGLE RESIDENTIAL
PART 1 IN THESE WAYS ARE PART OF THE SCOPE OF WORK AND WILL BE REQUIRED BY THE BETWEEN WOOD STUD AND CONCRETE TO FULLY SEAL THE CONNECTION BETWEEN DWELLING UNIT IN R1 OR R2 OCCUPANCIES, SHALL BE PROTECTED ON THE ENCLOSED
OWNER AND ARCHITECT TO BE INCLUDED IN THE CONTRACTOR'S ORIGINAL BID. ANY FOUNDATION AND SILL PLATE. SIDE WITH MIN HALF-INCH GYP BRD. THE OPEN SPACE UNDER EXTERIOR STAIRWAYS
PART 2 2019 CALIFORNIA BUILDING CODE, CALIFORNIA CODE OF REGULATIONS TITLE 24 C.C.R,
VOLUMES 1 AND 2 (BASED ON THE 2012 INTERNATIONAL BUILDING CODE, WITH ITEMS WHICH REQUIRE FURTHER CLARIFICATION BY THE ARCHITECT FOR THE SPECIFIC 15. NOT USED SHALL NOT BE USED FOR ANY PURPOSE.
CALIFORNIA AMENDMENTS, ALSO REFERRED TO AS "CBC"). BENEFIT OF THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT FOR SUCH CLARIFICATION BEFORE COMMENCEMENT OF ANY WORK AND SECURITY 13. ALL PENETRATIONS AND/OR GAPS IN RATED WALLS, FLOORS, CEILINGS ROOFS, ETC.
HORIZONTAL CONTROL:
PART 3 2019 CALIFORNIA ELECTRICAL CODE, CALIFORNIA CODE OF REGULATIONS TITLE 24 SUBMITTAL OF FINAL BID. INCLUDING, BUT NOT LIMITED TO, PLUMBING PIPES, SHAFTS, VENT PIPES, DUCTS AND OR
VERTICAL CONTROL:
1. GLAZED OPENINGS WITHIN 40" OF THE DOOR LOCK WHEN THE DOOR IS IN THE CLOSED ANY PENETRATION, SHALL BE SEALED AND/OR CAULKED WITH AN APPROVED MATERIAL
C.C.R, PART 3 (BASED ON THE 2011 NATIONAL ELECTRICAL CODE, ALSO REFERRED TO POSITION, SHALL BE FULLY TEMPERED GLASS OR APPROVED BURGLARY RESISTANT
25. THE CONTRACTOR SHALL PAY SPECIFIC ATTENTION TO ALL DIMENSIONED OR
G AS "CEC").
INFERENTIAL PLAN AND SECTIONAL SPATIAL RELATIONSHIPS, AND SHALL VERIFY ALL MATERIAL OR SHALL BE PROTECTED BY METAL BARS, SCREENS OR GRILLS HAVING A
TO MEET THAT CONSTRUCTION RATING OF THE SURFACEAND/OR ASSEMBLY WHICH IT
PENETRATES.
SHEET TITLE:
PART 4 2019 CALIFORNIA MECHANICAL CODE, CALIFORNIA CODE OF REGULATIONS TITLE 24 AXES AND SYMMETRIES BEFORE COMMENCING WORK. MAXIMUM OPENING OF 2". THE PROVISIONS OF THIS SECTION SHALL NOT APPLY TO VIEW
ADDRESS:
PROJECT:
PORTS OR WINDOWS WHICH DO NOT EXCEED 2" IN THEIR GREATEST DIMENSIONS. 14. RECESSED LIGHTS SHALL BE ENCLOSED IN A MANNER TO ACHIEVE AN APPROVED
C.C.R, PART 4 (BASED ON THE 2012 UNIFORM MECHANICAL CODE, ALSO REFERRED TO 26. ANY DIMENSIONS MARKED "VERIFY" ARE TO CHECKED FOR ACCURACY BY THE ONE-HOUR FIRE RESISTIVE CONSTRUCTION, IF LOCATED IN A ONE-HOUR ASSEMBLY.
AS "CMC"). CONTRACTOR AS WORK PROGRESSES, AND ALL DISCREPANCIES ARE TO BE BROUGHT 2. DOOR STOPS OF IN-SWINGING DOORS SHALL BE OF ONE-PIECE CONSTRUCTION WITH
TO THE ARCHITECT BEFORE PROCEEDING. THE JAMB OR JOINED BY RABBET TO THE JAMB. 15. PROVIDE SMOKE DETECTORS TO COMPLY WITH BUILDING CODE REGARDING FIRE
PART 5 2019 CALIFORNIA PLUMBING CODE, CALIFORNIA CODE OF REGULATIONS TITLE 24 C.C.R,
WARNING SYSTEMS. SMOKE DETECTORS SHALL BE HARD WIRED W/ BATTERY BACKUP.
PART 5 (BASED ON THE 2012 UNIFORM PLUMBING CODE, ALSO REFERRED TO AS "CPC"). 27. THE DIMENSIONS MARKED "CLEAR" ARE NOT ADJUSTABLE WITHOUT THE WRITTEN 3. ALL PIN-TYPE HINGES WHICH ARE ACCESSIBLE FROM OUTSIDE THE SECURED AREA
AUTHORIZATION OF THE ARCHITECT. WHEN THE DOOR IS CLOSED SHALL HAVE NON-REMOVABLE HINGE PINS. IN ADDITION, 16. INTERIOR WALL AND CEILING FINISHES SHALL BE AS REQ'D BY 2017 CBC, TABLE 803.9.
BY:
THEY SHALL HAVE MINIMUM 1/4" DIAMETER STEEL JAMB STUD WITH 1/4" MINIMUM FOR FULLY SPRINKLERED BUILDING: B&E OCCUPANCY, FLAME SPREAD INDEX SHALL BE
28. NOT USED "C" MIN. AT CORRIDORS/ROOMS AND "B" MIN AT EXIT PASSAGEWAYS. FOR
PART 7 2019 CALIFORNIA ELEVATOR SAFETY CONSTRUCTION CODE, CA CODE OF REGULATIONS, PROTECTION UNLESS THE HINGES ARE SHAPED TO PREVENT REMOVAL OF THE DOOR IF
DATE:
A-OCCUPANCIES FLAME SPREAD INDEX SHALL BE "B" MIN.
CIP NO.
TITLE 24 C.C.R., PART 7. 29. NO CERTIFICATE OF OCCUPANCY FOR NEW BUILDINGS SHALL BE ISSUED UNLESS OR THE HINGE PINS ARE REMOVED.
UNTIL ALL EXISTING & PROPOSED ELECTRICAL LINES AND OVERHEAD SERVICE DROP 17. ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR FLAME- RETARDANT
PART 8 2019 CALIFORNIA HISTORICAL BUILDING CODE, CA CODE OF REGULATIONS TITLE 24 4. THE STRIKE PLATE FOR LATCHES AND THE HOLDING DEVICE FOR PROTECTING
F C.C.R, PART 8.
CONDUCTORS, AND ALL GAS, TELEPHONE, TELEVISION CABLE SERVICE WIRES OR LINES,
DEADBOLTS IN WOOD CONSTRUCTION SHALL BE SECURED TO THE JAMB AND THE WALL TREATED IN AN APPROVED MANNER, INCLUDING CURTAINS, DRAPES, SHADES,
WHICH ARE ON-SITE, ABUTTING, AND/OR TRANSECTING, ARE COMPLETE, AND SERVICE HANGINGS, ETC.
FRAMING WITH SCREWS NOT LESS THAN 2-1/2" IN LENGTH. STRIKE PLATES SHALL BE A
PART 9 2019 CALIFORNIA FIRE CODE, CALIFORNIA CODE OF REGULATIONS TITLE 24 C.C.R, REQUIREMENTS PUBLISHED BY THE UTILITIES.
MINIMUM OF 31/2" IN LENGTH. 18. PROVIDE EXIT SIGNS AND DIRECTIONAL EXIT SIGNS WITH MINIMUM 6" HIGH BY 3/4"
(BASED ON THE 2012 UNIFORM FIRE CODE, ALSO REFERRED TO AS "CFC").
30. DESIGN WORK IS THE RESPONSIBILITY OF THE ARCHITECT. ANY DESIGN CHANGES MADE 5. DEADBOLTS SHALL HAVE HARDENED INSERTS: DEADLOCKING LATCH, KEY-OPERATED STROKE BLOCK LETTERS ON A CONTRASTING BACKGROUND. LOCATIONS OF EXIT SIGNS
PART 11 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE, CODE OF REGS, TITLE 24, PART BY THE CONTRACTOR SHALL BE THE FULL RESPONSIBILITY AND LIABILITY OF THE LOCKS ON EXTERIOR; LOCKS OPENABLE WITHOUT KEY, SPECIAL KNOWLEDGE OR ARE INDICATED ON FLOOR PLANS.
11. (CALGREEN CODE). CONTRACTOR. SPECIAL EFFORT ON INTERIOR AND TYPE-THROW, AND EMBEDMENT OF DEADBOLTS FOR 19. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. EXIT SIGNS
PART 12 2019 CALIFORNIA REFERENCE STANDARDS CODE, CA CODE OF REGULATIONS TITLE 24 31. WORKMANSHIP SHALL BE THE HIGHEST QUALITY NORMALLY OBTAINABLE IN THE SINGLE SWINGING DOOR, ACTIVE LEAF OR PAIRS OF DOORS, OR BOTTOM LEAF OF ILLUMINATED BY AN EXTERNAL SOURCE SHALL HAVE AN INTENSITY OF NOT LESS THAN 5
C.C.R, PART 12. RESPECTIVE TRADES AND EXECUTED BY SKILLED JOURNEYMEN. WORK WHICH IN THE DUTCH DOOR. FOOT CANDLES. INTERNALLY ILLUMINATED SIGNS SHALL BE LISTED AND LABELED AND
OPINION OF THE ARCHITECT IS INFERIOR OR IMPROPERLY PERFORMED, SHALL BE 6. STRAIGHT DEADBOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN EMBEDMENT OF SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND
B) TITLE 24 CAC, BUILDING STANDARDS, INCLUDING ARCHITECTURAL BARRIER LAWS AND REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE. NOT LESS THAN 5/8". SECTION 2702. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. EXIT SIGNS SHALL BE
REGULATIONS REGARDING ACCESSIBILITY, CURRENT EDITION.
32. UNSPECIFIED MATERIALS SHALL BE NEW, FIRST LINE PRODUCTS OF A RECOGNIZED CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL PROVIDE AN ILLUMINATION
7. A HOOK-SHAPED OR AN EXPANDING LUG DEADBOLT SHALL HAVE MIN. 3/4" THROW.
C) 2019 CALIFORNIA BUILDING CODE REFERENCED STANDARDS CHAPTER 35 (PARTIAL LIST OF NOT LESS THAN 90 MINUTES IN CASE OF PRIMARY POWER LOSS (1011.2-1011.5.3).
E OF APPLICABLE STANDARDS):
MANUFACTURER. NO SUBSTITUTIONS FROM SPECIFICATIONS SHALL BE USED UNLESS
8. CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDER LOCKS WHENEVER THE
APPROVED BY THE ARCHITECT. UNDER NO CIRCUMSTANCES WILL SUBSTITUTIONS BE 20. ROOF COVERING SHALL BE CLASS A FIRE RETARDANT.
NFPA 13 AUTOMATIC SPRINKLER SYSTEMS (2019 EDITION) ALLOWED DUE TO CONTRACTOR'S FAILURE TO ORDER PRODUCTS IN A TIMELY MANNER CYLINDER PROJECTS BEYOND THE FACE OF THE DOOR OR IS OTHERWISE ACCESSIBLE
TO MEET CONSTRUCTION SCHEDULES. WHERE AVAILABLE OR REQUIRED, TO GRIPPING TOOLS. 21. ALL EXITS MUST BE CONTINUOUS AND TERMINATE IN A PUBLIC WAY OR EXIT COURT
NFPA 14 STANDPIPE SYSTEMS (2019 EDITION) MANUFACTURER'S GUARANTEE SHALL BE PROVIDED IN WRITING. LEADING TO A PUBLIC WAY OR APPROVED REFUGE AREA. EXIT PATH LIGHTING SHALL BE
9. IN B OCCUPANCIES, PANES OF GLAZING WITH A DIMENSION GREATER THAN 6" BUT LESS
REVISIONS:
33. ALL CONSTRUCTIONS AND INSTALLATIONS SHALL CONFORM TO MANUFACTURER'S THAN 48" SHALL BE FULLY TEMPERED GLASS OR APPROVAL BURGLAR-RESISTANT PROVIDED FOR STAIRWAY, HALLWAY, EXIT PASSAGEWAY AND FOR EGRESS (INCLUDING
NFPA 72 NATIONAL FIRE ALARM CODE (2019 EDITION)
PUBLISHED SPECIFICATIONS AS WELL AS THE LATEST EDITION OF THE CALIFORNIA MATERIAL OR SHALL BE PROTECTED BY METAL BARS OR GRILLS WITH OPENINGS THAT THE EXIT DISCHARGE) TO A PUBLIC WAY ANY TIME THE BUILDING IS OCCUPIED. THE
D) 2019 CITY OF LA FIRE CODE HAVE AT LEAST ONE DIMENSION OF 6" OR LESS. MEANS OF EGRESS ILLUMINATION SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT THE
INDEX NO.
BUILDING CODE WITH ALL STATE AND LOCAL ADOPTED ORDINANCES AND A COPY OF
THESE STIPULATIONS SHALL BE AVAILABLE AT THE CONSTRUCTION OFFICE. WALKING SURFACE.
E) CITY OF LOS ANGELES MUNICIPAL CODE (LAMC) 10. SCREENS, BARRICADES, OR FENCES MADE OF MATERIAL WHICH PRECLUDE HUMAN
22. PROVIDE AN APPROVED FIRE ALARM SYSTEM WITH AUDIBLE AND VISIBLE ALARMS AS
NO.
F) OTHER STATUTES, ORDINANCES, LAWS, REGULATIONS, RULES, ORDER, AND CODES AS 34. THE METHODS AND SAFETY OF CONSTRUCTION ARE THE RESPONSIBILITY OF CLIMBING SHALL BE PROVIDED AT EVERY PORTION OF ROOF, BALCONY, OR SIMILAR OR
CONTRACTOR AND HIS ASSIGNEES. SIMILAR SURFACE WHICH IS WITHIN 8' OF THE OF A UTILITY POLE OR SIMILAR PER NFPA-72. SEE ELECTRICAL SPECIFICATIONS & DWGS. PROVIDE AUDIBLE AND
SPECIFIED IN OTHER SECTIONS OF THE SPECIFICATIONS OR BEARING ON THE WORK. VISIBLE ALARM NOTIFICATION PER CFC 907.6.
STRUCTURE.
35. THE CONTRACTOR SHALL COORDINATE THE WORK OF ALL SUBCONTRACTORS,
D 6. CONTRACTOR SHALL PROVIDE SAFEGUARDS DURING CONSTRUCTION AS PER CH.33 OF
INCLUDING THOSE UNDER SEPARATE CONTRACT WITH THE OWNER. 11. ALL GLASS DOORS SHALL HAVE FULLY TEMPERED GLASS. 23. FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED ON EXIT DOORS.
2017 CBC.
CITY ENGINEER
DATE:
36. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR THE WORK IN HIS TRADE REQUIRED 12. GLAZING ADJACENT TO A DOOR AND WITHIN THE SAME WALL PLANE AS THE DOOR 24. PANIC HARDWARE SHALL BE PROVIDED ON EXIT DOORS SERVING ROOMS, CORRIDORS
7. CONTRACTOR SHALL PROVIDE TEMPORARY CHEMICAL TOILETS AND OTHER FACILITIES
BY ALL OTHER TRADES, I.E. OPENINGS, HOLES, BLOCKING, BRACING, ETC. WHOSE NEAREST VERTICAL EDGE IS WITHIN 12" OF THE DOOR IN A CLOSED POSITION OR STAIRWAYS HANDLING AN OCC. LOAD OF 50 OR MORE PERSONS. PANIC HARDWARE
AS REQUIRED. UTILITIES WILL NOT BE PROVIDED BY THE OWNER. ANY CHEMICAL TOILET
AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE FLOOR OR WALKING SURFACE SHALL BE PROVIDED ON EXIT DOORS SERVING ELECTRICAL ROOMS WITH EQUIPMENT
SHALL BE CLEANED A MINIMUM ONCE PER WEEK. 37. WHERE CONSTRUCTION MATERIALS ARE TEMPORARILY STORED ON ROOF OR FLOOR
SHALL BE TEMPERED. RATED OVER 1,200 AMPERES AND OVER 6 FEET WIDE THAT CONTAIN OVERCURRENT,
8. CONTRACTOR SHALL PROVIDE SAFEGUARDS DURING CONSTRUCTION AS PER CH.33 OF FRAMING, THEY SHALL BE DISTRIBUTED SO THAT LOAD DOES NOT EXCEED DESIGN LIVE CONTROL OR SWITCHING DEVICES PER CBC 1008.1.10. DOORS SHALL SWING IN THE
2017 CBC. PROVIDE PEDESTRIAN AND PROPERTY PROTECTION BARRICADES AND/OR LOAD. ADEQUATE STORING AND/OR BRACING SHALL BE PROVIDED WHERE STRUCTURAL 13. GLAZING IN FIXED PANELS WHICH HAVE A GLAZED AREA IN EXCESS OF 9 SQUARE FEET DIRECTION OF EXIT TRAVEL.
CANOPIES AS REQUIRED BY THE LOCAL AUTHORITIES, OR AS NECESSARY FOR MEMBERS HAVE NOT ATTAINED DESIGN STRENGTH. AND THE LOWEST EDGE IS LESS THAN 18" ABOVE THE FINISHED FLOOR LEVEL OR
WALKING SURFACE WITHIN 36" OF SUCH GLAZING SHALL BE TEMPERED. 25. CONSTRUCTION AND DEMOLITION: STRUCTURES IN THE COURSE OF CONSTRUCTION,
PEDESTRIAN SAFETY. A PERMIT FROM THE DEPT. OF PUBLIC WORKS AND/OR BUILDING 38. ANY WASTE CAUSED BY THIS WORK SHALL BE REMOVED FROM THE PREMISES AND ALTERATION OR DEMOLITION SHALL COMPLY WITH CHAPTER 14 OF 2017 CITY OF LA FIRE
& SAFETY IS REQUIRED FOR A PROTECTION FENCE OR CANOPY OVER OR ON ANY DISPOSED OF BY THE CONTRACTOR, INCLUDING EXCESS SOIL REMOVAL AND CLEAN TOP 14. NOT USED CODE AND NFPA 241.
STREET, SETBACK OR PUBLIC WAY. THE ERECTION AND PLACEMENT OF ANY SOIL PROVIDED IN PLANTED AREAS. DEMOLITION IS NOT SHOWN IN ITS ENTIRETY-
CONSTRUCTION OFFICE SHALL BE SUBJECT TO APPROVAL OF THE BUILDING & SAFETY 15. THE INACTIVE LEAF OF DOUBLE DOORS SHALL BE EQUIPPED WITH FLUSH BOLTS HAVING 26. FIRE DEPARTMENT CONNECTIONS (CFC SECT. 912): FIRE DEPARTMENT CONNECTIONS
REMOVE ALL (E) CONSTRUCTION REQUIRED TO COMPLETE THE WORK.
C DIRECTOR CONCERNING LOCATION AND DURATION. A MINIMUM EMBEDMENT OF FIVE-EIGHTS INCH INTO THE HEAD AND THRESHOLD OF THE SHALL BE VISIBLE AND ACCESSIBLE, HAVE TWO 2.5 INCH NST FEMALE INLETS, AND HAVE
39. LICENSES AND PERMITS NECESSARY TO THE PERFORMANCE, COMPLETION AND DOOR FRAME. AN APPROVED CHECK VALVE LOCATED AS CLOSE TO THE FDC AS POSSIBLE. ALL FDC'S
DESIGN GROUP
9. ALL OPENINGS IN EXTERIOR WALLS OR ROOFS WHICH ARE LESS THAN 16' (SIXTEEN APPROVAL OF THE WORK, AND ALL INSPECTION AND OTHER APPLICABLE FEES 16. NOT USED SHALL HAVE KNOX LOCKING PROTECTIVE CAPS.
FEET) ABOVE ADJACENT AREAS ACCESSIBLE TO THE PUBLIC SHALL BE CONSIDERED (EXCLUDING BUILDING PERMIT FILING FEE) SHALL BE SECURED AND PAID FOR BY THE
SECURITY OPENINGS AND SHALL COMPLY TO THE PROVISIONS FOR SECURITY IN THE 17. WHERE PANIC HARDWARE IS REQUIRED BY THE UNIFORM BUILDING CODE OR TITLE 19, 27. ACCESS DURING CONSTRUCTION (CFC CH 14): ACCESS FOR FIREFIGHTING EQUIPMENT
CONTRACTOR.
CALIFORNIA BUILDING CODE. CALIFORNIA ADMINISTRATIVE CODE, IT SHALL BE EQUIPPED AND INSTALLED AS SHALL BE PROVIDED TO THE IMMEDIATE JOB SITE AT THE START OF CONSTRUCTION
40. ANY GEOLOGY AND SOILS REPORTS AND ATTENDANT APPROVAL BY THE GOVERNING AND MAINTAINED UNTIL ALL CONSTRUCTION IS COMPLETE. FIRE APPARATUS ACCESS
10. IMPROVEMENTS ON THE SITE, WORK IN PROGRESS, STORED MATERIALS, AND PUBLIC FOLLOWS:
AGENCY ARE A PART OF THESE PLANS. ANY REQUIREMENTS CALLED FOR IN THEM ROADS SHALL HAVE AN UNOBSTRUCTED WIDTH OF NOT LESS THAN 20 FEET AND AN
AND PRIVATE IMPROVEMENTS ON PROPERTY ADJACENT TO THE SITE SHALL BE SHALL BE PART OF THE CONTRACT AND PERFORMED AS CALLED FOR, WHETHER A) PANIC HARDWARE SHALL CONTAIN MIN. OF (2) LOCKING POINTS ON EACH DOOR; OR UNOBSTRUCTED VERTICAL CLEARANCE OF NOT LESS THAN 13'-6". FIRE DEPARTMENT
PROTECTED BY THE CONTRACTOR FROM DAMAGE ARISING FROM THE WORK. ALL INDICATED ON THE DRAWINGS OR NOT. B) ON SINGLE DOORS, PANIC HARDWARE MAY HAVE ONE LOCKING POINT WHICH IS NOT TO ACCESS ROADS SHALL HAVE AN ALL WEATHER DRIVING SURFACE AND SUPPORT A
DAMAGE SO OCCURRING SHALL BE REPAIRED OR DAMAGED ITEM SHALL BE REPLACED
41. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK REQUIRED BY ONE TRADE TO BE LOCATED AT EITHER THE TOP OR BOTTOM RAILS OF THE DOOR FRAME. THE DOOR MINIMUM WEIGHT IF 73,000 LBS.
BY THE CONTRACTOR AT NO COST TO THE OWNER.
APPROVED BY:
RESPONSIBLE FOR ALL ASSOCIATED COSTS.
DESIGNED BY:
EXTENT OF THESE CONDITIONS WILL BE VERIFIED BY THE ARCHITECT AND CONTRACTOR
CHECKED BY:
INCHES WIDE AND EXTEND A MIN. OF ONE INCH BEYOND THE EDGE OF THE DOOR. HEAD DEFLECTORS IN SPRINKLERED AREAS OF BLDG.
DRAWN BY:
ENGINEER:
WILL NOT BE HELD RESPONSIBLE FOR CORRECTION OF SUCH DAMAGE UPON 43. THE CONTRACTOR SHALL PROVIDE A $500.00 ALLOWANCE FOR A JOBSITE SIGN. SIZE
COMPLETION OF WORK, UNLESS INCLUDED IN THE CONTRACT BY MUTUAL CONSENT. AND LAYOUT SHALL BE DETERMINED BY THE ARCHITECT. C) DOUBLE DOORS CONTAINING PANIC HARDWARE SHALL HAVE AN ASTRAGAL ATTACHED
TO THE DOORS AS THEIR MEETING POINT WHICH WILL CLOSE THE OPENING BETWEEN
12. PROVIDE SUPPORTS, SHORING AND BRACING AS REQUIRED. ALL PITS, HOLES, THEM BUT NOT INTERFERE WITH THE OPERATION OF EITHER DOOR.
TRENCHES OR EXCAVATIONS 5' OR MORE IN DEPTH MUST BE PROPERLY SHORED AND GENERAL NOTES CONTINUE ON SHEET A0.11.
SUPPORTED.
13. OVERLOADING: DO NOT OVERLOAD ANY PART OF THE STRUCTURES BEYOND THE SAFE WORK ORDER NO.
CARRYING CAPACITY BY PLACING OF MATERIALS, EQUIPMENT, TOOLS, MACHINERY OR E170121B
ANY OTHER ITEM THEREON. LOAD LIMIT AT SLABS-ON-GRADE IS 1,000 LB/SF MAX. LOAD
(DESIGN STAGE ONLY)
A0.10
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A010_24X36.DWG 12/3/2021 9:06 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
GENERAL NOTES CONTINUED FROM SHEET A0.10. ENGINEERING
30. MAINTENANCE OF FIRE-RESISTANCE-RATED CONSTRUCTION (CFC 703.1): THE REQUIRED 8. PROVIDE OUTLETS AS REQUIRED BY CODE WHETHER SHOWN ON THE PLANS OR NOT. METAL STUD FRAMING/WHERE OCCURS 11. FLUSH OR RECESSED LIGHT FIXTURES AND AIR TERMINALS OR SERVICES, WEIGHING
FIRE-RESISTANCE RATING OF FIRE-RESISTANCE-RATED CONSTRUCTION (INCLUDING LESS THAN 56 LBS., MAY BE SUPPORTED DIRECTLY ON THE RUNNERS OF A HEAVY DUTY
9. NEW EXTERIOR PLASTER WALLS: ALL TERMINAL EDGES OF PLASTER SHALL HAVE A 1. ALL PARTITION FRAMING SHALL REFER TO THE WALL TYPES ON THE ARCHITECTURAL
WALLS, FIRESTOPS, SHAFT ENCLOSURES, PARTITIONS, SMOKE BARRIERS, FLOORS, GRID SYSTEM BUT, IN ADDITION, THEY MUST HAVE A MINIMUM OF TWO 12 GA. SLACK
K FIRE-RESISTIVE COATINGS AND SPRAYED FIRE-RESISTANT MATERIALS APPLIED TO
PLASTER SCREED APPROPRIATE FOR THE GIVEN CONDITION, WHETHER INDICATED ON DRAWINGS.
SAFETY WIRES ATTACHED TO THE FIXTURE AT DIAGONAL CORNERS AND ANCHORED TO
PLANS OR NOT. 2. ALL TOP & BOTTOM TRACK DETAILS AT NON-LOAD BEARING PARTITIONS SHALL REFER
STRUCTURAL MEMBERS AND FIRE-RESISTANT JOINT SYSTEMS) SHALL BE MAINTAINED. THE STRUCTURE ABOVE. ALL 4' X 4' LIGHT FIXTURES MUST HAVE SLACK SAFETY WIRES
SUCH ELEMENTS SHALL BE PROPERLY REPAIRED, RESTORED OR REPLACED WHEN 10. ALL DOOR STRIKES WHETHER HEREIN SPECIFIED OR NOT SHALL HAVE TONGUES TO TO ARCH. DWGS. AT EACH CORNER. ALL FLUSH OR RECESSED LIGHT FIXTURES AND AIR TERMINALS OR
DAMAGED, ALTERED, BREACHED OR PENETRATED. OPENINGS MADE THEREIN FOR THE CLEAR ALL ADJACENT SURFACES SO THAT THE DOOR LATCH TOUCHES ONLY THE 3. WEB STIFFENER IS REQUIRED AT ALL SUPPORTS, UNLESS OTHERWISE NOTED. SERVICES WEIGHING 56 LBS. OR MORE MUST BE INDEPENDENTLY SUPPORTED BY NOT
PASSAGE OF PIPES, ELECTRICAL CONDUIT, WIRES, DUCTS, AIR TRANSFER OPENINGS STRIKE WHEN OPENING AND CLOSING. LESS THAN FOUR (4) TAUT 12 GA. WIRES EACH ATTACHED TO THE FIXTURE AND TO THE
AND HOLES MADE FOR ANY REASON SHALL BE PROTECTED WITH APPROVED METHODS 4. USE DOUBLE JOISTS UNDER WALLS OR PARTITIONS PARALLEL TO JOISTS. USE SOLID STRUCTURE ABOVE REGARDLESS OF THE TYPE OF CEILING GRID SYSTEM USED.
11. CONCRETE WATERPROOFING. ALL COLD JOINTS BETWEEN CONCRETE SLABS, WALLS
CAPABLE OF RESISTING THE PASSAGE OF SMOKE AND FIRE.OPENINGS THROUGH BLOCKING UNDER PARTITIONS PERPENDICULAR TO JOISTS PER PLANS.
AND/OR FOUNDATIONS AND OTHER CONDITIONS WITHIN 2" ABOVE FINISH GRADE AND * THE FOUR (4) TAUT 12 GA. WIRES INCLUDING THEIR ATTACHMENT TO THE STRUCTURE
FIRE-RESISTANCE-RATED ASSEMBLIES SHALL BE PROTECTED BY SELF- OR BELOW THAT LEVEL SHALL HAVE A CONTINUOUS 2" WIDE STRIP (MINIMUM) OF SELF 5. ALL TRACKS AND RUNNERS TO BE 18 GA DEEP LEG TRACK BY 'CEMCO'. SEE NOTE 3. ABOVE MUST BE CAPABLE OF SUPPORTING FOUR (4) TIMES THE WEIGHT OF THE UNIT.
AUTOMATIC-CLOSING DOORS OF APPROVED CONSTRUCTION MEETING THE FIRE SEALING BENTONITE BY PARAMOUNT TECHNICAL PRODUCTS, INC. (PRODUCT NAME
PROTECTION REQUIREMENTS FOR THE ASSEMBLY. 6. WALL TRACKS SHALL NOT BE USED TO SUPPORT ANY LOADS. 12. ALL FIXTURES AND AIR TERMINALS OR SERVICES SUPPORTED ON INTERMEDIATE DUTY
"PARASTOP").
7. PROVIDE SOLID BLOCKING OR BRIDGING AT WALLS PER MANUFACTURERS GRID SYSTEMS MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR (4)
31. KEY BOX REQUIRED TO BE INSTALLED (CFC 506.1): WHERE ACCESS TO OR WITHIN A 12. ALL FLAT ROOFS, DECKS AND ANY SURFACES THAT THE SOLE METHOD OF WATER RECOMMENDATIONS. TAUT 12 GA. WIRES EACH ATTACHED TO THE FIXTURE OR TERMINAL, AND TO THE
STRUCTURE OR AN AREA IS RESTRICTED BECAUSE OF SECURED OPENINGS OR WHERE
J IMMEDIATE ACCESS IS NECESSARY FOR LIFE-SAVING OR FIRE-FIGHTING PURPOSES, THE
DRAINAGE IS VIA INTEGRAL DRAINS SHALL HAVE A MIN. 3" DIAMETER OVERFLOW
8. APPLY BRIDGING AT FLOOR JOISTS PER MANUFACTURER RECOMMENDATIONS.
STRUCTURE ABOVE.
SCUPPER LOCATED SUCH AND IN QUANTITY TO PREVENT PONDING AND/OR BUILD-UP
FIRE CODE OFFICIAL IS AUTHORIZED TO REQUIRE A KEY BOX TO BE INSTALLED IN AN 13. SUPPORT SURFACE MOUNTED LIGHT FIXTURES BY AT LEAST TWO POSITIVE DEVICES
COLLECTION OF WATER IN CASE OF CLOGGING AND/OR FAILURE OF INTEGRAL DRAINS. 9. ALL STUDS AND JOISTS ARE TO BE GALVANIZED.
APPROVED LOCATION. CONTACT THE FIRE DEPARTMENT FOR A KNOX APPLICATION WHICH SURROUND THE CEILING RUNNER AND WHICH ARE EACH SUPPORTED FROM THE
ALL AREAS THAT RELY ON SUCH SAID DRAINAGE SHALL BE FLASHED AND
FORM. THE KNOX KEY BOX SHALL CONTAIN KEYS TO ALL AREAS OF INGRESS/EGRESS, 10. AXIALLY LOADED STUD WALLS SHALL BE INSTALLED SEATED SQUARELY AGAINST THE STRUCTURE ABOVE BY A 12 GA. WIRE. SPRING CLIPS OR CLAMPS THAT CONNECT ONLY
WATERPROOFED ABOVE THE HEIGHT OF THE OVERFLOW SCUPPER SO THAT THE
ALARM ROOMS, FIRE SPRINKLER RISER/EQUIPMENT ROOMS, MECHANICAL ROOMS, WEB PORTION OF THE TOP AND BOTTOM TRACKS. TO THE RUNNER ARE NOT ACCEPTABLE.
SCUPPER MAY DRAIN EXCESS WATER WITHOUT WATER PENETRATION INTO THE
ELEVATOR ROOMS, ELEVATOR CONTROLS, PLUS A CARD CONTAINING THE EMERGENCY INTERIOR OF THE STRUCTURE FORM THE AREAS THAT RELY ON THIS SYSTEM OF 14. SUPPORT PENDANT MOUNTED LIGHT FIXTURES DIRECTLY FROM THE STRUCTURE 10/31/2023
11. ALL DOOR JAMBS TO HAVE TRACK STIFFENER PER AND MANUFACTURER
CONTACT PEOPLE AND PHONE NUMBERS FOR THE BUILDING/COMPLEX. DRAINAGE. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLATION OF SCUPPERS ABOVE WITH HANGER WIRES OR CABLES PASSING THROUGH EACH PENDANT HANGER
RECOMMENDATIONS.
32. PLOT PLAN: PRIOR TO COMPLETION OF THE PROJECT, A 8.5" X 11" PLOT PLAN AND AN WHETHER OR NOT THEY ARE SHOWN ON THESE PLANS. AND CAPABLE OF SUPPORTING FOUR (4) TIMES THE WEIGHT OF THE FIXTURE.
12. END BLOCKING SHALL BE PROVIDED WHERE JOIST ENDS ARE NOT OTHERWISE
ELECTRONIC CAD VERSION SHALL BE PROVIDED BY THE CONTRACTOR TO THE FIRE GENERAL MATERIAL NOTES ADDITIONAL GENERAL REQUIREMENTS
RESTRAINED FROM ROTATION.
DEPARTMENT. THIS SHALL CLEARLY SHOW ALL ACCESS POINTS, FIRE HYDRANTS, KNOX
BOX LOCATIONS, FIRE DEPARTMENT CONNECTIONS, UNIT IDENTIFIERS, MAIN CONCRETE 13. SCREW SPACING AND EDGE DISTANCE SHALL NOT BE LESS THAN 1.5 X DIAMETER OF 1 THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED
ELECTRICAL PANEL LOCATIONS, SPRINKLER RISER AND FIRE ALARM LOCATIONS. LARGE THE SCREW. ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES,
I PROJECTS MAY REQUIRE MORE THAN ONE PAGE.
1. CONTRACTOR SHALL ASSUME THAT ALL CONCRETE STEPS OR STAIRS HAVE
14. THE CONTRACTOR IS TO PROVIDE ALL ACCESSORIES INCLUDING BUT NOT NECESSARILY PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES,
REINFORCEMENT OF: #4 NOSING & BOTTOM EACH RISER AND BOTTOM #6 BARS AT 12"
LIMITED TO TRACKS, CLIPS, WEB STIFFENERS, ANCHORS, FASTENING DEVICES, ETC) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN
33. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED BY THE O.C., MINIMUM. MORE STRINGENT REQUIREMENTS MAY OCCUR ELSEWHERE.
RESILIENT CLIPS, AND OTHER ACCESSORIES REQUIRED FOR A COMPLETE AND PROPER TEN FEET OF ANY POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE
PREMISES' ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, AN
GENERAL NOTES
1. AT FASCIAS AND WALL PANELS SHEET METAL SHALL BE GALVANIZED, BONDERIZED, OR EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED.
ON-SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL OR CRACK UNDER SCREEDING OR TROWELING. TRIM, SLICE, OR SCRAPE EXCESS PAINTED, AND 20 GA. MIN. UNLESS OTHERWISE NOTED. 'GSM', WHERE CALLED OUT ON
MATERIAL TO TRUE LINE AND GRADE AND REMOVE THE PLACING GUIDES. A NATURAL 7. EXIT SIGNS ILLUMINATED BY AN EXTERNAL SOURCE SHALL HAVE AN INTENSITY OF NOT
BE IN ACCORDANCE WITH 2016 CBC SECTION 2702. PLANS/ELEVATIONS, SHALL MEAN GALVANIZED SHEET METAL THAT IS CONCEALED OR
ROD FINISH SHALL CONSIST OF THE REMOVAL, BY FLOATING, OF THE IMPRESSIONS LEFT LESS THAN 5 FOOT CANDLES (54 LUX).
35. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL EXPOSED PAINTED BONDERIZED SHEET METAL. (AT ALL LOCATIONS WHERE GSM IS
AFTER THE GUIDE STRIPS OR GROUND WIRES HAVE BEEN REMOVED. PROVIDE A FLOAT EXPOSED OR PAINTED THE GSM SHALL BE BONDERIZED META LOR ZINC ALLOY) SEE 8. INTERNALLY ILLUMINATED SIGNS SHALL BE LISTED AND LABELED AND SHALL BE
ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOT-CANDLE AND A MINIMUM AT
FINISH RESULTING FROM FLOATING THE NATURAL ROD FINISH WITH A WOOD OR ELEVATIONS. INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND SECTION
ANY POINT OF 0.1 FOOT-CANDLE MEASURED ALONG THE PATH OF EGRESS AT FLOOR
RUBBER FLOAT. POURED-IN-PLACE EXPOSED CONCRETE WALLS (WHERE OCCURS): 2702.
LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOT-CANDLE
HORIZONTAL CONTROL:
INTERIOR GYPSUM BOARD
PROVIDE FORM-FACING PANELS THAT WILL PROVIDE CONTINUOUS, TRUE, AND SMOOTH
AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOT-CANDLE AT THE END OF THE 9. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. (1011.3)
VERTICAL CONTROL:
CONCRETE SURFACES. FURNISH FORMS IN LARGEST PRACTICABLE SIZES TO MINIMIZE 1. SHALL BE "TYPE "X" 5/8" THICKNESS IN ALL AREAS, U.N.O., TAPED AND FINISHED SMOOTH
EMERGENCY LIGHTING TIME DURATION. A MAXIMUM-TO-MINIMUM ILLUMINATION
G NUMBER OF JOINTS. FORMS SHALL BE EXTERIOR-GRADE PLYWOOD PANELS SUITABLE FOR WALL PAINT. ALL GYPSUM BOARD SHALL BE INSTALLED USING FLATHEAD DRYWALL 10. EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL
UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED PER CBC SECT 1006.4.
FOR CONCRETE FORMS, HIGH-DENSITY OVERLAY, CLASS I OR BETTER. FORMS FOR SCREWS ONLY. PROVIDE AN ILLUMINATION OF NOT LESS THAN 90 MIN. IN CASE OF PRIMARY POWER
SHEET TITLE:
36. EMERGENCY RESPONDER SAFETY FEATURES PER 2019 CBC SECT 914 AND 915: CYLINDRICAL COLUMNS SHALL BE METAL, GLASS-FIBER-REINFORCED PLASTIC, PAPER LOSS (1011.6.3).
ADDRESS:
PROJECT:
EXTERIOR AND INTERIOR ACCESS TO VERTICAL SHAFTS OR HOISTWAYS SHALL BE 2. WHERE A FIRE DAMPER OR MECHANICAL OR PLUMBING EQUIPMENT REQUIRING ACCESS
OR FIBER TUBES THAT WILL PRODUCE SURFACES NOT EXCEEDING SPECIFIED
IDENTIFIED WITH THE WORD 'SHAFTWAY' IN RED LETTERS, 6 INCHES HIGH, ON A WHITE OCCURS, CONTRACTOR SHALL PROVIDE A GYP. BRD. ACCESS PANEL THAT IS 2'-0" X 2'-0". 11. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE
FORMWARK CLASS. PROVIDE UNITS WITH SUFFICIENT WALL THICKNESS TO RESIST
BACKGROUND, PLACED SO AS TO BE READILY DISCERNIBLE, UNLESS THE OPENING IS METAL SUSPENSION SYSTEMS FOR LAY IN PANEL CEILINGS USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. SEE 1008.1.9 FOR EXCEPTIONS.
PLASTIC CONCRETE LOADS WITHOUT DETRIMENTAL DEFORMATION. CHAMFER STRIPS
READILY DISCERNIBLE BY THE CONSTRUCTION OR ARRANGEMENT OF THE OPENING. SHALL BE WOOD, METAL OR RUBBER STRIPS, KERFED FOR EASE OF REMOVAL, 12. DOOR HANDLES, LOCK AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT A MIN.
1. 12 GA. (MIN.) HANGER WIRES MAY BE USED FOR UP TO AND INCLUDING 4'-0" X 4'-0" GRID
FIRE EQUIPMENT ROOMS SHALL BE IDENTIFIED FOR THE USE OF THE FIRE DEPARTMENT THREE-QUARTER INCH X THREE-QUARTER INCH. THE FORM-RELEASE AGENT SHALL NOT 34" AND A MAX. 48" ABOVE THE FINISHED FLOOR.
SPACING AND SHALL BE ATTACHED TO MAIN RUNNERS.
BY:
13. OMIT.
CONSTRUCTED OF DURABLE MATERIALS, PERMANENTLY INSTALLED AND READILY IMPAIR SUBSEQUENT TREATMENTS OF CONCRETE SURFACES. FORM TIES SHALL BE 2. PROVIDE 12 GA. HANGER WIRES AT ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN
VISIBLE. ENERGENCY RESPONDER RADIO COVERAGE SHALL BE PROVIDED IN ALL NEW FACTORY-FABRICATED, REMOVABLE OR SNAP-OFF METAL OR GLASS-FIBER-REINFORCED EIGHT INCHES (8") OF THE SUPPORT OR WITHIN ONE-FOURTH (1/4) OF THE END TEE, 14. ALL EGRESS DOOR OPERATION SHALL ALSO COMPLY WITH SECTION 1008.1.9-1008.1.9.12.
DATE:
CIP NO.
BUILDINGS IN ACCORDANCE WITH SECT 510 OF THE 2017 CFC. PLASTIC FORM TIES DESIGNED TO RESIST LATERAL PRESSURE OF FRESH CONCRETE ON WHICHEVER IS LEAST, FOR THE PERIMETER OF THE CEILING AREA.
15. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT
ENERGY FORMS AND TO PREVENT SPALLING OF CONCRETE ON REMOVAL. FURNISH UNITS THAT 3. PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS
F WILL LEAVE NO CORRODIBLE METAL CLOSER THAN 1.5 INCHES TO THE PLANE OF TO TYPICAL HANGER SPACING. PROVIDE ADDITIONAL HANGERS, STRUTS OR BRACES AS
ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED.
1. THE BUILDING SHALL MEET THE REQUIREMENTS OF 2019 CALIFORNIA ENERGY CODE: EXPOSED CONCRETE SURFACE. TIES SHALL LEAVE HOLES NO LARGER THAN 1 INCH I 16. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1-FOOT CANDLE
REQUIRED AT ALL CEILING BREAKS, SOFFITS OR DISCONTINUOUS AREAS. HANGER
TITLE 24, CEC, PART 6, SUBCH. 1 THROUGH 6 FOR COMMERCIAL OCCUPANCIES. DIAMETER. CONCRETE SLABS (EXPOSED, WHERE OCCURS): SHALL BE STABLE, FIRM AT THE WALKING SURFACE.
WIRES THAT ARE MORE THAN 1 IN 6 OUT OF PLUMB ARE TO HAVE COUNTER-SLOPING
2. INSULATION INSTALLER SHALL POST IN A CONSPICUOUS LOCATION IN THE BUILDING A AND SLIP RESISTANT. CONCRETE SHALL HAVE A HEAVY BROOM FINISH ON VEHICULAR WIRES. 17. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE
CERTIFICATE SIGNED BY THE BUILDER AND INSTALLER STATING THAT THE INSTALLATION DRIVES SLOPED OVER 10%. CONCRETE SHALL BE SLIP RESISTANT AT SLOPES EQUAL TO PROVIDED BY THE PREMISES' ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY
4. CEILING GRID MEMBERS MAY BE ATTACHED TO NOT MORE THAN TWO (2) ADJACENT
CONFORMS WITH THE REQUIREMENTS OF TITLE 24, PART 6, SUBCH.2. SECT. 118 AND OR GREATER THAN 6% AND HAVE A MEDIUM SALTED FINISH WHERE SLOPE IS LESS THAN FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE THE
WALLS. CEILING GRID MEMBERS SHALL BE AT LEAST 1/2" FREE OF OTHER WALLS. IF
THAT THE MATERIALS INSTALLED CONFORM WITH THE REQUIREMENTS OF TITLE 20, 6%. FOLLOWING AREAS:
WALLS RUN DIAGONALLY TO CEILING GRID SYSTEM RUNNERS, ONE END OF MAIN AND
CHAPTER 2, SUBCHAPTER 4, ARTICLE 3. INSULATION/ SEALANT/ THERMAL REQUIREMENTS CROSS RUNNERS SHOULD BE FREE, AND A MINIMUM OF 1/2" CLEAR OF WALL. A. AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND SPACES THAT REQUIRE
3. ALL INSULATION MATERIALS SHALL BE INSTALLED AND CERTIFIED AS PER 2017 CEC SECT TWO OR MORE MEANS OF EGRESS.
1. BATT INSULATION OF R-VALUE R-21 MIN. SHALL BE PROVIDED IN ALL EXTERIOR FRAME 5. AT THE PERIMETER OF THE CEILING AREA WHERE MAIN OR CROSS RUNNERS ARE NOT
118. INSULATION SHALL BE FREE OF UREA-FORMALDEHYDE. CONCRETE SLAB FLOORS WALLS; R-VALUE R-30 AT THE UNDERSIDE OF ROOF PLYWOOD SHEATHING, IF WOOD CONNECTED TO THE ADJACENT WALL, PROVIDE INTERCONNECTION BETWEEN THE B. CORRIDORS, EXIT ENCLOSURES AND EXIT PASSAGEWAYS IN BUILDINGS REQUIRED TO
SHALL BE INSULATED PER SECT 118, (G) AND OTHER APPLICABLE SECTIONS. TRUSSES ARE UTILIZED FOR FLOOR OR ROOF STRUCTURE, PROVIDE BLOWN-IN RUNNERS AT THE FREE END TO PREVENT LATERAL SPREADING. A METAL STRUT OR A 16 HAVE TWO OR MORE EXITS.
E 4. DOORS AND WINDOWS BETWEEN CONDITIONED AND OUTSIDE OF CONDITIONED SPACES INSULATION TO PROPERLY FILL ALL AIR GAPS. GA. WIRE WITH A POSITIVE MECHANICAL CONNECTION TO THE RUNNER MAY BE USED. C. EXTERIOR EGRESS COMPONENTS AT OTHER THAN THE LEVEL OF EXIT DISCHARGE UNTIL
SHALL BE FULLY WEATHER-STRIPPED. 2. INSULATION SHALL BE INSTALLED SO THAT BATTS ARE NOT COMPRESSED (CUT BATTS WHERE THE PERPENDICULAR DISTANCE FROM THE WALL TO THE FIRST PARALLEL EXIT DISCHARGE IS ACCOMPLISHED FOR BUILDINGS REQURIED TO HAVE TWO OR MORE
TO FIT AROUND ELECTRICAL AND PLUMBING IN WALL CAVITY). THERE SHALL BE NO RUNNER IS 12" OR LESS, THIS INTERLOCK IS NOT REQUIRED. EXITS.
5. MANUFACTURED DOORS AND WINDOWS SHALL BE CERTIFIED AND LABELED IN
COMPLIANCE WITH THE APPROPRIATE INFILTRATION STANDARDS. GAPS OR VOIDS IN WALL CAVITY. EXTERIOR SHEATHING SHALL NOT BE VISIBLE 6. PROVIDE BRACING ASSEMBLIES CONSISTING OF A COMPRESSION STRUT AND FOUR (4) D. INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN SECTION 1027.1, IN BUILDING
THROUGH INSULATION MATERIAL..
REVISIONS:
12 GA. SPLAYED BRACING WIRES ORIENTED 90 DEGREES FROM EACH OTHER AT THE REQUIRED TO HAVE TWO OR MORE EXITS.
6. CAULK, GASKET, WEATHER-STRIP OR OTHERWISE SEAL PLUMBING AND ELECTRICAL
PENETRATIONS, ALL WINDOW AND DOOR FRAMES, BETWEEN WALL SOLEPLATES AND 3. PROVIDE ATTIC EAVE BAFFLES (WHEREVER SOFFIT VENTS ARE LOCATED) THAT EXTEND FOLLOWING SPACING: E. EXTERIOR LANDINGS, AS REQUIRED BY SECTION 1008.1.6, FOR EXIT DISCHARGE
FLOOR AND ALL OTHER OPENINGS IN THE BUILDING ENVELOPE THAT ARE POTENTIAL OVER THE TOP OF ATTIC INSULATION TO SERVE AS AN AIR BARRIER TO PREVENT WIND A) FOR SCHOOL BUILDINGS, PLACE BRACING ASSEMBLIES AT A SPACING NOT MORE THAN DOORWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS.
INDEX NO.
SOURCES OF AIR LEAKAGE. FROM MOVING INSULATION. 12' BY 12' ON CENTER. 18. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT
NO.
7. DUCTS SHALL BE CONSTRUCTED, INSTALLED AND INSULATED PER UMC LATEST EDITION. 4. OMIT. B) FOR ESSENTIAL SERVICES BUILDINGS, PLACE BRACING ASSEMBLIES NOT MORE THAN 8' LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT
ALL DUCTS SHALL BE WRAPPED TO PREVENT DUST FROM GETTING INSIDE PRIOR TO 5. SKYLIGHT SHAFTS PROTRUDING THROUGH CEILING AND AN UNCONDITIONED SPACE BY 12' ON CENTER. OR AN ON-SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM
CLOSE UP. SHALL BE INSULATED AND SHALL HAVE AN AIR BARRIER ON EXT. SIDE OF SHAFT WALL. C) PROVIDE BRACING ASSEMBLIES AT LOCATIONS NOT MORE THAN HALF (1/2) THE SHALL BE IN ACCORDANCE WITH SECTION 2702.
D 8. ALL OPENINGS (DOORS AND WINDOWS) SHALL BE PROPERLY CERTIFIED, AND LABELED. THIS INSULATION SHALL BE CONTINUOUS WITH CLG/ROOF INSULATION. SPACINGS GIVEN ABOVE, FROM EACH PERIMETER WALL AND AT THE EDGE OF VERTICAL 19. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL
CITY ENGINEER
DATE:
6. PROVIDE WOOD BLOCKING OR SOLID AIR BARRIER AT THE INTERSECTION BETWEEN CEILING OFFSETS. THE SLOPE OF THESE WIRES SHALL NOT EXCEED 45 DEGREES FROM ILLUMINATION THAT IS AT LEAST AVERAGE OF 1-FOOT CANDLE (11 LUX) AND A MIN. AT
9. BACKDRAFT DAMPERS FOR ALL EXHAUST AND FAN SYSTEMS SHALL BE PROVIDED.
CONDITIONED SPACE AND AN EXTERIOR ROOF/SOFFIT SO THAT AIR CANNOT EASILY THE PLANE OF THE CEILING AND SHALL BE TAUT. SPLICES IN BRACING WIRES ARE NOT ANY POINT OF 0.1 FOOT-CANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT
10. ALL STEAM AND STEAM CONDENSATE RETURN PIPING SHALL BE INSULATED AS PASS THROUGH INSULATION FROM OUTSIDE TO INSIDE. TO BE PERMITTED WITHOUT SPECIAL DSA APPROVAL. FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6
REQUIRED BY THE PLUMBING DIVISION. D) SUSPENDED ACOUSTICAL CEILING SYSTEMS WITH A CEILING AREA OF 144 SQUARE FEET FOOT-CANDLE AVERAGE AND A MIN. AT ANY POINT OF 0.06 FOOT-CANDLE AT THE END
7. OMIT. OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM-TO-MINIMUM ILLUMINATION
11. ROOFING PRODUCTS THERMAL EMITTANCE AND 3-YEAR AGED SOLAR REFLECTANCE OR LESS, AND FIRE RATED SUSPENDED ACOUSTICAL CEILING SYSTEMS WITH A CEILING
8. ALL DUCT SHAFTS, PIPING SHAFTS, FLUE SHAFTS & PENETRATIONS SHALL BE FULLY AREA OF 96 SQUARE FEET OR LESS, SURROUNDED BY WALLS WHICH CONNECT UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED.
SHALL BE CERTIFIED AND LABELED OR SHALL MEET DEFAULT VALUES AS SPECIFIED IN
TITLE 24, CEC, PART 6, SUBCH. 2, SECT. 118, (h) (i) 1. SEALED BETWEEN CONDITIONED & UNCONDITIONED SPACES. USE SOLID BLOCKING OR DIRECTLY TO THE STRUCTURE ABOVE, DO NOT REQUIRE BRACING ASSEMBLIES WHEN 20. TOILET ROOM FLOORS SHALL HAVE A SMOOTH, HARD NON-ABSORBENT SURFACE SUCH
FLASHING & SEAL ANY REMAINING GAPS WITH CAULK OR FOAM. ATTACHED TO TWO ADJACENT WALLS. AS PORTLAND CEMENT, CERAMIC TILE OR OTHER APPROVED MATERIAL THAT EXTENDS
12. FOLLOW MANDATORY REQUIREMENTS FOR LIGHITNG CONTROL DEVICES, BALLASTS AND UPWARD ONTO THE WALLS AT LEAST 4' (1210.2.1)
9. ATTIC ACCESS PANELS (OR CEILIING PANELS) SHALL BE FULLY GASKETED AND 7. FASTEN HANGER WIRES WITH NOT LESS THAN THREE (3) TIGHT TURNS. FASTEN
LUMINAIRES PER 2017 CEC SECT 119.
INSULATED (MIN R-5). BRACING WIRES WITH FOUR (4) TIGHT TURNS. MAKE ALL TIGHT TURNS WITHIN A 21. WALLS WITHIN 2 FEET OF THE FRONT AND SIDES OF URINALS AND WATER CLOSETS
MISCELLANEOUS
C 10. WHERE DROPPED CEILINGS OR SOFFITS OCCUR AT EXTERIOR WALLS, PROVIDE AN AIR DISTANCE OF 1 1/2" INCHES. HANGER OR BRACING WIRE ANCHORS TO THE STRUCTURE SHALL HAVE A SMOOTH, HARD NON-ABSORBENT SURFACE OF PORTLAND CEMENT,
1. PROVIDE ULTRA LOW FLOW WATER CLOSETS THROUGHOUT. BARRIER ALIGNED WITH FLR./ CLG. INSULATION AND EXT. WALL INSULATION. SHOULD BE INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE WIRE ALIGNS CONCRETE, CERAMIC TILE, OR OTHER SMOOTH, HARD NON-ABSORBENT SURFACE TO A
DESIGN GROUP
AS CLOSELY AS POSSIBLE WITH THE DIRECTION OF THE FORCES ACTING ON THE WIRE. HEIGHT OF 4 FEET AND EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN
2. GLASS THICKNESS SHALL BE NOT LESS THAN THAT DETERMINED BY TABLE 2403.2.1 2017 WOOD FRAMING REQUIREMENTS/WHERE OCCURS
* NOTE: WIRE TURNS MADE BY MACHINE WHERE BOTH STRANDS HAVE BEEN DEFORMED SUCH WALLS SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE.
CBC. ALL GLASS AND GLAZING SHALL MEET THE GUIDELINES AS OUTLINED IN CHAPTER
1. ALL NEW EXTERIOR WALL, FLOOR, AND ROOF FRAMING SHALL BE FSC CERTIFIED. OR BENT IN WRAPPING CAN WAIVE THE 1 1/2" REQUIREMENT,BUT THE NUMBER OF (1210.2.2)
24 2017 CBC. GREATER REQUIREMENTS MAY BE APPLICABLE PER THESE
CONSTRUCTION DOCUMENTS. 2. PROVIDE SILL SEAL (BY DOW OR EQUAL) BELOW BOTTOM PLATE OF ALL EXT. WALLS. TURNS SHOULD BE MAINTAINED, AND BE AS TIGHT AS POSSIBLE. 22. WATER-RESISTANT FIRE-RATED 'DENS-SHIELD' OR EQUAL BACKING BOARD SHALL BE
3. ALL GLASS DOORS SHALL HAVE FULLY TEMPERED GLASS AND ALL GLAZING WITHIN 18" 8. SEPERATE ALL CEILING HANGING AND BRACING WIRES AT LEAST SIX INCHES (6") FROM USED AS A BASE FOR TILE IN WATER CLOSET COMPARTMENT WALLS OR BATHROOMS.
3. PRESERVATIVE-TREATED WOOD DUE TO HIGH PROBABILITY OF TERMITE INFESTATION.
OF A FLOOR SHALL BE TEMPERED. ALL UNBRACED DUCTS, PIPES, CONDUIT, ETC. IT IS ACCEPTABLE TO ATTACH WATER RESISTANT GYPSUM BOARD SHALL NOT BE USED IN THE FOLLOWING LOCATIONS:
4. STUD WALLS SHALL BEAR ON A 2" THICK OR LARGER BOTTOM PLATE (ACTUAL 1 1/2" LIGHTWEIGHT ITEMS, SUCH AS SINGLE ELECTRICAL CONDUIT NOT EXCEEDING 3/4" SECTION 2506.1
4. GLAZING ADJACENT TO A DOOR AND WITHIN THE SAME WALL PLANE AS THE DOOR
THICK) OF A WIDTH AT LEAST EQUAL TO THE WIDTH OF THE STUDS. STUDS SHALL BE NOMINAL DIAMETER. A. OVER A VAPOR RETARDER.
APPROVED BY:
C. ON CEILINGS WHERE FRAME SPACING EXCEEDS 12 INCHES O.C. FOR 1/2" THICK OR MORE
DESIGNED BY:
FINISHED FLOOR LEVEL OR WALKING SURFACE WITHIN 36" OF SUCH GLAZING SHALL BE WIRES, 1 OUT OF 2 MUST BE FIELD TESTED FOR 440 LBS. IN TENSION. SHOT -IN ANCHORS
CHECKED BY:
6. NON-BEARING WALLS AND PARTITIONS SHALL HAVE NO LESS THAN A SINGLE TOP PLATE
THAN 16 INCHES O.C. FOR 5/8" THICK.
DRAWN BY:
IN CONCRETE ARE NOT PERMITTED FOR BRACING WIRES.
ENGINEER:
TEMPERED. INSTALLED TO PROVIDE OVERLAPPING AT CORNERS AND AT INTERSECTIONS W/ OTHER
WALLS AND PARTITIONS. 10. ATTACH ALL LIGHT FIXTURES AND CEILING MOUNTED AIR TERMINALS OR SERVICES, TO 23. NOTICE OF CEQA EXEMPTION LETTER IS ATTACHED ON SHEET A0.32 - A0.33,
5. ACOUSTIC INSULATION SHALL BE CONTINUOUS AT ALL TOILET ROOMS AND PLUMBING
THE CEILING GRID RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT CONTRACTOR'S SCOPE INCLUDES AND SHALL FOLLOW ALL REQUIREMENTS STATED IN
WALLS. 7. STUD WALLS SHALL BE BRACED PER 2017 CBC 2308.9.3.
OF THE FIXTURES. SCREWS OR APPROVED FASTENERS ARE REQUIRED. THIS LETTER.
6. THERMAL INSUL. SHALL MATCH THE VALUES STATED IN THE DRAWINGS & ENERGY 8. ALL OPENINGS IN INTERIOR PARTITIONS SHALL HAVE HEADERS PER 2017 CBC SECT
CALCULATION REPORT & SHALL BE CONTINUOUS AT ALL EXTERIOR CAVITY WALLS & 2308.9.6 AND 2308.9.7.
SOFFITS. ALL REQUIREMENTS OF TITLE 24 SHALL BE COMPLIED WITH. WORK ORDER NO.
9. PIPES IN WALL SHALL MEET 2017 CBC, 2308.9.8.
7. PHONE OUTLETS SHALL BE PROVIDED PER DRAWINGS. END OF GENERAL NOTES. E170121B
WOOD SHEATHING REQUIREMENTS / WHERE OCCURS
(DESIGN STAGE ONLY)
A 1. ALL WALL SHEATHING SHALL EITHER HAVE FSC CERTIFICATION OR A RECYCLED SHEET NAME
REVISION DATES
A0.11
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A011_24X36.DWG 12/3/2021 9:06 AM
REVISION DATES
(DESIGN STAGE ONLY)
G
K
D
H
A
E
F
1
1
2
2
3
3
4
4
5
5
6
6
7
7
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A012_24X36.DWG 12/3/2021 9:06 AM
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
PROJECT:
DRAWN BY:
X
APPROVED BY:
18210 SHERMAN WAY, RESEDA CA 91335
SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
J
A0.12 GRN 1
A1.00, A8.34 7 SPACES
N/A 2 PARKING SPACES PROVIDED
A1.00 2 SPACES
10/31/2023
A1.00, A8.34 1 SPACE
A0.15 SEE NOTE
A1.00 SITE PLAN
L0.00 HARDSCAPE CALCS.
A0.13 GRN 15 #7
HORIZONTAL CONTROL:
A0.13 GRN 15 #8
VERTICAL CONTROL:
A0.13 GRN 15 #10
G A1.10, A4.00 4'-0" MIN.
SHEET TITLE:
A0.13 GRN 15 #11
ADDRESS:
PROJECT:
A0.13 GRN 15 #12
A0.13 GRN 15 #13
CIP NO.
F
REVISIONS:
A0.14 NOTE
A0.14 NOTE
INDEX NO.
A0.14 NOTE
NO.
A0.14 NOTE
N/A >10,000 SF
D
CITY ENGINEER
DATE:
N/A NO FP
A0.13 GRN 15 #17
A0.13 GRN 15 #18
C GRN 15 #19
A0.13
DESIGN GROUP
GRN 15 #20
APPROVED BY:
DESIGNED BY:
CHECKED BY:
A0.13 GRN 15 #29
DRAWN BY:
ENGINEER:
N/A PROJECT EXEMPT,
SPORTS ARENA
A SHEET NAME
REVISION DATES
A0.13
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A013_24X36.DWG 12/3/2021 9:06 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
10/31/2023
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G
SHEET TITLE:
ADDRESS:
PROJECT:
DEPARTMENT OF PUBLIC WORKS
BY:
DATE:
CIP NO.
F
REVISIONS:
THE TRAINING FOR THE APPROPRIATE MAINTENANCE STAFF FOR EACH EQUIPMENT TYPE
AND/OR SYSTEM SHALL BE DOCUMENTED IN THE COMMISSIONING REPORT. (5.410.2.5.2)
INDEX NO.
FORM GRN 25 SHALL BE COMPLETED AND READILY AVAILABLE TO THE FIELD INSPECTOR
NO.
PRIOR TO FINAL APPROVAL.
CITY ENGINEER
INSPECTOR PRIOR TO THE FINAL APPROVAL. (5.410.2.6. 5.410.4.4)
DATE:
THE THIRD PARTY COMMISSIONING AGENT'S INFORMATION IS ON THE COVER SHEET AND HAS
BEEN HIRED BY THE OWNER.
DESIGN GROUP
CITY OF LOS ANGELES
B
APPROVED BY:
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
WORK ORDER NO.
E170121B
(DESIGN STAGE ONLY)
A SHEET NAME
REVISION DATES
A0.14
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A014_24X36.DWG 12/3/2021 9:06 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
2019 CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 3 GREEN BUILDING
MANDATORY REQUIREMENTS
NOTE: PROJECTS THAT (1) DISTURB ONE ACRE OR MORE OF LAND,
OR (2) DISTURB LESS THAN ONE ACRE OF LAND, BUT ARE PART OF
3. THE RACEWAY SHALL NOT BE LESS THAN TRADE SIZE 1." 1. SEE ALSO CALIFORNIA BUILDING CODE, CHAPTER 12, SECTION
1205.7 FOR COLLEGE CAMPUS LIGHTING REQUIREMENTS FOR
2. WHERE SEPARATE SUBMETERS FOR INDIVIDUAL BUILDING
TENANTS ARE UNFEASIBLE, FOR WATER SUPPLIED TO THE
ENGINEERING
4. THE RACEWAY SHALL ORIGINATE AT A SERVICE PANEL OR A
A LARGER COMMON PLAN OF DEVELOPMENT OR SALE MUST PARKING FACILITIES AND WALKWAYS. FOLLOWING SUBSYSTEMS:
SUBPANEL SERVING THE AREA, AND SHALL TERMINATE IN CLOSE
COMPLY WITH THE POSTCONSTRUCTION REQUIREMENTS 2. REFER TO CHAPTER 8 (COMPLIANCE FORMS, WORKSHEETS AND A. MAKEUP WATER FOR COOLING TOWERS WHERE FLOW THROUGH
PROXIMITY TO THE PROPOSED LOCATION OF THE CHARGING
SECTION 301 GENERAL DETAILED IN THE APPLICABLE NATIONAL POLLUTANT DISCHARGE IS GREATER THAN 500 GPM (30 L/S).
ELIMINATION SYSTEM (NPDES) GENERAL PERMIT FOR
K STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION
ENCLOSURE OR EQUIVALENT. ENERGY CODE TABLES 130.2-A AND 130.2-B.
B. MAKEUP WATER FOR EVAPORATIVE COOLERS GREATER THAN 6
301.1 301.1 THIS BUILDING SHALL FOLLOW ALL NON - RESIDENTIAL AND LAND DISTURBANCE ACTIVITIES ISSUED BY THE STATE 5. 3. REFER TO THE CALIFORNIA ENERGY CODE FOR REQUIREMENTS GPM (0.04 L/S).
GREEN BUILDING MANADTORY MEASURES AND ADDITIONAL CITY WATER RESOURCES CONTROL BOARD OR THE LAHONTAN CAPACITY TO ACCOMMODATE A MINIMUM 40- AMPERE DEDICATED FOR ADDITIONS AND ALTERATIONS.
C. STEAM AND HOT-WATER BOILERS WITH ENERGY INPUT MORE
OF LOS ANGELES REQUIREMENTS. SEE SHEETS A0.12 - A0.17 FOR REGIONAL WATER QUALITY CONTROL BOARD (FOR PROJECTS IN BRANCH CIRCUIT FOR THE FUTURE INSTALLATION OF THE EVSE. 5.106.10 GRADING AND PAVING. CONSTRUCTION PLANS SHALL INDICATE THAN 500,000 BTU/H (147 KW).
MORE INFORMATION. CITY OF LOS ANGELES REQUIREMENTS MAY THE LAKE TAHOE HYDROLOGIC UNIT). 5.106.5.3.2 MULTIPLE CHARGING SPACE REQUIREMENTS. [N] WHEN MULTIPLE HOW SITE GRADING OR A DRAINAGE SYSTEM WILL MANAGE ALL
BE MORE RESTRICTIVE. THE NPDES PERMITS REQUIRE POSTCONSTRUCTION RUNOFF CHARGING SPACES ARE REQUIRED PER TABLE 5.106.5.3.3 SURFACE WATER FLOWS TO KEEP WATER FROM ENTERING 5.303.1.2 EXCESS CONSUMPTION. A SEPARATE SUBMETER OR METERING
(POST-PROJECT HYDROLOGY) TO MATCH THE PRECONSTRUCTION RACEWAY(S) IS/ARE REQUIRED TO BE INSTALLED AT THE TIME OF BUILDINGS. EXAMPLES OF METHODS TO MANAGE SURFACE DEVICE SHALL BE PROVIDED FOR ANY TENANT WITHIN A NEW
RUNOFF (PRE-PROJECT HYDROLOGY) WITH THE INSTALLATION OF CONSTRUCTION AND SHALL BE INSTALLED IN ACCORDANCE WITH WATER INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: BUILDING OR WITHIN AN ADDITION THAT IS PROJECTED TO
SECTION 302 MIXED OCCUPANCY BUILDINGS POSTCONSTRUCTION STORM WATER MANAGEMENT MEASURES. THE CALIFORNIA ELECTRICAL CODE. CONSTRUCTION PLANS AND i SWALES
THE NPDES PERMITS EMPHASIZE RUNOFF REDUCTION THROUGH SPECIFICATIONS SHALL INCLUDE, BUT ARE NOT LIMITED TO, THE 5.303.2 RESERVED
ON-SITE STORMWATER USE, INTERCEPTION, FOLLOWING: ii WATER COLLECTION AND DISPOSAL SYSTEMS.
302.1 MIXED OCCUPANCY BUILDINGS: IN MIXED OCCUPANCY EVAPOTRANSPIRATION, AND INFILTRATION THROUGH 5.303.3 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS.
1. THE TYPE AND LOCATION OF THE EVSE. iii FRENCH DRAINS.
J BUILDINGS, EACH PORTION OF A BUILDING SHALL COMPLY WITH NONSTRUCTURAL CONTROLS, SUCH AS LOW IMPACT PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND
THE SPECIFIC GREEN BUILDING MEASURES APPLICABLE TO EACH DEVELOPMENT (LID) PRACTICES, AND CONSERVATION DESIGN 2. THE RACEWAY(S) SHALL ORIGINATE AT A SERVICE PANEL OR A iv WATER RETENTION GARDENS. FITTINGS (FAUCETS AND SHOWERHEADS) SHALL COMPLY WITH
SPECIFIC OCCUPANCY. MEASURES. STORMWATER VOLUME THAT CANNOT BE SUBPANEL(S) SERVING THE AREA, AND SHALL TERMINATE IN THE FOLLOWING:
v OTHER WATER MEASURES WHICH KEEP SURFACE WATER AWAY
ADDRESSED USING NONSTRUCTURAL PRACTICES IS REQUIRED CLOSE PROXIMITY TO THE PROPOSED LOCATION OF THE 5.303.1 WATER CLOSETS. THE EFFECTIVE FLUSH VOLUME OF ALL WATER
TO BE CAPTURED IN STRUCTURAL PRACTICES AND BE APPROVED FROM BUILDINGS AND AID IN FEOUNDWATER RECHARGE.
CHARGING EQUIPMENT AND INTO LISTED SUITABLE CABINET(S), CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH.
BY THE ENFORCING AGENCY. BOX(ES), ENCLOSURE(S) OR EQUIVALENT. EXCEPTION: ADDITIONS AND ALTERATIONS NOT ALTERING THE TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE
REFER TO THE CURRENT APPLICABLE PERMITS ON THE STATE DRAINAGE PATH. 10/31/2023
NON-RESIDENTIAL MANDATORY MEASURES, CHAPTER 5 PERFORMANCE CRITERIA OF THE U.S. EPA WATERSENSE
WATER RESOURCES CONTROL BOARD WEBSITE AT: 3.
5.106.12 SHADE TREES. [DSA-SS] NOT APPLICABLE TO THIS PROJECT. SPECIFICATION FOR TANK-TYPE TOILETS.
WWW.WATERBOARDS.CA.GOV/CONSTRUCTION STORMWATER. BRANCH CIRCUITS.
5.106.12.2 NOTE: THE EFFECTIVE FLUSH VOLUME OF DUAL FLUSH TOILETS IS
CONSIDERATION TO THE STORMWATER RUNOFF MANAGEMENT 4. ELECTRICAL CALCULATIONS SHALL SUBSTANTIATE THE DESIGN
DIVISION 5.1 PLANNING AND DESIGN CONTAINER SIZE OR EQUAL SHALL BE INSTALLED TO PROVIDE DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO
MEASURES SHOULD BE GIVEN DURING THE INITIAL DESIGN OF THE ELECTRICAL SYSTEM, TO INCLUDE THE RATING OF
SHADE OF 20 PERCENT OF THE LANDSCAPE AREA WITHIN 15 REDUCED FLUSHES AND ONE FULL FLUSH.
PROCESS FOR APPROPRIATE INTEGRATION INTO SITE
DEVELOPMENT. AND HAVE SUFFICIENT CAPACITY TO SIMULTANEOUSLY CHARGE YEARS. 5.303.3.2 URINALS
I 5.101.1 SCOPE. THE PROVISIONS OF THIS CHAPTER OUTLINE PLANNING,
5.106.4 BICYCLE PARKING. FOR BUILDINGS WITHIN THE AUTHORITY OF ALL REQUIRED EVS AT ITS FULL RATED AMPERAGE. EXCEPTION: PLAYFIELDS FOR ORGANIZED SPORT ACTIVITY ARE
DESIGN AND DEVELOPMENT METHODS THAT INCLUDE 5.303.3.2.1. WALL-MOUNTED URINALS. THE EFFECTIVE FLUSH VOLUME OF
ENVIRONMENTALLY RESPONSIBLE SITE SELECTION, BUILDING CALIFORNIA BUILDING STANDARDS COMMISSION AS SPECIFIED IN 5. NOT INCLUDED IN THE TOTAL AREA CALCULATION. WALL-MOUNTED URINALS SHALL NOT EXCEED 0.125 GALLONS PER
DESIGN, BUILDING SITING AND DEVELOPMENT TO PROTECT, SECTION L 03, COMPLY WITH SECTION 5.106.4.1. FOR BUILDINGS 5.106.12.3 HARDSCAPE AREAS. SHADE TREE PLANTINGS, MINIMUM NO. 10 FLUSH.
HORIZONTAL CONTROL:
TENANT-OCCUPANT VEHICULAR PARKING SPACES WITH A SHOWERHEAD.
TABLE 5.106.5.3.3
5.103 SITE SELECTION (RESERVED)
VERTICAL CONTROL:
MINIMUM OF ONE BICYCLE PARKING FACILITY. 5.303.3.4. FAUCETS AND FOUNTAINS.
G 5.106.4.1.3. FOR ADDITIONS OR ALTERATIONS THAT ADD 10 OR MORE 5.303.3.4.1 NONRESIDENTIAL LAVATORY FAUCETS. LAVATORY FAUCETS
SHEET TITLE:
5.104 SITE PRESERVATION (RESERVED) TENANT-OCCUPANT VEHICULAR PARKING SPACES, PROVIDE SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 0.5
ADDRESS:
SECURE BICYCLE PARKING FOR 5 PERCENT OF THE TENANT
PROJECT:
GALLONS PER MINUTE AT 60 PSI.
VEHICULAR PARKING SPACES BEING ADDED, WITH A MINIMUM OF
5.303.3.4.2 KITCHEN FAUCETS. KITCHEN FAUCETS SHALL HAVE A MAXIMUM
5.105 DECONSTRUCTION AND REUSE OF EXISTING STRUCTURES (RESERVED) ONE BICYCLE PARKING FACILITY.
FLOW RATE OF NOT MORE THAN 1.8 GALLONS PER MINUTE AT 60
5.106.4.1.4. FOR NEW SHELL BUILDINGS IN PHASED PROJECTS PROVIDE PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE FLOW
SECURE BICYCLE PARKING FOR 5 PERCENT OF THE ANTICIPATED ABOVE THE MAXIMUM RATE, BUT NOT TO EXCEED 2.2 GALLONS
5.106 SITE DEVELOPMENT TENANT-OCCUPANT VEHICULAR PARKING SPACES WITH A PER MINUTE AT 60 PSI, AND MUST DEFAULT TO A MAXIMUM FLOW
DATE:
5.106.1 STORM WATER POLLUTION PREVENTION FOR PROJECTS THAT
CIP NO.
5.106.4.1.2, 5.106.4.1.3, AND 5.106.4.1.4 SHALL BE CONVENIENT FLOW RATE OF NOT MORE THAN 1.8 GALLONS PER MINUTE/20 [RIM
DISTURB LESS THAN ONE ACRE OF LAND. NEWLY CONSTRUCTED FROM THE STREET AND SHALL MEET ONE OF THE FOLLOWING: SPACE (INCHES) AT 60 PSI].
F PROJECTS AND ADDITIONS WHICH DISTURB LESS THAN ONE ACRE
OF LAND, AND ARE NOT PART OF A LARGER COMMON PLAN OF
1. COVERED, LOCKABLE ENCLOSURES WITH PERMANENTLY 5.303.3.4.4 METERING FAUCETS. METERING FAUCETS SHALL NOT DELIVER
ANCHORED RACKS FOR BICYCLES; MORE THAN 0.20 GALLONS PER CYCLE.
DEVELOPMENT OR SALE, SHALL PREVENT THE POLLUTION OF 5.106.3.4.[N] IDENTIFICATION. THE SERVICE PANEL OR SUBPANEL(S) CIRCUIT
STORMWATER RUNOFF FROM THE CONSTRUCTION ACTIVITIES 2. LOCKABLE BICYCLE ROOMS WITH PERMANENTLY ANCHORED DIRECTORY SHALL IDENTIFY THE RESERVED OVERCURRENT 5.303.3.4.5 METERING FAUCETS FOR WASH FOUNTAINS. METERING FAUCETS
THROUGH ONE OR MORE OF THE FOLLOWING MEASURES: RACKS; OR PROTECTIVE DEVICE SPACE(S) FOR FUTURE EV CHARGING AS "EV FOR WASH FOUNTAINS SHALL HAVE A MAXIMUM FLOW RATE OF
5.106.1.1 LOCAL ORDINANCE. COMPLY WITH A LAWFULLY ENACTED STORM CAPABLE". THE RACEWAY TERMINATION LOCATION SHALL BE DIVISION 5.2 - ENERGY EFFICIENCY NOT MORE THAN 0.20 GALLONS PER CYCLE/ 20 [RIM SPACE
3. LOCKABLE, PERMANENTLY ANCHORED BICYCLE LOCKERS.
WATER MANAGEMENT AND/OR EROSION CONTROL ORDINANCE. PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE." (INCHES) AT 60 PSI].
NOTE: ADDITIONAL INFORMATION ON RECOMMENDED BICYCLE 5.106.5.3.5 [N] FUTURE CHARGING SPACES. FUTURE CHARGING SPACES
5.106.1.2 BEST MANAGEMENT PRACTICES (BMP'S). PREVENT THE LOSS OF ACCOMMODATIONS MAY BE OBTAINED FROM SACRAMENTO AREA NOTE: WHERE COMPLYING FAUCETS ARE UNAVAILABLE,
QUALIFY AS DESIGNATED PARKING AS DESCRIBED IN SECTION SECTION 5.301 GENERAL
SOIL THROUGH WIND OR WATER EROSION BY IMPLEMENTING AN BICYCLE ADVOCATES. AERATORS OR OTHER MEANS MAY BE USED TO ACHIEVE
EFFECTIVE COMBINATION OF EROSION AND SEDIMENT CONTROL 5.106.5 .2 DESIGNATED PARKING FOR CLEAN AIR VEHICLES. REDUCTION.
AND GOOD HOUSEKEEPING BMP'S. 5.106.4.2 BICYCLE PARKING. [DSA-SS] FOR PUBLIC SCHOOLS AND NOTE: FUTURE ELECTRIC VEHICLE CHARGING SPACES SHALL
COMMUNITY COLLEGES: NOT APPLICABLE FOR THIS PROJECT. COUNT TOWARD THE TOTAL PARKING SPACES REQUIRED BY THE 5.201.1 SCOPE. CALIFORNIA ENERGY CODE. FOR THE PURPOSES OF 5.303.3.4.6 PRE-RINSE SPRAY VALVE. WHEN INSTALLED, SHALL MEET THE
1. SOIL LOSS BMP'S THAT SHOULD BE CONSIDERED FOR LOCAL ENFORCING AGENCIES. MANDATORY ENERGY EFFICIENCY STANDARDS IN THIS CODE, THE REQUIREMENTS IN THE CALIFORNIA CODE OF REGULATIONS,
E IMPLEMENTATION AS APPROPRIATE FOR EACH PROJECT INCLUDE, 5.106.5.2 DESIGNATED PARKING FOR CLEAN AIR VEHICLES. IN NEW
PROJECTS OR ADDITIONS OR ALTERATIONS THAT ADD 10 OR 5.106.8 LIGHT POLLUTION REDUCTION. [N] OUTDOOR LIGHTING SYSTEMS
CALIFORNIA ENERGY COMMISSION WILL CONTINUE TO ADOPT TITLE 20 (APPLIANCE EFFICIENCY REGULATIONS), SECTION
BUT ARE NOT LIMITED TO, THE FOLLOWING: MANDATORY BUILDING STANDARDS. 1605.1(H)(4) TABLE H-2, SECTION 1605.3(H)(4)(A), AND SECTION
MORE VEHICULAR PARKING SPACES, PROVIDE DESIGNATED SHALL BE DESIGNED AND INSTALLED TO COMPLY WITH THE 1607(D)(7), AND SHALL BE EQUIPPED WITH AN INTEGRAL
A. SCHEDULING CONSTRUCTION ACTIVITY DURING DRY WEATHER, PARKING FOR ANY COMBINATION OF LOW-EMITTING, FOLLOWING: AUTOMATIC SHUTOFF.
WHEN POSSIBLE. FUEL-EFFICIENT AND CARPOOL/VAN POOL VEHICLES AS FOLLOWS: 1. THE MINIMUM REQUIREMENTS IN THE CALIFORNIA ENERGY CODE DIVISION 5.3- WATER EFFICIENCY AND CONSERVATION FOR REFERENCE ONLY: THE FOLLOWING TABLE AND CODE
REVISIONS:
B. PRESERVATION OF NATURAL FEATURES, VEGETATION, SOIL, AND FOR LIGHTING ZONES 0-4 AS DEFINED IN CHAPTER 10, SECTION SECTION HAVE BEEN REPRINTED FROM THE CALIFORNIA CODE OF
BUFFERS AROUND SURFACE WATERS. 10-114 OF THE CALIFORNIA ADMINISTRATIVE CODE; AND REGULATIONS, TITLE 20 (APPLIANCE EFFICIENCY REGULATIONS),
PARKING SPACES
C. DRAINAGE SWALES OR LINED DITCHES TO CONTROL STORM SECTION 5.301 GENERAL SECTION 1605.1(H)(4) AND SECTION 1605.3(H)( 4)(A).
INDEX NO.
2. BACKLIGHT (B) RATINGS AS DEFINED IN IES TM-15-11 (SHOWN IN
WATER FLOW. TABLE A-1 IN CHAPTER 8); UPLIGHT AND GLARE RATINGS AS
NO.
D. TABLE 5.106.5.2 DEFINED IN CALIFORNIA ENERGY CODE (SHOWN IN TABLES 130.2-A
AND 130.2-B IN CHAPTER 8) AND
E. EROSION CONTROL TO PROTECT SLOPES.
3. ALLOWABLE BUG RATINGS NOT EXCEEDING THOSE SHOWN IN 5.301.1 SCOPE. THE PROVISIONS OF THIS CHAPTER SHALL ESTABLISH
D F. PROTECTION OF STORM DRAIN INLETS (GRAVEL BAGS OR CATCH
TABLE 5.106.8 [N], OR COMPLY WITH A LOCAL ORDINANCE THE MEANS OF CONSERVING WATER USED INDOORS, OUTDOORS
BASIN INSERTS).
CITY ENGINEER
LAWFULLY ENACTED PURSUANT TO SECTION 101.7, WHICHEVER IS AND IN WASTEWATER CONVEYANCE
DATE:
G. PERIMETER SEDIMENT CONTROL (PERIMETER SILT FENCE, FIBER MORE STRINGENT.
ROLLS). EXCEPTIONS: SECTION 5.302 DEFINITIONS
H. SEDIMENT TRAP OR SEDIMENT BASIN TO RETAIN SEDIMENT ON 1. LUMINAIRES THAT QUALIFY AS EXCEPTIONS IN SECTIONS 130.2(B)
SITE. AND 140.7 OF THE CALIFORNIA ENERGY CODE.
I. STABILIZED CONSTRUCTION EXITS. 5.302.1 DEFINITIONS. THE FOLLOWING TERMS ARE DEFINED M CHAPTER 2.
2. EMERGENCY LIGHTING.
J. WIND EROSION CONTROL. EV APOTRANSPIRA TION ADJUSTMENT FACTOR (ET AF). (DSA-SS)
3. BUILDING FACADE MEETING THE REQUIREMENTS IN TABLE 140.7-B
K. OTHER SOIL LOSS BMP'S ACCEPTABLE TO THE ENFORCING OF THE CALIFORNIA ENERGY CODE, PART 6. FOOTPRINT AREA (DSA-SS)
VALVES MANUFACTURED ON OR AFTER JANUARY I, 2006, SHALL
AGENCY. 4. CUSTOM LIGHTING FEATURES AS ALLOWED BY THE LOCAL GRAYWATER. HAVE A MINIMUM SPRAY FORCE OF NOT LESS THAN 4.0
C ENFORCING AGENCY, AS PERMITTED BY SECTION 101.8
METERING FAUCET.
OUNCES-FORCE (OZT) [113 GRAMS-FORCE (GT)].
NOTE: DESIGNATED PARKING FOR CLEAN AIR VEHICLES SHALL ALTERNATE MATERIALS, DESIGNS AND METHODS OF
DESIGN GROUP
2. GOOD HOUSEKEEPING BMP'S TO MANAGE CONSTRUCTION CONSTRUCTION. MODEL WATER EFFICIENT LANDSCAPE
COUNT TOWARD THE TOTAL PARKING SPACES REQUIRED BY THE
EQUIPMENT, MATERIALS, NON-STORMWATER DISCHARGES, AND
LOCAL ENFORCING AGENCIES. 5. LUMINAIRES WITH LESS THAN 6,200 INITIAL LUMINAIRE LUMENS. 5.303.4 COMMERCIAL KITCHEN EQUIPMENT
WASTES THAT SHOULD BE CONSIDERED FOR IMPLEMENTATION ORDINANCE (MWELO).
AS APPROPRIATE FOR EACH PROJECT INCLUDE, BUT ARE NOT 5.106.5.2.1 PARKING STALL MARKING. PAINT, IN THE PAINT USED FOR STALL 5.106.8.1 FACING - BACKLIGHT. LUMINAIRES WITHIN 2MH OF A PROPERTY
STRIPING, THE FOLLOWING CHARACTERS SUCH THAT THE LOWER POTABLE WATER.
LIMITED TO, THE FOLLOWING: LINE SHALL BE ORIENTED SO THAT THE NEAREST PROPERTY LINE
EDGE OF THE LAST WORD ALIGNS WITH THE END OF THE STALL 5.303.4.1 FOOD WASTE DISPOSERS. DISPOSERS SHALL EITHER MODULATE
IS BEHIND THE FIXTURE, AND SHALL COMPLY WITH THE RECLAIMED (RECYCLED) WATER.
A. DEWATERING ACTIVITIES. STRIPING AND IS VISIBLE BENEATH A PARKED VEHICLE: THE USE OF WATER TO NO MORE THAN 1 GPM WHEN THE
BACKLIGHT RATING SPECIFIED IN TABLE 5.106.8 BASED ON THE RECYCLED WATER. DISPOSER IS NOT IN USE (NOT ACTIVELY GRINDING FOOD
B. MATERIAL HANDLING AND WASTE MANAGEMENT. CLEAN AIR/ VANPOOL/EV LIGHTING ZONE AND DISTANCE TO THE NEAREST POINT OF THAT
PROPERTY LINE. SPECIAL LANDSCAPE AREA (SLA). (DSA-SS)
C. BUILDING MATERIALS STOCKPILE MANAGEMENT. NOTE: VEHICLES BEARING CLEAN AIR VEHICLE STICKERS FROM MORE THAN 10 MINUTES OF INACTIVITY. DISPOSERS SHALL USE
APPROVED BY:
COMPLY WITH SECTION 5.106.5.3.1 OR SECTION 5 .106.5.3 .2 TO
DESIGNED BY:
CHECKED BY:
STAGING AREA. CORNER) IS DIRECTLY BEHIND THE LUMINAIRE. THE LUMINAIRE 5.303.5 AREAS OF ADDITION OR ALTERATION. FOR THOSE OCCUPANCIES
FACILITATE FUTURE INSTALLATION OF ELECTRIC VEHICLE SUPPLY
DRAWN BY:
ENGINEER:
F. VEHICLE AND EQUIPMENT CLEANING PERFORMED OFF SITE. SHALL STILL USE THE DISTANCE TO THE NEAREST POINT(S) ON WITHIN THE AUTHORITY OF THE CALIFORNIA BUILDING
EQUIPMENT (EVSE). WHEN EVSE(S) IS/ARE INSTALLED, IT SHALL BE
THE PROPERTY LINES TO DETERMINE THE REQUIRED BACKLIGHT 5.303.1 METERS. SEPARATE SUBMETERS OR METERING DEVICES SHALL STANDARDS COMMISSION AS SPECIFIED IN SECTION 103, THE
G. SPILL PREVENTION AND CONTROL. IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE, THE
RATING. BE INSTALLED FOR THE USES DESCRIBED IN SECTIONS 5 .303.1.1 PROVISIONS OF SECTIONS 5.303.3 AND 5.303.4 SHALL APPLY TO
CALIFORNIA ELECTRICAL CODE AND AS FOLLOWS:
H. OTHER HOUSEKEEPING BMP'S ACCEPTABLE TO THE ENFORCING 5.106.8.2 FACING - GLARE. FOR LUMINAIRES COVERED BY 5.106.8.1, IF A AND 5.303.1.2. NEW FIXTURES IN ADDITIONS OR AREAS OF ALTERATION TO THE
5.106.5.3.1 SINGLE CHARGING SPACE REQUIREMENTS. [N] WHEN ONLY A
AGENCY. PROPERTY LINE ALSO EXISTS WITHIN OR EXTENDS INTO THE 5.303.1.1 NEW BUILDINGS OR ADDITIONS IN EXCESS OF 50,000 SQUARE BUILDING.
SINGLE CHARGING SPACE IS REQUIRED PER TABLE 5.106.5.3.3, A
FRONT HEMISPHERE WITHIN 2MH OF THE LUMINAIRE THEN THE FEET. SEPARATE SUBMETERS SHALL BE INSTALLED AS FOLLOWS: WORK ORDER NO.
RACEWAY IS REQUIRED TO BE INSTALLED AT THE TIME OF
LUMINAIRE SHALL COMPLY WITH THE MORE STRINGENT GLARE 1. FOR EACH INDIVIDUAL LEASED, RENTED, OR OTHER TENANT
5.106.2 STORM WATER POLLUTION PREVENTION FOR PROJECTS THAT CONSTRUCTION AND SHALL BE INSTALLED IN ACCORDANCE WITH
RATING SPECIFIED IN TABLE 5.106.8 BASED ON THE LIGHTING SPACE WITHIN THE BUILDING PROJECTED TO CONSUME MORE
SECTION 5.304 OUTDOOR WATER USE E170121B
(DESIGN STAGE ONLY)
DISTURB ONE OR MORE ACRES OF LAND. COMPLY WITH ALL ZONE AND DISTANCE TO THE NEAREST POINT ON THE NEAREST
SPECIFICATIONS SHALL INCLUDE, BUT ARE NOT LIMITED TO, THE THAN 100 GAL/DAY (380 L/DAY), INCLUDING, BUT NOT LIMITED TO,
A LAWFULLY ENACTED STORM WATER DISCHARGE REGULATIONS
FOLLOWING:
PROPERTY LINE WITHIN THE FRONT HEMISPHERE. SPACES USED FOR LAUNDRY OR CLEANERS, RESTAURANT OR SHEET NAME
REVISION DATES
A0.15
OR (2) DISTURB LESS THAN ONE ACRE OF LAND BUT ARC PART OF THE TYPE AND LOCATION OF THE EVSE.
BEAUTY SALON OR BARBER SHOP.
A LARGER COMMON PLAN OF DEVELOPMENT OR SALE.
2. A LISTED RACEWAY CAPABLE OF ACCOMMODATING A
208/240-VOLT DEDICATED BRANCH CIRCUIT. NON-RESIDENTIAL GREEN BUILDING NOTES CONTINUE ON SHEET A0.16.
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A015_24X36.DWG 12/3/2021 9:07 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
5.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. 3. IDENTIFIES DIVERSION FACILITIES WHERE CONSTRUCTION AND 5.501.1 SCOPE. THE PROVISIONS OF THIS CHAPTER SHALL OUTLINE 5.504.4.4.1 CARPET CUSHION. ALL CARPET CUSHION INSTALLED IN THE
NONRESIDENTIAL DEVELOPMENTS SHALL COMPLY WITH A LOCAL DEMOLITION WASTE MATERIAL COLLECTED WILL BE TAKEN. MEANS OF REDUCING THE QUANTITY OF AIR CONTAMINANTS ENGINEERING
WATER EFFICIENT LANDSCAPE ORDINANCE OR THE CURRENT 4. SPECIFIES THAT THE AMOUNT OF CONSTRUCTION AND THAT ARE ODOROUS, IRRITATING, AND/OR HARMFUL TO THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, "STANDARD
METHOD FOR THE TESTING AND EVALUATION OF VOLATILE
WATER EFFICIENT LANDSCAPE ORDINANCE (MWELO), WHICHEVER CALCULATED BY WEIGHT OR VOLUME, BUT NOT BY BOTH. OCCUPANTS AND NEIGHBORS. ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING
IS MORE STRINGENT. ENVIRONMENTAL CHAMBERS," VERSION 1.2, JANUARY 2017
K NOTES:
5.408.1.2. WASTE MANAGEMENT COMPANY. UTILIZE A WASTE MANAGEMENT (EMISSION TESTING METHOD FOR CALIFORNIA SPECIFICATION O
COMPANY THAT CAN PROVIDE VERIFIABLE DOCUMENTATION THAT SECTION 5.502 DEFINITIONS 1350).
1. THE MODEL WATER EFFICIENT LANDSCAPE ORDINANCE (MWELO)
IS LOCATED IN THE CALIFORNIA CODE OF REGULATIONS, TITLE 23, MATERIAL DIVERTED FROM THE LANDFILL COMPLIES WITH THIS
CHAPTER 2.7, DIVISION 2. SECTION. 5.502.1 DEFINITIONS. THE FOLLOWING TERMS ARE DEFINED IN CHAPTER FOR CERTIFICATION PROGRAMS AND TESTING LABS.
NOTE: THE OWNER OR CONTRACTOR SHALL MAKE THE 2. HTTPS://WWW .CDPH.CA.GOV/PROGRAMS/CCDPHP/
2. MWELO AND SUPPORTING DOCUMENTS, INCLUDING A WATER DEODC/EHLB/IAQ/PAGESNOC.ASPX#MATERIAL
BUDGET CALCULATOR, ARE AVAILABLE AT: HTTPS:// ARTERIAL HIGHWAY. TABLE 5.504.4.2
MATERIAL WILL BE DIVERTED BY A WASTE MANAGEMENT 5.504.4.4.2 CARPET ADHESIVE. ALL CARPET ADHESIVE SHALL MEET THE
WWW.WATER.CA.GOV/.
COMPANY. A-WEIGHTED SOUND LEVEL (DBA). REQUIREMENTS OF TABLE 5.504.4.1.
5.304.6 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. FOR EXCEPTIONS TO SECTIONS 5.408.1.1 AND 5.408.1.2:
PUBLIC SCHOOLS AND COMMUNITY COLLEGES, LANDSCAPE 1 BTU/HOUR. 5.504.4.5
1. EXCAVATED SOIL AND LAND-CLEARING DEBRIS. PARTICLEBOARD AND MEDIUM DENSITY FIBERBOARD COMPOSITE
PROJECTS AS DESCRIBED IN SECTIONS 5.304.6.1 AND 5.304.6.2 COMMUNITY NOISE EQUIVALENT LEVEL (CNEL).
SHALL COMPLY WITH THE CALIFORNIA DEPARTMENT OF WATER 2. ALTERNATE WASTE REDUCTION METHODS DEVELOPED BY WOOD PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF THE
J RESOURCES MODEL WATER EFFICIENT LANDSCAPE ORDINANCE WORKING WITH LOCAL AGENCIES IF DIVERSION OR RECYCLE COMPOSITE WOOD PRODUCTS.
(MWELO) COMMENCING WITH SECTION 490 OF CHAPTER 2.7, FACILITIES CAPABLE OF COMPLIANCE WITH THIS ITEM DO NOT AS SPECIFIED IN ARB'S AIR TOXICS CONTROL MEASURE (ATCM)
DAY-NIGHT AVERAGE SOUND LEVEL (LDN). FOR COMPOSITE WOOD (17 CCR 93120 ET SEQ.) THOSE
DIVISION 2, TITLE 23, CALIFORNIA CODE OF REGULATIONS, EXIST.
EXCEPT THAT THE EVAPOTRANSPIRATION ADJUSTMENT FACTOR DECIBEL (DB). MATERIALS NOT EXEMPTED UNDER THE A TCM MUST MEET THE
3. DEMOLITION WASTE MEETING LOCAL ORDINANCE OR SPECIFIED EMISSION LIMITS, AS SHOWN IN TABLE 5.504.4.5.
(ETAF) SHALL BE 0.65 WITH AN ADDITIONAL WATER ALLOWANCE ENERGY EQUIVALENT (NOISE) LEVEL (LEQ).
FOR SPECIAL LANDSCAPE AREAS (SLA) OF 0.35. 10/31/2023
EXPRESSWAY.
EXCEPTION: ANY PROJECT WITH AN AGGREGATE LANDSCAPE 5.408.1.3 WASTE STREAM REDUCTION ALTERNATIVE. THE COMBINED TABLE 5.504.4.5
AREA OF 2,500 SQUARE FEET OR LESS MAY COMPLY WITH THE WEIGHT OF NEW CONSTRUCTION DISPOSAL THAT DOES NOT FREEWAY.
PRESCRIPTIVE MEASURES CONTAINED IN APPENDIX D OF THE EXCEED TWO POUNDS PER SQUARE FOOT OF BUILDING AREA GLOBAL WARMING POTENTIAL (GWP).
MWELO. MAY BE DEEMED TO MEET THE 65 PERCENT MINIMUM
REQUIREMENT AS APPROVED BY THE ENFORCING AGENCY. GLOBAL WARMING POTENTIAL VALUE (GWP VALUE).
5.304.6.1
PROJECTS WITH AN AGGREGATE LANDSCAPE AREA EQUAL TO OR HIGH-GWP REFRIGERANT.
I GREATER THAN 500 SQUARE FEET.
5.408.1.4
ENFORCING AGENCY WHICH DEMONSTRATES COMPLIANCE WITH NONRESIDENTIAL MANDATORY MEASURES
5.304.6.2 SECTIONS 5.408.1.1 THROUGH 5.408.1.3. THE WASTE MANAGEMENT
PROJECTS WITH AN AGGREGATE LANDSCAPE AREA EQUAL TO OR PLAN SHALL BE UPDATED AS NECESSARY AND SHALL BE LONG RADIUS ELBOW.
HORIZONTAL CONTROL:
UNIVERSAL WASTE ITEMS SUCH AS FLUORESCENT LAMPS AND SECTION 5.504 POLLUTANT CONTROL OZONE DEPLETING SUBSTANCES, IN SECTIONS 94522(C)(2) AND 3. PRODUCT LABELED AND INVOICED AS MEETING THE COMPOSITE
VERTICAL CONTROL:
WOOD PRODUCTS REGULATION (SEE CCR, TITLE 17, SECTION
G SECTION 5.402 DEFINITIONS OTHER CALIFORNIA PROHIBITED UNIVERSAL WASTE MATERIALS
5.504.1
COMMENCING WITH SECTION 94520; AND IN AREAS UNDER THE
JURISDICTION OF THE BAY AREA AIR QUALITY MANAGEMENT
93120, ET SEQ.).
ARE DISPOSED OF PROPERLY AND ARE DIVERTED FROM
SHEET TITLE:
SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO 4. EXTERIOR GRADE PRODUCTS MARKED AS MEETING THE PS-I OR
LANDFILLS. A LIST OF PROHIBITED UNIVERSAL WASTE MATERIALS DISTRICT ADDITIONALLY COMPLY WITH THE PERCENT VOC BY
ADDRESS:
PROJECT:
CONDITION THE BUILDING OR AREAS OF ADDITION OR PS-2 STANDARDS OF THE ENGINEERED WOOD ASSOCIATION, THE
5.402.1 DEFINITIONS. THE FOLLOWING TERMS ARE DEFINED M CHAPTER 2. SHALL BE INCLUDED IN THE CONSTRUCTION DOCUMENTS. WEIGHT OF PRODUCT LIMITS OF REGULATION 8 RULE 49.
ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE FOR AUSTRALIAN AS/NZS 2269 OR EUROPEAN 636 3S STANDARDS.
ADJUST. NOTE: REFER TO THE UNIVERSAL WASTE RULE LINK AT: HTTPS:// 5.504.4.3.2 VERIFICATION. VERIFICATION OF COMPLIANCE WITH THIS SECTION
MATERIAL AND EQUIPMENT INSTALLATION. IF THE HV AC SYSTEM 5. OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY
DTSC.CA.GOV/UNIVERSALWASTE/ SHALL BE PROVIDED AT THE REQUEST OF THE ENFORCING
BALANCE. IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH
5.408.3 AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS NOT LIMITED TO, 5.504.4.6 RESILIENT FLOORING SYSTEMS. WHERE RESILIENT FLOORING IS
A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED
BUILDING COMMISSIONING. TREES, STUMPS, ROCKS AND ASSOCIATED VEGETATION AND THE FOLLOWING: INSTALLED, AT LEAST 80 PERCENT OF FLOOR AREA RECEIVING
BY:
SOILS RESULTING PRIMARILY FROM LAND CLEARING SHALL BE PERCENT BASED ON ASHRAE 52.1- 1992. REPLACE ALL FILTERS TABLE 5.504.4.3 RESILIENT FLOORING SHALL MEET THE REQUIREMENTS OF THE
ORGANIC WASTE. CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, "STANDARD
REUSED OR RECYCLED. FOR A PHASED PROJECT, SUCH IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS
METHOD FOR THE TESTING AND EVALUATION OF VOLATILE
DATE:
CIP NO.
TEST. OCCUPIED DURING ALTERATION, AT THE CONCLUSION OF
SITE IS DEVELOPED. CONSTRUCTION. ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING
F EXCEPTION: REUSE, EITHER ON-OR OFF-SITE, OF VEGETATION OR 5.504.3 COVERING OF DUCT OPENINGS AND PROTECTION OF (EMISSION TESTING METHOD FOR CALIFORNIA SPECIFICATION
SECTION 5.403 FOUNDATION SYSTEMS (RESERVED) SOIL CONTAMINATED BY DISEASE OR PEST INFESTATION. MECHANICAL EQUIPMENT DURING CONSTRUCTION. AT THE TIME 01350).
NOTES: OF ROUGH INSTALLATION AND DURING STORAGE ON THE
CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HEATING, SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S WEBSITE FOR
SECTION 5.404 EFFICIENT FRAMING TECHNIQUES (RESERVED) 1. IF CONTAMINATION BY DISEASE OR PEST INFESTATION IS CERTIFICATION PROGRAMS AND TESTING LABS.
SUSPECTED, CONTACT THE COUNTY AGRICULTURAL RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE HTTPS://WWW.CDPH.CA.GOV/PROGRAMS/CCDPHP/DEODC/EHLB/IA
COVERED WITH TAPE, PLASTIC, SHEETMETAL OR OTHER Q/PAGESVOC.ASPX#MATERIAL
SECTION 5.405 MATERIAL SOURCES (RESERVED) METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE 5.504.4.6.1
(WWW.CDFA.CA.GOV/EXEC/COUNTY/COUNTY _CONTACTS.HTML) THE AMOUNT OF DUST, WATER AND DEBRIS WHICH MAY ENTER PROVIDED VERIFYING THAT RESILIENT FLOORING MATERIALS
2. FOR A MAP OF KNOWN PEST AND/OR DISEASE QUARANTINE THE SYSTEM. MEET THE POLLUTANT EMISSION LIMITS.
SECTION 5.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE (RESERVED)
ZONES, CONSULT WITH THE CALIFORNIA DEPARTMENT OF FOOD 5.504.4 FINISH MATERIAL POLLUTANT CONTROL. FINISH MATERIALS SHALL
AND AGRICULTURE. (WWW.CDFA.CA.GOV) COMPLY WITH SECTIONS 5.504.4.1 THROUGH 5.504.4.6.
E 5.504.5.3 FILTERS. IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE
SECTION 5.407 WATER RESISTANCE AND MOISTURE MANAGEMENT 5.504.4.1 ADHESIVES, SEALANTS AND CAULKS. ADHESIVES, SEALANTS, AND REGULARLY OCCUPIED AREAS OF THE BUILDING WITH AIR
CAULKS USED ON THE PROJECT SHALL MEET THE REQUIREMENTS FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR THAT
SECTION 5.409 LIFE CYCLE ASSESSMENT (RESERVED) OF THE FOLLOWING STANDARDS: PROVIDES AT LEAST A MINIMUM EFFICIENCY REPORTING VALUE
5.407.1 WEATHER PROTECTION. PROVIDE A WEATHER-RESISTANT 1. ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, (MERV) OF 13. MERV 13 FILTERS SHALL BE INSTALLED PRIOR TO
EXTERIOR WALL AND FOUNDATION ENVELOPE AS REQUIRED BY
REVISIONS:
SECTION 5.410 BUILDING MAINTENANCE AND OPERATION SEALANTS, SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH OCCUPANCY, AND RECOMMENDATIONS FOR MAINTENANCE WITH
CALIFORNIA BUILDING CODE SECTION 1402.2 (WEATHER LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY FILTERS OF THE SAME VALUE SHALL BE INCLUDED IN THE
PROTECTION), MANUFACTURER'S INSTALLATION INSTRUCTIONS
INDEX NO.
OR LOCAL ORDINANCE, WHICHEVER IS MORE STRINGENT. RULE 1168 VOC LIMITS, AS SHOWN IN TABLES 5.504.4. L AND EXCEPTION: EXISTING MECHANICAL EQUIPMENT.
5.410.1 RECYCLING BY OCCUPANTS. PROVIDE READILY ACCESSIBLE
5.407.2 AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED 5.504.4.2. SUCH PRODUCTS ALSO SHALL COMPLY WITH THE RULE 5.504.5.3.1 LABELING. INSTALLED FILTERS SHALL BE CLEARLY LABELED BY
NO.
BY THE FOLLOWING METHODS. FOR THE DEPOSITING, STORAGE AND COLLECTION OF 1168 PROHIBITION ON THE USE OF CERTAIN TOXIC COMPOUNDS THE MANUFACTURER INDICATING THE MERV RATING.
5.407.2.1 NON-HAZARDOUS MATERIALS FOR RECYCLING, INCLUDING (AT A
SYSTEMS TO PREVENT SPRAY ON STRUCTURES. MINIMUM) PAPER, CORRUGATED CARDBOARD; GLASS, PLASTICS,
D ORGANIC WASTE, AND METALS OR MEET A LAWFULLY ENACTED AEROSOL PRODUCTS AS SPECIFIED IN SUBSECTION 2, BELOW. 5.504.7 ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL. WHERE
5.407.2.2 ENTRIES AND OPENINGS. DESIGN EXTERIOR ENTRIES AND/OR
CITY ENGINEER
LOCAL RECYCLING ORDINANCE, IF MORE RESTRICTIVE. OUTDOOR AREAS ARE PROVIDED FOR SMOKING, PROHIBIT
DATE:
2.
OPENINGS SUBJECT TO FOOT TRAFFIC OR WIND-DRIVEN RAIN TO SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR
EXCEPTION: RURAL JURISDICTIONS THAT MEET AND APPLY FOR AND SEALANT OR CAULKING COMPOUNDS (IN UNITS OF PRODUCT,
PREVENT WATER INTRUSION INTO BUILDINGS AS FOLLOWS: INTAKES AND OPERABLE WINDOWS AND WITHIN THE BUILDING AS
THE EXEMPTION IN PUBLIC RESOURCES CODE 42649.82 (A)(2)(A) LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN ONE POUND
5.407.2.2.1 EXTERIOR DOOR PROTECTION. PRIMARY EXTERIOR ENTRIES AND DO NOT CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL
SHALL BE COVERED TO PREVENT WATER INTRUSION BY USING ET SEQ. SHALL ALSO BE EXEMPT FROM THE ORGANIC WASTE
PORTION OF THIS SECTION. COMPLY WITH STATEWIDE VOC STANDARDS AND OTHER
NONABSORBENT FLOOR AND WALL FINISHES WITHIN AT LEAST 2 REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN CITY, COUNTY, CITY AND COUNTY, CALIFORNIA COMMUNITY
FEET AROUND AND PERPENDICULAR TO SUCH OPENINGS PLUS AT 5.410.1.1 ADDITIONS. ALL ADDITIONS CONDUCTED WITHIN A 12- MONTH TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS,
LEAST ONE OF THE FOLLOWING: PERIOD UNDER SINGLE OR MULTIPLE PERMITS, RESULTING IN AN
1. AN INSTALLED AWNING AT LEAST 4 FEET IN DEPTH. INCREASE OF 30 PERCENT OR MORE IN FLOOR AREA, SHALL MORE STRINGENT. WHEN ORDINANCES, REGULATIONS OR
POLICIES ARE NOT IN PLACE, POST SIGNAGE TO INFORM BUILDING
2. THE DOOR IS PROTECTED BY A ROOF OVERHANG AT LEAST 4 TABLE 5.504.4.1 OCCUPANTS OF THE PROHIBITIONS.
EXCEPTION: ADDITIONS WITHIN A TENANT SPACE RESULTING IN
FEET IN DEPTH.
C LESS THAN A 30-PERCENT INCREASE IN THE TENANT SPACE
3. THE DOOR IS RECESSED AT LEAST 4 FEET. FLOOR AREA.
DESIGN GROUP
SECTION 5.505 INDOOR MOISTURE CONTROL
4. OTHER METHODS WHICH PROVIDE EQUIVALENT PROTECTION. 5.410.1.2 SPACE ALLOCATION FOR RECYCLING AREAS SHALL COMPLY WITH
CHAPTER 18, PART 3, DIVISION 30 OF THE PUBLIC RESOURCES
5.407.2.2.2 FLASHING. INSTALL FLASHINGS INTEGRATED WITH A DRAINAGE CODE. CHAPTER 18 IS KNOWN AS THE CALIFORNIA SOLID WASTE
PLANE. 5.505.1 INDOOR MOISTURE CONTROL. BUILDINGS SHALL MEET OR
REUSE AND RECYCLING ACCESS ACT OF 1991 (ACT). EXCEED THE PROVISIONS OF CALIFORNIA BUILDING CODE, CCR, 11
NOTE: A SAMPLE ORDINANCE FOR USE BY LOCAL AGENCIES MAY TITLE 24, PART 2, SECTIONS 1202 (VENTILATION) AND CHAPTER 14
SECTION 5.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING BE FOUND IN APPENDIX A OF THE DOCUMENT AT THE (EXTERIOR WALLS). FOR ADDITIONAL MEASURES, SEE SECTION
CALRECYCLE'S WEB SITE. 5.407.2 OF THIS CODE.
5.410.2 COMMISSIONING. [N] NEW BUILDINGS 10,000 SQUARE FEET AND
APPROVED BY:
5.506.1 OUTSIDE AIR DELIVERY. FOR MECHANICALLY OR NATURALLY
DESIGNED BY:
MEET A LOCAL CONSTRUCTION AND DEMOLITION WASTE
CHECKED BY:
THE OWNER'S OR OWNER REPRESENTATIVE'S PROJECT VENTILATED SPACES IN BUILDINGS, MEET THE MINIMUM
DRAWN BY:
MANAGEMENT ORDINANCE, WHICHEVER IS MORE STRINGENT. 5.504.4.4 CARPET SYSTEMS. ALL CARPET INSTALLED IN THE BUILDING
ENGINEER:
REQUIREMENTS. COMMISSIONING SHALL BE PERFORMED IN
5.408.1.1 CONSTRUCTION WASTE MANAGEMENT PLAN. WHERE A LOCAL ACCORDANCE WITH THIS SECTION BY TRAINED PERSONNEL WITH VENTILATION) OF THE CALIFORNIA ENERGY CODE, OR THE
EXPERIENCE ON PROJECTS OF COMPARABLE SIZE AND DEPARTMENT OF PUBLIC HEALTH, "STANDARD METHOD FOR THE
JURISDICTION DOES NOT HAVE A CONSTRUCTION AND
DEMOLITION WASTE MANAGEMENT ORDINANCE THAT IS MORE COMPLEXITY. NOT APPLICABLE AS COMMERCIAL AREA IS NOT TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL
EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL DIVISION 1, CHAPTER 4 OF CCR, TITLE 8.
STRINGENT, SUBMIT A CONSTRUCTION WASTE MANAGEMENT OVER 10,000 SF.
PLAN THAT CHAMBERS," VERSION 1.2, JANUARY 2017 (EMISSION TESTING 5.506.2 CARBON DIOXIDE (CO2) MONITORING. FOR BUILDINGS OR
METHOD FOR CALIFORNIA SPECIFICATION 01350). ADDITIONS EQUIPPED WITH DEMAND CONTROL VENTILATION, CO2 WORK ORDER NO.
1. IDENTIFIES THE CONSTRUCTION AND DEMOLITION WASTE
MATERIALS TO BE DIVERTED FROM DISPOSAL BY EFFICIENT
SECTION 5.407 WATER RESISTANCE AND MOISTURE MANAGEMENT SENSORS AND VENTILATION CONTROLS SHALL BE SPECIFIED AND E170121B
INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE
(DESIGN STAGE ONLY)
USAGE, RECYCLING, REUSE ON THE PROJECT OR SALVAGE FOR SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S WEBSITE FOR
A FUTURE USE OR SALE. CERTIFICATION PROGRAMS AND TESTING LABS. SHEET NAME
REVISION DATES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A016_24X36.DWG 12/3/2021 9:07 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
5.507.4 ACOUSTICAL CONTROL. EMPLOY BUILDING ASSEMBLIES AND 5.508.2.2 VALVES. VALVES AND FITTINGS SHALL COMPLY WITH THE
COMPONENTS WITH SOUND TRANSMISSION CLASS (STC) VALUES CALIFORNIA MECHANICAL CODE AND AS FOLLOWS. ENGINEERING
DETERMINED IN ACCORDANCE WITH ASTM E90 AND ASTM E413 OR 5.508.2.2.1
OUTDOOR-INDOOR SOUND TRANSMISSION CLASS (OITC) HIGH-GWP REFRIGERANT, A RUPTURE DISC SHALL BE INSTALLED
BETWEEN THE OUTLET OF THE VESSEL AND THE INLET OF THE
K 5.507.4.1 OR 5.507.4.2.
PRESSURE RELIEF VALVE.
5.508.2.2.1.1 PRESSURE DETECTION. A PRESSURE GAUGE, PRESSURE
EXCEPTION: BUILDINGS WITH FEW OR NO OCCUPANTS OR WHERE TRANSDUCER OR OTHER DEVICE SHALL BE INSTALLED IN THE
OCCUPANTS ARE NOT LIKELY TO BE AFFECTED BY EXTERIOR SPACE BETWEEN THE RUPTURE DISC AND THE RELIEF VALVE
NOISE, AS DETERMINED BY THE ENFORCEMENT AUTHORITY, SUCH INLET TO INDICATE A DISC RUPTURE OR DISCHARGE OF THE
RELIEF VALVE.
STRUCTURES AND UTILITY BUILDINGS.
5.508.2.2.2 ACCESS VALVES. ONLY SCHRADER ACCESS VALVES WITH A
EXCEPTION: [DSA-SS] FOR PUBLIC SCHOOLS AND COMMUNITY BRASS OR STEEL BODY ARE PERMITTED FOR USE.
COLLEGES, THE REQUIREMENTS OF THIS SECTION AND ALL
5.508.2.2.2.1
POUNDS OR MORE, VALVE CAPS SHALL BE BRASS OR STEEL AND
5.507.4.1 EXTERIOR NOISE TRANSMISSION, PRESCRIPTIVE NOT PLASTIC.
METHOD. WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE
5.508.2.2.2.2 SEAL CAPS. IF DESIGNED FOR IT, THE CAP SHALL HAVE A
J NOISE SOURCE MAKING UP THE BUILDING OR ADDITION
NEOPRENE O-RING IN PLACE.
ENVELOPE OR ALTERED ENVELOPE SHALL MEET A COMPOSITE
STC RATING OF AT LEAST 50 OR A COMPOSITE OITC RATING OF NO 5.508.2.2.2.2.1 CHAIN TETHERS. CHAIN TETHERS TO FIT OVER THE STEM ARE
LESS THAN 40, WITH EXTERIOR WINDOWS OF A MINIMUM STC OF REQUIRED FOR VALVES DESIGNED TO HAVE SEAL CAPS.
40 OR OITC OF 30 IN THE FOLLOWING LOCATIONS: EXCEPTION: VALVES WITH SEAL CAPS THAT ARE NOT REMOVED
1. WITHIN THE 65 CNEL NOISE CONTOUR OF AN AIRPORT. FROM THE VALVE DURING STEM OPERATION. 10/31/2023
EXCEPTIONS: 5.508.2.3
HOLDING FOOD PRODUCTS CONTAINING VINEGAR AND SALT
1. LDN OR CNEL FOR MILITARY AIRPORTS SHALL BE DETERMINED BY SHALL HAVE EVAPORATOR COILS OF CORROSION-RESISTANT
THE FACILITY AIR INSTALLATION COMPATIBLE LAND USE ZONE MATERIAL, SUCH AS STAINLESS STEEL; OR BE COATED TO
(AICUZ) PLAN. PREVENT CORROSION FROM THESE SUBSTANCES.
2. LDN OR CNEL FOR OTHER AIRPORTS AND HELIPORTS FOR WHICH 5.508.2.3.1 COIL COATING. CONSIDERATION SHALL BE GIVEN TO THE HEAT
I A LAND USE PLAN HAS NOT BEEN DEVELOPED SHALL BE
DETERMINED BY THE LOCAL GENERAL PLAN NOISE ELEMENT. EFFICIENCY.
2. 5.508.2.4 REFRIGERANT RECEIVERS. REFRIGERANT RECEIVERS WITH
ASSEMBLIES EXPOSED TO THE NOISE SOURCE MAKING UP THE THE SAME GAUGE.
BUILDING OR ADDITION ENVELOPE OR ALTERED ENVELOPE SHALL
5.508.2.6 EVACUATION. THE SYSTEM SHALL BE EVACUATED AFTER
BE CONSTRUCTED TO PROVIDE AN INTERIOR NOISE
PRESSURE TESTING AND PRIOR TO CHARGING.
ENVIRONMENT ATTRIBUTABLE TO EXTERIOR SOURCES THAT
DOES NOT EXCEED AN HOURLY EQUIVALENT NOISE LEVEL (LCQ-1 5.508.2.6.1 FIRST VACUUM. PULL A SYSTEM VACUUM DOWN TO AT LEAST 1000
HORIZONTAL CONTROL:
MICRONS(+/- 50 MICRONS), AND HOLD FOR 30 MINUTES.
VERTICAL CONTROL:
OPERATION. 5.508.2.6.2
G 5.507.4.2.1 SITE FEATURES. EXTERIOR FEATURES SUCH AS SOUND WALLS OR MINIMUM OF 500 MICRONS AND HOLD FOR 30 MINUTES.
SHEET TITLE:
5.508.2.6.3 THIRD VACUUM. PULL A THIRD VACUUM DOWN TO A MINIMUM OF
ADDRESS:
PROJECT:
300 MICRONS, AND HOLD FOR 24 HOURS WITH A MAXIMUM DRIFT
SOUND MIGRATION TO THE INTERIOR. OF I 00 MICRONS OVER A 24-HOUR PERIOD
5.507.4.2.2
END OF NON-RESIDENTIAL GREEN BUILDING GENERAL NOTES.
DOCUMENTING COMPLYING INTERIOR SOUND LEVELS SHALL BE
PREPARED BY PERSONNEL APPROVED BY THE ARCHITECT OR
ENGINEER OF RECORD.
DATE:
CIP NO.
ASSEMBLIES SEPARATING TENANT SPACES AND TENANT SPACES
AND PUBLIC PLACES SHALL HAVE AN STC OF AT LEAST 40.
F NOTE: EXAMPLES OF ASSEMBLIES AND THEIR VARIOUS STC
RATINGS MAY BE FOUND AT THE CALIFORNIA OFFICE OF NOISE
CONTROL: HTTP://WWW.TOOLBASE.ORG/PDF/CASESTUDIES/
STC_ICC_RATINGS. PDF.
REVISIONS:
EQUIPMENT THAT DO NOT CONTAIN HALONS.
INDEX NO.
5.508.2 SUPERMARKET REFRIGERANT LEAK REDUCTION. NEW
COMMERCIAL REFRIGERATION SYSTEMS SHALL COMPLY WITH
NO.
FOOD STORES 8,000 SQUARE FEET OR MORE CONDITIONED AREA,
D AND THAT UTILIZE EITHER REFRIGERATED DISPLAY CASES, OR
CITY ENGINEER
DATE:
COMPRESSOR UNITS OR CONDENSING UNITS. THE LEAK
DESIGN GROUP
AND POTENTIALLY OTHER REFRIGERANTS.
5.508.2.1 REFRIGERANT PIPING. PIPING COMPLIANT WITH THE CALIFORNIA
APPROVED BY:
POUNDS OR LESS.
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
5.508.2.1.2.1
SECURELY CLAMPED TO A RIGID BASE TO KEEP VIBRATION
LEVELS BELOW 8 MILS.
5.508.2.1.3 FLARED TUBING CONNECTIONS. DOUBLE-FLARED TUHING
CONNECTIONS MAY BE USED FOR PRESSURE CONTROLS, VALVE
PILOT LINES AND OIL. WORK ORDER NO.
EXCEPTION: SINGLE-FLARED TUBING CONNECTIONS MAY BE USED
WITH A MULTIRING SEAL COATED WITH INDUSTRIAL SEALANT E170121B
(DESIGN STAGE ONLY)
A SHEET NAME
REVISION DATES
5.508.2.1.4
SPACE LIMITATIONS PROHIBIT USE OF LONG RADIUS ELBOWS.
A0.17
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A017_24X36.DWG 12/3/2021 9:07 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
11 AT DINING AND WORK SURFACES REQUIRED TO BE ACCESSIBLE, KNEE CLEARANCE SHALL EXTEND 19 6 IN EXISTING BUILDNGS THAT EXCEED 10,000 SQUARE FEET ON ANY FLOOR AND IN WHICH ELEVATORS DOORS, DOORWAYS AND GATES ENGINEERING
ARE REQUIRED BY 11B-206.2.3 MULTI-STORY BUILDINGS AND FACILITIES, WHEREEVER A NEWLY
COMMERCIAL ACCESSIBILITY NOTES (Based on the 2019 CALIFORNIA BUILDING CODE (CBC) and Chapter 11B-ACCESSIBILITY CONSTRUCTED MEANS OF VERTICAL ACCESS IS PROVIDED VIA STAIRS OR AN ESCALATOR, AN
TO PUBLIC BUILDINGS, PUBLIC ACCOMODATIONS AND COMMERCIAL BUILDINGS. ACCESSIBLE MEANS OF VERTICAL ACCESS VIA RAMP, ELEVATOR, OR LIFT SHALL BE PROVIDED WITHIN 29 DOORS, DOORWAYS, AND GATES PROVIDING USER PASSAGE SHALL BE PROVIDED IN ACCORDANCE WITH
PROTRUDING OBJECTS 11B-206.5
K
APPLICATION AND ADMINISTRATION 12 EXCEPT FOR HANDRAILS, OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES AND NOT MORE THAN 7 AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDING OR FACILITY ENTRANCES 30 DOORS, DOORWAYS AND GATES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH
80 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL PROTRUDE NO MORE THAN 4 INCHES WITH ALL ACCESSIBLE SPACES AND ELEMENTS WITHIN THE BUILDING OR FACILITY, INCLUDING
EXCEPTIONS 1 THROUGH 7)
THE STATE OF CALIFORNIA DELEGATES TO THE LOCAL JURISDICTION THE AUTHORITY TO ENSURE
COMPLIANCE WITH TITLE 24, PART 2 OF THE CALIFORNIA CODE OF REGULATIONS. THE OWNER(S) OF 31 REVOLVING DOORS, REVOLVING GATES, AND TURNSTILES SHALL NOT BE PART OF AN ACCESSIBLE
THIS BUILDING IS RESPONSIBLE FOR COMPLIANCE WITH THE MOST CURRENT FEDERAL REGULATIONS
CONTAINED IN THE AMERICANS WITH DISABILITIES ACT (ADA) AND FAIR HOUSING ACT (FHA). WHERE THE 13 FREE-STANDING OBJECTS MOUNTED ON POSTS OR PYLONS SHALL OVERHANG CIRCULATION PATHS NO 8 ACCESSIBLE ROUTES SHALL COINCIDE WITH OR BE LOCATED IN THE SAME AREA AS GENERAL
ADA & FHA REQUIREMENTS EXCEED THOSE CONTAINED IN TITLE 24, PART 2, IT IS THE OWNERS MORE THAN 12 INCHES WHEN LOCATED FROM 27 TO 80 INCHES ABOVE THE FINISH FLOOR OR GROUND. CIRCULATION PATHS. WHERE CIRCULATION PATHS ARE INTERIOR, REQUIRED ACCESSIBLE ROUTES
RESPONSIBILITY TO ENSURE COMPLIANCE WITH THE MOST CURRENT ADA & FHA REGULATIONS. SHALL ALSO BE INTERIOR; AN ACCESSIBLE ROUTE SHALL NOT PASS THROUGH KITCHENS, STORAGE 32 AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES SHALL COMPLY WITH
ROOMS, RESTROOMS, CLOSETS OR OTHER SPACES USED FOR SIMILAR PURPOSES, EXCEPT AS
J 14 PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH REQUIRED FOR ACCESSIBLE ROUTES.
33 DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES MINIMUM. CLEAR OPENINGS OF
A. APPLICATION AND ADMINISTRATION AND SCOPING REQUIREMENTS EMPLOYEE WORKSTATIONS DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE
STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 INCHES DEEP SHALL PROVIDE A
15 FREE-STANDING OBJECTS MOUNTED ON POSTS OR PYLONS SHALL OVERHANG CIRCULATION PATHS 12 CLEAR OPENING OF 36 INCHES MINIMUM. THERE SHALL BE NO PROJECTIONS INTO THE REQUIRED CLEAR
1 PUBLIC ACCOMMODATIONS SHALL MAINTAIN IN OPERABLE WORKING CONDITION THOSE FEATURES OF 9 EMPLOYEE WORKSTATIONS SHALL BE ON AN ACCESSIBLE ROUTE PER 11B-203.9. SPACES AND OPENING WIDTH LOWER THAN 34 INCHES ABOVE THE FINISH FLOOR OR GROUND. PROJECTIONS INTO
INCHES MAXIMUM WHEN LOCATED 27 INCHES MINIMUM AND 80 INCHES MAXIMUM ABOVE THE FINISH
FACILITIES AND EQUIPMENT THAT ARE REQUIRED TO BE ACCESSIBLE TO AND USEABLE BY PERSONS ELEMENTS WITHIN EMPLOYEE WORKSTATIONS SHALL ONLY BE REQUIRED TO COMPLY WITH SECTIONS THE CLEAR OPENING WIDTH BETWEEN 34 INCHES AND 80 INCHES ABOVE THE FINISH FLOOR OR GROUND 10/31/2023
WITH DISABILITIES. ISOLATED OR TEMPORARY INTERRUPTIONS IN SERVICE OR ACCESSIBILITY DUE TO 11B-207.1 (MEANS OF EGRESS), 11B-215.3 (AUDIBLE ALARM COVERAGE), 11B-302 (FLOOR OR GROUND
SURAFCES), 11B- 303 (CHANGES IN LEVEL), 11-B-308.1.1 (ELECTRICAL SWITCHES), 11B-308.1.2 MAXIMUM INTO THE REQUIRED CLEAR WIDTH SHALL BE PERMITTED FOR THE LATCH-SIDE STOP,
(ELECTRICAL RECEPTACLE OUTLETS) AND 11B-404.2.3 (DOOR CLEAR WIDTH) UNLESS EXEMPTED BY EXCEPTION 2: DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES MINIMUM
16 VERTICAL CLEARANCE SHALL BE 80 INCHES HIGH MINIMUM. GUARDRAILS OR OTHER BARRIERS SHALL BE
OTHER PARTS OF THE CODE. COMMON USE CIRCULATION PATHS WITHIN EMPLOYEE WORKSTATIONS ABOVE THE FINISH FLOOR OR GROUND.
PROVIDED WHERE THE VERTICAL CLEARANCE IS LESS THAN 80 INCHES HIGH. THE LEADING EDGE OF
2 WHEN ALTERATIONS OR ADDITIONS ARE MADE TO EXISTING BUILDINGS OR FACILITIES, AN ACCESSIBLE
SUCH GUARDRAIL OR BARRIER SHALL BE LOCATED 27 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR
PATH OF TRAVEL TO THE SPECIFIC AREA OF ALTERATION OR ADDITION SHALL BE PROVIDED UNLESS
GROUND. DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES MINIMUM ABOVE
OTHERWISE EXEMPT. PRIMARY ACCESSIBLE PATH OF TRAVEL SHALL INCLUDE A PRIMARY ENTRANCE TO 34 MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL COMPLY WITH 11B-404.2.4.
I THE BUILDING OR FACILITY; TOILET AND BATHING FACILITIES SERVING THE AREA; DRINKING FOUNTAINS MACHINERY SPACES MANEUVERING CLEARANCES SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED
17 WHERE A GUY SUPPORT IS USED WITHIN EITHER THE WIDTH OF A CIRCULATION PATH OR 24 INCHES
11 OMIT.
ACCESSIBILITY NOTES
DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE WITHIN 18 INCHES OF THE LATCH SIDE AN INTERIOR DOORWAY, OR WITHIN 24 INCHES OF THE LATCH
SIDE OF AN EXTERIOR DOORWAY, PROJECTS MORE THAN 8 INCHES BEYOND THE FACE OF THE DOOR,
5 IN CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE 19 ELECTRICAL CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF A ROOM OR AREA
TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND 12 ALL REQUIRED DETECTABLE WARNINGS ON SHALL BE IN COMPLIANCE WITH THE SELECTED ITEMS
ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS IN THE FOLLOWING ORDER: 1)AN ACCESSIBLE
ENTRANCE; 2)AN ACCESSIBLE ROUTE TO THE ALTERED AREA; 3)AT LEAST ONE ACCESSIBLE RESTROOM VENTILATING EQUIPMENT SHALL BE LOCATED WITHIN ALLOWABLE REACH RANGES EXCEPT THE LOW
REACH SHALL BE MEASURED TO THE BOTTOM OF THE OUTLET BOX AND HIGH REACH SHALL BE 38
FOR EACH SEX OR A SINGLE ACCESSIBLE UNISEX RESTROOM; 4)ACCESSIBLE TELEPHONES; 13 CURB RAMPS SHALL HAVE DETECTABLE WARNINGS THAT EXTEND 36 INCHES IN THE DIRECTION OF CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND SURFACES AND
5)ACCESSIBLE DRINKING FOUNTAINS; AND 6)WHEN POSSIBLE, ADDITIONAL ACCESSIBLE ELEMENTS SUCH TRAVEL FOR THE FULL WIDTH OF THE RAMP RUN LESS THAN 2 INCHES MAXIMUM ON EACH SIDE,
20 ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND ON PERPENDICULAR CURB RAMPS, DETECTABLE WARNINGS SHALL BE LOCATED SO THE EDGE NEAREST
HORIZONTAL CONTROL:
COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED WITHIN ALLOWABLE REACH RANGES THE CURB IS 6 INCHES MINIMUM AND 8 INCHES MAXIMUM FROM THE LINE AT THE FACE OF THE CURB 39 HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL
6 ALTERATIONS TO QUALIFIED HISTORIC BUILDING OR FACILITY SHALL COMPLY WITH CHAPTER 11B
COMPLY WITH 11B-309.4 OPERATION. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES
VERTICAL CONTROL:
UNLESS IT WILL THREATEN OR DESTROY THE HISTORICAL SIGNIFICANCE OR CHARACTER-DEFINING EXCEPT THE LOW REACH SHALL BE MEASURED TO THE BOTTOM OF THE OUTLET BOX AND HIGH REACH
MINIMUM AND 44 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. WHERE SLIDING DOORS ARE
FEATURES OF THE BUILDING OR PROPERTY. IN THOSE CASES, ALTERNATIVE PROVISIONS SHALL BE
G APPLIED ON AN ITEM-BY-ITEM OR CASE-BY-CASE BASIS WITH SUFFICIENT WRITTEN DOCUMENTATION. ON PARALLEL CURB RAMPS, DETECTABLE WARNINGS SHALL BE PLACED ON THE TURNING SPACE AT THE
IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH
SHEET TITLE:
FLUSH TRANSITION BETWEEN THE STREET AND SIDEWALK. DETECTABLE WARNINGS SHALL EXTEND THE
ADDRESS:
PROJECT:
21 HIGH FORWARD REACH THAT IS UNOBSTRUCTED SHALL BE 48 INCHES MAXIMUM AND THE LOW FULL WIDTH OF THE TURNING SPACE AT THE FLUSH TRANSITION BETWEEN THE STREET AND THE
FIGURE 11B-308.2.1 40
7 FOR NEW CONSTRUCTION, AT LEAST ONE ACCESSBILE ROUTE SHALL BE PROVIDED WITHIN THE SITE
14 ISLANDS OR CUT-THROUGH MEDIANS SHALL HAVE DETECTABLE WARNINGS THAT ARE 36 INCHES
FROM ACCESSIBLE PARKING SPACES AND ACCESSIBLE PASSENGER DROP-OFF AND LOADING ZONES,
MINIMUM IN DEPTH EXTENDING THE FULL WIDTH OF THE PEDESTRIAN PATH OR CUT-THROUGH LESS 2
PUBLIC STREETS AND SIDEWALKS AND PUBLIC TRANSPORTATION STOPS TO THE ACCESSIBLE BUILDING
22 HIGH FORWARD REACH SHALL BE 48 INCHES MAXIMUM WHERE THE REACH DEPTH IS 20 INCHES INCHES MAXIMUM ON EACH SIDE, PLACED AT THE EDGES OF THE PEDESTRIAN ISLAND OR CUT-THROUGH a. INTERIOR HINGED DOORS AND GATES: 5 POUNDS MAXIMUM.
OR FACILITY ENTRANCE THEY SERVE. WHERE MORE THAN ONE ROUTE IS PROVIDED, ALL ROUTES MUST
MEDIAN, AND SHALL BE SEPARATED BY 24 INCHES MINIMUM OF WALKING SURFACE WITHOUT
BY:
15 WALKS THAT CROSS OR ADJOIN A ROUTE PROVIDED FOR VEHICULAR TRAFFIC, SUCH AS IN A STREET, b. SLIDING OR FOLDING DOORS: 5 POUNDS MAXIMUM.
DATE:
CIP NO.
DRIVEWAY, OR PARKING FACILITY, SHALL BE SEPARATED BY DETECTABLE WARNINGS, CURBS, RAILINGS
23 HIGH SIDE REACH SHALL BE 48 INCHES MAXIMUM AND THE LOW SIDE REACH SHALL BE 15 INCHES
B. BUILDING BLOCKS
F MINIMUM ABOVE THE FINISH FLOOR WHERE THE SIDE REACH IS UNOBSTRUCTED OR THE DEPTH OF ANY c. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE
ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS.
16 DETECTABLE WARNINGS PROVIDED TO SEPARATE WALKS THAT CROSS OR ADJOIN A ROUTE PROVIDED
FLOOR OR GROUND SURFACES FOR VEHICULAR TRAFFIC, SUCH AS IN A STREET, DRIVEWAY, OR PARKING FACILITY, SHALL BE 36 INCHES
IN WIDTH AND CONTINUOUS AT THE BOUNDARY BETWEEN THE PEDESTRIAN AREAS AND VEHICULAR
24 WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE d. EXTERIOR HINGED DOORS: 5 POUNDS MAXIMUM.
HIGH SIDE REACH IS OVER AN OBSTRUCTION, THE HEIGHT OF THE OBSTRUCTION SHALL BE 34 INCHES
1 MAXIMUM AND THE DEPTH OF THE OBSTRUCTION SHALL BE 24 INCHES MAXIMUM. THE HIGH SIDE REACH DETECTABLE WARNINGS SHALL CONSIST OF TRUNCATED DOMES PER 11B-705 AND SHALL BE SPACED
SHALL BE 48 INCHES MAXIMUM FOR A REACH DEPTH OF 10 INCHES MAXIMUM. WHERE THE REACH DEPTH PER 11B-705.1.1.2. DETECTABLE WARNING SURFACES SHALL BE YELLOW AND APPROXIMATE FS 33538 OF
41 SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FINISH FLOOR OR GROUND MEASURED
EXCEEDS 10 INCHES, THE HIGH SIDE REACH SHALL BE 46 INCHES MAXIMUM FOR A REACH DEPTH OF 24
VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE
2 CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD, OR DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACES SHALL BE
BACKING OR NO CUSHION OR PAD. CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP, TEXTURED WITHIN 1/16 INCH OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES.
ENTRANCES
25 EXCEPTION 1- THE TOP OF WASHING MACHINES AND CLOTHES DRYERS SHALL BE PERMITTED TO BE 36
E 17 ENTRANCES SHALL BE PROVIDED IN ACCORDANCE WITH 11B-206.4. ALL ENTRANCES, ENTRANCE DOORS, RAMPS
CHANGES IN LEVEL DOORWAYS, AND GATES AND ALL EXTERIOR GROUND-FLOOR EXITS TO BUILDINGS AND FACILITIES SHALL
26 EXCEPTION 2- OPERABLE PARTS OF FUEL DISPENSERS SHALL BE PERMITTED TO BE 54 INCHES MAXIMUM COMPLY WITH 11B-404, EXCEPT EXTERIOR GROUND FLOOR EXITS SERVING SMOKE-PROOF ENCLOSURES,
MEASURED FROM THE SURFACE OF THE VEHICULAR WAY WHERE FUEL DISPENSERS ARE INSTALLED ON STAIRWELLS AND EXIT DOORS SERVING STAIRS ONLY. ENTRANCE DOORS, DOORWAYS, AND GATES AND
42 RAMPS ON ACCESSIBLE ROUTES SHALL COMPLY WITH 11B-405.2 FOR SLOPE, WIDTH, RISE, LANDINGS,
3
REVISIONS:
HANDRAILS, EDGE PROTECTION AND WET CONDITIONS.
11B-303.3 OPERABLE PARTS 19 DOORS, DOORWAYS AND GATES PROVIDING USER PASSAGE SHALL COMPLY WITH 11B-206.5 AND 11B-404
INDEX NO.
43
INCLUDING DOOR SIZE(S), HARDWARE, LANDINGS, THRESHOLDS, KICKPLATES, OPENING FORCE,
NO.
4 28 OPERABLE PARTS SHALL BE PLACED WITHIN ON OR MORE OF THE ACCESSIBLE REACH RANGES AND
44
SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR
TWISTING OF THE WRIST. FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS 20 WHERE DIRECT ACCESS IS PROVIDED FOR PEDESTRIANS FROM A PARKING STRUCTURE TO A BUILDING
D OR FACILITY ENTRANCE, EACH DIRECT ACCESS TO THE BUILDING OR FACILITY ENTRANCE SHALL
45 FLOOR OR GROUND SURFACES OF RAMP RUNS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND
CITY ENGINEER
5 ABRUPT CHANGES IN LEVEL EXCEEDING 4 INCHES IN A VERTICAL DIMENSION BETWEEN WALKS,
DATE:
SURFACES. CHANGES IN LEVEL OTHER THAN THE RUNNING SLOPE AND CROSS SLOPE ARE NOT
SIDEWALKS OR OTHER PEDESTRIAN WAYS AND ADJACENT SURFACES OR FEATURES SHALL BE
IDENTIFIED BY WARNING CURBS AT LEAST 6 INCHES IN HEIGHT ABOVE THE WALK OR SIDEWALK C. ACCESSIBLE ROUTES
SURFACE OR BY GUARDS OR HANDRAILS WITH A GUIDE RAIL CENTERED 2 INCHES MINIMUM AND 4 21 DIRECT CONNECTIONS TO OTHER FACILITIES SHALL PROVIDE AN ACCESSIBLE ROUTE COMPLYING WITH
INCHES MAXIMUM ABOVE THE SURFACE OF THE WALK OR SIDEWALK. THESE REQUIREMENTS DO NOT 11B-404 DOORS, DOORWAYS, AND GATES FROM THE POINT OF CONNECTION TO BOARDING PLATFORMS
AND ALL TRANSPORTATION SYSTEM ELEMENTS REQUIRED TO BE ACCESSIBLE. ANY ELEMENTS 46
GENERAL
PROVIDED TO FACILITATE FUTURE DIRECT CONNECTIONS SHALL BE ON AN ACCESSIBLE ROUTE HANDRAILS MAY PROJECT INTO THE REQUIRED CLEAR RAMP WIDTH AT EACH SIDE 3.5 INCHES MAXIMUM
CONNECTING BOARDING PLATFORMS AND ALL TRANSPORTATION SYSTEM ELEMENTS REQUIRED TO BE AT HANDRAIL HEIGHT.
TURNING SPACE 1 AT LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED WITHIN THE SITE FROM ACCESSIBLE PARKING
SPACES AND ACCESSIBLE PASSENGER LOADING ZONES; PUBLIC STREETS AND SIDEWALKS; AND PUBLIC 47
TRANSPORTATION STOPS TO THE ACCESSIBLE BUILDING OR FACILITY ENTRANCE THEY SERVE. WHERE
6 CIRCULAR TURNING SPACES SHALL BE A SPACE OF 60 INCHES DIAMETER MINIMUM AND MAY INCLUDE TECHNICAL REQUIREMENTS FOR ACCESSIBLE ROUTES
C AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED BETWEEN SITE ARRIVAL POINTS AND THE BUILDING OR
48
FACILITY ENTRANCE IF THE ONLY MEANS OF ACCESS BETWEEN THEM IS A VEHICULAR WAY NOT
DESIGN GROUP
PROVIIDNG PEDESTRIAN ACCCES. GENERAL CIRCULATION PATHS SHALL BE PERMITTED WHEN LOCATED 22 ACCESSIBLE ROUTES SHALL CONSIST OF ONE OR MORE OF THE FOLLOWING COMPONENTS: WALKING
7 T-SHAPED TURNING SPACES SHALL BE A T-SHAPED SPACE WITHIN A 60 INCH SQUARE MINIMUM WITH IN CLOSE PROXIMITY TO AN ACCESSIBLE ROUTE. SURFACES WITH A RUNNING SLOPE NOT STEEPER THAN 1:20 (5%), DOORWAYS, RAMPS, CURB RAMPS
ARMS AND BASE 36 INCHES WIDE MINIMUM. EACH ARM OF THE T SHALL BE CLEAR OF OBSTRUCTIONS 12 49 LANDINGS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND SURFACES. CHANGES IN LEVEL ARE NOT
INCHES MINIMUM IN EACH DIRECTION AND THE BASE SHALL BE CLEAR OF OBSTRUCTIONS 24 INCHES
2 AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGS, ACCESSIBLE FACILITIES,
23 THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE STEEPER THAN 1:20 (5%). THE CROSS
EXCEPTION: AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED BETWEEN ACCESSIBLE BUILDINGS, 50 THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE WIDEST RAMP RUN LEADING TO THE
ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS AND ACCCESSIBLE SPACES IF THE ONLY MEANS OF
KNEE AND TOE CLEARANCE
ACCESS BETWEEN THEM IS A VEHICULAR WAY NOT PROVIIDNG PEDESTRIAN ACCESS.
52
APPROVED BY:
DESIGNED BY:
CHECKED BY:
25 THE CLEAR WIDTH FOR WALKING SURFACES IN CORRIDORS SERVING AN OCCUPANT LOAD OF 10 OR
DRAWN BY:
ENGINEER:
4 IN ALTERATIONS OR ADDITIONS, WHERE AN ESCALATOR OR STAIR IS PROVIDED WHERE NONE EXISTED
9 TOE CLEARANCE SHALL EXTEND 25 INCHES MAXIMUM UNDER AN ELEMENT. TOE CLEARANCE SHALL PREVIOUSLY AND MAJOR STRUCTURAL MODIFICATIONS ARE NECESSARY FOR THE INSTALLATION, AN
EXTEND 19 INCHES MAXIMUM UNDER LAVATORIES REQUIRED TO BE ACCESSIBLE PER 11B-213.3.4. 53
ACCESSIBLE ROUTE SHALL BE PROVIDED BETWEEN THE LEVELS SERVED BY THE ESCALATOR OR STAIR
UNLESS EXEMPTED BY 11B-206.2.3 EXCEPTIONS 1-7.
26
54 RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR LANDING 60
10 WHERE KNEE CLEARANCE IS REQUIRED UNDER AN ELEMENT AS PART OF A CLEAR FLOOR SPACE, THE 5 IN NEW CONSTRUCTION OF BUILDINGS WHERE ELEVATORS ARE REQUIRED BY 11B-206.2.3 MULTI-STORY INCHES MINIMUM BY 72 INCHES MINIMUM IN THE DIRECTION OF DOWNWARD TRAVEL FROM THE UPPER
WORK ORDER NO.
KNEE CLEARANCE SHALL BE 11 INCHES DEEP MIN. AT 9 INCHES ABOVE THE FINISH FLOOR OR GROUND BUILDINGS AND FACILITIES, AND WHICH EXCEED 10,000 SQUARE FEET ON ANY FLOOR, AN ACCESSIBLE 27 THE CLEAR WIDTH FOR AISLES SHALL BE 36 INCHES MINIMUM IF SERVING ELEMENTS ON ONLY ONE SIDE,
AND 8 INCHES DEEP MIN. AT 27 INCHES ABOVE THE FINISH FLOOR OR GROUND. AT LAVATORIES
REQUIRED TO BE ACCESSIBLE BY SECTION 11B-213.3.4, THE KNEE CLEARNCE SHALL BE 27 INCHES HIGH
MEAN OF VERTICAL ACCESS VIA RAMP, ELEVATOR OR LIFT SHALL BE PROVIDED WITH IN 200 FEET OF E170121B
(DESIGN STAGE ONLY)
MINIMUM ABOVE THE FINISH FLOOR OR GROUND AT A DEPTH OF 8 INCHES MIN. INCREASING TO 29
A INCHES HIGH MIN. AT THE FRONT EDGE OF A COUNTER WITH A BUILT-IN LAVATORY OR AT THE FRONT 28 THE CLEAR WIDTH FOR ACCESSIBLE ROUTES TO ACCESSIBLE TOILET COMPARTMENTS SHALL BE 44
55 WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES
REQUIRED BY 11B-404.2.4 AND 11B-404.3.2 SHALL BE PERMITTED TO OVERLAP THE REQUIRED LANDING SHEET NAME
REVISION DATES
AREA. DOORS, WHEN FULLY OPEN, SHALL NOT REDUCE THE REQUIRED RAMP LANDING WIDTH BY MORE
THAN 3 INCHES. DOORS, IN ANY POSITION, SHALL NOT REDUCE THE MINIMUM DIMENSION OF THE RAMP
A0.20
X X
COMMERCIAL ACCESSIBILITY NOTES CONTINUE ON SHEET A0.21 SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A020_24X36.DWG 12/3/2021 9:07 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
80 PERPENDICULAR RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12 (8.33%). 13 CAR AND VAN STALL ACCESS AISLE SHALL BE 5 FOOT WIDE MINIMUM AND SHALL ADJOIN AN ACCESSIBLE 32 VEHICLE PULL-UP SPACES, ACCESS AISLES SERVING THEM, AND A VEHICULAR ROUTE FROM AN ENGINEERING
ENTRANCE TO THE PASSENGER LOADING ZONE AND FROM THE PASSENGER LOADING ZONE TO A
56 FIGURES 11B-502.2 AND 11B-502.3. VEHICULAR EXIT SHALL PROVIDE A VERTICAL CLEARANCE OF 114 INCHES (9 FEET, 6 INCHES) MINIMUM.
CURB RAMPS DO NOT REQUIRE HANDRAILS AND PER EXCEPTION 4, AT DOOR LANDINGS, HANDRAILS ARE
NOT REQUIRED ON RAMP RUNS LESS THAN 6 INCHES IN RISE OR 72 INCHES IN LENGTH.
81 FOR PERPENDICULAR RAMPS, WHERE PROVIDED, CURB RAMP FLARES SHALL NOT BE STEEPER THAN
K 14 ACCESS AISLES SHALL BE MARKED WITH A BLUE PAINTED BORDERLINE AROUND THEIR PERIMETER. THE
AREA WITHIN THE BLUE BORDERLINES SHALL BE MARKED WITH HATCHED LINES A MAXIMUM OF 36 33 EACH PASSENGER LOADING ZONE DESIGNATED FOR PERSONS WITH DISABILITIES SHALL BE IDENTIFIED
57 EDGE PROTECTION COMPLYING WITH 11B-405.9.2 CURB OR BARRIER SHALL BE PROVIDED ON EACH SIDE INCHES ON CENTER IN A COLOR CONTRASTING WITH THAT OF THE AISLE SURFACE, PREFERABLY BLUE WITH A REFLECTORIZED SIGN COMPLYING WITH SECTION 11B-703.5 VISUAL CHARACTERS. IT SHALL BE
OR WHITE. THE WORDS "NO PARKING" SHALL BE PAINTED ON THE SURFACE WITHIN EACH ACCESS AISLE PERMANENTLY POSTED IMMEDIATELY ADJACENT TO AND VISIBLE FROM THE PASSENGER LOADING ZONE
82 THE RUNNING SLOPE OF THE CURB RAMP SEGMENTS SHALL BE IN-LINE WITH THE DIRECTION OF
IN WHITE LETTERS A MINIMUM OF 12 INCHES IN HEIGHT AND LOCATED TO BE VISIBLE FROM THE
SIDEWALK TRAVEL. RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12 (8.33%).
ADJACENT VEHICULAR WAY. ACCESS AISLE MARKINGS MAY EXTEND BEYOND THE MINIMUM REQUIRED ACCESSIBILITY (ISA) COMPLYING WITH SECTION 11B-703.7.2.1 ISA.
58 A CURB OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE PASSAGE OF A 4 INCH DIAMETER
SPHERE, WHERE ANY PORTION OF THE SPHERE IS WITHIN 4 INCHES OF THE FINISH FLOOR OR GROUND
SURFACE. TO PREVENT WHEEL ENTRAPMENT, THE CURB OR BARRIER SHALL PROVIDE A CONTINUOUS
83 A TURNING SPACE 48 INCHES MINIMUM BY 48 INCHES MINIMUM SHALL BE PROVIDED AT THE BOTTOM OF E. PLUMBING FIXTURES AND FACILITIES
15 ACCESS AISLES SHALL NOT OVERLAP THE VEHICULAR WAY. ACCESS AISLES SHALL BE PERMITTED TO BE
THE CURB RAMP. THE SLOPE OF THE TURNING SPACE IN ALL DIRECTIONS SHALL BE 1:48 MAXIMUM
PLACED ON EITHER SIDE OF THE PARKING SPACE EXCEPT FOR VAN PARKING SPACES WHICH SHALL
DRINKING FOUNTAINS
59 LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF
J 84
16 PARKING SPACES AND ACCESS AISLES SERVING THEM SHALL COMPLY WITH SECTION 11B-302. PROVIDE
1 WHERE DRINKING FOUNTAINS ARE PROVIDED, NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE
A MINIMUM VERTICAL CLEARANCE OF 8 FEET 2 INCHES AND ALONG AT LEAST ONE VEHICLE ACCESS
PROVIDED. WHEN PROVIDED, ONE DRINKING FOUNTAIN SHALL COMPLY WITH 11B-602.1 THROUGH
HANDRAILS
85 CURB RAMPS AND THE FLARED SIDES OF CURB RAMPS SHALL BE LOCATED SO THAT THEY DO NOT 11B-602.6, 11B-602.8 AND 11B- 602.9 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH 11B- 602.7 AND
PROJECT INTO VEHICULAR TRAFFIC LANES, PARKING SPACES, OR PARKING ACCESS AISLES. CURB
RAMPS AT MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY 11B-602.1THROUGH 11B-602.9, IT SHALL BE PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE
60 17 PARKING SPACE IDENTIFICATION SIGNS SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY DRINKING FOUNTAINS. 10/31/2023
COMPLYING WITH SECTION 11B-703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY, IN WHITE ON A
61 HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF EACH STAIR FLIGHT OR RAMP RUN. 2 WHERE MORE THAN THE MINIMUM NUMBER OF DRINKING FOUNTAINS SPECIFIED IN 11B-211.2 ARE
86 THE CLEAR WIDTH OF CURB RAMP RUNS (EXCLUDING ANY FLARED SIDES), BLENDED TRANSITIONS, AND
INSIDE HANDRAILS ON SWITCHBACK OR DOGLEG STAIRS AND RAMPS SHALL BE CONTINUOUS BETWEEN PROVIDED, 50 PERCENT OF THE TOTAL NUMBER OF DRINKING FOUNTAINS PROVIDED SHALL COMPLY
18 SIGNS IDENTIFYING VAN PARKING SPACES SHALL CONTAIN ADDITIONAL LANGUAGE OR AN ADDITIONAL WITH 11B-602.1 THROUGH 11B- 602.6, 11B-602.8 AND 11B-602.9, AND 50 PERCENT OF THE TOTAL NUMBER
EXCEPTION)
I 62 TOP OF GRIPPING SURFACES OF HANDRAILS SHALL BE 34 INCHES MINIMUM AND 38 INCHES MAXIMUM
87 LANDINGS SHALL BE PROVIDED AT THE TOPS OF CURB RAMPS AND BLENDED TRANSITIONS (PARALLEL
CURB RAMPS SHALL NOT BE REQUIRED TO COMPLY). THE LANDING CLEAR LENGTH SHALL BE 48 INCHES
VERTICALLY ABOVE WALKING SURFACES, STAIR NOSINGS, AND RAMP SURFACES. HANDRAILS SHALL BE
MINIMUM. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE CURB RAMP, EXCLUDING ANY
AT A CONSISTENT HEIGHT ABOVE WALKING SURFACES, STAIR NOSINGS, AND RAMP SURFACES. 19 PARKING IDENTIFICATION SIGNS SHALL BE REFLECTORIZED WITH A MINIMUM AREA OF 70 SQUARE 3 DRINKING FOUNTAINS SHALL COMPLY WITH SECTIONS 11B-307 PROTRUDING OBJECTS AND 11B-602
FLARED SIDES, OR THE BLENDED TRANSITION LEADING TO THE LANDING. THE SLOPE OF THE LANDING IN
21 A PARKING SPACE IDENTIFICATION SIGN SHALL BE VISIBLE FROM EACH PARKING SPACE. SIGNS SHALL BE
64 HANDRAIL GRIPPING SURFACES SHALL BE CONTINUOUS ALONG THEIR LENGTH AND SHALL NOT BE PERMANENTLY POSTED EITHER IMMEDIATELY ADJACENT TO THE PARKING SPACE OR WITHIN THE 5 UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B-305 CLEAR
ACCESSIBILITY NOTES
22 EACH ACCESSIBLE CAR AND VAN SPACE SHALL HAVE SURFACE IDENTIFICATION COMPLYING WITH
90 COUNTER SLOPES OF ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO AND
6 WHERE DRINKING FOUNTAINS ARE USED BY CHILDREN, A PARALLEL APPROACH COMPLYING WITH
WITHIN 24 INCHES OF THE CURB RAMP SHALL NOT BE STEEPER THAN 1:20 (5%). THE ADJACENT
65 HANDRAIL GRIPPING SURFACES WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER SECTION 11B-305 CLEAR FLOOR OR GROUND SURFACES SHALL BE PERMITTED AT UNITS WHERE THE
SURFACES AT TRANSITIONS AT CURB RAMPS TO WALKS, GUTTERS, AND STREETS SHALL BE AT THE
HORIZONTAL CONTROL:
ACTIVE TRAFFIC LANES OF THE ROADWAY. DIAGONAL CURB RAMPS PROVIDED AT MARKED CROSSINGS
SPACE, ITS SIDES PARALLEL TO THE LENGTH OF THE PARKING SPACE AND ITS LOWER CORNER AT, OR
VERTICAL CONTROL:
G 67 HANDRAIL GRIPPING SURFACES SHALL EXTEND BEYOND AND IN THE SAME DIRECTION OF STAIR FLIGHTS
8 THE SPOUT SHALL BE LOCATED 15 INCHES MINIMUM FROM THE VERTICAL SUPPORT AND 5 INCHES
SHEET TITLE:
92 CURB RAMPS AND BLENDED TRANSITIONS SHALL HAVE DETECTABLE WARNINGS COMPLYING WITH
b. THE PARKING SPACE SHALL BE OUTLINED OR PAINTED BLUE AND SHALL BE MARKED WITH AN
ADDRESS:
PROJECT:
EXCEPTION 1: EXTENSIONS ARE NOT REQUIRED FOR CONTINUOUS HANDRAILS AT THE INSIDE OF INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1, A MINIMUM 36
SWITCHBACK OR DOGLEG STAIRS AND RAMPS. (SEE OTHER EXCEPTIONS) INCHES WIDE BY 36 INCHES HIGH IN WHITE OR A SUITABLE CONTRASTING COLOR. THE CENTERLINE OF 9 THE SPOUT SHALL PROVIDE A FLOW OF WATER 4 INCHES HIGH MINIMUM AND SHALL BE LOCATED 5
THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE A MAXIMUM OF 6 INCHES FROM THE INCHES MAXIMUM FROM THE FRONT OF THE UNIT. THE ANGLE OF THE WATER STREAM SHALL BE
93 RAISED ISLANDS IN CROSSINGS SHALL BE CUT THROUGH LEVEL WITH THE STREET OR HAVE CURB CENTERLINE OF THE PARKING SPACE, ITS SIDES PARALLEL TO THE LENGTH OF THE PARKING SPACE AND MEASURED HORIZONTALLY RELATIVE TO THE FRONT FACE OF THE UNIT. WHERE SPOUTS ARE LOCATED
RAMPS AT BOTH SIDES. THE CLEAR WIDTH OF THE ACCESSIBLE ROUTE AT ISLANDS SHALL BE 60 INCHES
68 IN ALTERATIONS, WHERE THE EXTENSION OF THE HANDRAIL IN THE DIRECTION OF STAIR FLIGHT OR LESS THAN 3 INCHES FROM THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL BE 30
WIDE MINIMUM. WHERE CURB RAMPS ARE PROVIDED, THEY SHALL COMPLY WITH 11B-406 CURB RAMPS,
RAMP RUN WOULD CREATE A HAZARD, THE EXTENSION OF THE HANDRAIL MAY BE TURNED 90 DEGREES DEGREES MAXIMUM. WHERE SPOUTS ARE LOCATED BETWEEN 3 INCHES AND 5 INCHES MAXIMUM FROM
BY:
THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL BE 15 DEGREES MAXIMUM.
ROUTE SHALL BE PERMITTED TO OVERLAP. ISLANDS SHALL HAVE DETECTABLE WARNINGS COMPLYING
23 AN ADDITIONAL SIGN SHALL BE POSTED EITHER; 1) IN A CONSPICUOUS PLACE AT EACH ENTRANCE TO AN
OFF-STREET PARKING FACILITY OR 2) IMMEDIATELY ADJACENT TO ON-SITE ACCESSIBLE PARKING AND
DATE:
CIP NO.
69 RAMP HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR 12 INCHES MINIMUM BEYOND
THE TOP AND BOTTOM OF RAMP RUNS. EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR THE 10 SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES MINIMUM AND
F LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN.
D. GENERAL SITE AND BUILDING ELEMENTS
a.
PARKING SPACES
11 WALL- AND POST-MOUNTED CANTILEVERED DRINKING FOUNTAINS SHALL BE 18 INCHES MINIMUM AND 19
70 AT THE TOP OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR 12 b. THE ADDITIONAL SIGN SHALL CLEARLY STATE IN LETTERS WITH A MINIMUM HEIGHT OF 1 INCH THE
INCHES MINIMUM BEGINNING DIRECTLY ABOVE THE FIRST RISER NOSING. EXTENSIONS SHALL RETURN
TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN 1 WHERE PARKING SPACES ARE PROVIDED, ACCESSIBLE PARKING SPACES SHALL BE PROVIDED IN DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH
12 ALL DRINKING FOUNTAINS SHALL EITHER BE LOCATED COMPLETELY WITHIN ALCOVES, POSITIONED
OF THIS SECTION, ELECTRIC VEHICLE CHARGING STATIONS ARE NOT PARKING SPACES. AT: _________________________ OR BY TELEPHONING_______________________." BLANK SPACES SHALL COMPLETELY BETWEEN WING WALLS, OR OTHERWISE POSITIONED SO AS NOT TO ENCROACH INTO
BE FILLED IN WITH APPROPRIATE INFORMATION AS A PERMANENT PART OF THE SIGN. PEDESTRIAN WAYS. THE PROTECTED AREA WITHIN SUCH A DRINKING FOUNTAIN IS LOCATED SHALL BE
71 AT THE BOTTOM OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND AT THE SLOPE OF THE STAIR FLIGHT 32 INCHES WIDE MINIMUM AND 18 INCHES DEEP MINIMUM, AND SHALL COMPLY WITH SECTION 11B-305.7
FOR A HORIZONTAL DISTANCE EQUAL TO ONE TREAD DEPTH BEYOND THE LAST RISER NOSING. THE 2 MANEUVERING CLEARANCE. WHEN USED, WING WALLS OR BARRIERS SHALL PROTECT HORIZONTALLY
HORIZONTAL EXTENSION OF A HANDRAIL SHALL BE 12 INCHES LONG MINIMUM AND A HEIGHT EQUAL TO 24 SIGNS INTENDED FOR USE BY PEDESTRIANS WITHIN PARKING FACILITIES, INCLUDING DIRECTIONAL OR AT LEAST AS FAR AS THE DRINKING FOUNTAIN AND TO WITHIN 6 INCHES VERTICALLY FROM THE FLOOR
E THAT OF THE SLOPING PORTION OF THE HANDRAIL AS MEASURED ABOVE THE STAIR NOSINGS. INFORMATIONAL SIGNS INDICATING PARKING SECTIONS OR LEVELS, SHALL COMPLY WITH THE
EXTENSION SHALL RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS 3 PROVIDE ACCESSIBLE SPACES FOR EACH PARKING FACILITY (PARKING LOTS AND PARKING
STRUCTURES). THE NUMBER OF PARKING SPACES REQUIRED TO BE ACCESSIBLE IS TO BE CALCULATED
SEPARATELY FOR EACH PARKING FACILITY; THE REQUIRED NUMBER IS NOT BASED ON THE TOTAL TOILET AND BATHING ROOM CLEARANCES
NUMBER OF PARKING SPACES PROVIDED IN ALL OF THE PARKING FACILITIES PROVIDED ON SITE. RELATIONSHIP TO ACCESSIBLE ROUTES
REVISIONS:
STAIRWAYS
13 WHERE TOILET FACILITIES AND BATHING FACILITIES ARE PROVIDED, THEY SHALL COMPLY WITH 11B-213.
25 PARKING SPACES AND ACCESS AISLES SHALL BE DESIGNED SO THAT PERSONS USING THEM ARE NOT WHERE TOILET FACILITIES AND BATHING FACILITIES ARE PROVIDED IN FACILITIES PERMITTED BY
INDEX NO.
72 A STAIR IS DEFINED AS A CHANGE IN ELEVATION, CONSISTING OF ONE OR MORE RISERS PER CHAPTER 2, 4 OMIT. REQUIRED TO TRAVEL BEHIND PARKING SPACES OTHER THAN TO PASS BEHIND THE PARKING SPACE IN 11B-206.2.3 MULTI-STORY BUILDINGS AND FACILITIES EXCEPTIONS 1, NOT TO CONNECT STORIES BY AN
SECTION 202. ACCESSIBLE ROUTE, TOILET FACILITIES AND BATHING FACILITIES SHALL BE PROVIDED ON A STORY
NO.
5 PARKING SPACES PROVIDED FOR GUESTS, EMPLOYEES AND NON-RESIDENTS SHALL COMPLY WITH
73 ALL STEPS ON A FLIGHT OF STAIRS SHALL HAVE UNIFORM RISER HEIGHTS AND UNIFORM TREAD DEPTHS. TABLE 11B-208.2. WHEN ASSIGNED PARKING IS PROVIDED, CHAPTER 11A INDICATES DESIGNATED 26 A CURB OR WHEEL STOP SHALL BE PROVIDED IF REQUIRED TO PREVENT ENCROACHMENT OF VEHICLES
ACCESSIBLE PARKING FOR THE ADAPTABLE RESIDENTIAL DWELLING UNITS SHALL BE PROVIDED ON
D RISERS SHALL BE 4 INCHES HIGH MINIMUM AND 7 INCHES HIGH MAXIMUM. TREADS SHALL BE 11 INCHES
DEEP MINIMUM. CURVED STAIRWAYS WITH WINDER TREADS ARE PERMITTED AT STAIRS WHICH ARE NOT REQUESTS OF RESIDENTS WITH DISABILITES ON THE SAME TERMS AND WITH THE FULL RANGE OF
14 WHERE SEPARATE TOILET FACILITIES ARE PROVIDED FOR THE EXCLUSIVE USE OF SEPARATE USER
GROUPS, THE TOILET FACILITIES SERVING EACH USER GROUP SHALL COMPLY WITH 11B-213 TOILET
CITY ENGINEER
CHOICES (IE, OFF-STREET PARKING, CARPORT OR GARAGE) THAT ARE AVAILABLE TO OTHER RESIDENTS
DATE:
PER 11B-208.2.3.3.
PASSENGER LOADING ZONES, DROP-OFF ZONES, AND BUS STOPS
74 15 WHERE TOILET ROOMS ARE PROVIDED, EACH TOILET ROOM SHALL COMPLY WITH 11B-603 TOILET AND
6 ONE IN EVERY SIX OR FRACTION OF SIX PARKING SPACES REQUIRED BY SECTION 11B-208.2 AT LEAST
27 PARKING FACILITIES THAT PROVIDE VALET PARKING SERVICES SHALL PROVIDE AT LEAST ONE BATHING ROOMS. WHERE BATHING ROOMS ARE PROVIDED, EACH BATHING ROOM SHALL COMPLY WITH
ONE SHALL BE A VAN PARKING SPACE. VAN PARKING SPACE SHALL BE 144 INCHES (12 FEET) WIDE
MINIMUM AND 216 INCHES (18 FEET) LONG MINIMUM AND SHALL BE SERVED BY AN ACCESS AISLE 60 PASSENGER LOADING ZONE COMPLYING WITH SECTION 11B-503. THE PARKING REQUIREMENTS OF
75 INTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND LOWER TREAD MARKED BY A STRIPE
PROVIDING CLEAR VISUAL CONTRAST. EXTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND ALL
TREADS MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST. THE STRIPE SHALL BE A MINIMUM 16 UNISEX (SINGLE-USER OR FAMILY) TOILET ROOMS SHALL CONTAIN NOT MORE THAN ONE LAVATORY, AND
SPACES MAY BE GROUPED ON ONE LEVEL OF A MULTI-STORY PARKING STRUCTURE. EXCEPTION: VAN
OF 2 INCHES WIDE TO A MAXIMUM OF 4 INCHES WIDE PLACED PARALLEL TO, AND NOT MORE THAN 1 INCH 28 MECHANICAL ACCESS PARKING GARAGES SHALL PROVIDE AT LEAST ONE PASSENGER LOADING ZONE NOT MORE THAN TWO WATER CLOSETS WITHOUT URINALS OR ONE WATER CLOSET AND ONE URINAL.
PARKING SPACES SHALL BE PERMITTED TO BE 108 INCHES (9 FEET) WIDE MINIMUM WHEN THE ACCESS
FROM, THE NOSE OF THE STEP OR UPPER APPROACH. THE STRIPE SHALL EXTEND THE FULL WIDTH OF UNISEX BATHING ROOMS SHALL CONTAIN ONE SHOWER OR ONE SHOWER AND ONE BATHTUB, ONE
THE STEP OR UPPER APPROACH AND SHALL BE OF MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS LAVATORY, AND ONE WATER CLOSET. DOORS TO UNISEX TOILET ROOMS AND UNISEX BATHING ROOMS
C THE OTHER TREADS OF THE STAIR. A PAINTED STRIPE SHALL BE ACCEPTABLE. GROOVES SHALL NOT BE
DESIGN GROUP
7 ACCESSIBLE PARKING SPACES COMPLYING WITH SECTION 11B-502 PARKING SPACES SERVING A 29 PASSENGER DROP-OFF AND LOADING ZONES SHALL PROVIDE A VEHICULAR PULL-UP SPACE 96 INCHES (8
PARTICULAR BUILDING OR FACILITY SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTE OF
TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE ENTRANCE (AS NEAR AS PRACTICAL TO AN 17 DOOR SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE.
76 OTHER THAN THE DOOR TO THE ACCESSIBLE WATER CLOSET COMPARTMENT, A DOOR IN ANY POSITION,
THAT PROJECT BEYOND RISERS SHALL HAVE THE UNDERSIDE OF THE LEADING EDGE CURVED OR
BEVELED. RISERS SHALL BE PERMITTED TO SLOPE UNDER THE TREAD AT AN ANGLE OF 30 DEGREES 30 PASSENGER DROP-OFF AND LOADING ZONES SHALL PROVIDE ACCESS AISLES COMPLYING WITH THE
FOLLOWING ADJACENT AND PARALLEL TO THE VEHICLE PULL-UP SPACE. ACCESS AISLES SHALL ADJOIN
8 IN BUILDINGS WITH MULTIPLE ACCESSIBLE ENTRANCES WITH ADJACENT PARKING, ACCESSIBLE PARKING
SPACES COMPLYING WITH SECTION 11B-502 PARKING SPACES SHALL BE DISPERSED AND LOCATED 18 AT SINGLE USER TOILET OR BATHING ROOMS, DOORS SHALL BE PERMITTED TO SWING INTO THE CLEAR
FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE ONLY IF A 30 INCH BY 48 INCH MINIMUM
CLEAR FLOOR SPACE IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOOR SWING.
a.
APPROVED BY:
DESIGNED BY:
EDGE OF THE REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
CHECKED BY:
MIRRORS NOT LOCATED ABOVE THE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE
DRAWN BY:
ENGINEER:
BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR
79 FLOOR IDENTIFICATION SIGNS REQUIRED BY CHAPTER 10 SHALL COMPLY WITH SECTIONS 11B-703.1 c. ACCESS AISLES SHALL BE MARKED WITH A PAINTED BORDERLINE AROUND THEIR PERIMETER. THE AREA
10 MINIMUM SPACE LENGTH SHALL BE 18 FOOT LONG FOR CAR AND VAN ACCESSIBLE PARKING SPACE(S) WITHIN THE BORDERLINES SHALL BE MARKED WITH HATCHED LINES A MAXIMUM OF 36 INCHES ON
SIGNS GENERAL, 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.5 VISUAL CHARACTERS.
THESE SIGNS SHALL BE LOCATED AT THE LANDING OF EACH FLOOR LEVEL, PLACED ADJACENT TO THE
DOOR ON THE LATCH SIDE, IN ALL ENCLOSED STAIRWAYS IN BUILDINGS TWO OR MORE STORIES IN 20 COAT HOOKS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN SECTION 11B-308.
HEIGHT TO IDENTIFY THE FLOOR LEVEL. AT THE EXIT DISCHARGE LEVEL, THE SIGN SHALL INCLUDE A SHELVES SHALL BE LOCATED 40 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR.
11 31 VEHICLE PULL-UP SPACES AND ACCESS AISLES SERVING THEM SHALL COMPLY WITH SECTION 11B-302 WORK ORDER NO.
RAISED FIVE POINTED STAR LOCATED TO THE LEFT OF THE IDENTIFYING FLOOR LEVEL. THE OUTSIDE MEDICINE CABINETS SHALL BE LOCATED WITH A USABLE SHELF NO HIGHER THAN 44 INCHES MAXIMUM
& FIG. 11B-502.3 AND 11B-502.3.3. FLOOR OR GROUND SURFACES. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE VEHICLE PULL-UP
E170121B
(DESIGN STAGE ONLY)
FOOT WIDE ACCESS AISLE. VAN PARKING SPACES SHALL BE PERMITTED TO BE MINIMUM 9 FEET WIDE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A021_24X36.DWG 12/3/2021 9:07 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
21 WHERE TOWEL OR SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, OR OTHER ACCESSORIES 43 AMBULATORY ACCESSIBLE COMPARTMENTS SHALL HAVE A DEPTH OF 60 INCHES MINIMUM AND A WIDTH F. COMMUNICATION ELEMENTS AND FEATURES 6 OVENS SHALL COMPLY WITH 11B-804-6.5. SIDE-HINGED DOOR OVENS SHALL HAVE THE WORK SURFACE ENGINEERING
ARE PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED ON AN REQUIRED BY SECTION 11B-804.3 POSITIONED ADJACENT TO THE LATCH ISDE OF THE OVEN DOOR AND
ACCESSIBLE ROUTE. ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40 INCHES MAXIMUM BOTTOM-HINGED DOOR OVENS SHALL HAVE THE WORK SURFACE REQUIRED BY SECTION 11B-804.3
ABOVE THE FINISH FLOOR. BABY CHANGING STATIONS ARE NOT REQUIRED TO COMPLY WITH SECTION FIRE ALARM SYSTEMS POSITIONED TO ONE SIDE OF THE DOOR. OVENS SHALL HAVE CONTROLS ON FRONT PANELS.
44
K
1 WHERE FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM SYSTEMS PROVIDE AUDIBLE ALARM
22 BATHTUBS SHALL COMPLY WITH SECTION 11B-607 INCLUDING THE REQUIREMENTS FOR CLEARANCES, MAIL BOXES
GRAB BARS, SEATS, CONTROLS, SHOWER SPRAY UNIT AND WATER AND BATHTUB ENCLOSURES. 45 WHERE URINALS ARE PROVIDED, AT LEAST 10 PERCENT BUT NO FEWER THAN ONE SHALL COMPLY WITH
2 ALARMS IN PUBLIC USE AREAS AND COMMON USE AREAS SHALL COMPLY WITH CHAPTER 9, SECTION 7 WHERE MAIL BOXES ARE PROVIDED IN AN INTERIOR LOCATION, AT LEAST 5 PERCENT, BUT NO FEWER
23 SHOWER COMPARTMENTS SHALL COMPLY WITH SECTION 11B-608 INCLUDING THE REQUIREMENTS FOR
CLEARANCES, GRAB BARS, SEATS, CONTROLS, SHOWER SPRAY UNIT AND WATER, THRESHOLDS, 46 URINALS SHALL BE THE STALL-TYPE OR THE WALL-HUNG TYPE WITH THE RIM 17 INCHES MAXIMUM
SHOWER ENCLOSURES, SHOWER FLOOR OR GROUND SURFACE AND SOAP DISH.
3 WHERE EMPLOYEE WORK AREAS HAVE AUDIBLE ALARM COVERAGE, THE WIRING SYSTEM SHALL BE WINDOWS
DESIGNED SO THAT VISIBLE ALARMS COMPLYING WITH CHAPTER 9, SECTION 907.5.2.3.1 EXCEPTION CAN
WATER CLOSETS AND TOILET COMPARTMENTS
47 FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS 8 WHERE GLAZED OPENINGS ARE PROVIDED IN ACCESSIBLE ROOMS OR SPACES FOR OPERATION BY
J SHALL COMPLY WITH SECTION 11B-309 OPERABLE PARTS EXCEPT THAT THE FLUSH CONTROL SHALL BE OCCUPANTS, AT LEAST ONE OPENING SHALL COMPLY WITH 11B-309 (OPERABLE PARTS WITHIN REACH
24 WHERE TOILET COMPARTMENTS ARE PROVIDED, AT LEAST 5 PERCENT OF THE TOILET COMPARTMENTS 4 RANGES). EACH GLAZED OPENING REQUIRED BY AN ADMINISTRATIVE AUTHORITY TO BE OPERABLE
FIRE ALARM SYSTEMS SHALL HAVE PERMANENTLY INSTALLED AUDIBLE AND VISIBLE ALARMS
(OR 5 PERCENT OF THE COMBINATION OF TOILET COMPARTMENTS AND URINALS), BUT NO FEWER THAN
ONE TOILET COMPARTMENT, SHALL COMPLY WITH SECTION 11B-604.8.1. IN ADDITION TO THE
COMPARTMENTS REQUIRED TO COMPLY WITH 11B-604.8.1, WHERE SIX OR MORE TOILET COMPARTMENTS 48 WHERE LAVATORIES ARE PROVIDED, AT LEAST 10 PERCENT BUT NO FEWER THAN ONE SHALL COMPLY
ARE PROVIDED, OR WHERE THE COMBINATION OF URINALS AND WATER CLOSETS TOTALS SIX OR MORE H. BUILT-IN ELEMENTS
FIXTURES, TOILET COMPARTMENTS COMPLYING WITH SECTION 11B-604.8.2 SHALL BE PROVIDED IN THE ASSISTIVE LISTENING SYSTEMS
10/31/2023
213.3.1
5 ASSISTIVE LISTENING SYSTEMS SHALL BE PROVIDED IN ASSEMBLY AREAS, INCLUDING CONFERENCE BENCHES
49 FOR LAVATORIES AND SINKS, A CLEAR FLOOR SPACE COMPLYING WITH SECTION 11B-305 CLEAR FLOOR
OR GROUND SURFACES, POSITIONED FOR A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE CLASSROOMS, LECTURE HALLS, COURTROOMS, PUBLIC MEETING ROOMS, PUBLIC HEARING ROOMS,
25 WHERE WATER CLOSETS ARE PROVIDED, AT LEAST 5 PERCENT BUT NO FEWER THAN ONE SHALL
LEGISLATIVE CHAMBERS, MOTION PICTURE HOUSES, AUDITORIA, THEATERS, PLAYHOUSES, DINNER 1 CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 11B-305 SHALL BE PROVIDED AND SHALL BE
EXCEPTION: A PARALLEL APPROACH COMPLYING WITH SECTION 11B-305 SHALL BE PERMITTED TO A THEATERS, CONCERT HALLS, CENTERS FOR THE PERFORMING ARTS, AMPHITHEATERS, ARENAS, POSITIONED AT THE END OF THE BENCH SEAT AND PARALLEL TO THE SHORT AXIS OF THE BENCH.
I KITCHEN SINK IN A SPACE WHERE A COOKTOP OR CONVENTIONAL RANGE IS NOT PROVIDED AND TO WET
BARS.
STADIUMS, GRANDSTANDS, OR CONVENTION CENTERS. THIS DOES NOT APPLY TO SYSTEMS USED
26 THE CLEAR WIDTH FOR ACCESSIBLE ROUTES TO ACCESSIBLE TOILET COMPARTMENTS SHALL BE 44
BUREAU OF ENGINEERING
50 LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR
27 THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. 6 PROVIDE A MINIMUM NUMBER OF RECEIVERS EQUAL TO 4 PERCENT OF THE TOTAL NUMBER OF SEATS,
THE CENTERLINE OF THE WATER CLOSET SHALL BE 17 INCHES MINIMUM TO 18 INCHES MAXIMUM FROM CONTROLS FOR FAUCETS SHALL COMPLY WITH SECTION 11B-309. HAND-OPERATED METERING FAUCETS
THE SIDE WALL OR PARTITION, EXCEPT THAT THE WATER CLOSET SHALL BE 17 INCHES MINIMUM AND 19
INCHES MAXIMUM FROM THE SIDE WALL OR PARTITION IN THE AMBULATORY ACCESSIBLE TOILET
COMPARTMENT SPECIFIED IN SECTION 11B-604.8.2 AMBULATORY ACCESSIBLE COMPARTMENTS. WATER 7 WHERE A BUILDING CONTAINS MORE THAN ONE ASSEMBLY AREA UNDER ONE MANAGEMENT, THE TOTAL
SIGNS RELATED TO TOILETS AND BATHING FACILITIES NUMBER OF REQUIRED RECEIVERS MAY BE CALCULATED USING THE TOTAL NUMBER OF SEATS IN THE
ACCESSIBILITY NOTES
FROM THE SIDE WALL AND 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR WALL. A IDENTIFIED BY A GEOMETRIC SYMBOL COMPLYING WITH 11B-703.7.2.6 TOILET AND BATHING ROOM
MINIMUM 60 INCHES WIDE AND 48 INCHES DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF GEOMETRIC SYMBOLS. 8 TWENTY-FIVE PERCENT MINIMUM OF RECEIVERS PROVIDED FOR ASSISTIVE LISTENING SYSTEMS, BUT NO
FEWER THAN TWO, SHALL BE HEARING-AID COMPATIBLE IN ACCORDANCE WITH SECTION 11B-706.3.
52 WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH 11B-603 TOILET AND
29 THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH FLOOR SHALL BE 17 INCHES MINIMUM AND 19 BATHING ROOMS, DIRECTIONAL SIGNS INDICATING THE LOCATION OF THE NEAREST COMPLIANT TOILET
INCHES MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS SHALL NOT BE SPRUNG TO RETURN TO A ROOM OR BATHING ROOM WITHIN THE FACILITY SHALL BE PROVIDED. 9 WHERE ALL SEATS IN AN ASSEMBLY AREA ARE SERVED BY MEANS OF AN INDUCTION LOOP ASSISTIVE
LIFTED POSITION. SEATS SHALL BE 2 INCHES HIGH MAXIMUM AND A 3 INCH HIGH SEAT SHALL BE LISTENING SYSTEM, THE MINIMUM NUMBER OF RECEIVERS REQUIRED BY SECTION 11B-219.3 TO BE
PERMITTED ONLY IN ALTERATIONS WHERE THE EXISTING FIXTURE IS LESS THAN 15 INCHES HIGH.
53 SIGNS SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS AND SHALL INCLUDE THE INTERNATIONAL
HORIZONTAL CONTROL:
SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA.
VERTICAL CONTROL:
10 WHEN ASSISTIVE-LISTENING SYSTEMS ARE LIMITED TO SPECIFIC AREAS OR SEATS, SUCH AREAS OR
30 THE SIDE WALL GRAB BARS SHALL BE 42 INCHES LONG MINIMUM, LOCATED 12 INCHES MAXIMUM FROM SEATS SHALL BE WITHIN A 50-FOOT VIEWING DISTANCE OF THE STAGE OR PLAYING AREA AND SHALL
G THE REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR WALL WITH THE FRONT END 54 WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH 11B-603, THE TOILET
SHEET TITLE:
ROOMS OR BATHING ROOMS COMPLYING WITH 11B-603 TOILET AND BATHING ROOMS SHALL BE
ADDRESS:
PROJECT:
IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA.
11 PERMANENTLY INSTALLED ASSISTIVE-LISTENING SYSTEMS ARE REQUIRED IN AREAS IF (1) THEY
31 THE REAR GRAB BAR SHALL BE 36 INCHES LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF THE ACCOMMODATE AT LEAST 50 PERSONS OR IF THEY HAVE AUDIO-AMPLIFICATION SYSTEMS, AND (2) THEY
WATER CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES MINIMUM ON THE OTHER SIDE. 55 WHERE CLUSTERED SINGLE USER TOILET ROOMS OR BATHING FACILITIES ARE PERMITTED TO USE HAVE FIXED SEATING. IF PORTABLE ASSISTIVE-LISTENING SYSTEMS ARE USED FOR CONFERENCE OR
EXCEPTIONS TO 11B-213.2, TOILET ROOMS OR BATHING FACILITIES COMPLYING WITH 11B-603 TOILET AND MEETING ROOMS, THE SYSTEM MAY SERVE MORE THAN ONE ROOM. AN ADEQUATE NUMBER OF
BATHING ROOMS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING ELECTRICAL OUTLETS OR OTHER SUPPLEMENTAL WIRING NECESSARY TO SUPPORT A PORTABLE
BY:
TOILET AND BATHING ROOMS.
32 FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS
SHALL COMPLY WITH SECTION 11B-309 EXCEPT THEY SHALL BE LOCATED 44 INCHES MAXIMUM ABOVE
DATE:
CIP NO.
THE FLOOR. FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET EXCEPT 12 PORTABLE ASSISTIVE-LISTENING SYSTEMS MAY SERVE MORE THAN ONE CONFERENCE OR MEETING
56 EXISTING BUILDINGS THAT HAVE BEEN REMODELED TO PROVIDE SPECIFIC TOILET ROOMS OR BATHING ROOMS IF AN ADEQUATE NUMBER OF ELECTRICAL OUTLETS OR OTHER SUPPLEMENTARY WIRING IS
ROOMS FOR PUBLIC USE THAT COMPLY WITH THESE BUILDING STANDARDS SHALL HAVE THE LOCATION
F OF AND THE DIRECTIONS TO THESE ROOMS POSTED IN OR NEAR THE BUILDING LOBBY OR ENTRANCE ON
A SIGN COMPLYING WITH 11B-703.5 VISUAL CHARACTERS, INCLUDING THE INTERNATIONAL SYMBOL OF
33 TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION 11B-309.4 OPERATION AND SHALL BE 7
INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE 13 RECEIVERS REQUIRED FOR USE WITH AN ASSISTIVE LISTENING SYSTEM SHALL INCLUDE A 1/8 INCH
CENTERLINE OF THE DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE BELOW THE GRAB BAR, 19
INCHES MINIMUM ABOVE THE FINISH FLOOR AND SHALL NOT BE LOCATED BEHIND THE GRAB BARS.
57 PICTOGRAMS SHALL COMPLY WITH THE FOLLOWING:
DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY OR THAT DOES NOT ALLOW
14 RECEIVERS REQUIRED TO BE HEARING-AID COMPATIBLE SHALL INTERFACE WITH TELECOILS IN HEARING
a. PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6 INCHES MINIMUM. CHARACTERS AND BRAILLE SHALL
34 SANITARY NAPKIN DISPOSAL UNITS, IF PROVIDED, SHALL COMPLY WITH SECTION 11B-309.4 AND SHALL BE
WALL MOUNTED AND LOCATED ON THE SIDEWALL BETWEEN THE REAR WALL OF THE TOILET AND TOILET 15 ASSISTIVE LISTENING SYSTEMS SHALL BE CAPABLE OF PROVIDING A SOUND PRESSURE LEVEL FROM 110
PAPER DISPENSER, ADJACENT TO THE TOILET PAPER DISPENSER. THE DISPOSAL UNIT SHALL BE
LOCATED BELOW THE GRAB BAR WITH THE OPENING OF THE DISPOSAL UNIT 19 INCHES MINIMUM (483 b. PICTOGRAMS AND THEIR FIELD SHALL HAVE A NON-GLARE FINISH. PICTOGRAMS SHALL CONTRAST WITH
E THEIR FIELD WITH EITHER A LIGHT PICTOGRAM ON A DARK FIELD OR A DARK PICTOGRAM ON A LIGHT
16 SIGNAL-TO-NOISE RATIO FOR INTERNALLY GENERATED NOISE IN ASSISTIVE LISTENING SYSTEMS SHALL
REVISIONS:
AND 59 INCHES DEEP MINIMUM FOR FLOOR MOUNTED WATER CLOSETS MEASURED PERPENDICULAR TO DESCRIPTORS SHALL COMPLY WITH 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.4
17
WIDE MINIMUM MEASURED PERPENDICULAR TO THE SIDE WALL, AND 59 INCHES DEEP MINIMUM FOR
INDEX NO.
WALL HUNG AND FLOOR MOUNTED WATER CLOSETS MEASURED PERPENDICULAR TO THE REAR WALL.
TWO WAY COMMUNICATION SYSTEMS
d.
NO.
CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND
SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60 INCHES MAXIMUM
ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST LINE 18 TWO-WAY COMMUNICATION SYSTEMS THAT ARE PROVIDED TO GAIN ADMITTANCE TO A BUILDING OR
36 IN A WHEELCHAIR ACCESSIBLE COMPARTMENT WITH AN IN-SWING DOOR, A MINIMUM 60 INCHES WIDE BY
D 36 INCHES DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE CLEARANCE REQUIRED IN OF RAISED CHARACTERS. FACILITY OR TO RESTRICTED AREAS WITHIN A BUILDING OR FACILITY SHALL PROVIDE BOTH AUDIBLE
CITY ENGINEER
DATE:
11B-604.8.1.1.2(B) AND 11B-604.8.1.1.3(B)
58 SYMBOLS SHALL COMPLY WITH THE FOLLOWING:
19 OMIT.
37 IN A WHEELCHAIR ACCESSIBLE COMPARTMENT WITH A DOOR LOCATED IN THE SIDE WALL OR PARTITION,
EITHER IN-SWINGING OR OUT-SWINGING, A MINIMUM 60 INCHES WIDE AND 60 INCHES DEEP a. DOORWAYS LEADING TO TOILET ROOMS AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC
SYMBOL COMPLYING WITH 11B-703.7.2.6. THE SYMBOL SHALL BE MOUNTED AT 58 INCHES MINIMUM AND
11B- 604.8.1.1.2 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED FROM THE 20 OMIT.
CENTERLINE OF THE SYMBOL. WHERE A DOOR IS PROVIDED THE SYMBOL SHALL BE MOUNTED WITHIN 1
38 IN A WHEEL CHAIR ACCESSIBLE COMPARTMENT WITH END OPENING DOOR LOCATED IN THE FRONT WALL G. SPECIAL ROOMS, SPACES, AND ELEMENTS
OR PARTITION (FACING WATER CLOSET), EITHER IN-SWINGING OR OUT-SWINGING, A MINIMUM 60 INCHES
WIDE AND 48 INCHES DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE WATER b.
C THICK WITH EDGES 12 INCHES LONG AND A VERTEX POINTING UPWARD. THE TRIANGLE SYMBOL SHALL NEW KITCHENS, KITCHENETTES, AND WET BARS
DESIGN GROUP
CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT
39 TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECTION 11B-404 1 NEW LAVATORIES AND SINKS SHALL COMPLY WITH 11B-606, INCLUDING CLEAR FLOOR SPACE, HEIGHT,
EXCEPT THAT IF THE APPROACH IS FROM THE PUSH SIDE OF THE COMPARTMENT DOOR, CLEARANCE
BETWEEN THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION SHALL BE 48 INCHES c.
MINIMUM MEASURED PERPENDICULAR TO THE COMPARTMENT DOOR IN ITS CLOSED POSITION. DOORS INCHES IN DIAMETER. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK
SHALL BE LOCATED IN FRONT PARTITION OR IN THE SIDE WALL OR PARTITION FARTHEST FROM THE
2 AT LEAST 50 PERCENT OF SHELF SPACE IN STORAGE FACILITIES SHALL COMPLY WITH 11B-811, SHALL
HAVE A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B-305 AND SHALL BE WITHIN AT
d.
APPROVED BY:
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
41 A DOOR PULL COMPLYING WITH SECTION 11B-404.2.7 DOOR AND GATE HARDWARE SHALL BE PLACED ON
BOTH SIDES OF THE DOOR NEAR THE LATCH. DOOR SHALL NOT SWING INTO THE CLEAR FLOOR SPACE WASHING MACHINE AND CLOTHES DRYERS
OR CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS MAY SWING INTO THAT PORTION OF THE 4 WHERE A DISHWASHER IS PROVIDED, THE CLEAR OR GROUND SPACE SHALL BE POSITIONED ADJACENT
MANEUVERING SPACE WHICH DOES NOT OVERLAP THE CLEARANCE REQUIRED AT A WATER CLOSET. TO THE DISHWASHER DOOR. THE DISHWASHER DOOR, IN THE OPEN POSITION, SHALL NOT OBSTRUCT
59
WORK ORDER NO.
5 WHERE A RANGE OR COOKTOP IS PROVIDED, AND A FORWARD APPROACH IS PROVIDED, THE CLEAR
42 AT LEAST ONE SIDE PARTITION SHALL PROVIDE A TOE CLEARANCE OF 9 INCHES MINIMUM ABOVE THE
FLOOR OR GROUND SPACE SHALL PROVIDE KNEE AND TOE CLEARNACE COMPLYING WITH SECTION E170121B
FINISH FLOOR AND 6 INCHES DEEP MINIMUM BEYOND THE COMPARTMENT-SIDE FACE OF THE PARTITION,
(DESIGN STAGE ONLY)
60 TOP LOADING MACHINES SHALL HAVE THE DOOR TO THE LAUNDRY COMPARTMENT LOCATED 36 INCHES 11B-306. WHERE KNEE AND TOE SPACE IS PROVIDED, THE UNDERSIDE OF THE RANGE OR COOKTOP
EXCLUSIVE OF PARTITION SUPPORT MEMBERS. PARTITION COMPONENTS AT TOE CLEARANCES SHALL BE
A MAXIMUM ABOVE THE FINISH FLOOR. FRONT LOADING MACHINES SHALL HAVE THE BOTTOM OF THE SHALL BE INSUATEDS OR OTHERWISE CONFIGURED TO PREVENT BURNS, ABRASIONS, OR ELECTRICAL
SHEET NAME
REVISION DATES
OPENING TO THE LAUNDRY COMPARTMENT LOCATED 15 INCHES MINIM AND 36 INCHES MAXIMUM ABOVE SHOCK. THE LOCATIONS OF CONTROLS SHALL NOT REQUIRE REACHING ACROSS BURNERS.
A0.22
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A022_24X36.DWG 12/3/2021 9:07 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
PULL SIDE ENGINEERING
24"
MIN.
CLEAR AT EXTERIOR DOORS
K
60" MIN.
18"
MIN.
1/2" MAX.
CLEAR AT INTERIOR DOORS
MAX.
24"
MAX.
1/4"
2
32" MIN. 1
18" MIN.
48" MIN.
PROVIDE THIS ADDITIONAL (A) HINGED DOOR
SPACE IF DOOR IS EQUIPPED
WITH BOTH LATCH AND A
CLOSER CENTERLINE TO CENTER OF
J 9" 9" TACTILE CHARACTERS. COMPRESSED CARPET 1/4" MAX.
BELOW TRESHOLD
PUSH SIDE 4" SQUARE ROOM NUMBER
(EXTERIOR). 32" MIN. 32" MIN.
12"
101
MIN. FINISH FLOOR EVEN
(B) SLIDING DOOR (C) FOLDING DOOR 10/31/2023
(A) FRONT APPROACH
NOTE: HEIGHT SHALL BE THRESHOLD
TO BOTTOM OF TACTILE NOTE:
CHARACTERS 60" MAX. OR
BOTTOM OF BRAILLE, 48" MIN. PROVIDE BUMPER IN POCKET TO
PREVENT DOOR FROM FULLY RECEDING
5'-0"
I PER 2013 CBC 11B-703.4.1
PULL SIDE
60" MIN.
HORIZONTAL CONTROL:
5. PROVIDE THE FOLLOWING SIGNS:
VERTICAL CONTROL:
a). 'SMOKING IS PROHIBITED WITHIN 25' OF ENTRIES, AIR INTAKES AND WINDOWS.'
G b). 'SMOKING IS PROHIBITED IN ALL COMMON AREAS.'
6. PROVIDE EXIT SIGNS AS REQUIRED BY CODE. VISION
SHEET TITLE:
10" MIN. TALL SMOOTH, LITE
ADDRESS:
PROJECT:
UNINTERRUPTED SURFACE TO
PULL SIDE
ALLOW DOOR TO BE OPENED BY
FOOTREST WITHOUT CREATING A
60" MIN.
DATE:
CIP NO.
* 44" MIN.
PUSH SIDE
24"
MIN. * NOTE:
48" MINIMUM IF DOOR HAS A
CLOSER
11 08 05 02
TYP. LEVEL MANUEVERING CLEARANCE @ DOORS DOOR SIGNAGE GENERAL NOTES TYP. CHANGE IN LEVEL DOOR CONSTRUCTION
REVISIONS:
REF: -- SCALE: 3" = 1'-0" REF: -- SCALE: 3" = 1'-0" REF: DOOR & FINISH DETAILS SCALE: 3" = 1'-0" REF: -- SCALE: 3" = 1'-0"
INDEX NO.
NO.
MIRROR (NOT ABOVE SINK OR
CITY ENGINEER
DATE:
WASTE RECEPTACLE
RECESSED TOILET
RECESSED TOILET
FLOOR MOUNTED
FLOOR MOUNTED
FOUNTAIN WITH ONE
PAPER HOLDER
PAPER HOLDER
WALL MOUNTED
WALL MOUNTED
(ABOVE SINK OR
COUNTER)
WALL FINISH
WALL FINISH
DRINKING FOUNTAIN
PORTION OF ALL
DISPENSERS/ ACTIVATE THE CONTROLS
SOAP DISPENSER
HAND DRYER
ELECTRICAL
COAT HOOK
54" MIN.
SHELVES
C 6"MAX. 6"MAX.
SWITCH
URNIAL
36" MIN. 36" MIN. MIN. FOR ALL GRAB
DESIGN GROUP
MAX. 42" MIN.
1'-0" 1'-0" BARS, TYP.
24" MIN. CL MIN. 24" MIN. CL MIN. 24"
MIN.
2'-8"
HIGHEST OPERABLE PART
1'-4"
TOP OF COAT HOOK
40" MAX.TO
36"MAX. ACCESS.
44" MAX.
40" MAX.
35" MAX.
33"-36"
33"-36"
27" MIN.
CL
B
9" MIN.
17" MAX.
19" MIN.
OUTLET
7"-9"
TO CL
APPROVED BY:
18"
OF
DESIGNED BY:
CL
CHECKED BY:
DRAWN BY:
ENGINEER:
FINISH FLOOR
TOILET PAPER
ALL EXPOSED HOT WATER URINAL TO 12"MIN. 17" MIN. 12"MIN. 17" MIN. HOLDER W/O STOPS. IF
PIPES UNDER ALL SINKS PROTRUDE 14" 18" MAX. 18"MAX.
CL CL ONE PAPER HOLDER
SHALL BE INSULATED. MAX. FROM WALL
USED, POSITION HERE.
WORK ORDER NO.
E170121B
(DESIGN STAGE ONLY)
A 01 SHEET NAME
REVISION DATES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A023_24X36.DWG 12/3/2021 9:07 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
8"
ENGINEERING
1" HIGH RAISED
FAUCET TO BE LEVER TYPE.
UNISEX RESTROOM SIGNAGE LETTERING 1/2"
DESIGNATING ROOM
1/2"
NUMBER (UNLESS
K MAX. BOWL DEPTH = 6 1/2" TYP
PANEL: WHITE ACRYLIC
TABLE 11B-703.5.5
SHEET (NON-GLARE), COLOR
1"
PROVIDE CABINET DOORS W/ PICTOGRAPHS AND TEXT AND
INTEGRAL TOE KICK. NO CABINET WALL, ANCHORED TO WALL
1/2"
OR SHELVING. AT FOUR LOCATIONS, TYP.
5/8"
FINISHED FLOOR TO EXTEND COMMUNITY
BENEATH THE COUNTERTOP.
MALE/FEMALE PICTOGRAPH ROOM
AND ISA USE SAME SYMBOL 5/8" HIGH RAISED
ON ADJACENT DOOR MTD.
3/8"
LETTERING
SIGN DESIGNATING ROOM
OF TACTILE, TYP.
J
OF BRAILLE, TYP.
(SANS SERIF FONT) W/ GRADE 4'-0" MIN. BASELINE OF 5'-0" MAX. BASELINE OF
WORKSPACE: 2 BRAILLE BELOW WALL GRADE 2 BRAILLE TO BE LOWEST BRAILLE HIGHEST TACTILE CHARACTER
COUNTER TOP TO BE 3/8" MIN.-1/2" MAX. CHARACTER TO TO FINISHED FLOOR
MAXIMUM OF 34" BELOW TEXT AND 3/8" FINISHED FLOOR
A.F.F., TYPICAL. MIN. TO BOTTOM OF 10/31/2023
48" MIN.
PROVIDE REMOVABLE SIGN.
CABINETS, FLOORING
TO EXTEND.
NOTES:
DOOR
I 1. ALL TEXT TO BE SANS SERIF FONT RAISED 1/32" MIN., WITH GRADE 2 BRAILLE
2. ALL SIGNAGE SHALL CONFORM TO CCR, TITLE 24, CALIFORNIA BUILDING CODE SECTION 11B-703.
PANEL: TRIANGLE 3. SIGN SHALL BE NON- GLARE, ACRYLIC, OR OTHER SOLID MATERIAL OF CONSISTENT COLOR.
SUPERIMPOSED OVER A 4. SIGNS THAT PROVIDE DIRECTION TO OR INFORMATION ABOUT INTERIOR AND EXTERIOR SPACES AND
BUREAU OF ENGINEERING
CIRCLE, 1/4" THK. ACRYLIC FACILITIES OF THE SITE SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS.
COUNTERTOP COUNTERTOP SHEET (NON-GLARE), 5. SIGNS FOR MEANS OF EGRESS SHALL COMPLY WITH 11B-216.4 MEANS OF EGRESS.
SINK SPACE WORK SPACE GEOMETRIC SHAPES SHALL 6. ACCESSIBLE SIGN TO CONFORM WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE CBC-CHAPTER
CONTRAST WITH EACH 11B-703. (703.1 TO 703.7.2.6.3)
1'-0"
OTHER & DOOR.
2014 CBC. SEC 11B-703
12 09 03
TYP. WHEEL CHAIR MANUVERING CLEARANCE TYPICAL ACCESSIBLE SINK TYP. ROOM IDENTIFICATION SIGNAGE
17" MIN.
18" MIN.
AT BASE OR ONE ARM 6"
ONLY. CLEAR 1" HIGH RAISED
30" MIN.
WALL SIGNAGE LETTERING 1/2"
HORIZONTAL CONTROL:
FLOOR
CL
DESIGNATING ROOM
VERTICAL CONTROL:
SPACE
NUMBER (UNLESS
G TABLE 11B-703.5.5
6" MIN.
N.T.S.
SHEET TITLE:
REQUIRES A GREATER
17" MIN.
201
ADDRESS:
1/2"
HEIGHT.)
PROJECT:
19" MAX.
3"
48" MIN.
MEN WOMEN UNISEX
OF TACTILE, TYP.
TOE CLEARANCE SHALL GRADE 2 BRAILLE TO BE
BY:
LAVATORY & 25" MAX AT LEVER-OPERATED FAUCET BELOW TEXT AND 3/8"
ELEMENTS. MIN. TO BOTTOM OF
T-SHAPED CONTROL, TYP. 4'-0" MIN. BASELINE 5'-0" MAX. BASELINE OF
DATE:
CIP NO.
LETTERS AND NUMERALS SHALL BE RAISED 1/32", UPPER CASE, SANS SERIF SIGN. OF LOWEST BRAILLE HIGHEST TACTILE
6 1/2" MAX. BOWL DEPTH, TYP. TYPE AND SHALL BE ACCOMPANIED WITH GRADE II BRAILLE. RAISED
CHARACTER TO CHARACTER TO FINISHED
F CHARACTERS SHALL BE AT LEAST 5/8" HIGH, BUT NO HIGHER THAN 2"
FINISHED FLOOR FLOOR
CHARACTERS SHALL CONTRAST W/ THEIR BACKGROUND AND BE OF A
NOTE: NON-GLARE (MATTE) FINISH. CORRESPONDING GRADE II BRAILLE. DOTS SHALL
CAN INCLUDE KNEE & BE 1/10" O.C. IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS. DOTS SHALL BE
TOE SPACE COMPLYING RAISED A MINIMUM OF 1/40" ABOVE THE BACKGROUND.
34" MAX.
29" MIN.
.
60" MIN
27" MIN.
11B-306.
INSULATION @ HOT WATER
9" MIN.
12
11B-304.4, 12" MAX., WITH THE EXCEPTION OF THE ACCESSIBLE 5. SIGNS FOR MEANS OF EGRESS SHALL COMPLY WITH 11B-216.4 MEANS OF EGRESS.
"
12"
12"
WATER CLOSET COMPARTMENT PER 11B-603.2.3. 6. ACCESSIBLE SIGN TO CONFORM WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE
SECTION AT LAV (PER 11B-306 & 11B-606) CBC-CHAPTER 11B-703. (703.1 TO 703.7.2.6.3)
11 08 02
REVISIONS:
TURNING SPACE TYP. LAVATORY CLEARANCES (WOMENS) (MENS) (UNISEX) TYP. ROOM IDENTIFICATION SIGNAGE
INDEX NO.
REF: -- SCALE: 3" = 1'-0" REF: -- SCALE: 3" = 1'-0" REF: -- SCALE: 3" = 1'-0"
NO.
D 3- #14 SCREWS (MIN.) 1 1/4" TO 2" MAX. OUTSIDE NOTE:
CITY ENGINEER
ALSO SEE SECTION FOR DIAMETER PICTOGRAMS AND/OR LETTERING ARE NOT
DATE:
6"
3/8" ATTACHMENT DETAILS REQUIRED ON DOOR- MOUNTED SIGNAGE. SIGNAGE
1 1/2" SHALL BE 1/4" THK. & CONTRAST W/ COLOR OF THE
ABSOLUTE DOOR. ALL SIGNAGE MUST HAVE NON-GLARE FINISH 1" HIGH RAISED
B
& CONTRAST W/ COLOR OF WALL. LETTERING CENTERED IN
PANEL (UNLESS TABLE
11B-703.5.5 REQUIRES A
SHALL BE WITHIN GREATER HEIGHT.)
1" TO CENTERLINE
3"
OF DOOR.
2"
MAX.
1/2"
A 40" MIN
26" MIN
C
DESIGN GROUP
DOOR-MOUNTED SIGNAGE
FINISHED WALL - SEE GRADE 2 BRAILLE TO BE
38" MIN
38" MIN
31" MAX
31" MAX
PLANS FOR WALL WALL MOUNTED SIGNAGE TO BE 3/8" MIN. - 1/2" MAX. 4'-0" MIN. BASELINE OF 5'-0" MAX. BASELINE OF
CONSTRUCTION LOCATED ON LATCH SIDE OF BELOW TEXT AND 3/8" LOWEST BRAILLE HIGHEST TACTILE CHARACTER
MEN
3" DOOR CLEAR OF DOOR-SWING. MIN. TO BOTTOM OF SIGN. CHARACTER TO FINISHED TO FINISHED FLOOR
BACKING PLATE, SEE MOUNT PER 08/A0.23. FLOOR
08/A5.01
EQ. EQ.
4'-0" AFF
B A B
APPROVED BY:
18" MIN.
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
MIN. CLEARANCE FOR SIGNAGE NOTES:
NOTES: AT DOOR SWING, CENTERED ON 1. LOCATE AT ALL GRADE LEVEL EXTERIOR EXIT DOORS.
1. MAX SPACING BETWEEN ANCHOR/GRAB BAR SUPPORTS = 48" TACTILE CHARACTERS. 2. ALL TEXT TO BE SANS SERIF FONT RAISED 1/32" MIN., WITH GRADE 2 BRAILLE.
2. ALL GRAB BARS AND ACCESSORIES TO BE 18 GAUGE - 304 STAINLESS STEEL. 3. SIGN SHALL BE NON-GLARE, ACRYLIC, OR OTHER SOLID MATERIAL OF CONSISTENT
3. USE 11 GAUGE WELDED 304 STAINLESS STEEL MOUNTING FLANGES COLOR.
4. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS AND SHALL ALLOW FOR A VERTICAL AND NOTE: ACCESSIBLE SANITARY FACILITIES ARE 4. SIGNS THAT PROVIDE DIRECTION TO OR INFORMATION ABOUT INTERIOR AND WORK ORDER NO.
HORIZONTAL BENDING STRESS, SHEAR & TENSILE FORCE OF 250 LBS. MIN. REQUIRED TO HAVE BOTH DOOR MOUNTED & WALL EXTERIOR SPACES AND FACILITIES OF THE SITE SHALL COMPLY WITH 11B-703.5 VISUAL
NOTE: PROVIDE GRAB BAR BACKING @ ALL GRAB BARS
MOUNTED SIGNAGE. CHARACTERS. E170121B
(DESIGN STAGE ONLY)
5. SIGNS FOR MEANS OF EGRESS SHALL COMPLY WITH 11B-216.4 MEANS OF EGRESS.
A 6. ACCESSIBLE SIGN TO CONFORM WITH THE REQUIREMENTS OF THE LATEST EDITION OF
SHEET NAME
REVISION DATES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A024_24X36.DWG 12/3/2021 9:08 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
K
12" 12"
MAX MAX
POST OR POST
PYLON OR
PYLON
CANE HITS POST
THIS OVERHANG CAN OR PYLON
BE GREATER THAN 12" BEFORE PERSON
BECAUSE NO ONE
J CAN APPROACH THE
HITS OBJECT
WHEN >
OBJECT FROM THIS
27"
DIRECTION. CANE
RANGE
FIGURE 11B-704.2.1.2, 11B-704.2.1.2 PER P/BC 2017-089 - OBJECTS MOUNTED ON POSTS OR PYLONS NOTE:
1. DOOR CLOSERS SHALL NOT ENCROACH BELOW 80".
2. PROVIDE 'CANE DETECTION BARRIER' AT ALL
I OBSTRUCTIONS THAT DO NOT MEET THE CLEARANCES IN
THIS DETAIL.
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G
SHEET TITLE:
ADDRESS:
PROJECT:
UNOBSTRUCTED HIGH SIDE REACH
(PER 11B-308.3.1)
CIP NO.
F
02
REVISIONS:
TYP. SIDE REACH
INDEX NO.
REF: SCALE: 3" = 1'-0"
NO.
D
CITY ENGINEER
DATE:
NOTE: IF FORWARD
C REACH IS OVER A
COUNTER OR
DESIGN GROUP
OBSTRUCTION THAT IS
FIGURE 11B-404.2.4.3 CLEARANCES AT RECESSED DOORS AND GATES > 20"-25" MAX., THE
MAXIMUM REACH
SHALL BE 44".
APPROVED BY:
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
WORK ORDER NO.
E170121B
(DESIGN STAGE ONLY)
FIGURE 11B-404.2.6 CLEARANCES AT DOORS AND GATES IN A SERIES FIGURE 11B-404.2.4.1 CLEARANCES AT MANUAL SWINGING DOORS AND GATES
A SHEET NAME
REVISION DATES
04 01
CLEARANCES AT DOORS & GATES TYP. FOWARD REACH A0.25
X X
SHEET OF SHEETS
REF: -- SCALE: N.T.S REF: -- SCALE: 3" = 1'-0"
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A025_24X36.DWG 12/3/2021 9:08 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ACCESSIBLE PATH, WHERE 1'-3" MIN ENGINEERING
OCCURS. REFLECTORIZED FOR ROUGHER THAN SURROUNDING
PARKING & NON-GLARE PROVIDE A TRANSVERSE
EV CHARGER, SEE PARKING FOR OTHER SIGNS, BROOMED SURFACE TEXTURE
VAN DETECTABLE WARNINGS
ACCESSIBLE PLAN. PORCELAIN ON STEEL, ARE TO BE YELLOW WITH .
K EVCS BLUE BACKGROUND THE DOMES IN-LINE. AX
CLEAR FLOOR SPACE @ PARKING M
10
P.
ONLY WHITE SYMBOL, TYP.
1:
TY
CHARGERS.
LANDING MUST
VAN
BE AS WIDE
ACCESSIBLE
STANDARD EVCS STALL
AS RAMP
4'-0" MIN.
PER 11B-502.6
MARKINGS MUST CONTRAST WHERE OCCURS 1:12 MAX. LEVEL
VEHICLE SURFACE, BLUE TYP. LANDING
INDICATE MIN A CURB RAMP SHALL HAVE A
COLOR USED FOR
FINE IS $250.00 DETECTABLE WARNING THAT
IDENTIFICATION OF ACCESS 1'-3" 1'-3"
PER 11B-502.6.2. EXTENDS 36" FROM THE BACK
AISLES IN ACCESSIBLE
FACE OF THE CURB AND FOR 4'-0" MIN.
PARKING SHALL NOT BE
2" DIA. X 1/4" STL THE FULL WIDTH MINUS 2" MAX 36" LANDING
USED.
POST, LOCATE FROM EACH EDGE
SURFACE OF PARKING IN DIRECTION
SIGN AT CENTER
J SPACE AND ACCESS AISLE
OF STALL OF TRAVEL
NO DOES NOT EXCEED 2% NEW 6"H CURB, SEE SITE PLAN
EV CHARGING EV CHARGING
PARKING GRADIENT IN ANY DIRECTION
ONLY ONLY NEW CONCRETE SIDEWALK
12" MIN TALL LETTERING
PAINTED ON THE GROUND IN
WHITE 10/31/2023
5'-0" MIN DIRECTIONAL SIGN TO
EQ EQ EQ EQ CENTERLINE OF TEXT
ACCESS MAIN ENTRANCE ALL CURB RAMPS TO FOLLOW SEC. 11B-406
12'-0" CLR AISLE 9'-0" CLR SHALL BE A MAXIMUM OF 6"
FROM THE CENTERLINE OF T.O. CONC.
NOTES:
THE VEHICLE SPACE AND
1. SLOPE OF RAMP SHALL NOT EXCEED 1 VERTICAL IN 12 HORIZONTAL.
ITS LOWER CORNER AT, OR
2. PROVIDE A LEVEL LANDING 4'-0" DEEP BY ITS FULL WIDTH.
LOWER SIDE ALIGNED WITH,
I THE END OF THE PARKING
3. FLARED SIDES OF RAMP SHALL NOT EXCEED 10%.
SPACE LENGTH.
ACCESSIBLE PATH, A POLE MOUNTED B WALL MOUNTED
09 06 03
EVCS PARKING TYPICAL PARKING SIGNAGE CURB RAMP DETAIL
ACCESSIBILITY DETAILS
H
PAINT WHITE
BACKGROUND W/ BLACK
(OR BLUE BACKGROUND
WITH WHITE) LETTERS,
CEILING MTD LOCATION 1'-10" NUMBER, ADDRESS, AND
14/- BORDER STRIPE.
1/2" RADIUS, TYP. ALL LETTERING SHALL BE 3'-0" MIN.
UNAUTHOURIZED VEHICLES
12" MIN. REFLECTORIZED PARKED IN DESIGNATED
A PERMANENT PART OF
HORIZONTAL CONTROL:
ACCESSIBLE SPACES NOT
VERTICAL CONTROL:
PLACARDS OR SPECIAL
SHEET TITLE:
RECLAIMED AT:
MITER CORNER * 1823 HOPE STREET STANDARD 595C)
ADDRESS:
PROJECT:
1/2" W. WHITE BORDER OF FRAME ANGLE, OR BY TELEPHONING:
* LOS ANGELES CA 90015
A. 60" MIN. FOR GRIND SMOOTH & TELEPHONE NO: WHITE FIGURE
REFLECTORIZED WALL MOUNTED ALL WELDS (213)
14/- * BLANK SPACES ARE TO BE FILLED IN
SIGN CONSTRUCTED WITH APPROPIATE INFORMATION AS
AS A PERMANENT PART
B. 80" MIN. FOR A PERMANENT PART OF THE SIGN.
INTERNATIONAL
OF PORCELAIN STEEL OF THE SIGN.
1-1/2" POST 2" DIA. X 1/4" SYMBOL OF
BY:
OR EQUAL STEEL POST SIGN TO BE LOCATED AT ACCESSIBILITY PER
MINIMUM FINE EACH VEHICLE ENTRY 2016 CBC 11B-703.7.2.1
$250.00 C. 7'-0" MIN. FOR
DATE:
VISIBLE TO A CAR
CIP NO.
CEILING POST ENTERING OR VISIBLE
MOUNTED
F FROM EACH ACCESSIBLE
PARKING SPACE.
TO TOP OF T.O. CONC.
1/8" MIN RADIUS, TYP VAN WALKING SURFACE T.O. CONC.
ACCESSIBLE
WHERE OCCURS
FROM BOTTOM OF
ISA MUST BE ALIGNED WITH THE END OF THE PARKING SPACE AND
SIGN(S) TO
NOTES: FINISHED GRADE
FRONT ELEVATION
1. SIGN TO BE CENTERED AT
THE INTERIOR END OF 2" DIA. X 1/4" STL
PARKING SPACE. POST @ FLOOR NOTE:
MTD LOCATION REAR ELEVATION
2. AREA OF SIGN TO BE A GALVANIZE ALL STEEL AFTER FABRICATION
E MIN. OF 70 SQ. IN.
3. LETTERING TO BE 2" HIGH.
A
05 INTERNATIONAL 02
REVISIONS:
ELEVATION TYPICAL PARKING SIGNAGE SYMBOL OF ACCESSIBILITY
B REF: 11B-502 SCALE: 1/2" = 1'-0" REF: 11B-502.6.4 SCALE: 1" = 1'-0"
INDEX NO.
NO.
1/4" MTL. CAP
WELD TO TUBING
D WHEEL STOP, TYP. ACCESSIBLE VAN PARKING
SIGN, POLE MOUNTED.
CITY ENGINEER
DATE:
ACCESSIBLE CHARACTERS SHALL BE 2" HIGH
0.65" MIN. PARKING SPACE ISA MIN. PER SEC 11B-502
1/8" BASE TO BASE LOCATE OUTSIDE OF 18'-0" MIN
PARKING SPACE LENGTH
0.9"-0.92" BASE DIA.
MIN. 3" DIAGONAL STRIPES IN
A COLOR CONTRASTING WITH
0.45"-0.47" TOP DIA. 7'-0" CLR. THE PAVEMENT OF BLUE ON
2" DIA. X 1/4" CONCRETE AND WHITE ON
STEEL POST ASPHALT AND AT 3'-0"
B SPACING MAX. ON CENTER
C -
B PROVIDE VAN SURFACE OF PARKING
DESIGN GROUP
4" WIDE SPACE AND ACCESS AISLE
STRIPING NO DOES NOT EXCEED 2%
1/4"
IN WHITE PARKING GRADIENT IN ANY DIRECTION
(DOUBLE
2.3"-2.4" NOMINAL STRIPING EQ. EQ. BLUE BORDER
NOTE:
IS REQ'D) ON ALL 4 SIDES
REVERSE DETAIL FOR
CEILING MOUNTED STL POST (A) TRUNCATED DOME SPACING
12" TALL LETTERING
CENTERLINE PAINTED ON THE
9'-0" MIN. GROUND IN WHITE
B 1 1/2" x 1 1/2" x 1/4" 0.2" HEIGHT 0.9"-0.92" BASE DIA. ACCESSIBLE CROSSING AISLE
ACCESSIBLE PATH,
CUT ANGLE TO FIT TAPERED EDGES WHERE WHERE OCCURS
EXPOSED WHERE APPLICABLE - 5% MAX SLOPE
APPROVED BY:
AROUND TUBING 0.45"-0.47" TOP DIA.
DESIGNED BY:
CHECKED BY:
IN DIRECTION OF TRAVEL WITH 2% 5'-0" MIN
5'-0" MIN. ACCESS AISLE
DRAWN BY:
ENGINEER:
MAX. CROSSING SLOPE 8' -0" MIN. LOADING AISLE WIDTH
MIN. 4" WIDE STRIPING IN WHITE, TYP. 8'-0" MIN.
REQUIRED AT "ACCESSIBLE VAN"
NOTES: PARKING SPACE
SECTION (B) TRUNCATED DOME SECTION A-A
A 1. PAINT CURB MARKINGS AND METAL SIGNS COLOR: 15090 FEDERAL STANDARDS 595A AS
SPECIFIED IN SEC. 522(b) OF THE REGULATIONS. (SIMILAR TO ROYAL BLUE)
2. NEW AND EXISTING AC PARKING AND ACCESS WILL COMPLY WITH CA ADMINISTRATIVE WORK ORDER NO.
CODE 24, AND COUNTY OF LA PARKING CODE.
3. SURFACE SLOPES OF AC PARKING SPACES SHALL BE THE MIN. POSSIBLE AND SHALL NOT E170121B
(DESIGN STAGE ONLY)
07 04 01
REF: PLANS
PARKING SIGNAGE DETAIL
SCALE: 1"=6" REF: PLANS
TRUNCATED DOMES
SCALE: 3"=1'-0"
TYP. ACCESSIBLE PARKING
REF: PLANS (11B-208) SCALE: 1/8"=1'-0"
A0.26
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A026_24X36.DWG 12/3/2021 9:08 AM
REVISION DATES
(DESIGN STAGE ONLY)
G
K
D
H
A
E
F
1
1
2
2
3
3
4
4
5
5
6
6
7
7
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A027_24X36.DWG 12/3/2021 9:08 AM
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
PROJECT:
DRAWN BY:
X
APPROVED BY:
18210 SHERMAN WAY, RESEDA CA 91335
SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
PLAN CHECK CORRECTION NOTES REQUIRED BY THE CITY OF LOS ANGELES INSTALLATION).
ENGINEERING
GENERAL NOTES- PART III
A.3 GENERAL REQUIREMENTS GENERAL NOTES REQUIRED BY LAFD
K A. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED MEANS OF EGRESS SERVING A ROOM OR SPACE SHALL BE ILLUMINATED AT ALL TIMES THAT
ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL BOXES, THE ROOM OR SPACE IS OCCUPIED. THE ILLUMINATION LEVEL SHALL NOT BE < 1
TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC) OR TO THE FOOTCANDLE AT THE WORKING SURFACE.
LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY
POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL
COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. AUTOMATICALLY ILLUMINATE ALL OF THE FOLLOWING AREAS FOR A DURATION OF NOT < 90
MIN. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL
B. OMIT (NO GAS IN THIS FACILITY). ILLUMINATION THAT IS NOT LESS THAN AN AVERAGE OF 1 FOOTCANDLE AND A MIN AT ANY
POINT OF.1 FOOTCANDLE:
C. PROVIDE ULTRA-LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING I. AISLES.
SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. II. CORRIDORS.
III. EXIT ACCESS STAIRWAYS AND RAMPS.
J D. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE IV. INTERIOR AND EXTERIOR EXIT STAIRWAYS AND RAMPS.
AVAILABLE AT THE JOB SITE. V. PASSAGEWAYS.
VI. VESTIBULES AND AREAS ON THE LEVEL OF DISCHARGE USED FOR EXIT DISCHARGE.
H. 56-58 MEANS OF EGRESS GENERAL REQUIREMENTS VII. ELECTRICAL EQUIPMENT ROOMS
56.A. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. VIII. FIRE COMMAND CENTERS.
IX. FIRE PUMP ROOMS. 10/31/2023
B. EXIT SIGNS ILLUMINATED BY AN EXTERNAL SOURCE SHALL HAVE AN INTENSITY OF NOT LESS X. GENERATOR ROOMS.
THAN 5 FOOT CANDLES (54 LUX). XI. PUBLIC RESTROOMS> 300 SF.
C. INTERNALLY ILLUMINATED SIGNS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED.
ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND SECTION 2702.
TACTILE EXIT SIGNS SHALL BE REQUIRED AT THE FOLLOWING LOCATIONS:
I D. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. A. "EXIT" SIGN AT EACH GRADE -LEVEL EXTERIOR DOOR
B. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS
E. EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL PROVIDE OF A STAIRWAY OR RAMP SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE
K. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT
THE WALKING SURFACE. IN CASE OF PRIMARY POWER LOSS, THE SIGN ILLUMINATION MEANS SHALL BE CONNECTED
TO AN EMERGENCY POWER SYSTEM FOR A DURATION OF NOT < 90 MINUTES.
HORIZONTAL CONTROL:
L. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED
VERTICAL CONTROL:
BY THE PREMISES ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, AN
EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE THE FOLLOWING AREAS:
G
SHEET TITLE:
I. AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND SPACES THAT REQUIRE
ADDRESS:
PROJECT:
TWO OR MORE MEANS OF EGRESS..
II. CORRIDORS, EXIT ENCLOSURES AND EXIT PASSAGEWAYS IN BUILDINGS REQUIRED TO
HAVE TWO OR MORE EXITS.
III. EXTERIOR EGRESS COMPONENTS AT OTHER THAN THE LEVEL OF EXIT DISCHARGE IS
ACCOMPLISHED FOR BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS.
BY:
REQUIRED TO HAVE TWO OR MORE EXITS.
V. EXTERIOR LANDINGS, AS REQUIRED BY SECTION 1010.1.6, FOR EXIT DISCHARGE
DATE:
CIP NO.
DOORWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS.
F
57. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS
THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN
ON-SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE IN
ACCORDANCE WITH SECTION 2702.
J. BUILDING ENVELOPE
6. PROVIDE ANTI-GRAFFITI FINISH AT THE FIRST 9 FEET, MEASURED FROM GRADE, AT EXTERIOR
REVISIONS:
WALLS AND DOORS
INDEX NO.
BY MANUFACTURERS DESIGNATION SPECIFYING WHO APPLIED THE DESIGNATION, THE
MANUFACTURER OR INSTALLER AND THE SAFETY GLAZING STANDARD. THE FOLLOWING SHALL
NO.
BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF SAFETY GLAZING.
GLAZING IN:
D A. SWING DOORS.
B. FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND
CITY ENGINEER
DATE:
BI-FOLD CLOSET DOOR ASSEMBLIES.
C. STORM DOORS.
D. UNFRAMED SWINGING DOORS.
E. DOORS AND ENCLOSURES FOR HOT TUBES, WHIRLPOOLS, SAUNAS, STEAM ROOMS,
BATHTUBS AND SHOWERS.
F. FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED
EDGE OF THE GLAZING IS WITHIN 24 INCHES ARC OF EITHER VERTICAL EDGE OF THE DOOR
IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS
THAN 60 INCHES ABOVE THE WALKING SURFACE. READ CODE FOR EXCEPTIONS.
G. FIXED OR OPERABLE PANEL, OTHER THAN DESCRIBED IN ITEMS E AND F, WHICH MEETS
C ALL OF THE FOLLOWING CONDITIONS (READ CODE FOR EXCEPTION WITH SPECIAL
INSTALLATION).
DESIGN GROUP
I. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET.
II. EXPOSED BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR.
III. EXPOSED TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR.
IV. ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE
PLANE OF THE GLAZING.
APPROVED BY:
DESIGNED BY:
II. THE GLAZING IS WITHIN 60 INCHES OF A SWIMMING POOL OR SPA WATERS EDGE.
CHECKED BY:
DRAWN BY:
ENGINEER:
J. ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36 INCHES HORIZONTALLY OF
A WALKING SURFACE; WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60
INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE (READ CODE FOR
EXCEPTION WITH SPECIAL INSTALLATION).
K. ADJACENT TO STAIRWAYS WITHIN 60 INCHES HORIZONTALLY OF THE BOTTOM TREAD OF WORK ORDER NO.
A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS
THAN 60 INCHES ABOVE THE NOSE OF TREAD (READ CODE FOR EXCEPTION WITH SPECIAL E170121B
(DESIGN STAGE ONLY)
A SHEET NAME
REVISION DATES
A0.28
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A028_24X36.DWG 12/3/2021 9:08 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ICE SKATING FACILITY BUILDING AND SAFETY INFORMATION APPLICABLE CODES ICE SKATING BUILDING AREAS/ PLUMBING FIXTURE CALCULATION ENGINEERING
CONSTRUCTION GROSS AREA (INCLUDES BUILDING AREA WITHIN THE EXTERIOR WALLS): OCC. LOAD FOR PLUMBING FIXTURES PER
I. 2019 LA AMENDMENT BUILDING CODE LOAD FACTOR (PER TABLE
23,902 SF MEMBRANE STRUCTURE: TYPE II-B (SEE NOTES BELOW) SPACE AREA (S.F.) OCCUPANCY OCC. LOAD REQ'D EXITS TABLE A SECT. 422.1 LAPC (LOAD FACTORS:
II. 2019 LA AMENDMENT GREEN BUILDING CODE 1004.5 &1004.6)
K 3,670 SF CMU STRUCTURE : TYPE II-B A.2=30, B=200, S=5,000)
III. 2019 LA AMENDMENT ELECTRICAL CODE
OCCUPANCY CLASSIFICATION FOR SKATING RINK PER CBC 303.5 = A-4. IV. 2019 LA AMENDMENT MECHANICAL CODE NEW ONE-STORY BUILDING, TYPE II-B HYBRID (MEMBRANE & CMU) WITH NEW FIRE SPRINKLER SYSTEM
BUILDING HAS MINOR "B" AND "S" OCCUPANCIES V. 2019 LA AMENDMENT PLUMBING CODE
ICE RESURFACER ROOM 580 S-2 300 GROSS 1.94 1 0.12
VII. 2019 LA AMENDMENT FIRE CODE
NFPA 13 SPRINKLERED BUILDING W/ VOICE EVACUATION FIRE ALARM SYSTEM VIII. CITY'S GREEN BUILDING ORDINANCE LOBBY 3,780 A-4 15 NET 252 2 126
IX. TITLE 24 STANDARDS
BUILDING CODE LIMITS PER CBC TABLES 504.3, 504.4 & 506.2 OFFICE 400 B 150 GROSS 2.67 1 2
(FOR ONE STORY BUILDING, SPRINKLERED) X.
XI. LOW IMPACT DEVELOPMENT (LID) SKATE STORAGE 82 B 150 GROSS 0.55 1 0.41
ALLOWABLE STORIES ALLOWABLE HEIGHT XII. STANDARD URBAN STORMWATER MITIGATION PLAN (SUSMP)
OCC. TYPE ALLOWABLE AREA (SM)
ABOVE GRADE PLANE (NS) ABOVE GRADE PLANE (NS) BREAK ROOM 100 B 150 GROSS 0.67 1 0.5
A-4 II-B 2 STORIES 55 FT 38,000 SF
J RESTROOMS 420 ACCESSORY TO A-4 - - - -
B II-B 3 STORIES 55 FT 92,000 SF ICE SKATING BUILDING FLOOR AREA SUMMARY
JANITOR 35 S-2 300 GROSS 0.22 1 0.013
S-2 II-B 2 STORIES 55 FT 70,000 SF
VESTIBULE 120 A-4 15 NET 8 1 4
ICE ROOM 760 S-2 300 GROSS 2.53 1 0.15
BUILDING HEIGHT: PER CBC 202, "GRADE PLANE" IS "A REFERENCE PLANE REPRESENTING THE AVERAGE OF (BUILDING AREAS WITHIN EXTERIOR 10/31/2023
FINISHED GROUND LEVEL ADJOINING THE BUILDING AT EXTERIOR WALLS. WHERE THE FINISHED GROUND LEVEL WALLS, INCLUDES INTERIOR WALLS) ELEC. MECH. ROOM 427 S-2 300 GROSS 1.42 1 0.085
SLOPES AWAY FROM THE EXTERIOR WALLS, THE REFERENCE PLANE SHALL BE ESTABLISHED BY THE LOWEST
POINTS WITHIN THE AREA BETWEEN THE BUILDING AND THE LOT LINE, OR, WHERE THE LOT LINE IS MORE THAN 6 REF. ROOM 90 A-4 50 GROSS 1.8 1 3
TYPE II-B
FEET FROM THE BUILDING, BETWEEN THE BUILDING AND A POINT 6 FEET FROM THE BUILDING". REF. BATHROOM 60 ACCESSORY TO A-4 - - - -
A-4=24,922 SF
AVERAGE FINISHED GRADE (SEE PLOT PLAN 01/A0.30 FOR CALCULATION): 739.27' S-2=2,000 SF GIRL'S ROOM 55 A-4 50 GROSS 1 1 1.9
I BUILDING HEIGHT PROVIDED = MAX. 42'-6" @ SPRUNG RIDGE (781.77')
B=650 SF GIRL'S BATHROOM 60 ACCESSORY TO A-4 - - - -
FLOOR AREA: PER CBC SECT. 508.4: IN EACH STORY THE BUILDING AREA SHALL BE SUCH THAT THE SUM OF THE
LOCKER ROOM 1 308 A-4 50 GROSS 6.16 1 10.27
RATIOS OF THE ACTUAL BUILDING AREA OF EACH SEPARATED OCCUPANCY DIVIDED BY THE ALLOWABLE BUILDING
HORIZONTAL CONTROL:
2019 CBC SECTIONS 3102.1 THROUGH 3102.8. INTERIOR NON-BEARING 0
VERTICAL CONTROL:
PER CBC 2019 SECTION 3102.3: NON-COMBUSTIBLE FRAME OR CABLE-SUPPORTED STRUCTURES COVERED BY AN FLOOR CONSTRUCTION 0 TOTAL PLUMBING FIXTURE CALCULATION PER LAPC TABLE 422.1 (USING OCC. LOAD FOR PLUMB. FIXTURES)
G APPROVED MEMBRANE IN ACCORDANCE WITH SECTION 3102.3.1 SHALL BE CLASSIFIED AS TYPE II B ROOF CONSTRUCTION 0 OCC. LOAD WATER CLOSET URINAL LAVATORY DRINKING FOUNTAIN
SHEET TITLE:
CONSTRUCTION.
ADDRESS:
* NOT LESS THAN FIRE RATING BASED ON FIRE SEPARATION DISTANCE PER TABLE 602.
PROJECT:
THE ARCHITECTURAL MEMBRANE WHICH WILL BE UTILIZED NEEDS TO HAVE PASSED FIRE TEST PROTOCOLS TO
A-4 REQUIRED TOTAL A-4: 788 OCC. MALE:3, FEMALE:8 MALE:3 MALE:2, FEMALE:5 3
MEET THE INTENT OF THE FIRE PROPAGATION REQUIREMENTS AS OUTLINED IN THE BUILDING CODE.
MAX. AREA OF EXTERIOR WALL OPENINGS PER TABLE 705.8 FIRE SEPARATION DISTANCE 394 MALES, 394 FEMALES
A-4 PROVIDED
THE FRAME SHALL NOT BURN AND WILL BE NON-COMBUSTIBLE. CLASS. OF 5 - < 10 10 - < 15 15 - < 20 20 - < 25 25 - < 30
0 - < 3 FT. 3 - < 5 FT > 30 FT MALE:1, 1
OPENING FT FT FT FT FT B REQUIRED MALE:1, FEMALE:1** MALE:1**
BY:
THE MEMBRANE SHALL MEET THE REQUIREMENTS OF SECTION 803.1 WITH A CLASS A RATING. THE MEMBRANE
1 UNISEX
1 UNISEX
UNPROTECTED/ NOT NOT 2.16 MALES, 2.16 FEMALES
SHALL HAVE A FLAME SPREAD OF 25 OR LESS AND A SMOKED DEVELOPED INDEX OF 450 OR LESS AS PER THE
NONE
15% 25% 45% 75 NO LIMIT NO LIMIT B PROVIDED
TESTING REQUIREMENTS OF ASTM-E-84. SPRINKLERED PERMITTED REQUIRED
DATE:
CIP NO.
NOT MALE:1, 1
NOT S-2 REQUIRED TOTAL S: 0.37 OCC.** MALE:1, FEMALE:1** NONE**
PROTECTED 15% 25% 45% 75 NO LIMIT NO LIMIT FEMALE:1**
THE ARCHITECTURAL MEMBRANE IS CONSIDERED NON-RATED. THE OVERALL FRAME IS CONSIDERED PERMITTED REQUIRED
F NON-COMBUSTIBLE. AS SUCH, THE STRUCTURE CAN BE CONSIDERED TO MEET THE REQUIREMENTS OF A TYPE II S-2 PROVIDED
0.185 MALES, 0.185 FEMALES
B CONSTRUCTION.
TOTAL REQUIRED 12** 3** 8** 5
CULTURAL AFFAIRS APPROVAL (SEE SHEETS A0.02,A2.00, A8.30-A8.34) TOTAL PROVIDED 12 3 12 6 ***
REVISIONS:
LEGAL DESCRIPTION: ASSESSOR PARCEL NUMBER (APN) 2125036902, 2125036903
TRACT: TR 21799
(E) FIRE HYDRANT ADJ. PROPERTY ADJ. PROPERTY
INDEX NO.
PROJECT SITE ADDRESS: 18210 SHERMAN WAY, RESEDA CA 91335 PER SURVEY 211'-8" FROM (E) HYDRANT TO (N) FDC
PARCEL AREA: NORTH LOT= 16,848.1 SF
NO.
SOUTH LOT= 34,484.3 SF (27,850 SF ORIGINAL LOT+ 6,634.3 SF OF THE ADDITIONAL 20'-0"
TO-BE-ACQUIRED LAND) 160'-6 5/8" FROM TO ALLEY 265'-0 3/8" FROM TO
TOTAL= 51,332.4 SF 24'-5 1/2"
D
CITY ENGINEER
BUILDING FOOTPRINT (INCLUDES ALL BUILDING AND COVERED AREAS)= 28,445 SF (ONLY ON SOUTH LOT) (N) POWER 14'-4 7/8" 10'-9 1/2"
DATE:
739.86 739.12
POLE 239'-10" ICE RINK BLDG.
SHERMAN WAY
739.86
THE TWO LOTS ARE DESIGNATED AS [Q] C2-1L-CDO AND [Q] P-1L-CDO. HOWEVER THEY HAVE BEEN ACQUIRED BY 739.10
ELEC. EQUIPMENT PARKING 739.62 739.38
THE DEPARTMENT OF RECREATION AND PARKS, CITY OF LOS ANGELES AND WILL BE RE-ZONED AND CHAIN LINK FENCE 739.63
ZONE 739.39 ROOF EQUIPMENT CONTROL POINT
RE-DESIGNATED TO OPEN SPACE (SEE A0.31). UNDER CURRENT ZONING [Q] P-1L-CDO, MAX. HEIGHT IS UNLIMITED.
GRADE PLANE CALCULATIONS
10'-2"
1. SEE A0.31, A0.32 FOR CEQA NOE. TYPE II-B,CMU 4,020 SF GROSS
10'-1"
LANDSCAPE 1- STORY, 12'-0" @ PARAPET ELEVATION SYMBOL 739.10
SUMP PUMP CLR.
ALLEY
2. COMMUNITY PLANNING AREA: RESEDA- WEST VAN NUYS.
ADJ. PROPERTY
C 4. NEIGHBORHOOD COUNCIL: RESEDA
SIDEWALK PER CBC 202:
(739.10+739.86+739.38+739.62+
DESIGN GROUP
739.48 739.47+739.37+739.24+739.33+
5. ZONING INFO: ZI-2339 739.47 TYPE II-B NON-RATED MEMBRANE 739.14+738.24) / 10= 739.27'
TO
BENCH
SLOPE
STRUCTURE 24,215 SF GROSS GRADE PLANE AVERAGE
6. COMMUNITY DESIGN OVERLAY DISTRICT: RESEDA CENTRAL BUSINESS DISTRICT 739.38 1- STORY
105'-0 1/4" FROM
SLOPE
TURNAROUND GRADE PER LAMC 12.03
FIRE LANE
APPROVED BY:
7 SHORT TERM BIKE PARKING
10'-9 1/4"
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ADJ. PROPERTY
ENGINEER:
(E) SCHOOL
(CONTRACTOR IS RESPONSIBLE FOR DESIGN,
DEFERRED SUBMITTALS ENGINEERING, PLAN CHECK & PERMIT.)
BUILDING (E) POWER POLE
GATES SHALL REMAIN OPEN FDC @ GATEWAY WALL
THE FOLLOWING ITEMS SHALL BE DEFERRED SUBMITTALS: DURING THE ICE RINK'S
739.24 738.25
BUSINESS HOURS ROOF OF GATEWAY
10'-1 1/4"
- MEMBRANE STRUCTURE (MEMBRANE SYSTEM AND ATTACHMENTS). DESIGN INTENT & PERFORMANCE CRITERIA 739.27 5' OFFSET OF BUILDING
738.24 WORK ORDER NO.
CLR.
OUTLINED THROUGHOUT THESE DOCUMENTS. IF ALTERNATIVE SYSTEM THAN THE ONE SPECIFIED IN PARCEL 1 ON SHT. A0.09 FOOTPRINT
739.33
INCLUDING THE ADD'AL 25'-0"
ARCHITECTURAL/ STRUCTURAL DRAWINGS IS USED FOR PAVILION, A SUPPLEMENTAL PERMIT AND PLAN CHECK 739.36 (N) WALL ON E170121B
(DESIGN STAGE ONLY)
WILL BE REQUIRED. APPROVAL OF STRUCTURAL ENGINEER AND ARCHITECT OF RECORD IS REQUIRED. THE 739.14 6' OFFSET OF BUILDING
(E) WALL ON
A SYSTEM SHALL COMPLY WITH THE ACCEPTANCE CRITERIA (LARR OR ICC-ESR#) WITH ALL THE CONDITIONS OF 739.16 FOOTPRINT
01 SHEET NAME
REVISION DATES
APPROVAL.
- FIRE DETECTION & VOICE ALARM COMMUNICATION SYSTEM DESIGN
N
A0.30
ADJ. PROPERTY
- FIRE SPRINKLER SYSTEM DESIGN (NFPA 13) PLOT PLAN
-STOREFRONT/ CURTAIN WALL ENGINEERING
-CHAIN LINK FENCE (DESIGN INTENT PER 01/ A8.32) REF: SRV, A0.09, A1.00 SCALE: 1/32" = 1'-0"
X
SHEETX OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A030_24X36.DWG 12/14/2021 11:00 AM
REVISION DATES
(DESIGN STAGE ONLY)
G
K
D
H
A
E
F
1
1
2
2
3
3
4
4
5
5
6
6
7
7
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A031_24X36.DWG 12/3/2021 9:09 AM
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
PROJECT:
DRAWN BY:
X
APPROVED BY:
18210 SHERMAN WAY, RESEDA CA 91335
SHEETS
REVISION DATES
(DESIGN STAGE ONLY)
G
K
D
H
A
E
F
1
1
2
2
3
3
4
4
5
5
6
6
7
7
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A0.32_24X36.DWG 12/3/2021 9:09 AM
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
PROJECT:
DRAWN BY:
X
APPROVED BY:
18210 SHERMAN WAY, RESEDA CA 91335
SHEETS
REVISION DATES
(DESIGN STAGE ONLY)
G
K
D
H
A
E
F
1
1
2
2
3
3
4
4
5
5
6
6
7
7
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A0.33_24X36.DWG 12/3/2021 9:09 AM
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
PROJECT:
DRAWN BY:
X
APPROVED BY:
18210 SHERMAN WAY, RESEDA CA 91335
SHEETS
REVISION DATES
(DESIGN STAGE ONLY)
G
K
D
H
A
E
F
1
1
2
2
3
3
4
4
5
5
6
6
7
7
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A034_24X36.DWG 12/3/2021 9:09 AM
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
PROJECT:
DRAWN BY:
X
APPROVED BY:
18210 SHERMAN WAY, RESEDA CA 91335
SHEETS
REVISION DATES
(DESIGN STAGE ONLY)
G
K
D
H
A
E
F
1
1
2
2
3
3
4
4
5
5
6
6
7
7
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A035_24X36.DWG 12/3/2021 9:10 AM
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
PROJECT:
DRAWN BY:
X
APPROVED BY:
18210 SHERMAN WAY, RESEDA CA 91335
SHEETS
REVISION DATES
(DESIGN STAGE ONLY)
G
K
D
H
A
E
F
1
1
2
2
3
3
4
4
5
5
6
6
7
7
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A036_24X36.DWG 12/3/2021 9:10 AM
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
PROJECT:
DRAWN BY:
X
APPROVED BY:
18210 SHERMAN WAY, RESEDA CA 91335
SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
K SHERMAN WAY
81
ETIWANDA AVE.
J
LINDLEY AVE.
379 PUBLIC ALLEY 438
10/31/2023
100
HORIZONTAL CONTROL:
VERTICAL CONTROL:
211'-0 5/8"
G 20'-0" DISTANCE BETWEEN 2 BUILDING EXITS
SHEET TITLE:
PER CBC 1029.3.1 VESTIBULE
ADDRESS:
PROJECT:
OCC: A-4
ICE ROOM GIRLS' ROOM REF. ROOM SHARED BATHROOM 1 SHARED BATHROOM 2
120 SF/15= 8 OCC: S-2 OCC: A-4 OCC: A-4 ACCESSORY TO A-4 ACCESSORY TO A-4
760 SF/300 = 3 55 SF/50 = 1 90 SF/50 = 2 207 SF 207 SF
BREAK ROOM
OCC: B 2 ROWS / 1'-6" PER BATHROOM
PERSON (1004.6) ACCESSORY TO A-4
BY:
SEATING A ELEC. MECH. ROOM BATHROOM LOCKER ROOM A LOCKER ROOM B LOCKER ROOM C LOCKER ROOM D
10'-0"MIN.
10'-2"CLR.
OCC: A-4 OCC: S-2 ACCESSORY TO A-4 OCC: A-4 OCC: A-4 OCC: A-4 OCC: A-4
12+28+31 427 SF/300 = 2 60 SF 308 SF/50 = 7 308 SF/50 = 7 308 SF/50 = 7 308 SF/50 = 7
DATE:
47'-4''/1'-6"=31
CIP NO.
+170= 203
203+154+81= 438
EXIT E
F 438 191
191+3+9= 203 01
203
02
07 07 07 07
03 02
01 08 *
120
4'-0" MIN.
28'-0" TURNAROUND NOTE A NOTE A
4'-10"
SEATING B SEATING C
NOTE A OCC: A-4 OCC: A-4 21+31+2
E 42'-0'' / 1'-6"= 28 47'-4"/ 1'-6"= 31 +170= 224
ALLEY
SKATE SHARP. 2 ROWS / 1'-6" PER 2 ROWS / 1'-6" PER EXIT D
OCC: B 01 01 PERSON (1004.6) PERSON (1004.6) 224
S
SEATING D
*
IT
82 SF/150=1
68'-2" HAMMERHEAD/ TURNAROUND (70'-0" REQ'ED)
OCC: A-4
EX
REVISIONS:
118'/1'-6"=78
NK
OFFICE
ACCEPTABLE PER LAFD CAPTAIN MITTINO
RI
1 ROW / 1'-6" PER OCC: B
E
N 2"
IC
PERSON (1004.6) 400 SF/150 = 3
INDEX NO.
198
EE 1/
'-2 3
2
170
TW 1'-1
/
1/3 4" ICE
XD R
NO.
39 " 03 IAG INK D
8'-0 ONA IA
L = GONA
R2
BE
66'-
9" L 2'-11 1/2"
CE
EXIT A1 39 R2
D 42 42 8'-
AN
81 0" 132 261 ICE RINK
ST
CITY ENGINEER
ROLLER/SKATE PARK 154 '-3
1/4 A-4
DATE:
39+42=81
DI
A-4 1/3 "
X D BUILD 17,013 SF/50 = 340
* EXIT TO SHERMAN WAY 4,200 SF/50 = 84 * EXIT A2
170 IAG ING
ON
81 170+132+6= 307 NOTE A AL DIAG
=8 O
39+42=81 7'-1 NAL
EXIT B * * "
(N) 30'-0" DRIVEWAY
28'-0" FIRELANE
307
LOBBY
OCC: A-4
3,780 SF/15 = 252
153
C
02
DESIGN GROUP
2'-0"
68'-0" FROM SHERMAN WAY TO GATES SHALL REMAIN OPEN DURING THE ICE RINK'S OCC: S-2
BUSINESS HOURS APPROVED PER CFC 503.6 580 SF/300 = 2
*
PAINTED ASPHALT SURFACE, OPEN TO
* 226
226+153= 379
BACK OF HOUSE
10'-0''
APPROVED BY:
OCC: S-2
DESIGNED BY:
CHECKED BY:
EGRESS COURT PER CBC 1028.4 SHALL 675 SF/300 = 2
DRAWN BY:
ENGINEER:
BE 10'-0'' MIN CLR. PER CBC 1028.4.2.
109'-5" FIRE LANE 239'-10" EGRESS FROM BACK OF HOUSE
2'-0"
10'-1"
10'-0''CLR. MIN.
WORK ORDER NO.
E170121B
01
(DESIGN STAGE ONLY)
A
FIRST FLOOR/ SITE PLAN MEANS OF EGRESS/ FIRE LANE SHEET NAME
REVISION DATES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A041_24X36.DWG 12/3/2021 9:10 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
10/31/2023
EXITING NOTES:
HORIZONTAL CONTROL:
VERTICAL CONTROL:
2. EXIT ACCESS (250'-0'' MAX. PER TABLE 1017.2, FOR 'A' OCC, W/
SPRINKLER SYSTEM, MOST RESTRICTIVE)
G
SHEET TITLE:
3. PER 1029.2, THE MAIN EXIT SHALL BE OF SUFFICIENT CAPACITY TO TO
ADDRESS:
PROJECT:
ACCOMMODATE NOT LESS THAN ONE HALF OF THE OCCUPANT LOAD,
BUT SUCH CAPACITY SHALL BE NOT LESS THAN THE TOTAL REQUIRED
CAPACITY OF ALL MEANS OF EGRESS LEADING TO THE EXIT.
DATE:
CIP NO.
ALLEY
6. LOCATIONS OF PORTABLE FIRE EXTINGUISHERS SHOWN TO COMPLY
WITH LIGHT HAZARD OCCUPANCY PER CBC T906.3(1)
F
FIRE PROTECTION NOTES:
1. THIS BUILDING MUST BE EQUIPPED WITH AN AUTOMATIC FIRE COMMON PATH = 19'-3'' COMMON PATH = 19'-3''
EXTINGUISHING SYSTEM, COMPLYING WITH NFPA 13; THE SPRINKLER
SYSTEM SHALL BE APPROVED BY PLUMBING DIV. PRIOR TO INSTALLATION.
REVISIONS:
LEGEND
INDEX NO.
ALLEY
NO.
EXIT ACCESS EXIT D
''
79'-2
D COMMON PATH OF TRAVEL A-4 OCCUPANCY
CITY ENGINEER
EXIT
COMMON
DATE:
FE
TOTA
EXIT DISCHARGE PATH = 28'-8''
L TO -B
" EXIT D 1/2"
L TO E
'- 2 1 /2
23 6 78'-
ONAL =
A
MOST REMOTE POINT FOR EGRESS IA G
TOT
1/3 X D
XIT =
WALL MOUNTED EXIT SIGN
124'-1
TO
132'-8''
TOTAL TO O EXIT =
FE FIRE EXTINGUISHER TOTAL T
''
DESIGN GROUP
II-B, OCCUPANCY A-4.
APPROVED BY:
TOTAL TO EXIT = 103'-4'' TOTAL TO EXIT = 165'-3''
DESIGNED BY:
CHECKED BY:
1-HOUR SEPARATION AND/OR PROTECTION
DRAWN BY:
ENGINEER:
PER CBC TABLE 509 (REFRIGERANT
MACHINE ROOM.) S OCCUPANCY
ACCESSORY TO
EXIT C A-4
CMU- TYPE II-B STRUCTURE
WORK ORDER NO.
E170121B
01
(DESIGN STAGE ONLY)
A
FIRE RATED WALL DIAGRAM/ OCCUPANCY SEPARATIONS & EXIT ACCESS TRAVEL DISTANCE SHEET NAME
REVISION DATES
N
REF: A0.41 SCALE: 1/16" = 1'-0"
A0.42
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A042_24X36.DWG 12/3/2021 9:10 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
BEARING
F.O.CMU
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
WALL
265'-0 3/8" 130'-0 1/4"
14'-5 3/8" 239'-10" FROM F.O. BLDG TO F.O. BLDG 10'-9" 10'-9 3/8" 119'-1" FROM F.O. BLDG TO F.O. BLDG
10/31/2023
14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2" 11'-4" 19'-0" 16'-0" 9'-4 1/2" 16'-0" 19'-0" 9'-9 1/2" 18'-1" 2"
+ 42'-6"
I +42'-6"
T.O. BLDG & GATEWAY
+ 42'-6"
T.O RIDGE @ MEMBRANE
T.O RIDGE @ MEMBRANE
& GATEWAY
& GATEWAY
+22'-0"
NOTE: GATE TO OPEN T.O. SCREEN EQUIPMENT
SIDEYARD NOT
COUNTED +12'-0"
T.O CMU PARAPET
ALLOWABLE OPENINGS
T.O HOOD @ EXIT DOOR +8'-4 1/2"
T.O CMU WALL ON P.L
+0'-6"
T.O.CONC. CURB 0-4 1/2"
0'-0" T.O GRADE (739.81')
T.O.S (739.43')
0'-0"
-1'-3 1/2"
T.O.S (739.43')
T.O GRADE (737.87')
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G OPENINGS PER FLOOR OPENINGS PER FLOOR
SHEET TITLE:
OPENINGS (SF) / TOTAL AREA (SF) = % OPEN % ALLOWED
ADDRESS:
OPENINGS (SF) / TOTAL AREA (SF) = % OPEN % ALLOWED
PROJECT:
MEMBRANE STRUCTURE 42 / 14,500 = 0.2 < 45 MEMBRANE STRUCTURE 21 / 2,900 = 0 < 45
PER TABLE 705.8, UNPROTECTED, SPRINKLERED BUILDING AT 10' TO LESS THAN 15' CMU BUILDING 0 / 183 = 0 < 45
PER TABLE 705.8, UNPROTECTED, SPRINKLERED BUILDING AT 10' TO LESS THAN 15'
BY:
THE BUILDING WALL. PROJECTION SHALL COMPLY WITH CBC SECTION 705.2.
DATE:
CIP NO.
F 05 02
WEST ELEVATION SOUTH ELEVATION
REF: 02/A2.01 SCALE: 1/16" = 1'-0" REF: 02/A2.00 SCALE: 1/16" = 1'-0"
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
BEARING
F.O.CMU
BLDG.
BLDG.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
F.O.
F.O.
WALL
265'-0 3/8" 130'-0 1/4"
REVISIONS:
239'-10" FROM F.O. BLDG TO F.O. BLDG 14'-4 7/8" 6'-0" TO F.O. GATEWAY 119'-1" FROM F.O. BLDG TO F.O. BLDG 10'-9 1/4"
10'-9 1/2" 14'-0 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-9 1/2" 0" 19'-0"
0'- 18'-1" 9'-9 1/2" 19'-0" 16'-0" 9'-4 1/2" 16'-0" 11'-4"
6" 6" R1 2" 6"
INDEX NO.
NO.
+ 42'-6" +42'-6" + 42'-6"
D T.O RIDGE @ MEMBRANE T.O. BLDG & GATEWAY T.O RIDGE @ MEMBRANE
& GATEWAY
& GATEWAY CMU BUILDING A
CITY ENGINEER
DATE:
CMU BUILDING B
ALLEY
CMU BUILDING A CMU BUILDING B
CITY OF
LOS ANGELES
+12'-0"
T.O CMU PARAPET
+12'-0" +11'-3 3/4"
+9'-7 1/2" T.O HOOD @ EXIT DOOR
T.O. PARAPET @ CMU BLDG.
C B.O MTL. DECK
+8'- 4 1/2"
+7'-8 1/2"
T.O CMU WALL ON P.L
DESIGN GROUP
T.O CMU WALL ON P.L
+0'-6"
0'-4 1/2" T.O.CONC. CURB
T.O GRADE (739.81')
0'-0"
0'-0" T.O.S (739.43')
T.O.S (739.43') -0'- 3 1/2"
NOTE: GATE TO OPEN T.O GRADE (739.14')
SIDEYARD NOT
COUNTED
APPROVED BY:
DESIGNED BY:
CHECKED BY:
CMU BUILDING A 0 / 2,075 = 0 < NOT CMU BUILDING A 42 / 100 = 42 < UNLIMITED**
DRAWN BY:
ENGINEER:
CMU BUILDING B 0 / 83 = 0 < UNLIMITED*
CMU BUILDING B 63 / 330 = 19 < 45
* PER TABLE 705.8, UNPROTECTED, SPRINKLERED BUILDING AT 20' TO LESS THAN 25'.
PER TABLE 705.8, UNPROTECTED, SPRINKLERED BUILDING AT 15' TO LESS THAN 20'.
** PER TABLE 705.8, UNPROTECTED, SPRINKLERED BUILDING AT 30' OR GREATER
WORK ORDER NO.
NOTE: FIRE SEPARATION DISTANCE MEASURED FROM THE CENTER LINE OF THE ALLEY, FOR NORTH ELEVATION OPENINGS.
04 01 E170121B
(DESIGN STAGE ONLY)
REF: 01/A2.01 SCALE: 1/16" = 1'-0" REF: 01/A2.00 SCALE: 1/16" = 1'-0"
A0.43
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A043_24X36.DWG 2/4/2022 10:06 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
K
ICE ARENA
739.43 F.F.
J
ACCESSIBLE/ SLED HOCKEY PLAYERS' BOXES, FF&E ACCESSIBLE/ SLED HOCKEY PLAYERS' BOXES, FF&E
739.43 F.F.
739.43 F.F.
10/31/2023
3'-7 1/2"
5'-0" 4'-0" 25'-0" BENCH, SEE R- DRAWINGS 4'-0" 5'-0" 5'-0" 4'-0" 25'-0" BENCH, SEE R- DRAWINGS
11B-221.2.1.4
11B-221.2.1.4
30"X48" PER
30"X48" PER
6'-0"
1'-0"
UP
1'-8"
30"X48"
3'-3"
739.43 F.F.
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G
SHEET TITLE:
ADDRESS:
PROJECT:
LEGEND
DATE:
CIP NO.
5'-0"
F
5'-0"
12'-0"
LANDSCAPE
5'-0"
739.46 F.F.
(E) ACC.
VAN
12'-0"
SIDEWALK 739.43 F.F
E
ALLEY
BENCH
REVISIONS:
INDEX NO.
NO.
TREES IN
TREE WELLS
D ICE ARENA
CITY ENGINEER
DATE:
ACCESSIBLE/ SLED ACCESSIBLE/
ROLLER PARKSLED
HOCKEY PLAYERS' HOCKEY
OPEN PLAYERS'
TO THE SKY
PAINTED
BOXES, FF&E BOXES, FF&E
GRAPHIC 3'-0"
LINES
739.43 F.F
4'-0"
739.46 F.F
FIRE LANE
C
DETECTABLE
DESIGN GROUP
WARNING SIGNS
SPEED BUMPS SL SL
APPROVED BY:
DESIGNED BY:
CHECKED BY:
GUTTER PER SURVEY
DRAWN BY:
ENGINEER:
03
-
WORK ORDER NO.
E170121B
(DESIGN STAGE ONLY)
A SHEET NAME
REVISION DATES
A0.50
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A0.50_24X36.DWG 12/3/2021 9:11 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
SHERMAN WAY
K
05
A0.30
01
A0.30
J
ALLEY
03
10/31/2023
A0.30 02
A0.30
I 04
A0.30
SHEET TITLE:
ADDRESS:
PROJECT:
DEPARTMENT OF PUBLIC WORKS
BY:
DATE:
CIP NO.
F
REVISIONS:
05 02
INDEX NO.
VIEW OF THE TWO LOTS FROM THE ALLEY FACING EAST NORTH LOT VIEW FROM THE ALLEY
NO.
REF: 06/- SCALE: N/A REF: 06/- SCALE: N/A
D
CITY ENGINEER
DATE:
C
DESIGN GROUP
CITY OF LOS ANGELES
B
APPROVED BY:
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
WORK ORDER NO.
E170121B
(DESIGN STAGE ONLY)
A
04 01 SHEET NAME
REVISION DATES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A090_24X36.DWG 12/3/2021 9:11 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
K 01
A1.10
(E) FIRE
HYDRANT
01
ADJ. ADJ.
(E) PED. RAMP PROPERTY
A8.34 0.9 PROPERTY 17.1
BLDG.
BLDG.
F.O.
F.O.
J 01
A8.30
20'-0" 265'-0 3/8" FROM TO PER SURVEY ON SHT. A0.09
160'-6 5/8" FROM TO
PER SURVEY 10" ALLEY
(E) LIGHT & 120'-0" 39'-8 5/8" 10'-0" 10'-0" 8'-4 7/8" 6'-0" 239'-10" ICE RINK BLDG 10'-9 1/2" 10/31/2023
TRAFFIC SIGN
SECURITY FENCE (CHAIN SPEED BUMP DISTRIBUTION
(E) DRIVEWAY LINK) ON. CONC. CURB (N) POWER F.O. F.O.
POLE A SWITCHBOARD PAD
CMU
A
CMU 739.81 739.69
06
I
10'-1"
BIO-FILTRATION PLANTER CROSSWALK CLR.
WARNING SIGN
EVCS
PLANTER,
33'-10"
SEE LAND.
DWGS
739.46 F.F
(E) PROPOSED
(E) CURB SIDEWALK DWP
VAN ACC
ACCESS
ALLEY
SUMP PIT, SEE CIVIL DWGS. 32.07 ALSO SEE LAND. DWGS
05
PER SURVEY
ICE RINK
36'-10 1/4"
SITE PLAN
(N) CONCRETE SURFACE
ELEC. PEDESTAL PROPOSED (E) POWER
(E) PALM TREE
HORIZONTAL CONTROL:
FOR NORTH LOT TRANSFORMER POLE
VERTICAL CONTROL:
SERVICE PAD
32.02 ON AC
SHEET TITLE:
32.14 DUMPSTERS (E) 739.28
SECURITY FENCE
ADDRESS:
TO
PROJECT:
ROLLER RINK (E) 738.93
4'-4"
4'-0"
(N) ASPHALT PARKING 02
(N) 30'-0" DRIVEWAY
739.46 F.F
28'-0" FIRE LANE
BY:
THE ALLEY SURFACE
04
DATE:
CIP NO.
PAINTED GRAPHICS ON AC GATEWAY OVERHANG
01 SEE ELEVATIONS.
SEE LANDSCAPE DWGS.
F
(E) CONC. GUTTER
2'-0"
739.43 F.F
SECURITY GATES. GATES SHALL REMAIN OPEN
68'-0" FROM SHERMAN WAY TO SPEED BUMP
DURING THE FACILITY'S BUSINESS HOURS
F.O.
I.1
10'-0"MIN.
(E) PALM TREE BLDG.
10'-1 1/4"
10'-9 1/4"
CLR.
(E) BUILDING (N) CONCRETE SURFACE 738.33
TRENCH DRAIN
(E) STREET LIGHT PER CIVIL SEE CIVIL DWGS 738.17
E
CROSSWALK
WARNING SIGN
8'-0" CMU SITE WALL. F.O.
SHERMAN WAY
REVISIONS:
109'-5 1/4" FIRE LANE 239'-10" 10'-9"
2'-0"
(E) BLOCK
INDEX NO.
ADJ.
03 WALL 5-'6"
BLDG.
BLDG.
(E) BIKE BAR PROPERTY
PER SRVY
F.O.
F.O.
NO.
D 0.9 17.1
CITY ENGINEER
DATE:
NOTES:
1. ALL ELEVATION BUBBLES 01 ON THIS SHEET REFER TO SHEET A0.02 3D MODEL IMAGES. SEE A2.00 & A2.01 FOR TECHNICAL ELEVATIONS THAT ARE CROSS-REFERENCED ON PLANS.
C 2. ELEVATIONS @ CORNER OF PROPERTY AND DIMENSIONS NOT SHOWN ON SURVEY ARE EXTRAPOLIATED FROM SURVEY. CONTRACTOR SHALL VERIFY ALL PROPERTY DIMENSIONS, CORNERS AND ELEVATIONS W/ 01
SURVEYING EQUIPMENT PRIOR TO BEGINING CONSTRUCTION AND NOTIFY ARCHITECT OF ANY DISCREPANCY OF (E) ELEVATIONS OR (E) PROPERTY DIMENSIONS. ARCHITECT SHALL BE COMPENSATED BY OWNER
SITE PLAN
DESIGN GROUP
FOR ANY CHANGES DUE TO INCOMPLETE SURVEY. N
REF: SURVEY, A0.09, A0.30, A0.41,A0.50 SCALE: 1/16" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A1.00
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A100_24X36.DWG 12/3/2021 9:11 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
(E) FIRE
HYDRANT
ADJ. ADJ.
(E) PED. RAMP PROPERTY 0.9 PROPERTY 17.1
BLDG.
BLDG.
F.O.
F.O.
J
20'-0" 265'-0 3/8" FROM TO PER SURVEY ON SHT. A0.09
160'-6 5/8" FROM TO
PER SURVEY ALLEY
LF
(E)
(E) CURB SIDEWALK
A
ALLEY
A
PER SURVEY
LF
E
(E) POWER
(E) PALM TREE
HORIZONTAL CONTROL:
A POLE
VERTICAL CONTROL:
A LF
G BACKLIT SIGN. CONNECT
SHEET TITLE:
TO CONDUIT @ SITE WALL.
ADDRESS:
TO
PROJECT:
G G G
BY:
DATE:
CIP NO.
NO LIGHT POLES ALLOWED WITHIN FIRE
F LANE(SHADED AREA). SEE A0.41 FOR
DIMENSIONS. MIN HEIGHT CLR. 13'-6".
E
F.O.
(E) PALM TREE
I.1 BLDG.
(E) BUILDING
(E) STREET LIGHT E E E E E E E E E E
E
F.O.
(E) TREE BLDG.
I.1
REVISIONS:
INDEX NO.
ADJ.
BLDG.
BLDG.
(E) BIKE BAR PROPERTY
F.O.
F.O.
NO.
D 0.9 17.1
CITY ENGINEER
DATE:
NOTES:
1. SEE ELEC. DWGS AND SHEET A7.00 FOR SITE LIGHTING FIXTURE SCHEDULE.
2. FOR FIXTURES NOTED LF (SHOWN IN RED FOR CLARITY) SEE AUDIOVISUAL/ SPECIALTY SCHEDULE ON A7.00A.
C 01
SITE LIGHTING PLAN
DESIGN GROUP
N
REF: A1.00, A7.00, A7.00A SCALE: 1/16" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A1.01
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A101_24X36.DWG 12/3/2021 9:12 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17.1 ENGINEERING
BLDG.
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
K
265'-0 3/8"
14'-4 7/8" 239'-10" FROM F.O. BLDG TO F.O. BLDG 10'-9 1/2"
33.04 8'-4 7/8" 6'-0" 14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2"
(N) @ (N) 6" 6"
LOCATION 01
03 GIRL'S 01 04 SHARED SHARED
01 02 01 REF. ROOM BATH. 1 01
A3.00 ROOM A2.01 A4.30 A3.00 SIM. BATH. 2 01
01
2"
A3.00 A3.00 A4.20 112 115 A4.40 118
111 A4.40
2"
A4.10
F.O. F.O.
A CMU CMU A
J JANITOR VESTIBULE 109.1
3.03 105 108 ICE
(E) ASPHALT ROOM ELEC.-MECH.
112.2
32.01 ROOM
115.2
118.2
ALLEY
16'-9"
109 LOCKER LOCKER LOCKER LOCKER
110
18'-1"
18'-1"
108.1
111.2 ROOM A ROOM B ROOM C ROOM D
111.1
101.4
45'-5" 114 116 117 119
10/31/2023
105.1 108.2
01 115.1 115.3 118.1 118.3 01
A3.01 A3.01
106.1
107.1
110.1 112.1
F.O.CMU 32.10 F.O.CMU
114.1
116.1
119.1
117.1
B BEARING BEARING B
WALL WALL
9'-9 1/2"
9'-9 1/2"
02 02
I A3.01 12.02 12.04
A3.01
120.4
120.5
120.3
12.04
12.04
MEN'S
C.O. RESTROOM C.O.
C
4'-3 1/2"CLR.
4'-0" MIN.
4'-4"CLR.
4'-0" MIN.
WOMEN'S
RESTROOM
107
ALLEY
19'-0"
19'-0"
32.02 BREAK 104.1 12.02
ROOM
104 101.6
16'-0"
FLOOR PLAN
CIVIL 02
OFFICE A2.00
102
HORIZONTAL CONTROL:
C.O. C.O.
VERTICAL CONTROL:
E I BEAM 200'-0" CLR. ICE SURFACE I BEAM E
G
9'-4 1/2"
9'-4 1/2"
85'-0"CLR. ICE SURFACE
(E) 33.04 2'-11 1/2"
SHEET TITLE:
ADDRESS:
PROJECT:
C.O. FDC C.O.
I BEAM I BEAM F
01 01
A3.02 A3.02
16'-0"
BY:
ENTRY &
101.A
101.1
101.B
SEE A1.00
SHOP
120.2
101
DATE:
CIP NO.
01
F C.O. A2.00 C.O.
G I BEAM I BEAM G
100.1
5.05
19'-0"
19'-0"
32.02 ICE RESURFACER 13.01
ROOM
0.1
100.2
100 12
3.05
C.O.
OVERHANG H
E I BEAM
11'-4"
11'-4"
CLR.
TURNAROUND
6'-0"
100.3
FOR FIRE ENGINE.
6"
6"
REVISIONS:
SEE A0.41
C.O. C.O.
I I
101.3
I BEAM I BEAM
10'-1 1/4"CLR.
(E) ASPHALT
INDEX NO.
10'-0" MIN.
ALLEY 32.01 12.02 12.02
10'-9 1/4"
5.05
10'-9 1/4"
8.01 12.03 FOR TEAM BENCHES DETAILS 12.03
101.5 CONTRACTOR SHALL MAINTAIN A STRAIGHT
F.O. 02 F.O.
NO.
I.1 3.05 AND TRUE VERTICAL PLUMB. WALL @ GRID I.1 SEE "R" SERIES DRAWINGS. 13.01 3.05 I.1
BLDG. A2.01 BLDG.
4.02
D
4.02
CITY ENGINEER
DATE:
01 10'-1" CLR.
A4.00 PED. 03 04 10'-0" MIN.
WARNING
01 02
A3.00 A3.00
SIGN A3.00 A3.00 6"
6"
10'-9"
14'-5 3/8" 14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2"
BLDG.
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C
0.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17.1
DESIGN GROUP
01
ICE RINK FLOOR PLAN N
REF: A0.30, A0.50, A1.00, A1.10A, A1.11, A1.12 SCALE: 3/32" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A1.10
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A110_24X36.DWG 12/3/2021 9:12 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17.1 ENGINEERING
BLDG.
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
K
265'-0 3/8"
14'-4 7/8" 239'-10" FROM F.O. BLDG TO F.O. BLDG 10'-9 1/2"
14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2"
6" 6"
SEE 01/ A4.20 FOR ALL
03 01 04
01 02 SLAB/ FF ELEVATIONS IN ICE 01 01 01
A3.00 TYP. @ ALL 4 TYP. @ ALL 4 A2.01 A3.00 SIM.
01 EQUIPMENT ROOM A4.20 A4.40
2"
A3.00 A3.00 3.07 CORNERS CORNERS A4.40
2"
8"
F.O. F.O.
A A
MAX
MAX
CMU CMU
J
2%
2%
10'-0"
739.39 F.F
MAX
2%
18'-1"
18'-1"
17'-5"
10/31/2023
MAX
2%
01 01
7'-5"
MAX
MAX
A3.01 A3.01
2%
2%
F.O.CMU F.O.CMU
B BEARING BEARING B
WALL 739.37 T.O.DRAIN WALL
9'-9 1/2"
9'-9 1/2"
02 739.43 02
7'-8"
739.43 739.37 T.O.DRAIN
I A3.01 739.40 F.F A3.01
R2
MAX MAX 739.40 F.F
8'-
2% 2%
01
C.O. C.O.
C
/2"
19'-0"
H
C.O. C.O.
16'-0"
02
SLAB PLAN
A2.00
HORIZONTAL CONTROL:
C.O. C.O.
VERTICAL CONTROL:
E E
9'-4 1/2"
7 1/4"
SHEET TITLE:
ADDRESS:
PROJECT:
ICE ARENA
F.O.CURB
C.O. C.O.
I BEAM I BEAM F
F.O.CURB
01 01
1'-0"
A3.02 A3.02
16'-0"
BY:
15'-0"
739.43
DATE:
CIP NO.
01
F C.O. A2.00 C.O.
G I BEAM I BEAM G
15'-8 3/8"
19'-0"
19'-0"
1'-7 1/4"
F.O.CURB R2
MAX 2% 8'
-0
F.O.CURB 1/
C.O. 2"
CONC. CURB AT THE H
E I BEAM
1'-8 3/8"
GATEWAY AS
"
1/2
INDICATED.
11'-10"
11'-4"
11'-4"
8'-0
CONC. PONY
8'-3"
R2
6"
F.O.CURTAINWALL
WALL @ SNOW
6"
REVISIONS:
C.O. MELT PIT C.O.
I I BEAM I BEAM I
INDEX NO.
F.O.CURB
10'-9 1/4"
10'-9 1/4"
12" CONC. CURB AT THE
F.O. MEMBRANE AS INDICATED. 02 F.O.
NO.
I.1 BLDG. BLDG.
I.1
A2.01
30'-3 1/2" 5'-0"
D 3'-11"
3'-11 1/2"
CITY ENGINEER
DATE:
01 2'-0"
A4.00 03 04
01 02
A3.00 A3.00
A3.00 A3.00 6"
6"
10'-9"
14'-5 3/8" 14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2"
BLDG.
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C
0.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17.1
DESIGN GROUP
NOTE: 01 N
1. OUTLINE OF SLAB IS MARKED IN RED ON THIS PLAN FOR CLARITY
ICE RINK SLAB PLAN
REF: A1.10, A1.11, ENLARGED PLANS, SECTIONS SCALE: 3/32" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A1.10A
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A110A_24X36.DWG 12/3/2021 9:12 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17.1 ENGINEERING
BLDG.
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
K
265'-0 3/8"
14'-4 7/8" 239'-10" FROM F.O. BLDG TO F.O. BLDG 10'-9 1/2"
14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2"
6" 6"
01 SEE A1.10A & A4.40
ICE 03 SEE A1.10A & A4.30 GIRL'S LOCKER 04 SHARED LOCKER LOCKER LOCKER
01 02 SEE A1.10A & ELECTRICAL REF. ROOM A ROOM B ROOM C FOR SLOPES IN SHARED ROOM D
ROOM FOR SLOPES IN ROOM A2.01 BATH. 1 BATH. 2
A4.20 FOR A3.00 ROOM ROOM 114 A3.00 116 117 SHARED BATHS 119
2"
A3.00 A3.00 109 GIRL'S & REFEREE'S 112 115 118
SLOPES IN ICE 110 111
2"
ROOM RESTROOMS
F.O. F.O.
A CMU CMU A
J VESTIBULE
108
JANITOR MEN'S WOMAN'S
105 RESTROOM RESTROOM
106
18'-1"
18'-1"
107
10/31/2023
01 01
A3.01 A3.01
F.O.CMU 04 F.O.CMU
B BEARING A7.01 BEARING B
WALL WALL
9'-9 1/2"
9'-9 1/2"
02 02
I A3.01 A3.01
19'-0"
SKATE
STORAGE
16'-0"
02
OFFICE A2.00
102
HORIZONTAL CONTROL:
C.O. C.O.
VERTICAL CONTROL:
E I BEAM I BEAM E
G
9'-4 1/2"
9'-4 1/2"
SHEET TITLE:
ADDRESS:
PROJECT:
C.O. C.O.
I BEAM I BEAM F
01 01
A3.02 A3.02
16'-0"
BY:
DATE:
CIP NO.
TYP.@ 04
01
TRANSITION A7.01
F C.O. A2.00 C.O.
G I BEAM I BEAM G
ENTRY &
SHOP
101
19'-0"
19'-0"
BUILT-UP RAMP & PLATFORM ON TOP OF CONC. SLAB @ TEAMS' BOXES. SEE 03/ A0.50 & R- DRAWINGS.
C.O.
H
E I BEAM
ICE RESURFACER
11'-4"
11'-4"
ROOM
100
6"
6"
REVISIONS:
SEE A1.10A &
C.O. C.O.
I I BEAM
A4.00 FOR
I BEAM I
SLOPES IN ICE
INDEX NO.
RESURFACER
10'-9 1/4"
10'-9 1/4"
F.O. ROOM 02 F.O.
NO.
I.1 BLDG. BLDG.
I.1
A2.01
CITY ENGINEER
DATE:
03 04
01 02
A3.00 A3.00
A3.00 A3.00 6"
6"
10'-9"
14'-5 3/8" 14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2"
BLDG.
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C
0.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17.1
DESIGN GROUP
FINISH LEGEND (SEE FIN. SCHEDULE ON SHT. A7.00)
01
RUBBER FLOORING 9.03
FLOOR FINISH PLAN N
REF: A1.10, A1.10A, A7.00 SCALE: 3/32" = 1'-0"
SEALED CONCRETE 3.01
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A1.11
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A111_24X36.DWG 12/3/2021 9:13 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
10/31/2023
I
ROOF 23.07
ACCESS
BUREAU OF ENGINEERING
23.07
9.01
26.03
BREAK ROOM
10.10
OPEN TO MEMBRANE
STRUCTURE ABOVE TYP. O/ ICE RINK
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G
SHEET TITLE:
ADDRESS:
PROJECT:
ENTRY &
BY:
101
DATE:
CIP NO.
F 13.01
ICE RESURFACER
ROOM
100
OPEN TO MEMBRANE
E STRUCTURE ABOVE
REVISIONS:
INDEX NO.
NO.
D
CITY ENGINEER
DATE:
01
A4.01
DESIGN GROUP
EXPOSED MTL. DECK (PAINTED) 5.06
01
GYP. BRD. CLNG. 9.01
REFLECTED CEILING PLAN N
REF: A1.10 SCALE: 3/32" = 1'-0"
NETTING 10.10 PER THE OFFICE OF THE FIRE STATE MARSHALL,THE CALIFORNIA TITLE19 REGULATIONS ALLOWS THE MANUFACTURER OR FABRICATOR TO MEET THE FIRE RESISTANCE REQUIREMENTS BY
HAVING THE NETTING TREATED BY A CALIFORNIA LICENSED GENERAL APPLICATOR. SEE ALSO MODIFICATION, SHEET A0.36 AND A7.00A
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A1.12
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A112_24X36.DWG 12/3/2021 9:13 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
BLDG.
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
K
265'-0 3/8"
14'-4 7/8" 239'-10" FROM F.O. BLDG TO F.O. BLDG 10'-9 1/2"
14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2"
6" 6"
03 01 04
01 02 A2.01
A3.00 A3.00
2"
A3.00 A3.00
2"
F.O. F.O.
A CMU CMU A
J
D
18'-1"
18'-1"
D D
10/31/2023
01 01
A3.01 A3.01
F.O.CMU F.O.CMU
B BEARING BEARING B
LB MLB LB MLB LB
WALL TV TV WALL
9'-9 1/2"
9'-9 1/2"
02 02
LW
ALLEY
19'-0"
19'-0"
LB
16'-0"
02
S1 A2.00
HORIZONTAL CONTROL:
C.O. C.O.
VERTICAL CONTROL:
E I BEAM I BEAM E
S1
G
9'-4 1/2"
9'-4 1/2"
SHEET TITLE:
LB A1 A1 A1 A1 A1 MH A1 A1 A1 A1
ADDRESS:
PROJECT:
C.O. LC C.O.
I BEAM I BEAM F
LC
01 01
A3.02 S A3.02
16'-0"
BY:
S1
F
A2 A2
DATE:
CIP NO.
01 S1
F C.O. A2.00 MH C.O.
G I BEAM I BEAM G
F MH2 MH2
LB TV
MH MH
A1 A1 A1 A1 A1 A1 A1 A1 A1
B B
19'-0"
19'-0"
F
S
LC LW
C.O.
E I BEAM
LB H
LW LW
A2
11'-4"
11'-4"
B B
MLB
6"
LB MLB
6"
REVISIONS:
LB LB
C.O. C.O.
I I BEAM I BEAM I
INDEX NO.
10'-9 1/4"
10'-9 1/4"
F.O. 02 F.O.
NO.
I.1 BLDG. BLDG.
I.1
A2.01
CITY ENGINEER
DATE:
03 04
01 02
A3.00 A3.00
A3.00 A3.00 6"
6"
10'-9"
14'-5 3/8" 14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2"
BLDG.
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
NOTES:
1) SEE A7.00A FOR AUDIOVISUAL/SPECIALTY LEGEND. S&C
C FIXTURES ARE SHOWN HERE FOR REFERENCE/ PURPOSE
OF COORDINATION. 0.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17.1
DESIGN GROUP
2) ALL ITEMS SHOWN IN REFLECTED CEILING PLAN ARE
WALL MOUNTED OR SUSPENDED UNLESS NOTED
OTHERWISE. CONTRACTOR TO VERIFY QUANTITY, FINAL
01
LOCATION & HEIGHT WITH OWNER & ARCHITECT.
3) AV SPECIALTY EQUIPMENT IS SHOWN IN RED FOR
AUDIOVISUAL/ SPECIALTY LIGHTING RCP N
CLARITY. REF: -- SCALE: 3/32" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A1.13
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A113_24X36.DWG 12/3/2021 9:14 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17.1 ENGINEERING
BLDG.
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
K
265'-0 3/8"
14'-4 7/8" 239'-10" FROM F.O. BLDG TO F.O. BLDG 10'-9 1/2"
14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2"
6" 48'-9" 6"
32'-10" 48'-9" 01 48'-9" 24'-1"
03 04
01 02 A2.01
A3.00 CHAIN LINK EQUIPMENT FENCE, A3.00
2"
A3.00 A3.00 04
7.05 10'-0" HIGH. 4'-0"
2"
A8.20
F.O. F.O.
A CMU CMU A
J
4'-0"
PERFORATED CORRUGATED
3/8"/ FT
MTL. EQUIPMENT SCREEN, 10'-0" 3/8"/ FT 3/8"/ FT 3/8"/ FT 3/8"/ FT 3/8"/ FT
HIGH.
01 MIN.SLOPE
MIN.SLOPE MIN. SLOPE 3/8"/ FT MIN. SLOPE MIN.SLOPE MIN. SLOPE
A4.50 3/8"/ FT
MIN.SLOPE
8'-0"
MIN. SLOPE
18'-1"
18'-1"
7.02
MIN.SLOPE
7.02
MIN.SLOPE
MIN.SLOPE
MIN.SLOPE
TYP.
3/8"/ FT
10/31/2023
3/8"/ FT
3/8"/ FT
3/8"/ FT
7.02
01 01
4'-0"
A3.01 A3.01
F.O.CMU F.O.CMU
B BEARING BEARING B
WALL 80'-0" WALL
9'-9 1/2"
9'-9 1/2"
02 02
23.01
I A3.01 A3.01
ROOF VENT TYP. 8.11 DEHUMIDIFIER COOLING TOWER 8'-0" x 80'-0" =640 SF > 600 SF (15% X 4,000 SF)
C.O. SEE MECH. DWGS (NIC) (NIC) 600 SF HATCHED AREA DESIGNATED FOR SOLAR. C.O.
C
19'-0"
FROM ENERGY CODE SECTION 110.10(B) THROUGH 110.10(C)
SHALL BE PROVIDED TO THE OCCUPANT. THIS INFORMATION
PERTAINS TO SOLAR ZONE AREA.
16'-0"
5.05
ROOF PLAN
02
A2.00
SLOPE
HORIZONTAL CONTROL:
C.O. C.O.
VERTICAL CONTROL:
E I BEAM I BEAM E
G
9'-4 1/2"
9'-4 1/2"
33.04
SHEET TITLE:
ADDRESS:
PROJECT:
C.O. C.O.
I BEAM I BEAM F
SLOPE
01 01
A3.02 A3.02
16'-0"
BY:
DATE:
CIP NO.
01
F C.O. A2.00 42'-6" C.O.
G I BEAM I BEAM G
SL
19'-0"
19'-0"
C.O.
E I BEAM H
11'-4"
11'-4"
09
A4.50
6"
6"
REVISIONS:
C.O. C.O.
I I BEAM I BEAM I
INDEX NO.
10'-9 1/4"
10'-9 1/4"
F.O. 02 F.O.
NO.
I.1 BLDG. BLDG.
I.1
A2.01
CITY ENGINEER
DATE:
HOOD PROJECTION 03 04
01 02
A3.00 A3.00
A3.00 A3.00 6"
6"
10'-9"
14'-5 3/8" 14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2"
BLDG.
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C
0.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17.1
DESIGN GROUP
01
ROOF PLAN N
REF: A0.30, A1.10 SCALE: 3/32" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A1.20
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A120_24X36.DWG 12/3/2021 9:14 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
I.1 I H G F E D B A
BEARING
F.O.CMU
K
WALL
130'-0 1/4"
11'-4" 19'-0" 16'-0" 9'-4 1/2" 16'-0" 19'-0" 9'-9 1/2" 18'-1" 2"
6"
Y
M BL 01 CL
AS
02 01
F G H SE S"
AS A3.02 A" A3.01 A3.01
OF RO
J 07 09 07 "A "R
O OF
AS
C.O. I BEAM
C.O. I BEAM
C.O. I BEAM
SS SEM + 42'-6"
A6.12 A4.50 A6.13 A
CL BL
Y T.O RIDGE @ MEMBRANE
& GATEWAY
13.01 10/31/2023
02 01
16'-0" 19'-0"
A2.01 A2.01
34'-3 1/2" 32.13
8.05 W/ CHAIN LINK
2'-0" 30'-3 1/2" 2'-0" 1'-6"
1'-1 1/2"
I
16'-0" 5'-0" 12'-9 1/2" +22'-0"
T.O. SCREEN EQUIPMENT
MEMBRANE
MEMBRANE
MEMBRANE
1'-2 1/2"
CUTOUT
CUTOUT
+12'-0"
+42'-6" LINE OF T.O CMU PARAPET
T.O. GATEWAY/ RIDGE 4.02
2'-0"
OF MEMBRANE
101.5 ALONG WEST P.L +8'-4 1/2"
T.O CMU WALL ON P.L
8'-0"
ELEVATIONS
12'-0"
CORRUGATED 4.02
MTL. SIDING. PTD.
02
HORIZONTAL CONTROL:
SOUTH ELEVATION
VERTICAL CONTROL:
REF: A1.10, A0.02 SCALE: 3/32" = 1'-0"
G
SHEET TITLE:
GRAPHICS
ADDRESS:
PROJECT:
ETCHED ON
GLAZING. EDGE OF
CONTRACTOR I BEAM 27'-0"
6" 1'-6"
SHALL CONFIRM T.O. MEMBRANE CUTOUT A B D E G I I.1
SIZE & LOCATION +26'-6"
W/ ARCHITECT T.O. GUTTER- ROOF 1
BEARING
BY:
WALL
DATE:
CIP NO.
5'-9"
130'-0 1/4"
F 01 119'-1" FROM F.O. BLDG TO F.O. BLDG 10'-9 1/4"
3'-0"
A6.11 +20'-9"
18'-1" 9'-9 1/2" 19'-0" 16'-0" 9'-4 1/2" 16'-0" 19'-0" 11'-4"
T.O. MEMBRANE CUTOUT
101.B
2" 6"
+20'-3"
6"
8.03
T.O. GUTTER- ROOF 2
CITY OF
1'-0"
33.04 33.04
5.05 01 02 01
(N) @ (N) (E) LOCATION
LOS ANGELES 13.01
LOCATION PER
DWP
A3.01 A3.01 A3.02 07
A2.00
+ 42'-6"
10'-3"
A6.10
01 02
ALIGN CURTAIN WALL MULLION A2.01 A2.01
REVISIONS:
8.03
+10'-0"
INDEX NO.
T.O. OPENING
NO.
+22'-0"
42'-0"
T.O.EQUIPMENT SCREEN
32.13 CITY OF
D 02
W/ PERFORATED LOS ANGELES
CITY ENGINEER
A6.10
DATE:
CORRUGATED MTL. SIDING
10'-0"
8'-0"
A6.14 T.O. CONC. CURB T.O.CONC. CURB
0'-0" -0'- 3 1/2" 0'-0"
T.O.S. (739.43') T.O GRADE (739.62') T.O.S (739.43')
101.1 100.1 109.1 101.5
C 4.02 -0'- 3 1/2"
T.O GRADE (739.14')
8.02 3.03 8.01
DESIGN GROUP
8.02 8.02 8.02
07 01
GATEWAY ELEVATION NORTH ELEVATION
REF: 01/-, A4.00, A4.50, A6.10, A6.11, A6.12, A6.13 SCALE: 1/4" = 1'-0" REF: A1.10, A0.02 SCALE: 3/32" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A2.00
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A200_24X36.DWG 2/4/2022 10:20 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
0.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17.1
BLDG.
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
K
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
265'-0 3/8"
01 02 03 04
A3.00 A3.00 A3.00
J A3.00
13.01 13.01
+42'-6" + 42'-6"
T.O. BLDG & GATEWAY T.O RIDGE @ MEMBRANE
01
ALLEY
02
A2.00
A2.00
I
8'-0"
T.O.CONC. CURB
0'-0"
T.O.S (739.43')
101.3
8.01 3.03 32.01 -1'-3 1/2"
ELEVATIONS
CORRUGATED T.O GRADE (737.87')
MTL. SIDING
ON GATEWAY 4.02
HORIZONTAL CONTROL:
02
VERTICAL CONTROL:
G WEST ELEVATION
SHEET TITLE:
REF: A1.10, A0.02 SCALE: 3/32" = 1'-0"
ADDRESS:
PROJECT:
17.1 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0.9
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
BLDG.
BLDG.
DATE:
CIP NO.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
F.O.
F.O.
F
265'-0 3/8"
239'-10" FROM F.O. BLDG TO F.O. BLDG 14'-4 7/8" 6'-0" TO F.O. GATEWAY
10'-9 1/2" 14'-0 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-9 1/2" 0"
1 0'-
6" 6" R
04 03 02 01
13.01 A3.00 33.13 13.01 A3.00 A3.00
A3.00
W/ CHAIN LINK
ON THIS SIDE
E + 42'-6" +42'-6"
T.O RIDGE @ MEMBRANE T.O. BLDG & GATEWAY
CLASS "A" ROOF ASSEMBLY
& GATEWAY
12.01
REVISIONS:
33.04
01
ALLEY
INDEX NO.
02
A2.00
A2.00
NO.
D
CITY ENGINEER
DATE:
13.01
+12'-0"
T.O CMU PARAPET
+12'-0"
+9'-7 1/2"
T.O. PARAPET @ CMU BLDG.
B.O MTL. DECK
+8'- 4 1/2"
T.O CMU WALL ON P.L
0'-4 1/2"
T.O GRADE (739.81')
C
0'-0" 101.4 108.1
DESIGN GROUP
T.O.S (739.43') 4.02 4.01 4.01 8.01 CORRUGATED 32.10
MTL. SIDING
ON GATEWAY
01
EAST ELEVATION
REF: A1.10, A0.02 SCALE: 3/32" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A2.01
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A201_24X36.DWG 12/3/2021 9:15 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
A B D E G I I.1 I.1 I H G F E D B A
K
BEARING
BEARING
F.O.CMU
F.O.CMU
WALL
WALL
130'-0 1/4" 130'-0 1/4"
119'-1" FROM F.O. BLDG TO F.O. BLDG 10'-9 1/4" 10'-9 3/8" 119'-1" FROM F.O. BLDG TO F.O. BLDG
18'-1" 9'-9 1/2" 19'-0" 16'-0" 9'-4 1/2" 16'-0" 19'-0" 11'-4" 11'-4" 19'-0" 16'-0" 9'-4 1/2" 16'-0" 19'-0" 9'-9 1/2" 18'-1" 2"
2" 6" 6"
CL
01 02 LY 01 AS 01 02 01
J EMB S"
S A"
A3.01 A3.01 AS A3.02 RO A3.02 A3.01 A3.01
OF 03 OF GATEWAY ENTRY & 03
" RO AS
SE BEYOND SHOP
S "A A3.10 MB 101 A3.10
AS LY + 42'-6" + 42'-6"
CL
T.O RIDGE @ MEMBRANE T.O RIDGE @ MEMBRANE
13.01 10/31/2023
13.01
10.10 12.05
01 02 02 01
A2.01 A2.01 A2.01 A2.01
6'-0"
12'-0"
H
B.O.BM.
8'-0"
23.08 4'-4" 0'-0" (739.43')
3'-6"
3.01
3.03 100.3
SECTIONS
101.5 3.01 04
07 3.04
A3.10
04 32.04 3.03 A7.01 32.01
02
HORIZONTAL CONTROL:
3.05 3.04
SECTION @ ICE RINK
VERTICAL CONTROL:
SECTION @ LOBBY
G REF: A1.10 SCALE: 3/32" = 1'-0"
REF: A1.10 SCALE: 3/32" = 1'-0"
SHEET TITLE:
ADDRESS:
PROJECT:
A B D E G I I.1 I.1 I H G F E D B A
BEARING
F.O.CMU
WALL
WALL
DATE:
CIP NO.
F 130'-0 1/4" 130'-0 1/4"
119'-1" FROM F.O. BLDG TO F.O. BLDG 10'-9 1/4" 10'-9 3/8" 119'-1" FROM F.O. BLDG TO F.O. BLDG
18'-1" 9'-9 1/2" 19'-0" 16'-0" 9'-4 1/2" 16'-0" 19'-0" 11'-4" 11'-4" 19'-0" 16'-0" 9'-4 1/2" 16'-0" 19'-0" 9'-9 1/2" 18'-1" 2"
2" 6" 6"
01 02 01 01 02 01
03 03
A3.01 A3.01 A3.02 GATEWAY A3.02 A3.01 A3.01
A3.10 A3.10
BEYOND
+ 42'-6" + 42'-6"
E T.O RIDGE @ MEMBRANE T.O RIDGE @ MEMBRANE
13.01
12.05 13.01
01 02 02 01
REVISIONS:
10.10
A2.01 A2.01 A2.01 A2.01
04
1'-0"
INDEX NO.
8.01
NO.
1'-0"
4.01 03
COOLING 01 04 SKATE
SHARPENING A8.02
D TOWER
NIC. A3.10 A3.13 8.03 BEYOND 103
CITY ENGINEER
01
DATE:
32.13 A3.13
REV. 01 +12'-0"
5.08 5.08 T.O CMU PARAPET
3.03 A3.12
4.02
4.02 +9'-7 1/2"
1'-0" @ RIDGE
4.01
4.01 B.O MTL. DECK
6'-0"
12'-0"
DESIGN GROUP
3.01 3.03
3.04
3.01
3.04 8.02
04
3.04 3.05 03 ICE RESURFACER
ROOM
ENTRY &
SHOP
VENDING
8.01
MEN'S
RESTROOM 32.01 01
3.05 101
A3.10 SECTION @ ICE RINK 100 MACHINE, NIC 106
SECTION @ RESTROOMS
REF: A1.10 SCALE: 3/32" = 1'-0" REF: A1.10 SCALE: 3/32" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A3.00
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A300_24X36.DWG 12/3/2021 9:15 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17.1
ENGINEERING
BLDG.
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
K
265'-0 3/8"
14'- 4 7/8"
14'-5 3/8" 239'-10" FROM F.O. BLDG TO F.O. BLDG 10'-9"
14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2"
6" 6"
01 02 03 04
A3.00 A3.00 A3.00 A3.00
J
10/31/2023
32.13
01
ALLEY
BEYOND 13.01
02
A2.00
13.01 A2.00
13.01
5.05
I TYP.
01
BUREAU OF ENGINEERING
T.O CMU PARAPET
32.10 +9'-7 1/2"
B.O MTL. DECK
32.01
07 VARIES
A8.40 T.O CMU WALL ON P.L
8'-0"
4.01 0'-0" (739.43')
SECTIONS
WOMEN'S 8.01
106 RESTROOM
4.02
107
HORIZONTAL CONTROL:
02
VERTICAL CONTROL:
G SECTION @ BLEACHERS
SHEET TITLE:
ADDRESS:
PROJECT:
REF: A1.10 SCALE: 3/32" = 1'-0"
BY:
0.9
DATE:
BLDG.
CIP NO.
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
F
265'-0 3/8"
14'-
14'-54 3/8"
7/8" 239'-10" FROM F.O. BLDG TO F.O. BLDG 10'-9"
14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2"
6" 6"
01 02 32.13 04
DEHUMIDIFIER 03
01 W/ CHAIN LINK ON
A3.00 A3.00 COOLING A3.00 A3.00
(NIC) 23.01 THESE SIDES
A3.11 TOWER (NIC)
E
32.13
+12'-0"
W/ CORRUCATED T.O CMU PARAPET
REVISIONS:
MTL. ON THIS
SIDE 5.02 SHARED
BATH. 1 SHARED
INDEX NO.
01 3.02 115 BATH. 2
REF. 07
ALLEY
4.01 118 02
A2.00 JANITOR 8.11 ROOM 5.06 A3.13
NO.
105 111 A2.00
D 32.10
VARIES
CITY ENGINEER
T.O CMU WALL ON P.L
DATE:
32.01
8'-0"
4.01 0'-0" (739.43')
T.O. CONC. SLAB
DESIGN GROUP
01
SECTION @ LOCKER ROOMS
REF: A1.10, A1.20 SCALE: 3/32" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A3.01
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A301_24X36.DWG 12/3/2021 9:15 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
10/31/2023
SECTIONS
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G 0.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 17.1
SHEET TITLE:
ADDRESS:
BLDG.
PROJECT:
BLDG.
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
265'-0 3/8"
BY:
6'-0" 14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-0 1/2"
DATE:
CIP NO.
6" 6"
F
+/-50'-0" 01 02 13.01 04
03 04
APPROX. TOP OF (N) POLE
A3.00 A3.00 A3.00 A3.00 A3.12
5.05
TYP.
+42'-6"
T.O. BLDG & GATEWAY
01
E
ALLEY
02
A2.00 13.01 A2.00
8.03
ICE
REVISIONS:
RINK
CORRUGATED MTL. 120
SIDING ON GATEWAY
INDEX NO.
23.07
4.02
4.01 +12'-0"
NO.
CEILING WITH GLASS
5.08 T.O CMU PARAPET
10.10
D 8.02
CITY ENGINEER
VARIES
DATE:
33.04
T.O CMU WALL ON P.L
32.01
8'-0"
0'-0" (739.43')
12.02 T.O. CONC. SLAB
3.01
07 VEND. MACHINE 101.4
3.03
A3.12 3.01
ENTRY & 3.04 3.05
SHOP
101
C
DESIGN GROUP
01
SECTION @ RIDGE
REF: A1.10, A1.20 SCALE: 3/32" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A3.02
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A302_24X36.DWG 12/3/2021 9:16 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
5.05 ENGINEERING
EXTERIOR
5.05
K CON'T SEALANT.
INTERIOR 1/2" FIBER 3.03
IMPREGNATED 3.05 +42'-6"
EXP. JOINT.
T.O. RIDGE @ MEMBRANE STRUCTURE
0'-6" (739.93)
3.05
6" TYP.
T.O. CONC. CURB 3.01
3.03
CONC. SLAB. @ EGRESS
6"
0'-0" (739.43) COURT.SEE CIVIL DWGS.
T.O. CONC. SLAB
VARIES
ENLARGED SECTIONS
01 02 01 02
A A3.01 B A3.01 C A A3.01 B A3.01 C H I I.1
I BEAM
BLDG.
I BEAM
I BEAM
I BEAM
CMU
CMU
CMU
CMU
F.O.
F.O.
F.O.
F.O.
F.O.
C.O.
C.O.
C.O.
C.O.
6"
HORIZONTAL CONTROL:
2" 18'-1" 9'-9 1/2" 01 2" 18'-1" 9'-9 1/2" 01
11'-4" 10'-9 1/2" TO P.L.
VERTICAL CONTROL:
A8.20 03 A8.20
G 01
A8.20 2"
A8.20
SHEET TITLE:
ADDRESS:
32.13
PROJECT:
13.01 13.01
9.03
13.01
22'-0"
T.O.EQUIP. SCREEN
10.10
BY:
COOLING
TOWER, NIC
DATE:
CIP NO.
F 01
A2.01
01 02
A2.01 A2.01
11 02 08
A8.20 A8.20 A8.20
12'-0" 7.01 12'-0" 03
T.O.PARAPET 10.10 T.O.PARAPET
6" 2'-4 1/2"
A8.01
9'-7 1/2" 23.07 9'-7 1/2" SEE MECH.
23.07
B.O. MTL. DECK SEE MECH. B.O. MTL. DECK
E 9'-1 1/2" DWGS. 9'-1 1/2"
DWGS.
4.02
B.O. BM. B.O. BM.
3.02 3.02
SEE A7.12 FOR 04 ICE
5.06 5.06 RINK
INTERIOR A8.20
REVISIONS:
6'-0"
6'-0"
ELEVATIONS. 120
7.05 5.02 6'-0" MIN.
LOCKER 4.01 4'-3 1/2" 5.02
PIPE 12.02
9'-1 1/2"
INDEX NO.
ROOM A 4'-0" MIN. CLR. @ TEAMS'
ICE 4.01 12.02
114 ROOM BOXES
SEE ICE RINK
NO.
4.01 109
9.04 12.04 DWGS.
4.01 3.07 SHEET R5.03
3'-6"
3'-6"
D 0'-3/8" (739.46')
9.02
CITY ENGINEER
RUBBER FINISH FLOOR
DATE:
9.03 9.03 9.03
0'-0" (739.43') 0'-0" (739.43')
T.O. CONC. SLAB T.O. CONC. SLAB
3.01
3.01 03
02 3.01 3.04
02 01 02 3.05
3.04 A8.10 3.04 A8.10 A8.10 A8.10
A8.10
06 01
SEE ICE RINK SEE ICE RINK
DWGS, DWGS.
A3.10 A3.12
C SHEET R5.01 SHEET R5.01
DESIGN GROUP
07 04 01
ENLARGED SECTION @ LOCKER ROOM ENLARGED SECTION @ REF. ROOM ENLARGED SECTION @ EGRESS COURT
REF: A3.10 SCALE: 1/4" = 1'-0" REF: A3.10 SCALE: 1/4" = 1'-0" REF: A3.10 SCALE: 1/4" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A3.10
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A310_24X36.DWG 12/3/2021 9:16 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
10/31/2023
I
01
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
14'-4 7/8" 14'-9 1/2" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0"
6"
ENLARGED SECTIONS
W/ CHAIN LINK ON
THESE SIDES
DEHUMIDIFIER (NIC) KICKERS, TYP.
SEE STRUCTURAL
06 DWGS. 23.01 03 SIM
SIM.
A8.20 A8.20
32.13
HORIZONTAL CONTROL:
W/
VERTICAL CONTROL:
PERFORATED
CORRUGATED
G MTL. ON THIS
SHEET TITLE:
SIDE
ADDRESS:
PROJECT:
ALUM. ROOF
HATCH
HEAVY DUTY
BY:
LADDER.
DATE:
CIP NO.
02
F 01 11
A8.20 02
A2.00 A8.20 A8.20 12'-0"
T.O.PARAPET
9'-1 1/2"
A8.21
01 4.01 8.01
A8.40
REVISIONS:
3.07 0'-3/8" (739.46')
RUBBER FINISH FLOOR
INDEX NO.
0'-0" (739.43')
T.O. CONC. SLAB
NO.
3.01
D 06 03
CITY ENGINEER
02 01 02
DATE:
01 A6.20 A8.10
3.04 A8.10 A8.10 A8.10 A8.10
01
C ENLARGED SECTION @ MECHANICAL ROOF
DESIGN GROUP
REF: A3.01, A4.50 SCALE: 1/4" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A3.11
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\09135.0_A311_24X36.DWG 12/3/2021 9:17 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
0.9 1 2 17 17.1
BLDG.
BLDG.
I BEAM
I BEAM
I BEAM
F.O.
F.O.
6"
C.O.
C.O.
C.O.
50'-0"
T.O.POWER POLE 14'-4 7/8" 14'-9 1/2"
R10'-0" 1'-3"
J
6" 10'-9"
09
6'-0" A4.50
01
A3.00 13.01 10/31/2023
(N) CONDUCTOR (VIF).
FINISH
1'-0 1/2"
F.O.
01
42'-6" A8.20 42'-6"
T.O. BLDG. T.O. BUILDING
13.01 PROPRIETARY
I 4.8kV LINE (EXISTING). SYSTEM. FULLY WATERPROOF
TO BE REPLACED (VIF). ROOF TO WALL .
5.05 5.05
BEYOND
ENLARGED SECTIONS
ASSUMES < or = 50kV
ALLEY
27'-1" 6"
T.O.OPENING 02
HORIZONTAL CONTROL:
A2.00 VARIES
2" CAP
VERTICAL CONTROL:
T.O. CMU WALL ON P.L.
G 01
SHEET TITLE:
ADDRESS:
A2.00
PROJECT:
13.01
BEYOND PL
10.10 FULLY GROUTED 6" WIDE ANTI-GRAFFITI COATING
CMU WALL PER SPECS.
CIP NO.
8'-0"
CON'T SEALANT.
F 8.03 4.01 1/2" FIBER IMPREGNATED
EXP. JOINT.
CONC. SLAB. @
10'-1" EGRESS
COURT. SEE
CIVIL DWGS.
TEMPERED GLASS
T.O. CONC. WALKWAY
33.04 5.08 9.04
VARIES
T.O. CMU WALL ON P.L (E) ASPHALT ON
6'-0"
12'-0"
ADJACENT PROPERTY
4'-0" 8'-0" MIN. CLR.
REVISIONS:
MIN. OVERHANG BETWEEN DOORS
32.01
13.01
INDEX NO.
7'-0"
OPEN TO
8'-0"
BEYOND 06
NO.
A3.11
3'-6"
0'-0" (739.46') 0'-0" (739.46')
T.O. RUBBER FIN. FLOOR T.O. RUBBER FIN. FLOOR
D 0'-0" (739.43') 0'-0" (739.43')
CITY ENGINEER
DATE:
T.O. CONC. SLAB T.O. CONC. SLAB CONC. FOOTING. SEE
STR'AL DWGS.
01
C -
DESIGN GROUP
07 04 01
ENLARGED SECTION @ GATEWAY ENLARGED SECTION @ EGRESS COURT TYP. CMU WALL ON P.L
REF: A3.02 SCALE: 1/4" = 1'-0" REF: A3.02 SCALE: 1/4" = 1'-0" REF: 04/- SCALE: 1 1/2"=1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A3.12
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A312_24X36.DWG 12/3/2021 9:17 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
10/31/2023
8"
12'-0"
2" CAP
T.O. CMU WAL
ENLARGED SECTIONS
I.1 I B A
8'-1"
12'-0"
CONC. SLAB ON METAL
DECK
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G LOCKER
SHEET TITLE:
ROOM D EXTERIOR
ADDRESS:
119
PROJECT:
13.01
BY:
8" WIDE CMU CON'T SEALANT. 13.01
WALL
DATE:
CIP NO.
RUBBER FLOORING 1/2" FIBER IMPREGNATED
EXP. JOINT.
F ON CONC. SLAB ON
02
GRADE
CONC. SLAB @ EGRESS A8.20
CONC. FOOTING. COURT. SEE CIVIL DWGS. 08
SEE STR'AL 03 11
DWGS. A8.01 A8.20 4.02 A8.20
+0'-0" (739.43) 4.01
T.O. CONC. SLAB 7.01
12'-0" 12'-0" 3.02
VARIES T.O. CMU WALL T.O. CMU WALL
5.06
T.O. EXT. CONC. WALKWAY
9'-7 1/2"
4.02 B.O. METAL DECK
E VARIES VESTIBULE
T.O. CMU WALL ON P.L. ICE 108
RESURFACER
100 03 EXTERIOR
A8.02
REVISIONS:
EXTERIOR MEN'S
RESTROOM
106
INDEX NO.
8.02
NO.
9.02
0'-0" (739.46')
T.O. RUBBER FIN. FLOOR
D
0'-0" (739.43') 0'-0" (739.43')
CITY ENGINEER
DATE:
T.O. CONC. SLAB T.O. CONC. SLAB
3.01
01 02 3.01
A8.10 A8.10
3.04 3.04
02 02
A8.10 A8.10
C
DESIGN GROUP
07 04 01
ENLARGED SECTION @ EXTERIOR CMU WALL ENLARGED SECTION @ ICE RESURFACER ROOM ENLARGED SECTION @ VESTIBULE
REF: 01/A3.01 SCALE: 1-1/2"=1'-0" REF: 01/A3.00 SCALE: 1/4"=1'-0" REF: 01/A3.00 SCALE: 1/4"=1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A3.13
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A313_24X36.DWG 12/3/2021 9:18 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
I.1 I H G 01
F E D
A3.12
FINISH
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
F.O
C.O
C.O
C.O
C.O
C.O
C.O
K
(E) ALLEY
CROSSWALK WARNING
(E) ALLEY
33.04 32.08
SIGN WITH 8' U CHANNEL 5'-9" 4'-0" 6'-3" ALONG P.L PER
SUPPORT SEE 01/ A8.34
TURNAROUND CIVIL
FOR FIRE ENGINE,
SEE A0.41
1/8"
DETECTABLE
2'-3"
32.01
32.01
WARNING SIGN 32.02
2'-3
83'-0"
10'-9 1/4" 6" 11'-4" 19'-0" 16'-0" 9'-4 1/2" 16'-0" 10'-9 1/2"
6" 2 1/2"
8'-11" 2'-6" 1'-0" 30'-3 1/2" 1'-0" 4'-3 1/4" 5'-1 1/4" 7'-5 1/2" 8'-6 1/2" 1'-4" 9'-5 1/2"
J
C.O. COL.
COL.
10'-9 1/2" 5'-8 1/2" 13'-9 1/2"
C.O.
STUD
F.O
STUD
STUD
C.O.
C.O.
DUE TO MEMBRANE'S CURVATURE
F.O.
CMU
F.O.
CMU
14'-5 3/8"
ALIGN
10/31/2023
6'-0" TO F.O. FINISH
4'-0" MIN.
02 FDC 1-HR RATED WALL
4'-0"
8.02 BETWEEN
32.04 A6.10
100.1
2'-0" MEMBRANE AND
5'-0" CLR.
6'-0"
6'-0"
MIN. CLR. RROM @ SKATE
101.1 32.10
STORAGE AND
F.O F.O
I 0.9 OFFICES 0.9
101.5
H
6"
BUREAU OF ENGINEERING
I BEAM I BEAM
8'-0" MIN.
F.O.STUD
4'-0" CLR.
1'-0 1/2"
6"
9'-0"
2'-6"
2'-6"
2'-0"
7"
2'-0"
739.43 10'-0" 8'-0"
H B
7'-0"
T.O.S. & F.F BOLLARDS 739.43 T.O.S.
G G
5'-2"
739.46 F.F
6'-0"
103.1 12.06
101.2 12.06
11'-8 3/4"
H SEE ICE RINK DWGS.
SKATE
14'-9 1/2"
14'-9 1/2"
SEE A4.10
STORAGE
739.39 9.03 9.04 103
ENLARGED PLAN
T.O.S. & F.F
12.06 SKATE SHARPENER
OFFICE
13.01 B 739.43 T.O.S.
102
& TABLE NIC
739.46 F.F
6'-
" 9.04
1/2 0"
8"
739.43 5
@ 12'-0" HT. G G
' - '-
T.O.S. & F.F 1 2 . 12 PROVIDE CAP.
4.02 N
MI TYP. IN THIS VENDING
27'-0" TO F.O CMU
C.O.STUD
HORIZONTAL CONTROL:
ICE RESURFACER 5'-
ROOM MACHINES 0"
2'-5 3/4"
VERTICAL CONTROL:
ROOM C
4'-
(NIC) LR
0"
100 . BREAK 01
G 01
30'-3 1/2"
ROOM
TR
A3.00
SHEET TITLE:
C.O A3.00 104 C.O
EN
2 2
ADDRESS:
I BEAM I BEAM
2'-0"
CH
PROJECT:
16'-0"
9.03
DR
30 X 48
AIN
1'-3"
ICE 739.43 T.O.S. F
3.05 RESURFACER 739.3 739.46 F.F 02
A
9'-10 1/2"
BY:
0" DESK/
1'- COUNTER AND 2'-6"
DATE:
9.02 9.03
CIP NO.
B
5'-0" CLR.
5'-0" CLR.
CHAIRS (NIC)
3.01 ENTRY & 1'-6" 1'-6"
F
15'-0"
15'-0"
SHOP MIN. CLR. MIN. CLR.
104.1
102.1
2% SLOPE MAX.
101
5'-0" CLR.
4'-0"MIN.
1'-6" F.O.FINISH
MIN. CLR.
100.3
HB 1'-0"
4'-0" CLR.
4'-0" CLR.
739.43 739.43
8.07 ALIGN MIN. CLR.
T.O.S. & F.F T.O.S. & F.F
5'-1 1/2"
100.2 G
1'-0"
02 MIN. CLR. 02
9.02 9.03 9.04
4'-0" CLR.
A3.00 A3.00
" IN
C.O 8'-0 DRA 5.01 C.O
1'-0
E 3 I BEAM EN
C H
I BEAM 3
2'-4 1/2"
120.2
SEE ICE RINK DWGS 9.03
REVISIONS:
101.3
6'-0
13.02
FOR DETAILS
"M
INDEX NO.
IN.
739.43
T.O.S &F.F.
NO.
GATES FOR ICE
RESURFACER ICE
D SEE ICE RINK DWGS RINK
120
01
0.1
CITY ENGINEER
FOR DETAILS
DATE:
ICE RINK GATE
A3.12
739.43 F.F
F.O. CMU
F.O. CMU
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
FINISH
C
C.O
C.O
C.O
C.O
C.O
C.O
F.O
DESIGN GROUP
I.1 I H G F E D
01 N
ENLARGED PLAN
REF: A1.10, A1.10A, A1.11, A8.34, SECTIONS SCALE: 1/4" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A4.00
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A400_24X36.DWG 12/3/2021 9:18 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
I.1 I H G F E D
FINISH
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
C.O
C.O
C.O
C.O
F.O
C.O
C.O
K
26.02 RECESSED @
GATEWAY ROOF
J
EQ. 10'-0" 10'-0" EQ.
10/31/2023
2'-0"
F.O 3'-9" 9'-0" F.O
I 0.9 BLDG. BLDG. 0.9
C.O C.O
BUREAU OF ENGINEERING
I BEAM I BEAM
3'-8"
CORRUGATED 26.03
METAL CLADDING STORAGE
WALL MOUNTED
TYP. WHERE OPEN 103
ENLARGED RCP
26.03
8'-11"
13.01
26.03
OFFICE
WALL MOUNTED 102
9'-0"
TYP. WHERE OPEN
OPEN TO TO MEMBRANE
ENTRY &
HORIZONTAL CONTROL:
MEMBRANE ABOVE SHOP OPEN TO
VERTICAL CONTROL:
STRUCTURE ABOVE 101 MEMBRANE
STRUCTURE ABOVE
G EQ. EQ.
11'-8"
SHEET TITLE:
C.O C.O
2 2
ADDRESS:
I BEAM I BEAM
PROJECT:
26.03 TYP. OPEN TO
SEE A4.11
5.05
WALL MOUNTED MEMBRANE
TYP. WHERE OPEN STRUCTURE ABOVE
26.03 SUSPENDED FROM
TO MEMBRANE ICE RESURFACER 9'-9" 26.03
BY:
100 STRUCTURE, TYP.
DATE:
CIP NO.
4'-7"
F OPEN TO
BREAK
MEMBRANE
ROOM
STRUCTURE ABOVE
6'-7"
104
STRUCTURE, TYP.
C.O C.O
E 3 I BEAM I BEAM 3
SUSPENDED FROM
MEMBRANE
RIDGE OF MEMBRANE
REVISIONS:
26.03 STRUCTURE, TYP. 26.03 SUSPENDED FROM
STRUCTURE @ 42'-6" MEMBRANE
5'-2" 28'-6" 30'-4"
STRUCTURE, TYP.
INDEX NO.
NO.
D 10.10
CITY ENGINEER
DATE:
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
FINISH
C
C.O
C.O
C.O
C.O
C.O
C.O
F.O
DESIGN GROUP
I.1 I H G F E D
01 N
ENLARGED REFLECTED CEILING PLAN
REF: A1.12, A4.00 SCALE: 1/4" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A4.01
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A401_24X36.DWG 12/3/2021 9:19 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
C B A ENGINEERING
F.O. CMU
BEARING
I BEAM
WALL
F.O.
CMU
C.O
01
K A3.01
2"
36'-1"
18'-0" 18'-1"
C.O. STUD.
F.O. CMU
6" CONC. CURB PER CIVIL
(FINISH)
F.O H 5'-4" CLR. F.O
0.9 13.01 02 04 ALIGN 9.04 0.9
BLDG. BLDG.
A3.01 A8.01
J
6"
C.O F C.O
1 I BEAM I BEAM 1
7"
F.O.STUD
739.43
T.O.S & F.F A.1
10/31/2023
9.02
2'-0"
5'-0" CLR.
5'-8"
URINAL JANITOR
105
8"
18'' MIN. 18'' MIN.
EQ EQ 22.03
SEE 01/A0.23 FOR ALL DIMENSIONS
105.1
6", TYP. 1'-3" 1'-3"
SLOPE 2% MAX.
LOCATION OF ALL FIXTURES, TYP. 7'-4" 1'-6"
A6.20
9.02
02 MIN. CLR.
3'-9"
A7.14 MEN'S F.O.CMU
RESTROOM
106
5'-0" CLR. C
11'-8 3/4"
30 X 48 LV METERING AND DISTRIBUTION
9.03
106.1
SWITCHBOARD PAD PER LADWP
5'-0'' MIN.
14'-9 1/2"
CLR.
739.32 T.O. 1'-0" BOLLARDS @ DWP EQUIPMENT.
30 X 48
ENLARGED PLAN
TYP. DOTTED CLEARANCES REPRESENTS
ACCESS.
MIN. CLR.
W/ TILE ON LANDING AT DOOR SEE 04/A0.25 FOR
5'-0"
COMPARTMENT
MIN. CLR.
MORE INFO. INTERIOR DOOR
1'-0"
BOTH SIDES.
1'-6"
LANDINGS SHALL BE LEVEL ON
EACH SIDE OF THE DOOR, TYP.
9.04
TYP. @ EXTERIOR
HORIZONTAL CONTROL:
9.06
F 9.04 9.04
1'-6"
CMU WALLS, 9'-0"
VERTICAL CONTROL:
G 01 01
B NON-ALCOVE
25'-2"
SHEET TITLE:
MIN. CLR.
A3.00 WING WALL. A3.00 C.O. STUD.
ADDRESS:
PROJECT:
2'-0"
MIN. CLR.
1'-0"
30 X 48
2'-5 3/4"
9.08 739.46 22.05
10.04
SEE A4.00
TYP.
BY:
C.O 739.46 F.F C.O
19'-6"
2 I BEAM 2
DATE:
I BEAM
5'-0"
CIP NO.
22.06 SLOPE 2%
TYP. MAX. TYP.
18'' 4'-0" CLR. 5'-0" CLR.
F TYP.
5'-4"
5'-0'' MIN. CLR. 18'' MIN. 18'' MIN. 18'' MIN. 18'' MIN. 18'' MIN. 18'' MIN. 18'' MIN. 18'' MIN. VESTIBULE 108.1
1'-6"
EQ EQ EQ EQ EQ EQ EQ EQ 108
3'-0" 1'-6"
5'-0'' MIN. CLR.
D
22.09
06 DOTTED CLEARANCES
01
MIN. CLR.
NON-ALCOVE C A REPRESENTS LANDING AT
MIN. CLR.
A8.10 A7.10
1'-6"
WOMEN'S WING WALL. DOOR SEE 04/A0.25 FOR MORE
1'-0"
RESTROOM 10.14 A.1 INFO. DOOR LANDINGS SHALL
107
B BE LEVEL EXCEPT FOR
30 X 48
A 739.32 T.O. 9.03 EXTERIOR LANDINGS,
DRAIN PROVIDE 2% MAX SLOPE. TYP.
9'-10 1/2"
9'-10 1/2"
SLOPE 2% MAX.
E D
01
B
4'-0" CLR. 5'-0" CLR.
A7.14
7'-4"
9.08
C 1'-6"MIN. 9.03
5'-0" CLR.
6"
REVISIONS:
TYP. 1'-3" 1'-3" 107.1
5'-0" CLR. 4'-0" CLR.
INDEX NO.
F 8"
NO.
2'-0"
108.2
1'-6"
B
MIN. CLR.
D
CITY ENGINEER
DATE:
F.O. CMU
(FINISH)
9.08
1'-0"
10.01 10.06 9.07 ALIGN MIN. CLR.
22.02 F 739.43 T.O.S
10.13 9.04
4'-0" CLR.
739.46 F.F
739.43 T.O.S 9.03
739.46 F.F 9.03
C
F.O. CMU
BEARING
I BEAM
WALL
DESIGN GROUP
CMU
F.O.
C.O
02
01 SEE A4.20
A3.01
C B A3.01 A 01 N
RESTROOMS & VESTIBULE ENLARGED PLAN
REF: A1.10, A1.10A, A1.11, A4.11, A7.10 SCALE: 1/2" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A4.10
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A410_24X36.DWG 12/3/2021 9:19 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
C B A ENGINEERING
F.O. CMU
BEARING
WALL
F.O.
I BEAM
CMU
C.O
K
F.O F.O
0.9 BLDG. BLDG. 0.9
J C.O C.O
1 I BEAM I BEAM 1
26.03
EQ.
TYP. JANITOR 10/31/2023
SURFACE 105
MOUNTED.
EQ.
MEN'S
RESTROOM
106
EQ.
7'-0"
26.03
ENLARGED RCP
TYP.
5'-6"
D
B
HORIZONTAL CONTROL:
8'-0" 26.03 WALL MOUNTED
VERTICAL CONTROL:
B.O.CLNG.
26.03
G TYP.
SHEET TITLE:
SURFACE
ADDRESS:
PROJECT:
MOUNTED.
SEE A4.01
5.05
9'-0"
VESTIBULE 2
DATE:
I BEAM
CIP NO.
WOMEN'S I BEAM
RESTROOM 108
5'-8"
2'-8" 107
F
7'-3"
9.04
B
5.06
TYP.
26.03
TYP.
SURFACE SURFACE MOUNTED
MOUNTED. FAN. TYP. SEE
MECH. DWGS.
E B
26.03
B B
D
TYP.
SURFACE 26.03 WALL MOUNTED
MOUNTED. 9.01
REVISIONS:
9'-7 1/2"
EQ.
B.O.DECK
INDEX NO.
8'-0"
B.O.CLNG.
NO.
D
CITY ENGINEER
DATE:
6'-0" 3'-6"
9.04
4.01
5.06
C TYP.
F.O. CMU
BEARING
I BEAM
WALL
DESIGN GROUP
CMU
F.O.
C.O
SEE A4.21
C B A 01 N
RESTROOMS & VESTIBULE ENLARGED REFLECTED CEILING PLAN
REF: A1.12 , A4.10 SCALE: 1/2" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A4.11
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A411_24X36.DWG 12/3/2021 9:19 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
02 3 4 5 6
03
A3.00
K A3.00
I BEAM
I BEAM
I BEAM
I BEAM
C.O
C.O
C.O
C.O
15'-0" TO G.L. 2 15'-0" 15'-0" 15'-0" 15'-0" TO G.L. 7
53'-4"
7'-3" 46'-1"
F.O.CMU 5'-1 3/4" 2'-1 1/4" 9'-8 3/4" 9'-0" PAD 14'-6" 9'-0" PAD 8" 3'-2 1/4"
F.O.CMU
5'-10" 9.04
9.06
2"
J
F.O. F.O
A CMU CMU
A
2'-5"
T.O.S & F.F. A
TYP. IN ICE ROOM 739.40 739.42 739.42 3.07
CONC. CURB 3.07 739.42
PER CIVIL
739.43
SLOPE 2%
MAX. TYP.
6'-7" PAD
ENLARGED PLAN
INFO. FOR EXTERIOR
18'-1"
1'-9"
SEE MECH. DWGS. FD 739.42
HORIZONTAL CONTROL:
(R SERIES) AND MECH. 739.35
VERTICAL CONTROL:
9.02 DWGS.
C.O
SEE A4.10
SEE A4.30
9.06
G LADDER
DRAIN
SHEET TITLE:
FD
2% MAX
B1
ADDRESS:
PROJECT:
4'-0" CLR.
2'-6"
2% MAX
739.42
9.03
3.07
8'-1"
BY:
01 01
A3.01 A3.01
DATE:
739.42
CIP NO.
3'-6" PAD
F
2'-10" PAD
5.05 739.43 739.43
739.43 T.O.S
ABOVE 739.43
739.46 F.F
F.O F.O
B CMU CMU
B
5.05
ABOVE 9.04 B1
E
9.03
FACE OF CMU
REVISIONS:
02
03
INDEX NO.
A3.00 12.04 30 X 48
7'-3 1/4" 5'-10" NON COMBUSTIBLE A3.00
NO.
5'-7 1/2" 9'-2" PAD 3'-11 1/4" 24'-0" PAD 3'-2 1/4"
CITY ENGINEER
DATE:
I BEAM
I BEAM
I BEAM
I BEAM
C.O
C.O
C.O
C.O
3 4 5 6
C
01
DESIGN GROUP
ICE ROOM ENLARGED PLAN
REF: A1.10, A4.21 SCALE: 1/2" = 1'-0" N
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A4.20
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A420_24X36.DWG 12/3/2021 9:20 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
3 4 5 6
K
I BEAM
I BEAM
I BEAM
I BEAM
C.O
C.O
C.O
C.O
EQ. EQ. EQ. EQ. EQ. EQ.
J
F.O. F.O
A CMU CMU
A
1'-4 1/4"
10/31/2023
26.03 26.03
TYP. TYP.
I SURFACE 5.02 SURFACE
MOUNTED. TYP. MOUNTED.
7.05 7.05
5.06
9'-1 1/2"
9'-10"
ENLARGED RCP
SPRINKLER LINE ICE
ROOM
109
HORIZONTAL CONTROL:
VERTICAL CONTROL:
5.02
G TYP.
SHEET TITLE:
ADDRESS:
PROJECT:
EQ.
8.11
26.03
TYP.
9.04
SURFACE
MOUNTED.
DATE:
26.03
CIP NO.
5.06 TYP.
F TYP. SURFACE
EQ.
MOUNTED.
1'-8"
F.O F.O
B CMU CMU
B
E 5.05 TYP.
OPENING
OPENING
REVISIONS:
INDEX NO.
EQ. EQ. 10" 3'-0"
NO.
D
CITY ENGINEER
DATE:
I BEAM
I BEAM
I BEAM
I BEAM
C.O
C.O
C.O
C.O
3 4 5 6
C
01
DESIGN GROUP
ICE ROOM ENLARGED REFLECTED CEILING PLAN
REF: A1.12, A4.20 SCALE: 1/2" = 1'-0" N
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A4.21
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A421_24X36.DWG 12/3/2021 9:20 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
7 8 9
K
I BEAM
I BEAM
I BEAM
C.O
C.O
C.O
15'-0" TO G.L. 6 15'-0" 15'-0" 15'-0" TO G.L. 10
52'-0"
25'-10" 7'-7" 8'-2" 10'-5"
2 1/2"
11'-9 1/2" 14'-0 1/2" 11 1/2" 6'-7 1/2" 3'-3" 4'-11" 2'-1" 8'-1 1/2"
F.O. CMU
OPENING
OPENING
F.O.CMU
F.O. CMU
F.O. CMU
9.06
9.04
J
2"
F.O F.O
A CMU CMU
A
1'-10"
8"
8"
10/31/2023
A
F.O. CMU
1'-5" MIN.
10.04 10" SHELF WITHIN REACH RANGE
SLOPE TO
1'-6"
MAX. TYP.
DRAIN 2%
SEE
2'-0"
22.02 C C REFEREE'S
9.07 BATHROOM
739.43 T.O.S
I B TYP. @ CMU
739.46 F.F FOR
22.06 BATHROOM 5'-4" A TYPICAL
1'-6" C MIN. 5'-0"
1'-5" MIN. 5'-3" WALLS 10.01 PER 11B-803.6 30"x48" PER 11B-903.2 NOTES/
5'-2"
5'-2"
4'-0" CLR.
06 1'-6" A 01
9.04 D B
A8.10 A7.11
MIN. CLR.
739.38
MIN. CLR.
10.09
1'-6"
DRAIN 2%
1'-0"
4'-1 1/2"
ELEC.-MECH. A7.11 12.03 1'-0" C
8'-8"
5'-0" CLR.
ROOM MAX. TYP. MIN. CLR.
739.36 9.03
110
SEE 01/A0.23 FOR ALL DIMENSIONS AND T.O.DRAIN 22.09 C 10"
SEE ELEC. /MECH DWGS. F.O. CMU
B CLEARANCES NOT NOTED ON THIS PLAN.
112.2
ROOM
02 111 1'-6" C
9.03 LOCKER
SEE A4.20
ENLARGED PLAN
D B MIN. CLR. ROOM A
3'-6"
A7.11
111.1
739.43
18'-1"
18'-1"
1'-6" 114
T.O.S & F.F 10.06 TYP.
111.2
5'-0" CLR.
MIN. CLR. 01
2'-0"
10.13 TYP. C 10"
D B
A7.11
1'-8"
F.O. CMU
HORIZONTAL CONTROL:
7"
VERTICAL CONTROL:
10" SHELF WITHIN REACH RANGE
1'-6"
1'-6"
1'-0" B
G B MIN. CLR. 10.01 PER 11B-803.6 GIRL'S
B
SHEET TITLE:
06 ROOM
112
4'-0" CLR.
ADDRESS:
PROJECT:
A6.20
MIN. CLR.
9.04 9.04
EQ. EQ.
MIN. CLR.
22.05
1'-6"
9.02 9.03 739.43 T.O.S
NON-ALCOVE
1'-0"
1'-6" 1'-6" 739.46 F.F
WING WALLS /
739.46 9.04
739.43 GRAB BARSS
6'-11"
BY:
10.09
7'-7"
01 9.02 01
A3.01 12.03 A3.01
DATE:
CIP NO.
4'-0" CLR. 5'-0" CLR. A 4'-0" CLR. 5'-0" CLR. 30"x48" PER 11B-903.2
F 30"X48"
02
D B
A7.12 112.1
110.1 9.03
F.O. CMU
8"
F.O F.O
B CMU CMU
B
4.01
4.01 5.05 9.04
B 9.04 ABOVE ABOVE B
E DOTTED CLEARANCES REPRESENTS
LANDING AT DOOR SEE 04/A0.25 FOR
5'-0" CLR.
MORE INFO. INTERIOR DOOR LANDINGS
739.43 T.O.S SHALL BE LEVEL ON EACH SIDE OF THE
739.46 F.F DOOR, TYP.
REVISIONS:
12.04 NON COMBUSTIBLE,
INDEX NO.
30"X48" TYP.
NO.
D
CITY ENGINEER
DATE:
I BEAM
I BEAM
I BEAM
C.O
C.O
C.O
7 8 9
C
01
DESIGN GROUP
ELEC., REF & GIRL'S ROOM ENLARGED PLAN
REF: A1.10, A1.10A, A4.31, A7.11, A7.12 SCALE: 1/2" = 1'-0" N
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A4.30
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A430_24X36.DWG 12/3/2021 9:21 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
7 8 9
K
I BEAM
I BEAM
I BEAM
C.O
C.O
C.O
EQ. EQ. EQ. 8'-2" EQ. EQ. EQ. EQ. EQ. EQ. EQ.
J
F.O F.O
A CMU CMU
A
10/31/2023
26.03
4'-2"
SURFACE MOUNTED
EQ.
TYP.
3'-0"
3'-0"
I 26.03 26.03 26.03
SURFACE MOUNTED SURFACE MOUNTED SURFACE MOUNTED 7.05
TYP. TYP. TYP.
EQ.
26.03 FAN. TYP. SEE
26.03
SURFACE MOUNTED MECH. DWGS.
5.06 TYP. TYP.
TYP.
REF.
ENLARGED RCP
8'-6"
9'-7 1/2"
B.O. DECK
5'-2 1/2"
ELEC.-MECH. 26.03
ROOM
5.02 110 SURFACE MOUNTED
HORIZONTAL CONTROL:
TYP.
VERTICAL CONTROL:
TYP.
G
SHEET TITLE:
GIRLS
ADDRESS:
PROJECT:
9'-1 1/2" ROOM
EQ.
B.O. BEAM 112
26.03
SURFACE MOUNTED
TYP.
CIP NO.
23.07
F SEE MECH. DWGS.
EQ.
5.02
5.05 ABOVE
F.O F.O
B CMU CMU
B
4.01
5.05 TYP.
E EQ. 7'-7" EQ. EQ. EQ.
REVISIONS:
INDEX NO.
NO.
D
CITY ENGINEER
DATE:
I BEAM
I BEAM
I BEAM
C.O
C.O
C.O
7 8 9
C
01
DESIGN GROUP
ELEC, REF & GIRLS ROOM ENLARGED REFLECTED CEILING PLAN
REF: A1.12 , A4.30 SCALE: 1/2" = 1'-0" N
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A4.31
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A431_24X36.DWG 12/3/2021 9:21 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
14 04
15 16 17 17.1
K A3.00
BLDNG.
I BEAM
I BEAM
I BEAM
I BEAM
F.O
C.O
C.O
C.O
C.O
15'-0" TO G.L. 13 15'-0" 15'-0" 14'-0 1/2"
10'-9 1/2" TO P.L.
54'-8"
20'-4" 14'-0" 20'-4"
3 1/2" 2"
10'-1 1/2" 10'-2 1/2" 4'-6" 3'-0 1/2" 6'-2" 5'-9 1/2" 13'-10 1/2" 6"
OPENING
F.O. CMU
F.O. CMU
F.O. CMU
F.O. CMU
F.O. CMU
F.O. CMU
9.06 3'-0"
A A A D
CLR.
CLR.
8"
8"
2"
J 9.04
F.O F.O
A CMU CMU A
1'-10"
8"
10/31/2023
F.O. CMU
TYP. @ CMU
1'-6"
9.07
C C
SLOPE TO
MAX. TYP.
DRAIN 2%
BATHROOM
A1 WALLS
I B 22.09
01
D B 22.02
5'-0"
A7.13
4'-0" CLR.
5'-0"
TYP. 9.04
BUREAU OF ENGINEERING
HATCHED AREA REPRESENTS PORTION OF EQUIP. A TYP. @
10.06 SHELVING WITHIN REACH RANGE @ 40" MIN.-48" MAX LOCKER 10.09
10.04 TYP. 739.44 C1
T.O.DRAIN 10.13 01 ROOMS
30"X48"
D B REV. 12.03
1'-0" A7.12
C MIN. CLR. 9.03 C
9'-0"
C F.O. CMU
SEE NOTES ON LOCKER
2'-6"
6" 6" 9.03
LOCKER 9.03
ROOM C 1'-6" 5'-0" MIN. CLR.
ENLARGED PLAN
118.2
LOCKER
3'-0" CLR.
LOCKER 117 2'-8" 4" MIN. CLR. 10.07
4'-0"
ROOM D
18'-1"
ROOM B
117 3.03 119
A
5'-0" CLR.
C
9.02
SEE A4.30- SIM
HORIZONTAL CONTROL:
F.O. CMU
VERTICAL CONTROL:
1'-6" CLR.
1'-6" CLR.
C 30"x48" PER 11B-903.2 30"x48" PER 11B-903.2
MIN. CLR.
MIN. CLR.
G SHARED 04
1'-6"
BATH. 2 A.1
1'-0"
1'-0"
SHEET TITLE:
C 118 A7.01
ADDRESS:
PROJECT:
3'-0" MIN. CLR.
4'-0" CLR. OPENING
4'-0" CLR. 22.09
5'-0" CLR. 06
1'-8" BENCH
30"x48" PER 11B-903.2 A8.10 5'-0" CLR.
30"x48" PER 11B-903.2
BY:
01 01 EQ. EQ. 01
7'-3"
D B
A3.01 A7.13
10"
A3.01
DATE:
CIP NO.
5'-1"
4'-0" CLR.
4'-0" CLR.
MAX.
118.1 118.3
2%
F 10.01 PER 11B-803.6 1'-0"
C
10.01 PER 11B-803.6
MIN. CLR.
1'-10 1/2"
1'-0"
MIN. CLR.
F.O. CMU
8"
F.O F.O
B CMU 1'-6" CMU B
1'-6"
117.1
119.1
MIN. CLR. MIN. CLR.
5.05 10.13
ABOVE B
E 10.06
SEE 01/A1.0
22.02 04
5'-0" CLR.
5'-0" CLR.
10.01 A8.01
H
REVISIONS:
9.04
12.04
INDEX NO.
9.03
NO.
04
D A3.00 739.43 T.O.S
739.46 F.F
CITY ENGINEER
DATE:
DOTTED CLEARANCES REPRESENTS
I BEAM
I BEAM
I BEAM
I BEAM
BLDG.
LANDING AT DOOR SEE 04/A0.25 FOR
C.O
C.O
C.O
C.O
F.O
MORE INFO.
14 15 16 17 17.1
C
01
DESIGN GROUP
LOCKER ROOM & SHARED BATHROOM ENLARGED PLAN
REF: A1.10 , A1.10A, A4.41, A7.12, A7.13 SCALE: 1/2" = 1'-0" N
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A4.40
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A440_24X36.DWG 12/3/2021 9:22 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
14 15 16 17 17.1
K
BLDNG.
I BEAM
I BEAM
I BEAM
I BEAM
C.O
C.O
C.O
C.O
F.O
EQ. EQ. EQ. EQ. 6'-0" 1'-6" 1'-6"
J
F.O F.O
A CMU CMU A
10/31/2023
EQ.
7.05 B.O. DECK
3'-0"
3'-0"
TYP.
I
9.04
9'-1 1/2"
EQ.
MECH. DWGS. 26.03 26.03
SURFACE 5.06 TYP. TYP.
MOUNTED. TYP.
5.06 SURFACE 9.04 SURFACE
MOUNTED. MOUNTED.
TYP.
7'-10"
ENLARGED RCP
LOCKER LOCKER
SPRINKLER LINE ROOM C ROOM D
117 119
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G
SHEET TITLE:
ADDRESS:
PROJECT:
26.03
26.03 26.03 TYP.
SHARED
TYP. TYP. SURFACE
BY:
SURFACE SURFACE MOUNTED. 118
MOUNTED. MOUNTED.
DATE:
CIP NO.
5'-0"
23.07
F.O F.O
B CMU CMU B
5.05 ABOVE
TYP.
E
5.05 TYP.
REVISIONS:
INDEX NO.
NO.
D
CITY ENGINEER
DATE:
I BEAM
I BEAM
I BEAM
I BEAM
BLDG.
C.O
C.O
C.O
C.O
F.O
14 15 16 17 17.1
C
01
DESIGN GROUP
LOCKER ROOM & SHARED BATHROOM ENLARGED REFLECTED CEILING PLAN
REF: A1.12 , A4.40 SCALE: 1/2" = 1'-0" N
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A4.41
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A441_24X36.DWG 12/3/2021 9:22 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
3 4 5 6 7
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
K
C.O.
C.O.
C.O.
C.O.
C.O.
15'-0" 15'-0" 15'-0" 15'-0"
0.9 1 PARAPET WALL ROOF KICKERS, TYP.
W/10'-0" 32.13 ROOF VENT, SEE STRUCTURAL DWGS.
03 07
I BEAM
BETWEEN G.L 3&8. SEE
BLDG.
ROOF KICKERS, TYP. TYP. SEE
A8.20 A8.21
C.O.
F.O.
SECTIONS & ELEVATIONS SEE STRUCTURAL DWGS. MECH. DWGS.
F.O.
A CMU A
6'-0" 6" 32.13
TO FINISH
SLOPE
STRUCTURE
42'-6"
08
06 SIM.
SLOPE
A8.21 08
A6.11 06 10/31/2023
32.14 DEHUMIDIFIER A8.21
A8.20 23.01
(NIC) COOLING
18'-1"
TOWER (NIC)
TO FINISH
9 1/2"
I F
C.O.
F PIPES 5'-0" CLR.
I BEAM @ CONDENSING
8.11 UNIT. KICKERS &
07
A3.12 FLAT MTL. F.O.
FASCIA SHEET MTL. GUTTER. B CMU
B
SLOPE
5.05 TYP. 08
01 4.01 A8.20 13.01
BELOW
21'-4 1/2"
A6.12
ENLARGED PLAN
13.01
3 4 5 6 7
HORIZONTAL CONTROL:
VERTICAL CONTROL:
I BEAM
I BEAM
I BEAM
I BEAM
I BEAM
42'-6"
34'-3 1/2"
C.O.
C.O.
C.O.
C.O.
C.O.
G G
C.O. T.O. GATEWAY
G
SHEET TITLE:
I BEAM 15'-0" 15'-0" 15'-0" 15'-0"
ADDRESS:
PROJECT:
07 5'-10" 32'-10" 24'-4" 4'-10 3/4"
SLOPE
TO COOLING
TO ROOF BREAK 1'-8 1/2"
C.O. DRAIN
C.O. DRAIN
W/10'-0" 32.13
TO ROOF
BY:
BETWEEN G.L 3&8. SEE
TOWER
7.05 TYP.
RIDGE
SECTIONS & ELEVATIONS
DATE:
CIP NO.
F.O.
A A
SLOPE
F CMU
01 32.13
20'-3"
3'-10"
04
19'-0"
5'-5"
5'-9"
3/8"/ FT 3/8"/ FT
12'-11"
05 TO COOLING TOWER
5"
SIM.
MECH. PAD A8.21 MECH. PAD
5'-0" PAD
6'-1" PAD
7.02 COOLING TOWER 7.02
10 ABOVE (NIC)
E
5'-8"
10
18'-1"
SL. SL.
A8.20
MIN.SLOPE
TYP. @ 4 A8.20 SL. SL.
TO FINISH 5.03
12'-9"
3/8"/ FT
CORNERS OF
COOLING
1'-6"
REVISIONS:
C.O.
H H
2'-6"
CLR. 1'-2"
OPENING
INDEX NO.
1'-2"
06
OPENING
7.02
2'-6"
NO.
2'-0"
A6.11 TYP.
OPENING
10"
2'-3"
1'-6"
CITY ENGINEER
DATE:
0.9 1 F.O.
B CMU
B
CRICKET
MEMBRANE
ROOF VENT,
SLOPE
5.05 TYP.
2'-1 1/4" 1'-6" 3'-0" TYP. SEE
13.01
MECH. DWGS.
C 3 4 5 6 7
DESIGN GROUP
09 01
GATEWAY ROOF ENLARGED PLAN MECHANICAL ROOF DRAINAGE & EQUIPMENT ENLARGED PLAN
REF: A1.20 SCALE: 1/4" = 1'-0"
N REF: A1.20, 01/ A3.01, 03/A3.00, 04&07/A3.10, A0.36 SCALE: 1/4" = 1'-0"
N
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A4.50
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A450_24X36.DWG 12/3/2021 9:22 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
'd' CLR. TO
TOP TRACK PUNCH OUT
MIN.
3-#8 SCREWS TO EA. STUD FOR STUD TRACK W/
3-#10 SCREWS EA. 6" OR LARGER HEADER POWDER DRIVEN
END, EA. LEG 2-#8 SCREWS TO EA. STUD FOR PINS AT 32" O.C.
4" OR SMALLER HEADER ICBO#2388
J
'd'
DBL. STUD (FULL HT).
TYP.
PUNCHOUT
10/31/2023
SEE NOTE #6
OPENING SILLS)
1 21" MIN.
16 GA. X 3" STRAP EA.
STEEL STUD
I SIDE AT 16" W/ #8
SCREWS EA. END
9
-
HORIZONTAL CONTROL:
6 PLYWOOD
VERTICAL CONTROL:
WHERE
-
G OCCURS
SHEET TITLE:
5 METAL STUD
ADDRESS:
UNPUNCHED TRACK
PROJECT:
- #8 SCREWS AT 12" AT WALL, TOP & BASE
EA. LEG FOR 4" & STUD TYP. W/ 1 21" DEEP LEG
6" LINTEL AND AT UNPUNCHED TOP AND MIN. TYP.
8" EA. LEG FOR 8" BOTTOM TRACK WITH
2
LINTEL WT18x STUD WIDTH
BY:
USE 16 GA. TRACK PLAN WHERE
OCCURS
5'-0"MAX.
WHERE L > 8'-0" 6
DATE:
4" 'C' STUD 16 GA.
CIP NO.
USE DOUBLE 16 GA. - HEADER L = 6'-0" MAX. #8 AT 30" O.C.
TRACK WHERE L > 12'-0" 6" 'C' STUD 16 GA. STRAP BLK'G
F USE DTL 2/- HEADER L = 8'-0" MAX.
TYP.
WHERE OCCURS
DOOR 8" 'C' STUD 16 GA. PER DETAIL 6/- STUD
HEADER L = 10'-0" MAX.
CORNER PLAN
HORIZ. BRACING, SEE
DTL 5/A5.00
3
MIN. STUD SIZE AND FULL HT. DBL. STUD - UNPUNCHED TRACK PLYWOOD
MAX. SPACING PER DOOR OR WINDOW CONT. (SAME WIDTH UNPUNCHED
TRACK W/ 3-#8 WHERE
SCHEDULE JAMB (TYP. U.N.O.) AS STUD)
E AT 30" O.C.
OCCURS
WALL INTERSECTION
REVISIONS:
08 05 02
TYP. METAL STUD WALL ELEVATION MTL. STUD HEADER SECTION MTL. STUD WALL CONNECTIONS
INDEX NO.
REF: -- SCALE: 1" = 1'-0" REF: -- SCALE: 1" = 1'-0" REF: -- SCALE: 1" = 1'-0"
NO.
MAXIMUM SPAN FOR CEILING JOIST
D INTERIOR STEEL STUDS TYPICAL INTERIOR NON-BEARING METAL STUD DETAILS
NOTES:
CITY ENGINEER
DATE:
GAUGE
TYPE 20 18 16 14 12
SPACING
1. ALL STUD TO TRACK, STUD TO STUD OR TRACK TO TRACK
STE 20 12'' 13'-4'' CONNECTIONS MIN. SIZE TEKS SCREWS: NO. 8-18X34" TEKS 2 U.N.O.
x4'' 16'' ON PLANS. FOR 16 GA. AND HEAVIER USE NO. 10-16X34" TWKS MIN.
12'-0''
2. ALL STEEL STUDS, CHANNELS AND TRACKS TO BE SAME GAUGE
STE 20 12'' 17'-6'' U.N.O.
x6'' 3. STEEL STUDS SHALL NOT BE ERECTED UNTIL AFTER FLOOR SLAB
16'' 16'-0''
ABOVE HAS BEEN PLACED.
DIETRICH, ICBO # 4782 4. SEE SPECIFICATIONS FOR SIZE OF STUDS AND METHOD OF
INSTALLATION.
MAXIMUM HEIGHT FOR NON-BEARING 1.375" MIN. 5. STUDS SHALL NOT BE SPLICED EXCEPT AT THE POINT OF
C INTERIOR STEEL STUDS LATERAL SUPPORTS.
(CODE: CWN)
DESIGN GROUP
5.1. WHERE SPLICE IS REQ'D NEST STUDS WITHIN EACH OTHER
GAUGE
TYPE 20 18 16 14 (12" MIN.) AND SECURE WITH 2-#6 TEKS SCREWS EACH
SPACING
FLANGE AT 1" MAX. FROM END OF EACH PIECE.
12'' 13'-11'' 15'-1'' 16'-1'' 17'-2'' 6. TRACK FASTENERS (UNLESS NOTED OTHERWISE)
6.1. TYPE: HILTI LOW VELOCITY POWDER DRIVEN FASTENER
2 1/2'' 16'' 12'-8'' 13'-8'' 14'-8'' 15'-7''
.375 MIN. (DRIVE PINS) (ICBO 1290) PHILLIPS REDHEAD WEDGE ANCHOR
24'' 11'-1'' 12'-0'' 12'-9'' 13'-7'' (ICBO 1372) (L.A. CITY RR2748)
METAL STUD SECTION PROPERTIES 6.2. POWDER DRIVEN PIN (PDP): 0.145 DIAMETER x 1-1/2'' LONG
WEB HEIGHT
APPROVED BY:
DESIGNED BY:
CHECKED BY:
18 GA. .209 .261 18 GA. .388 .777
3 5/8'' 16'' 16'-10'' 18'-3'' 19'-6'' 20'-3''
DRAWN BY:
7. WHERE APPROVED,WALL FINISH IS PROVIDED FULL HEIGHT BOTH
ENGINEER:
16 GA. .255 .318 16 GA. .477 .954
14 GA. .309 .386 14 GA. .582 1.165 SIDES OF WALL PROVIDE BRIDGING AT MIDHEIGHT OF WALL.
24'' 14'-8'' 15'-11'' 17'-1'' 18'-3''
8. WHERE WALL FINISH DOES NOT OCCUR FULL HEIGHT BOTH SIDES
3 1/2'' X20 GA. .255 .446 5 1/2'' X20 GA. .471 1.269 12'' 27'-7'' 29'-8'' 32'-1'' 34'-4'' OF STUDS REFER TO DETAIL 1/X.XX
18 GA. .325 .568 18 GA. .602 1.656 9. DO NOT ATTACH TOP OF STUDS TO TOP CONTINUOUS TRACK
16 GA. .398 .697 16 GA. .742 2.040 6'' 16'' 25'-0' 27'-2'' 29'-2'' 31'-3'' EXCEPT AS SHOWN ON DETAILS. THE PURPOSE OF THESE
14 GA. .485 .849 14 GA. .910 2.503 24'' 21'-10'' 23'-9'' 25'-6'' 27'-3'' DETAILS IS TO ALLOW FOR VERTICAL MOVEMENT DUE TO WORK ORDER NO.
TYP. 'C' STUD SECTION DEFLECTION.
3 5/8'' X20 GA. .267 .484 6'' X20 GA. .532 1.597 12'' 34'-10'' 37'-10'' 40'-7'' 43'-7'' SEE CEILING CONNECTION DETAIL 4B/-.
E170121B
(DESIGN STAGE ONLY)
14 GA. .509 .822 14 GA. 1.031 3.094 24'' 27'-7'' 30'-0'' 32'-3'' 34'-7'' CEILING JOIST PARTITION SCHEDULE &
DIETRICH, ICBO # 4784P DIETRICH, ICBO # 4784P MTL. "C" STUD SECTION PROPERTIES
REF: -- SCALE: 1" = 1'-0"
TYP. INT. NON-BEARING MTL. STUD NOTES
REF: -- SCALE: 1" = 1'-0"
A5.00
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A500_24X36.DWG 12/3/2021 9:23 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
01 DRYWALL
CUT FLANGE OF BLK'G,
K - BRIDGING WHERE BEND WEB & SCREW BLK'G SAME
OCCURS W/ 2-#8 TEK, TYP. GAUGE AS CEILING
JOIST W/ 4-#8 TEK
TOP FLANGE TOP FLANGE 16 GA. UNPUNCHED JOIST PER TO WALL TRACK
BRACING WHERE BRACING WHERE APPROVED TRACK (1 21" LEG) W/ SCHEDULE
OCCURS. FOR DTL OCCURS. FOR DTL SHEATHING + + + + DRYWALL JOIST PER
2-#10 SCREWS EA.
SEE 15&19/- SEE 15&19/- WHERE OCCURS. STUD SCHEDULE
+ +
2-#8 TEK SCREWS TYP.
AT 4" STUD OR JOIST
4-#8 TEK SCREWS TYP. ++
AT 6" STUD OR JOIST ++
J
1'-0" MAX.
12" MIN. JOIST
STAGGER BENT
1-#10 SCREW EA. 2X2X20 GA. ANGLE LAP WHERE OCCURS
WEB OR BLK'G EA.
FLANGE W/ 2-#8 EA. LEG OVER SUPPORT W/
SIDE OF JOIST
2-#8 TEK EA. STUD + + #8 TEK AT 6" O.C.
+ + TO STUD & CEILING 2-#8 TEK SCREWS EA.
JOIST
+ + END OF LAP 10/31/2023
LOCATE 1ST
BRIDGING BELOW
CEILING JOIST
STUD PER STUD PER
SCHEDULE SCHEDULE
03
MTL. CLG. JOIST AT STUD WALL CONNECTION
HORIZONTAL CONTROL:
(2) #8 LOW PROFILE HEAD O.C. MAX. W/ 4-#8 TEK 2-#8 SCREWS TO WEBS OF STUDS
VERTICAL CONTROL:
SCREWS PER STUD TO TRACK
G CEILING JOIST AS PER 20 GA. CHANNEL
SHEET TITLE:
SCHEDULE TRACK AT 48" O.C.
ADDRESS:
PROJECT:
1-#8 TEK SCREWS AT. MAX.
JOIST
DATE:
CIP NO.
ROLLED CHANNEL CONT. BETWEEN BLK'G.
CUT FLANGES AND 2-#8 TEK EA. END
1- #8 SCREW TO EA. STUD FLANGE, 4 TO EA. BLK'G
F BEND WEBS FOR BLK'G TO JOIST
(PLACE STRAP AT 5'-0'' VERTICALLY)
SCREW ATTACHMENT
AT STUD BLK'G DRYWALL CEILING
TYPE 1 TYPE 2 STRAP BOTH SIDES
CEILING A
(NO WALL COVERING EITHER SIDE)
USE AT: USE AT: ATTACHMENT TO (OR NO APPROVED WALL FINISH)
- BASE & WALL CABINETS, SHELVES, - TOILET ACCESSORIES BLK'G PER CODE
AND COUNTERS, U.N.O. - WALL MOUNTED WALL STOPS (3-#8 MIN.)
- SHOWER SEATS - MARKER & TACK BOARDS
- HANDRAILS - SURFACE-MOUNTED FIRE
- GRAB BARS NOTE: BRACING NOT REQ'D WHERE APPROVED
EXTINGUISHER CONTINUOUS SHEATHING ATTACHED TO TOP OF 20 GA. TRACK OR STUD BLK'G APPROVED WALL
- LOCKERS AT 8' -0'' AND EA. END OF WALL COVERING W/
JOIST OCCURS. SEE ARCH. DRWGS FOR LOCATION.
E CUT FLANGES OF TRACK & BEND WEB. 4-#8 TEK SCREWS
2-#8 SCREWS TO WEBS OF STUDS PER BLOCK
REVISIONS:
08 05
MTL. STUD WALL BACKING PLATES - TYPES 1 & 2 TYP. MTL. CLG. JOIST BRACING
INDEX NO.
REF: -- SCALE: 1" = 1'-0" REF: -- SCALE: 1" = 1'-0"
NO.
STRAP SPLICE WHERE REQ'D
20 GA. x 121 '' STL. STRAP OR 121 '' WIDE COLD
D ROLLED CHANNEL CONT. BETWEEN BLK'G.
CITY ENGINEER
1- #8 SCREW TO EA. STUD FLANGE, 4 TO EA. BLK'G
DATE:
20 GA. STUD BLK'G.
CUT FLANGES AND (PLACE STRAP AT 5'-0'' VERTICALLY)
BEND UP WEB W/
JAMB STUD (USE MULTIPLE 1-#8 EA. FLANGE
JAMBS STUDS AS REQUIRED) STRAP ONE SIDE
2-#8 EA. WEB B
JAMB STUD (USE MULTIPLE (WALL COVERING OTHER SIDE)
JAMB STUDS AS REQUIRED)
DESIGN GROUP
2-#8 SCREW
HEADER TRACK EA. LEG
STEEL STUD
SECTION
APPROVED BY:
DESIGNED BY:
CHECKED BY:
OPTION 2 OPTION 1 TRACK AT 48" O.C.
DRAWN BY:
ENGINEER:
NOTE:
W/ 4-#8 SCREWS
BRIDGING OR STRAPING NOT REQ'D WHEN
TO WALL BLK'G.
APPROVED WALL COVER OCCURS BOTH SIDES
U.N.O. ALSO SEE NOTE #7 ON DETAIL1/XXX
E170121B
(DESIGN STAGE ONLY)
PLAN VIEW
A
07 04 01 SHEET NAME
REVISION DATES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A501_24X36.DWG 12/3/2021 9:23 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
DOOR SCHEDULE WINDOW SCHEDULE
DOOR FRAME REMARKS WINDOW GLAZING FRAME REMARKS
K AA ANOD. ALUM PF PAINT FINISH SP SINGLE PANE STF STOREFRONT PF PAINT FINISH
SHEET NO.
DETAIL SHEET NO. U.O.N. GL GLASS SF STAIN FINISH DP DOUBLE PANE GL GLASS STF STOREFRONT
WINDOW NO.
DIMENSIONS DIMENSIONS
GLAZING
U- FACT.
S.H.G.C.
RATING
TEMPERED
LOCATION
MATERIAL
MATERIAL
MATERIAL
DOOR NO.
COLOR
FINISH
FINISH
FINISH
TYPE
TYPE
TYPE
WD WOOD SC SOLID CORE KP KICK PLATE FF FACTORY FINISH AA ANODIZED ALUMINUM
MULLION
FF FACTORY FINISH PH PANIC HARDWARE M METAL DG DOUBLE GLAZE CL CLEAR
THRESH.
JAMB
HEAD
SILL
JAMB
HEAD
LS LOCK SET PS PRESSED STEEL H HANDLE SG SINGLE GLAZE O OPERABLE
WDT HGT THK WDT HGT
CD CLOSER DEVICE STF STOREFRONT ST STEEL TUBE M METAL OB OBSCURE GLASS
SD SMOKE DETECTOR T TEMPERED GL WG WIRE GLASS SF STAIN FINISH
ICE RESURFACER 1" INSULATED +/- 13'-5" +/- 6'-2"
100.1 A 10'-0" 10'-0" 2" STF/ T. GL AA ALUM AA - - - 01/A6.13 11/A6.13 SIM 02/A6.10 PROVIDE WS. SURFACE CLOSER 101.A A - - T STF AA 01/A6.12 01/A6.10 - 01/A6.12 CURTAINWALL WINDOW
ROOM LOW E V.I.F. V.I.F.
+/- 13'-5" +/- 7'-11"
J 100.2 " B 15'-0" 10'-0" 2" M FF ST FF - - - - 12/A6.20 - 15/A6.20 ROLL UP DOOR. 101.B A
V.I.F. V.I.F.
- - T STF AA 01/A6.12 01/A6.11 - 01/A6.12 CURTAINWALL WINDOW
110.1 MECH/ ELEC. ROOM H 6'-0" 7'-0" 1 3/4 HM PF HM PF - - - - 08/A6.20 03/A6.20 07/A6.20 PROVIDE PH. > 800AMPS OF ELEC. EQUIPMENT. CLOSER.
111.1 REF. ROOM C 3'-0" 7'-0" 1 3/4" HM PF HM PF - - - - 08/A6.20 02A/A6.20 07/A6.20 CLOSER.
111.2 " " " " " " " " " " " " " 08/A6.20 02A/A6.20 07/A6.20 LOUVER PER MECH. CLOSER.
HORIZONTAL CONTROL:
112.1 GIRL'S ROOM " " " " " " " " " " " " 08/A6.20 02A/A6.20 07/A6.20 CLOSER.
VERTICAL CONTROL:
112.2 " " " " " " " " " " " " " 08/A6.20 02A/A6.20 07/A6.20 LOUVER PER MECH. CLOSER.
G 113.1 MECH. ROOM H 6'-0" 7'-0" 1 3/4 HM PF HM PF - - - -
SHEET TITLE:
ADDRESS:
PROJECT:
114.1 LOCKER ROOM A C 3'-0" 7'-0" 1 3/4" HM PF HM PF - - - - 08/A6.20 02A/A6.20 07/A6.20 CLOSER.
115.1 SHARED BATH 1 " " " " " " " " " " " " 08/A6.20 02A/A6.20 07/A6.20 CLOSER.
115.2 " " " " " " " " " " " " " 08/A6.20 02A/A6.20 07/A6.20 LOUVER PER MECH. CLOSER.
115.3 " " " " " " " " " " " " " 08/A6.20 02A/A6.20 07/A6.20 CLOSER.
DATE:
CIP NO.
118.1 SHARED BATH 2 " " " " " " " " " " " " 08/A6.20 02A/A6.20 07/A6.20 CLOSER.
F 118.2 " " " " " " " " " " " " " 08/A6.20 02A/A6.20 07/A6.20 LOUVER PER MECH. CLOSER.
118.3 " " " " " " " " " " " " " 08/A6.20 02A/A6.20 07/A6.20 CLOSER.
119.1 LOCKER ROOM D " " " " " " " " " " " " 08/A6.20 02A/A6.20 07/A6.20 CLOSER.
120.1 ICE RINK ICE RINK GATE-SEE SPECS
ICE RINK GATE. SEE SPECS. GATE SHALL REMAIN OPEN DURING PUBLIC
120.2 "
SESSION-PROVIDE SIGN
ICE RINK GATE. SEE SPECS. GATE SHALL REMAIN OPEN DURING PUBLIC
120.3 "
SESSION-PROVIDE SIGN
120.4 " ICE RINK GATE-SEE SPECS
GENERAL NOTES: HAND-ACTIVATED AND ON AN ACCESSIBLE ROUTE SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE
HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE EXCEPTIONS:
REVISIONS:
1. ALL OUT-SWINGING DOORS SHALL HAVE DRIPS AT THE HEAD, TYPICAL. ALL EXTERIOR DOORS SHALL HAVE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. LOCKED EXIT DOORS SHALL A. TEMPERED GLASS DOORS WITHOUT STILES AND HAVING A BOTTOM RAIL OR SHOE WITH THE TOP LEADING
CLOSERS TO MEET ENERGY (T24) REQUIREMENTS. OPERATE CONSISTENT WITH CBC 2019 SECT. 1126A.4 IN THE DIRECTION OF EGRESS. (CBC 2019 1126A.6). EDGE TAPERED AT 60 DEGREES MINIMUM FROM THE HORIZONTAL SHALL NOT BE REQUIRED TO MEET THE 10
INDEX NO.
INCH BOTTOM SMOOTH SURFACE HEIGHT REQUIREMENT.
2. ALL FIRE RATED DOORS SHALL BE FIRE RATED PER THE REQUIREMENTS OF CBC 2019 T 716.5. 16. OMIT. B. DOORS AND GATES THAT DO NOT EXTEND TO WITHIN 10 INCHES OF THE FINISH FLOOR OR GROUND SHALL
NO.
NOT BE REQUIRED TO COMPLY WITH SECTION 11B404.2.10.
3. ALL GLAZING TO BE TEMPERED PER THE REQUIREMENTS OF CBC 2019 T 2406.1.5. 17. ALL STEEL FRAMES SHALL BE CURRIES 'KD' AND FULLY WELDED AT EXTERIOR LOCATIONS.
27. PER CBC 2019 CH11B-404.2.4.3 RECESSED DOORS AND GATES, MANEUVERING CLEARANCES FOR
D 4. ALL FIRE RATED WINDOWS AND/OR DOORS SHALL BE GLAZED WITH FIRE RATED GLASS PER THE 18. OMIT. FORWARD APPROACH SHALL BE PROVIDED WHEN ANY OBSTRUCTION WITHIN 18 INCHES OF THE LATCH SIDE AT
REQUIREMENTS OF CBC 2019 T 716.6. AN INTERIOR DOORWAY, OR WITHIN 24 INCHES OF THE LATCH SIDE OF AN EXTERIOR DOORWAY, PROJECTS
CITY ENGINEER
DATE:
19. DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL MORE THAN 8 INCHES BEYOND THE FACE OF THE DOOR, MEASURED PERPENDICULAR TO THE FACE OF THE
5. ALL EXTERIOR DOORS SHALL MEET STC 27 AT A MINIMUM. KNOWLEDGE OR EFFORT. DOOR OR GATE.
6. NON-REMOVABLE HINGE PINS ARE REQUIRED ON ALL OUT-SWINGING DOORS. 20. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES SHALL BE INSTALLED 34 INCHES
MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR.
7. OMIT.
21. LEVER OR LEVEL OF ACTUATED LATCHES OR LOCKS SHALL BE CURVED WITH A RETURN TO WITHIN 1/2" OF
8. PROVIDE PANIC HARDWARE PER CBC 2019 SECT. 1010.1.10. FOR DOORS SERVING ROOMS OR SPACES WITH THE DOOR OR GATE TO PREVENT CATCHING ON THE CLOTHING OF PERSONS DURING EGRESS (CBC 2019
AN OCCUPANT LOAD OF 50 OR MORE IN A GROUP 'A' OCCUPANCY. EXCEPTION: A MAIN EXIT OF GROUP 'A' SHALL 1126A.6.1).
BE PERMITTED TO BE LOCKING IN ACCORDANCE WITH SECT. 1010.1.9.3, WITH OCC. LOAD OF 300 OR LESS AND A
READILY VISIBLE DURABLE SIGN IS POSTED ON THE EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING: 22. DOOR OPENINGS MUST MEET THE SIZE REQUIREMENTS OF CBC SECTION 2019 CH 11B-404.2.3. PER CBC 2019
C "THIS DOOR IS TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED". THE SIGN SHALL BE IN LETTERS 1 INCH CH 11B-404.2.3 CLEAR WIDTH, DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32" MINIMUM. CLEAR
(25 MM) HIGH ON A CONTRASTING BACKGROUND. OPENINGS OF DOORWAYS WITH SINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND
DESIGN GROUP
THE STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24" DEEP SHALL PROVIDE A CLEAR
9. SUPPLY EXTERIOR RATED DOOR CLOSERS AT ALL SITE GATES. GC SHALL PROVIDE. FORCE SHALL MEET OPENING OF 36" MINIMUM. THERE SHALL BE NO PROJECTIONS INTO THE REQUIRED CLEAR OPENING WIDTH
ACCESSIBILITY REQUIREMENTS. LOWER THAN 34" ABOVE THE FINISH FLOOR OR GROUND. PROJECTIONS INTO THE CLEAR OPENING WIDTH
BETWEEN 34" AND 80" ABOVE THE FINISH FLOOR OR GROUND SHALL NOT EXCEED 4".
10. PROVIDE 1HR RATED DOORS BETWEEN OCCUPANCY 'B' AND 'S-2' TO MEET OCCUPANCY SEPARATION
REQUIREMENTS PER CBC 2019 T 508.4. EXCEPTIONS: DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78" MINIMUM ABOVE THE FINISH
FLOOR OR GROUND.
11. STORAGE ROOM: IF USE OF STORAGE ROOM MEETS CBC 2019 T 509 "INCIDENTAL USES", PROVIDE RATED
DOOR AS REQUIRED BY THAT TABLE. 23. THRESHOLDS AT DOORWAYS SHALL BE 1/2" HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN LEVEL
APPROVED BY:
DESIGNED BY:
CHECKED BY:
DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE
DRAWN BY:
ENGINEER:
MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE MINIMUM ALLOWABLE BY THE
APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS (CBC 2019 1126A.4). 26. PER CBC 2019 CH11B-404.2.10 DOOR AND GATE SURFACES, SWINGING DOOR AND GATE SURFACES WITHIN
10 INCHES OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON
13. IF THE DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR
AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 INCHES VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16" OF THE SAME PLANE AS THE OTHER AND BE FREE
FROM THE LATCH, MEASURED TO THE LANDING EDGE OF THE DOOR (CBC 2019 1126A.4.1). OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED.
WORK ORDER NO.
14. THE TYPE OF LATCH AND LOCK REQUIRED FOR ALL DOORS SHALL BE IN ACCORDANCE WITH CBC 2019 SECT. E170121B
1126A.6 AND CH 10 SECT. 1008 (CBC 2019 1126A.5).
(DESIGN STAGE ONLY)
A SHEET NAME
15. HAND ACTIVATED DOOR LATCHING, LOCKING AND OPENING HARDWARE SHALL BE CENTERED BETWEEN 34
REVISION DATES
INCHES (762MM) AND 44 INCHES (1118MM) ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE
A6.00
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A600_24X36.DWG 12/3/2021 9:23 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
K
W
W W
H
H
H
10/31/2023
SURFACE
I
W
W W
DOOR TYPES
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G
SHEET TITLE:
ADDRESS:
PROJECT:
H
H
10" MIN. SMOOTH
H
SURFACE
DATE:
CIP NO.
F
TYPE J TYPE E
TYPE G
EXT. GATE EXTERIOR DOOR @ HOOD
HM DOOR W/ VISION LITE
W
E
TYPE B
REVISIONS:
ROLL UP DOOR
WINDOW
INDEX NO.
ABOVE. SEE
WINDOW TYPES. W
NO.
D
CITY ENGINEER
DATE:
CURTAIN WALL
W
DESIGN GROUP
H
H
10" MIN. SMOOTH
F F
SURFACE
APPROVED BY:
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
TYPE I W TYPE D TYPE A WORK ORDER NO.
E170121B
HM DOOR W/ GLAZING
(DESIGN STAGE ONLY)
A6.01
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A601_24X36.DWG 12/3/2021 9:23 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
10/31/2023
WINDOW TYPES
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G
SHEET TITLE:
ADDRESS:
PROJECT:
7'-11"
101.B
H
CITY OF
CIP NO.
F
LOS ANGELES
E ETCHED
GRAPHICS ON
101.A
6'-2"
GLASS
REVISIONS:
INDEX NO.
NO.
D
CITY ENGINEER
DATE:
CURTAIN WALL
C SLIDING DOOR
BELOW. SEE
DESIGN GROUP
DOOR TYPES.
10'-0"
APPROVED BY:
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
WORK ORDER NO.
TYPE A E170121B
(DESIGN STAGE ONLY)
A6.02
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A602_24X36.DWG 2/4/2022 10:07 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
H 01 07 G 07 01 F
ENGINEERING
A6.14 A6.13 A6.12 A6.14
2'-6" 1'-0" 30'-3 1/2" 1'-0" 2 1/2" 9 1/2"
18 GA FLAT MTL FASCIA O/ 7/8" CORRUGATED MTL SIDING 18 GA FLAT MTL FASCIA LAP FASCIA O/ CORRUGATED
5 1/2"
FURRING CHANNEL, PTD. LAP FASCIA O/ CORRUGATED O/ 7/8" FURRING CHANNEL, O/ 7/8" FURRING PANEL AS SHOWN.
PANEL AS SHOWN. PTD. CHANNEL, PTD. HSS POST PER STRUCT'L.
4'-0" MIN
02 TRIM CLOSURE, TYP. 02
CORRUGATED MTL SIDING PER SPECS O/ 7/8"
4'-0"
CORRUGATED MTL SIDING PER A6.14 CURTAIN A6.14 CORRUGATED MTL SIDING PER
FURRING CHANNEL O/ WATERPROOFING O/ JAMB FLASHING, C.O. HSS
SPECS O/ 7/8" FURRING CHANNEL WALL, TYP. SPECS O/ 7/8" FURRING CHANNEL
5/8" TYPE 'X' EXT. RATED GYP BRD. TYP. BOTH SIDES. EXTERIOR
O/WATERPROOFING O/ 5/8" TYPE O/WATERPROOFING O/ 5/8" TYPE
03 03
4'-7
'X' EXT. RATED GYP BRD. REV. TYP. ALUM. DOOR PER 'X' EXT. RATED GYP BRD.
A6.11 A6.11 SHIM AS
SCHEDULE.
4'-1 1/2"
J BUILDING PAPER PER SPECS. NECESSARY. BUILDING PAPER PER SPECS.
LIGHT GAUGE MTL STUD LIGHT GAUGE MTL STUD
FRAMING PER STRUCT'L. FRAMING.
6'-0"
HSS POST PER STRUCT'L. HSS POST PER STRUCT'L.
MTL JAMB TRIM PER MANUF. 10/31/2023
MTL TRIM PER MANUF. C.O. HSS
MTL FLASHING AND SEALANT & MTL FLASHING AND SEALANT &
4 1/2"
3/8" BACKER ROD. DOOR PER SCHEDULE.
3/8" MIN BACKER ROD.
LIGHT GAUGE MTL BOX/ CURB. CURTAINWALL. SEALANT & 3/8" BACKER SEALANT & 3/8" BACKER STL CHANNEL FOR MEMBRANE
ROD, TYP. BOTH SIDES. ROD, TYP. BOTH SIDES. ATTACHMENT.
1'-5"
MEMBRANE COLUMN F.O.FINISH
I STRUCTURE PER STRUCT'L. SEALANT & 3/8" BACKER TRIM, TYP. TRIM, TYP. MEMBRANE ABOVE
ROD.
1'-1/2"
H H
6"
INTERIOR C.O.
1'-0"
1 I BEAM 1
B B
6"
GATEWAY DETAILS
CORRUGATED MTL SIDING
PER SPECS O/ 7/8" FURRING
7'-0"
CHANNEL O/ 5/8" TYPE 'X'
GYP BRD.
5'-7 1/4"
SEALANT & 3/8" BACKER
ROD, TYP. BOTH SIDES. ALUM. DOOR PER
6'-0"
SCHEDULE.
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G C.O. HSS
SHEET TITLE:
4 3/4"
ADDRESS:
PROJECT:
F.O.FINISH
HSS POST PER STRUCT'L, TYP. SHIM AS NECESSARY. LIGHT GAUGE MTL STUD FRAMING PER STRUCT'L.
DATE:
CIP NO.
GATEWAY/DOORS PLAN
F REF: 07/A2.00 & 01/A4.00 SCALE: 1 1/2" = 1'-0"
5 1/2"
FURRING CHANNEL, PTD. EXTERIOR PANEL AS SHOWN.
HSS POST PER STRUCT'L.
07
4'-0" MIN
07
4'-0"
CORRUGATED MTL SIDING PER A6.13 CORRUGATED MTL SIDING PER TRIM CLOSURE A6.12 CORRUGATED MTL SIDING PER C.O. HSS
SPECS O/ 7/8" FURRING CHANNEL SPECS O/ 7/8" FURRING CHANNEL TYP. SPECS O/ 7/8" FURRING
E O/WATERPROOFING O/ 5/8" TYPE O/WATERPROOFING O/ 5/8" TYPE 03 FLASHING
CURTAINWALL CHANNEL O/ 5/8" TYPE 'X' EXT.
4'-7
'X' EXT. RATED GYP BRD. 'X' EXT. RATED GYP BRD. TYP. WINDOW PER RATED GYP BRD.
A6.11 SHIM AS SCHEDDULE
4'-1 1/2"
BUILDING PAPER PER SPECS. NECESSARY. BUILDING PAPER PER SPECS.
LIGHT GAUGE MTL STUD LIGHT GAUGE MTL STUD
REVISIONS:
FRAMING PER STRUCT'L. FRAMING.
6'-0"
HSS POST PER STRUCT'L.
INDEX NO.
HSS POST PER STRUCT'L.
MTL JAMB TRIM PER MANUF. MTL TRIM PER MANUF. C.O. HSS
NO.
MTL FLASHING AND SEALANT &
4 1/2"
3/8" BACKER ROD. 5/8" TYPE 'X' EXT.
D RATED GYP BRD. PTD. MTL FLASHING AND SEALANT &
LIGHT GAUGE MTL BOX/ CURB. SEALANT & 3/8" BACKER SEALANT & 3/8" BACKER 3/8" MIN BACKER ROD.
CITY ENGINEER
DATE:
1'-5"
MEMBRANE COLUMN TRIM CLOSURE TYP. ROD, TYP. BOTH SIDES. ROD, TYP. BOTH SIDES. F.O.FINISH
STL CHANNEL FOR MEMBRANE
STRUCTURE PER STRUCT'L. ATTACHMENT. ABOVE
TRIM CLOSURE, TYP. TRIM CLOSURE, TYP.
1'-1/2"
H H
F.O.
0.9 BLDG. 0.9
MEMBRANE COLUMN
STRUCTURE PER STRUCT'L.
6"
CURTAINWALL
ROOF WINDOW
C.O.
1'-0"
1 1
C CORRUGATED MTL SIDING PER I BEAM
SPECS O/ 7/8" FURRING CORRUGATED MTL SIDING
DESIGN GROUP
6"
CHANNEL O/ 5/8" TYPE 'X' EXT. PER SPECS O/ 7/8" FURRING
RATED GYP BRD. CHANNEL O/ 5/8" TYPE 'X'
1'-2 1/2"
GYP BRD.
7'-0"
INTERIOR
5'-7 1/4"
APPROVED BY:
DESIGNED BY:
CHECKED BY:
18 GA FLAT MTL PANEL O/ 5/8" C.O. HSS
DRAWN BY:
ENGINEER:
TYPE 'X' GYP BRD.
4 3/4"
CMU WALL W/CAP BELOW
F.O.FINISH
WORK ORDER NO.
HSS POST PER STRUCT'L, TYP. LIGHT GAUGE MTL STUD FRAMING.
INTERIOR E170121B
(DESIGN STAGE ONLY)
18 GA FLAT MTL PANEL O/ 5/8" 18 GA FLAT MTL PANEL O/ 5/8" TYPE 'X' GYP BRD.
A TYPE 'X' GYP BRD.
01 SHEET NAME
REVISION DATES
H G F
GATEWAY/ CURTAIN WALL WINDOW PLAN
REF: 07/A2.00, 01/A4.00 SCALE: 1 1/2"=1'-0"
A6.10
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A610_24X36.DWG 12/3/2021 9:24 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
K
5/8" TYPE 'X' EXT. RATED GYP BRD.
JAMB FLASHING
BASE FLASHING
J SEALANT & BACKER
CORRUGATED MTL SIDING ROD
BEYOND 18 GA FLAT MTL
PANEL
CURTAINWALL.
SHEET MTL GUTTER,O/ 1/2" 10/31/2023
DENSDECK PRIME SLOPE TO SLOPE
DRAIN.
SHIM AS NECESSARY
GATEWAY DETAILS
06 03
DETAIL @ END OF GUTTER JAMB DETAIL @ CURTAINWALL
REF: 01/-, A4.50 SCALE: 3" = 1'-0" REF: 01/-, A6.10 SCALE: 3" = 1'-0"
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G
SHEET TITLE:
ADDRESS:
PROJECT:
H G F
TYP.
BY:
18 GA FLAT MTL FASCIA O/ 7/8" FURRING CHANNEL, 18 GA FLAT MTL FASCIA O/ 7/8"
DATE:
PTD. FURRING CHANNEL, PTD
CIP NO.
F.O.FINISH
5 1/2"
PANEL AS SHOWN. PANEL AS SHOWN.
HSS POST PER STRUCT'L.
CORRUGATED MTL SIDING PER
SPECS O/ 7/8" FURRING
07 07
CORRUGATED MTL SIDING PER CORRUGATED MTL SIDING PER
CHANNEL O/WTERPROOFING A6.13 EXTERIOR C.O. HSS
SPECS O/ 7/8" FURRING A6.12 SPECS O/ 7/8" FURRING CHANNEL
O/ 5/8" TYPE 'X' EXT. RATED CHANNEL O/ WATERPROOFING O/ WATERPROOFING O/ 5/8" TYPE
GYP BRD. 03
4'-7
O/ 5/8" TYPE 'X' EXT. RATED 'X' EXT. RATED GYP BRD.
GYP BRD. A6.11
4'-1 1/2"
BUILDING PAPER PER SPECS. BUILDING PAPER PER SPECS.
LIGHT GAUGE MTL STUD LIGHT GAUGE MTL STUD
FRAMING. FRAMING.
6'-0"
E
HSS POST PER STRUCT'L. HSS POST PER STRUCT'L.
REVISIONS:
4 1/2"
DENSDECK PRIME. 3/8" MIN BACKER ROD.
INDEX NO.
SHEET MTL GUTTER, SLOPE
1'-5"
FLASHING O/ CURB. F.O.FINISH
TO DRAIN. ABOVE
NO.
06 STL CHANNEL FOR MEMBRANE
01
1'-1/2"
ATTACHMENT.
A8.20 A6.11
D F.O.
0.9 0.9
CITY ENGINEER
BLDG.
DATE:
MEMBRANE COLUMN
STRUCTURE PER STRUCT'L.
6"
C.O.
1'-0"
1 I BEAM 1
CORRUGATED MTL SIDING
6"
PER SPECS O/ 7/8" FURRING
CHANNEL O/ 5/8" TYPE 'X'
1'-2 1/2"
GYP BRD.
7'-0"
FLAT MTL. PANEL BELOW 01
DESIGN GROUP
CURTAINWALL A8.20
5'-7 1/4"
ROOF WINDOW
BELOW
6'-0"
STEEL CHANNEL AS REQ'D TO
CMU WALL BELOW. ATTACH MEMBRANE MATERIAL.
LIGHT GAUGE MTL BOX/ CURB.
C.O. HSS
4 3/4"
TYPE 'X' GYP BRD, PTD. TO
B MATCH CORRUGATED MTL
PANEL.
APPROVED BY:
F.O.FINISH
DESIGNED BY:
CHECKED BY:
DRAWN BY:
CMU WALL BELOW. HSS POST PER STRUCT'L, TYP.
ENGINEER:
LIGHT GAUGE MTL STUD FRAMING.
LIGHT GAUGE MTL STUD FRAMING.
INTERIOR
18 GA FLAT MTL PANEL O/ 5/8"
TYPE 'X' GYP BRD. 18 GA FLAT MTL PANEL O/ 5/8" TYPE 'X' GYP BRD,
PTD. TO MATCH CORRUGATED MTL PANEL.
E170121B
(DESIGN STAGE ONLY)
A
01 SHEET NAME
REVISION DATES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A611_24X36.DWG 12/3/2021 9:24 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
K 09
0.9 1 0.9 1
A4.50
SEE DETAIL A 01/A6.12
I BEAM
BLDG.
C.O.
F.O.
6'-0" 7'-0"
5 1/2" 4'-1 1/2" 4 1/2" 1'-1/2" 6" 6" 5'-7 1/4" 4 3/4"
F.O.FINISH
F.O.FINISH
F.O.FINISH
C.O. HSS
C.O. HSS
C.O. HSS
SPECS O/ 7/8" FURRING CHANNEL
O/ 5/8" TYPE 'X' GYP BRD.
J CURTAINWALL PER
SLOPE 18 GA FLAT MTL FASCIA, O/ BUILDING SPECS.
PAPER O/ SLOPED INSULATION O/ 1/2"
DENSDECK PRIME. SLOPE TO DRAIN AS
INDICATED. 01
A6.10 10/31/2023
+10'-0"
LIGHT GAUGE MTL FRAMING PER T.O.OPENING
STRUCT'L. TYP.
GATEWAY DETAILS
WINDOW
CORRUGATED MTL SIDING PER
SPECS O/ 7/8" FURRING CHANNEL
BASE FLASHING
O/ 5/8" TYPE 'X' GYP BRD.
02
SHEET MTL GUTTER, A6.10
HORIZONTAL CONTROL:
SLOPE TO DRAIN.
VERTICAL CONTROL:
1/2" DRIP, TYP.
G
SHEET TITLE:
CORRUGATED MTL PANEL PER SPECS,
ADDRESS:
PROJECT:
O/ 7/8" FURRING CHANNEL O/ BUILDING
PAPER O/ 5/8" TYPE 'X' EXT. RATED GYP
BRD, TYP.
BY:
FOOTING PER STRUCT'L. SLAB ON GRADE PER
DATE:
CIP NO.
STRUCT'L.
STL. CHANNEL FOR
MEMBRANE
F 3/8' RUBBER FLOORING
1/2" MAX.
ATTACHMENT
REVISIONS:
HSS STRUCTURE PER
STRUCT'L, TYP.
INDEX NO.
SEE 01/A3.00
SELF ADHERING
NO.
FLEXIBLE FLASHING,
TYP. @ HEADERS.
D SHIM AS NECESSARY.
CITY ENGINEER
DATE:
PANEL CLOSURE
TRIM, TYP.
DESIGN GROUP
07 BACKER ROD, TYP. SPECS O/ 7/8" FURRING CHANNEL
A2.00 O/ 5/8" TYPE 'X' GYP BRD.
01
A6.11 WINDOW
APPROVED BY:
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
0.9 1
SEE DETAIL B 01/A6.12 0.9 1
E170121B
(DESIGN STAGE ONLY)
A
01 SHEET NAME
REVISION DATES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A612_24X36.DWG 12/3/2021 9:24 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
K
1 0.9 09 1 0.9
A4.50 SEE DETAIL A 01/A6.13
1'-2 1/2" 6" 6'-0"
1'-2 1/2" 6" 6'-0"
SEE 07/A2.00
2'-0"
CURTAINWALL PER
SPECS
GATEWAY DETAILS
ALUM. STOREFRONT
DOOR JAMB, SEE DOR
SCHED.
BASE FLASHING
02
HORIZONTAL CONTROL:
SHEET MTL
VERTICAL CONTROL:
A6.10
GUTTER,O/ 1/2"
G DENSDECK PRIME
SHEET TITLE:
SLOPE TO DRAIN. 1/2" DRIP, TYP.
ADDRESS:
PROJECT:
CORRUGATED MTL PANEL PER SPECS, O/ 7/8"
FURRING CHANNEL O/ BUILDING PAPER O/
5/8" TYPE 'X' EXT. RATED GYP BRD, TYP.
BY:
STRUCTURE TYP.
01 ALUM. STOREFRONT
DATE:
CIP NO.
STL CHANNEL FOR A6.11 DOOR, BOTTOM CLOSED,
MEMBRANE ATTACHMENT. WEATHER STRIPPING ON
F BOTTOM
SEALANT & 3/8" MIN BACKER FOOTING PER STRUCT'L. THRESHOLD, SET IN FULL
ROD O/ SHIM. CORRUGATED MTL PANEL MASTIC BED.
THRESHOLDS SHALL BE
FLASHING
ACCESSIBLE TYP.
SLAB ON GRADE PER SEE 03/A0.23
5/8" TYPE 'X' GYP BRD. PTD. STRUCT'L.
SLOPE AWAY FROM
1/2" MAX.
LIGHT GAUGE MTL STUD THRESHOLD
6" MIN.
REVISIONS:
PAPER O/ 5/8" TYPE 'X' EXT. RATED GYP
BRD, TYP.
INDEX NO.
NO.
SEE 01/A3.00
CITY ENGINEER
DATE:
C
PANEL CLOSURE
DESIGN GROUP
TRIM, TYP.
07
A2.00
APPROVED BY:
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
1 0.9
E170121B
(DESIGN STAGE ONLY)
A
01 SHEET NAME
REVISION DATES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A613_24X36.DWG 12/3/2021 9:24 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
10/31/2023
GATEWAY DETAILS
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G
SHEET TITLE:
CORRUGATED MTL PANELS PER
ADDRESS:
18 GA FLAT MTL FASCIA, PTD TO
PROJECT:
SPECS O/ 7/8" FURRING CHANNEL MATCH CORRUGATED MTL SIDING,
O/ 5/8" TYPE 'X' EXT. RATED GYP
O/ 7/8" FURRING CHANNEL O/
BRD.
BUILDING PAPER O/ 5/8" TYPE 'X'
EXT. RATED GYP BRD.
BUILDING PAPER PER SPECS.
CIP NO.
F BUILDING PAPER PER SPECS.
CURB, BEYOND.
SELF ADHERING FLEXIBLE
SELF ADHERING FLEXIBLE
FLASHING, TYP.
FLASHING, TYP.
E
SANDWICH LEADING EDGE OF 6" CONC. CURB. SEE STRUCT'L SANDWICH LEADING EDGE OF
MTL BASE FLASHING W/ SELF
FOR REINFORCEMENT. MTL BASE FLASHING W/ SELF
ADHERING FLEXIBLE FLASHING,
ADHERING FLEXIBLE FLASHING,
TYP.
TYP.
REVISIONS:
INDEX NO.
PROVIDE 1/4" GAP @ BASE, TYP. PROVIDE 1/4" GAP @ BASE, TYP.
NO.
REINFORCEMENT.
MTL BASE FLASHING, 2" MIN. MTL BASE FLASHING, 2" MIN.
CITY ENGINEER
1/2" IMPREGNATED EXPANSION JOINT. EXPANSION JOINT.
DATE:
ASPHALT PAVING PER CIVIL ASPHALT PAVING PER CIVIL
DWGS. DWGS.
SLAB ON SLAB ON
C GRADE PER GRADE PER
DESIGN GROUP
STRUCT'L. STRUCT'L.
UNDERSLAB MOISTURE
UNDERSLAB
BARRIER, TYP. WHERE
MOISTURE BARRIER,
REQUIRED.
BASE PLATE PER STRUCT'L. TYP. WHERE
REQUIRED.
BASE PLATE PER STRUCT'L.
APPROVED BY:
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
FOOTING PER FOOTING PER
STRUCT'L. STRUCT'L.
E170121B
(DESIGN STAGE ONLY)
A
04 01 SHEET NAME
REVISION DATES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A614_24X36.DWG 12/3/2021 9:24 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
JANITOR VESTIBULE 108
15"
J
19"
LABC 1110.A3. ADHERED TO CONC.
5/8" UNDERCUT
FLASHING, SET IN
BUTTERED SEALANT. 0'-0"
T.O.S
1/2" DRIP
4"
A1.11
2"
DOOR HEIGHT
CONT'S SEALANT & 3/8" GROUT & FRAME
MIN BACKER ROD, BOTH
I SIDES.
ANCHOR.
ICE RESURFACER
ROOM WALL JAMB, BEYOND. CONC. SLAB ON
WEATHER SEAL, TYP.
GRADE
DOOR DETAILS
REF: DOOR SCHEDULE SCALE: 1-1/2" = 1'-0" REF: DOOR SCHEDULE SCALE: 1-1/2" = 1'-0" REF: DOOR SCHEDULE, SECTIONS SCALE: 3" = 1'-0" REF: DOOR SCHEDULE SCALE: 3" = 1'-0" REF: -- SCALE: 3" = 1'-0"
HORIZONTAL CONTROL:
ALUM. THRESHOLD, DOOR PER SCHEDULE.
VERTICAL CONTROL:
PER SPECS, SET IN WALL TYPE
PROVIDE 1-HR RATED DOOR BOTTOM
PER PLANS
G NOTE: ALL STEEL SHALL BE HOT DIPPED MASTIC. SMOKE SEAL WHERE REQ'D PER
HARDWARE SCHED.
SHEET TITLE:
GALVANIZED - NATURAL FINISH.
@ THRESHOLD - TYP.
ADDRESS:
PROJECT:
EXTERIOR INTERIOR SEE WALL -- ONE PIECE ALUMINUM
MAX.
1/2" MAX VERT.
TYPES. MTL. STUD WALL THRESHOLD SET IN MASTIC.
DOOR DRIP PER 2 2
1/4"
FRAMING BOX HEADER
1/4" STL PLATE 1-1/2"X1/2" HARDWARE SPECS. 1 1
ALIGN
1/2"
@ GATE JAMB, STL TOP & COMPLY W/ CBC 2019
BEYOND - SEE BOTTOM CH11B-404.2.10.
BY:
RAIL. CONC. PAVEMENT, 5"
FLOOR FINISH MIN BACKER ROD, BOTH
1-1/2"X1-1/2" PER CIVIL DWGS. HM, KD FRAME & HM
PER SCHEDULE. SIDES.
A
DATE:
2
CIP NO.
X3/16" STL DOOR PER SCHEDULE.
HORIZ. & 1
F VERT. HSS SLOPE GROUT & FRAME
1 1/2"
TYP.
DOOR PER SCHEDULE.
H PER DOOR SCHEDULE
FRAME. ANCHOR.
1/2" MAX.
1/2" MAX.
SIDE. ONE PIECE ALUMINUM
WALL JAMB, THRESHOLD SET IN MASTIC.
1-1/2"X1-1/2" CLOSER, WHERE
X3/16" STL BEYOND. OCCURS. SEE 2
HORIZ. HSS. SCHEDULE. 1
CRUSHED AGGREGATE 8" GALV. SHEET METAL
AND SOIL COMPACTION PAN FLASHING,
E PER CIVIL. SOLDERED ONE PIECE.
1/2" IMPREGNATED NOTE:
1"
REVISIONS:
REQUIRED.
14 11 08 05 02
INDEX NO.
TYP. PICKET GATE SECTION EXT. THRESHOLD @ CONC. PAVEMENT TYP. HEAD @ CMU WALL TYP. HM DOOR HEAD TYP. DOOR THRESHOLD
NO.
REF: DOOR SCHEDULE, A3.10 SCALE: 3" = 1'-0" REF: DOOR SCHEDULE, SECTIONS SCALE: 3" = 1'-0" REF: DOOR SCHEDULE, SECTIONS SCALE: 3" = 1'-0" REF: DOOR SCHEDULE, SECTIONS SCALE: 3" = 1'-0" REF: DOOR SCHEDULE SCALE: 3" = 1'-0"
CITY ENGINEER
DATE:
DOOR THRESHOLD, 5/8" 1 1/2"
CMU FENCE. BEYOND.
ALUM. THRESHOLD, DOOR PER SCHEDULE.
HM DOOR FRAME.
1/2"
PER SPECS, SET IN SEE 03/--. DOOR AND FRAME PER
1/4" SPACER. L3X3X3/16" STL MASTIC. SCHEDULE, PTD. PER
ANGLE TAB. BOLT FINISH SCHEDULE.
EQ
1-1/2"X1-1/2"X3/16" CONT'S SEALANT & 3/8"
TO WALL. MIN BACKER ROD.
VERT. HSS. EXTERIOR INTERIOR
SCREW TO GATE HINGE
DOOR DRIP PER
PARTITION WIDTH
PARTITION WIDTH
WALL WITH PER SPECS.
COUNTERSUNK HARDWARE SPECS.
C CONCRETE/ 2"X1/2" FLAT BAR. COMPLY W/ CBC 2019
MASONRY CH11B-404.2.10.
DESIGN GROUP
1-1/2"X1/2" HORIZ.
SCREWS. ASPHALT PAVING, PER FLOOR FINISH
BOTTOM RAIL.
1-1/2"X1-1/2"X3/16" CIVIL DWGS. PER SCHEDULE.
1/2"X1/2" STL 2
HORIZ. &
PICKET @ 4" O.C. 1
VERT. HSS.
SLOPE
1/2" MAX.
EQ
10" TALL KICK 1/2"X1/2" STL
PLATE, BEYOND. PICKET @ 4" O.C.
1/2"
APPROVED BY:
SEE WALL
DESIGNED BY:
CHECKED BY:
1-1/2"X1-1/2"X3/16" WALL TYPE ENTRY DOOR FRAME PER
TYPES.
DRAWN BY:
ENGINEER:
VERT. HSS. PER PLANS SPEC'S.
3-1/2"X1/4" CRUSHED AGGREGATE 8" GALV. SHEET METAL
SCREW TO GROUT & FRAME
STL PLATE. AND SOIL COMPACTION PAN FLASHING, NOTE: FOR METAL FRAMES SET INTO MASONRY OR CONCRETE, USE 8" WIDTH
WALL WITH ANCHOR.
COUNTERSUNK PER CIVIL. SOLDERED ONE PIECE. UNLESS OTHERWISE NOTED. DOOR FRAMES SHALL BE FLUSH-FRAME PROFILE,
CONT'S SEALANT & 3/8"
CONCRETE/ 1/2" IMPREGNATED TYP. FULLY WELD AT ALL EXTERIOR LOCATIONS AND GRIND SMOOTH.
MIN BACKER ROD.
MASONRY EXPANSION JOINT & WORK ORDER NO.
SEALANT. HM DOOR PER
SCREWS.
SCHEDULE. E170121B
CMU FENCE.
(DESIGN STAGE ONLY)
A
13 10 07 04 01 SHEET NAME
REVISION DATES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A620_24X36.DWG 12/3/2021 9:24 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SITE LIGHTING SCHEDULE (SEE ELEC. DWGS) FINISH SCHEDULE ENGINEERING
TYPE MANUFACTURER MODEL SIZE COLOR/ FINISH LAMP REMARKS WALL FLOOR CEILING REMARKS
116 LOCKER ROOM B CMU P1 RB CMU P1 RB CMU P1 RB CMU P1 RB CONC RB MTL P1 SEE NOTE #1.
BUREAU OF ENGINEERING
ACCESSORY SCHEDULE 117 LOCKER ROOM C SEE NOTE #1.
COLOR/ 118 SHARED BATH. 2 CMU GL.F COVE CMU GL.F COVE CMU GL.F COVE CMU GL.F COVE CONC RB MTL P1 ALL WALLS SHALL HAVE GL.F. FLOOR @ SHOWERS IS CONC.
ROOM NO. ROOM NAME ACCESSORY (QTY.) MANUFACTURER MODEL SIZE FINISH REMARKS
119 LOCKER ROOM D CMU P1 RB CMU P1 RB CMU P1 RB CMU P1 RB CONC RB MTL P1 SEE NOTE #1.
105 JANITOR UTILITY SHELF BRADLEY 9983 30" SS SURFACE MOUNT
HORIZONTAL CONTROL:
MEN'S &
VERTICAL CONTROL:
106,107 WOMEN'S GRAB BAR TOILET (2) BRADLEY 382 42" SS-SATIN CONCEALED MOUNTING
RESTROOM PLUMBING FIXTURE SCHEDULE
G PARTITION-MOUNTED TOILET SEAT-COVER DISPENSER,
SHEET TITLE:
SANITARY NAPKIN DISPOSAL AND TOILET TISSUE ONLY IN WOMEN'S ROOM
ADDRESS:
DISPENSER-SERVES 2 TOILET COMPARTMENTS (2) NO. ROOM NAME FIXTURE MANUFACTURER MODEL SIZE COLOR/ FINISH REMARKS
PROJECT:
BOBRICK B-3571 - SS RESTROOM
ADA RECESSED TOILET SEAT-COVER DISPENSER,
SANITARY NAPKIN DISPOSAL & TOILET TISSUE ONLY IN WOMEN'S 104 BREAK ROOM SINK FAUCET DELTA B1310LF - CHROME
DISPENSER BOBRICK B-3574 - SS RESTROOM
SINK KOHLER VAULT K-3996-1 SS - REAR OUTLET DRAIN (MAINTAIN 1" MAX COUNTERTOP THICKNESS FOR ADA COMPLIANCE)
PARTITION-MOUNTED TOILET SEAT-COVER AND TOILET
BY:
(1) BOBRICK B-3471 - SS ONLY IN MEN'S RESTROOM
105 JANITOR MOP SINK ADVANCE TABCO 9-OP-40DF 18.5"X25"X16" (VIF) SS -
DATE:
CIP NO.
ADA RECESSED TOILET SEAT-COVER DISPENSER &
TOILET TISSUE DISPENSER (1) SERVICE FAUCET ADVANCE TABCO K-240 - - -
BOBRICK B-3474 - SS ONLY IN MEN'S RESTROOM
F
ADA MIRROR (2) TOILET (8) AMERICAN STANDARD MADERA FLOWISE 3461001.020 ELONGATED, 16 1/2" HEIGHT WHITE (3 IN MEN'S, 5 IN WOMEN'S)FLOOR MOUNT, TOP SPUD, HIGH EFFICIENCY, EVERCLEAN, 1.28 GPF.
BOBRICK B-165 18" x 36" SS SEE INT. ELEVATIONS
LAV SOAP DISPENSER (2) FLUSH VALVE (8) AMERICAN STANDARD ULTIMA SELECTRONIC 6065121 - CHROME AT TOILETS.
BOBRICK B-822 34 OZ. SS MEN'S
ONLY IN REFEREE RESTROOMS, URINAL (3) AMERICAN STANDARD ALLBROOK 6550001.020 - WHITE ONLY IN MEN'S RESTROOM. ADA COMPLIANT.
TOILET TISSUE DISPENSER (1) 106, 107
BOBRICK B-2740 12 1/2" x 4 7/8" ALUM RESTROOM WOMEN'S FLUSH VALVE (3) AMERICAN STANDARD SELECTRONIC 606B.051 - CHROME AT URINALS. ADA COMPLIANT. PURCHASE POWER KIT SEPARATELY
ONLY IN REFEREE RESTROOM
LAVATORY (4) HI-MACS SINGLE SINK 1715 17" W x 15" L x 5" D ARCTIC WHITE INTEGRATED OVERFLOW. ADA COMPLIANT
ADA RECESSED SEAT COVER DISPENSER (1) BOBRICK B-301 15 3/4" x 11" SS RESTROOM
FAUCET (4) AMERICAN STANDARD MOMENTS SELECTRONIC 2506192.002 - CHROME ADA COMPLIANT. HARD-WIRED AC.
REF. 10 13/16" x 13
PAPER TOWEL DISPENSER (2) BOBRICK B-4262 1/2" x 4 7/8" SS SURFACE MOUNTED.
RESTROOM,
111,112
E GIRL'S 13 3/8" x 13 3/8" TOILET (2) AMERICAN STANDARD MADERA FLOWISE 3461001.020 ELONGATED, 16 1/2" HEIGHT WHITE FLOOR MOUNT, TOP SPUD, HIGH EFFICIENCY, EVERCLEAN, 1.28 GPF.
RESTROOM WASTE RECEPTACLE W/ COVER (2) BOBRICK B-2250 x 29 1/2" SS FLOOR STANDING.
COAT HOOK (2) BOBRICK B-542 SS REF. RESTROOM, FLUSH VALVE (2) AMERICAN STANDARD ULTIMA SELECTRONIC 6065121 - CHROME AT TOILETS.
- 111, 112
GIRL'S RESTROOM LAVATORY (2) AMERICAN STANDARD DECORUM 9024.011EC 20" W x 18 1/4" L x 5" D WHITE RIGHT HAND SOAP DISPENSER.
GRAB BAR TOILET (2) BRADLEY 382 36" SS-SATIN CONCEALED MOUNTING
REVISIONS:
FAUCET (2) AMERICAN STANDARD MOMENTS SELECTRONIC 2506192.002 - CHROME ADA COMPLIANT. HARD-WIRED AC.
GRAB BAR TOILET (2) BRADLEY 382 42" SS-SATIN CONCEALED MOUNTING
ADA RECESSED TOILET SEAT-COVER DISPENSER, BOBRICK B-3574 SS ONLLY IN GIRL'S
INDEX NO.
SANITARY NAPKIN DISPOSAL & TOILET TISSUE RESTROOM LAVATORY (4) HI-MACS SINGLE SINK 1715 17" W x 15" L x 5" D ARCTIC WHITE INTEGRATED OVERFLOW. ADA COMPLIANT
DISPENSER
NO.
SHARED FAUCET (6) AMERICAN STANDARD MOMENTS SELECTRONIC 2506192.002 - CHROME ADA COMPLIANT. HARD-WIRED AC.
115, 118
BATHROOM 1 & 2 TOILET (2) AMERICAN STANDARD MADERA FLOWISE 3461001.020 ELONGATED, 16 1/2" HEIGHT WHITE FLOOR MOUNT, TOP SPUD, HIGH EFFICIENCY, EVERCLEAN, 1.28 GPF.
REF. ROOM, LOCKER ROOM MIRROR (6) BOBRICK B-165 18" x 54" SS SEE INT. ELEVATIONS
D 111, 112, GIRL'S LAVATORY (2) AMERICAN STANDARD DECORUM 9024.011EC 20" W x 18 1/4" L x 5" D WHITE RIGHT HAND SOAP DISPENSER.
CITY ENGINEER
DATE:
114,116,117 ROOM,
,119 LOCKER
ROOMS NOTES: LAV SINK AT SHARED BATHROOMS (NOT IN ADA WATER CLOSETS), MEN'S AND WOMEN'S RESTROOMS IS AN INTEGRAL BOWL SOLID SURFACE COUNTERTOP BY 'LG HI-MACS' OR EQUAL.
INSTALL GRAB BARS @ ALL ACCESSIBLE STALLS.
MIRROR (2) - - 13' (VIF) x 36" FRAMELESS SEE INTERIOR ELEVATIONS COUNTERTOP/ BACKSPLASH AT BREAK ROOM IS SOLID SURFACE BY 'CORIAN' OR EQUAL.
COUNTERTOP PAPER TOWEL DISPENSER (2) BOBRICK B-526 - SS - SEE DWGS. FOR CLEARANCES ASSOCIATED WITH PLUMB. FIXTURES.
3 IN EA. SHARED (LEED 3.1) HIGH-EFF. FIXTURES ARE SPECIFIED FOR:
LAV SOAP DISPENSER (6) BOBRICK B-822 34 OZ. SS BATHROOM (INCLUDES 1 IN
EA. ADA RESTROOM)
C
CIRCULAR WASTE CHUTE FOR MOUNTING IN
DESIGN GROUP
COUNTERTOPS (2) BOBRICK B-529 7' DIA SS -
FLOOR STANDING WASTE RECEPTACLE (2) BOBRICK B-2260 SS OPEN TOP-NO COVER
TEAKWORKSFORY APPLIANCES
FOLDING SHOWER SEAT (2) TBF-340160W 24" L X 16" D WOOD ADA COMPLIANT
OU ROOM NO. ROOM NAME MANUFACTURER ENERGY STAR MODEL SIZE FINISH REMARKS
GRAB BAR SHOWER (2) BRADLEY 382 48" SS-SATIN CONCEALED MOUNTING 104 BREAK ROOM GE YES GTE17GTN/GSN 16.6 CU S.S
SHARED
GRAB BAR SHOWER (2) BRADLEY 382 14" SS-SATIN CONCEALED MOUNTING
115,118 BATHROOMS GENERAL NOTES: WITH WHITE GROUT, 3" x 6" SIZE IN RUNNING BOND PATTERN, WITH TOP WAINSCOT TILE TO 17. ALL CABINET PULLS SHALL BE TRIMCO, TYP. #562-3
APPROVED BY:
PAPER TOWEL DISPENSER IN ADA RESTROOM (2)
DESIGNED BY:
BOBRICK B-4262 1/2" x 4 7/8" SS SURFACE MOUNTED. 2. PER CBC 2019 SECTION 11B-302.1, FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM 11. INSTALL GRAB BARS AT TOILETS & TUBS OF ACC. BATHROOMS PER ACCESSORY REFLECTING SURFACE, TYP.
CHECKED BY:
DRAWN BY:
AND SLIP RESISTANT. SCHEDULE & PLANS.
ENGINEER:
13 3/8" x 13 3/8"
WASTE RECEPTACLE W/ COVER (2) 21. SEE SHEET A0.23-A0.25 FOR ADDITIONAL INFORMATION.
BOBRICK B-2250 x 29 1/2" SS IN ADA RESTROOM
3. CHANGES IN LEVEL SHALL COMPLY WITH CBC 2019 SECTION 11B-303. 12. NEW PLUMBING FIXTURES AND FITTING SHALL NOT EXCEED THE MAXIMUM ALLOWABLE
TOILET TISSUE DISPENSER IN ADA RESTROOM (2) BOBRICK B-2740 12 1/2" x 4 7/8" ALUM SURFACE MOUNTED. FLOW RATES SPECIFIED IN CBC SECTION 5.303.3 22. -23. OMIT.
4.- 6. OMIT
ADA RECESSED SEAT COVER DISPENSER (2) BOBRICK B-301 15 3/4" x 11" SS SURFACE MOUNTED. 13. OMIT 24. ALL SOLID SURFACE COUNTERTOPS SHALL HAVE A SIDE SPLASH AT ADJOINING WALL.
GRAB BAR IN ADA RESTROOM (2) BRADLEY 382 36" SS-SATIN CONCEALED MOUNTING 7. ALL APPLIANCES SHALL BE ENERGY STAR RATED IF SUCH A DESIGNATION EXISTS FOR WORK ORDER NO.
THAT APPLIANCE. 14. BASE CABINETS SHALL BE REMOVABLE UNDER 'WORK SPACE'. 'SINK SPACE' HAS NO BASE 25. SEE SHEET A0.23 FOR MOUNTING HEIGHTS OF FIXTURES, MIRRORS, SINKS, TOILETS, ETC.
GRAB BAR IN ADA RESTROOM (2) BRADLEY 382 42" SS-SATIN CONCEALED MOUNTING CABINETS BUT HAS A 'CABINET DOOR' KICK PANEL AND FLOORING SHALL EXTEND UNDER THE
E170121B
(DESIGN STAGE ONLY)
COAT HOOK (6) 8. NON PAPER-FACED, MOLD AND WATER RESISTANT DRYWALL SHALL BE USED IN ALL COUNTER TO THE WALL, TYPICAL. 26. ALL KITCHEN SINKS AND ALL LAVS AT BATHROOM COUNTERS SHALL BE 'UNDER-MOUNT'
A BOBRICK B-542 - SS ALL DOORS
BATHROOMS. TYPE TO MEET THE 'MAX. 34" COUNTERTOP HEIGHT.' SHEET NAME
REVISION DATES
15. DEPTH OF KITCHEN SINK BOWL SHALL BE 6-1/2" MAX. (ONLY ONE BOWL OF DOUBLE-SINK
10. CERAMIC TILE AT ALL BATHROOM WALLS SHALL BE THIN-SET, WHITE, 'SEMI-GLOSS' FINISH
BOWL SINK SHALL COMPLY).
16. MAX. HT. SHALL BE 46" FOR 50% OF SHELVING IN KITCHEN (OBSTRUCTED HIGH SIDE
REACH).
27. WATER SUPPLY AND DRAIN PIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED
OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP
OR ABRASIVE SURFACES UNDER LAVATORIES AND SINKS . (11B-606.5)
A7.00
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A700_24X36.DWG 12/3/2021 9:24 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
I
FURNISHING/ EQUIPMENT SCHEDULE
ROOM NO. ROOM NAME FURNISHING/EQUIPMENT MANUFACTURER OR EQ. MODEL SIZE COLOR/ FINISH REMARKS
ENTRY / SNACK MERCHANDISER VENDING COM - 35.2"W x 34.75"D x 72"H PER OWNER 32 SELECTIONS, OR EQUAL
SCHEDULES (FF&E)
DESKS PER OWNER - SEE A4.00 PER OWNER -
102 OFFICE CHAIRS PER OWNER - SEE A4.00 PER OWNER -
SKATE STORAGE RACK (3) RINKSYSTEMS - SEE A4.00 PER OWNER FLOOR MOUNTED
HORIZONTAL CONTROL:
VERTICAL CONTROL:
SKATE SHARPENER BLADE MASTER - SEE A4.00 PER OWNER OR EQUAL
G 103 SKATE STORAGE TABLE PER OWNER - SEE A4.00 PER OWNER -
SHEET TITLE:
SKATE STORAGE RACK RINKSYSTEMS - SEE A4.00 PER OWNER FLOOR MOUNTED
ADDRESS:
PROJECT:
111, 112, REF. ROOM, SHELF W/ EQUIPMENT HOOKS RINKSYSTEMS - - - SEE INT. ELEVATIONS
114,116,117, GIRL'S ROOM,
119 LOCKER ROOMS BENCH RINKSYSTEMS - - - SEE INT. ELEVATIONS. WALL MOUNTED W/ BRACKETS
DATE:
CIP NO.
120 ICE RINK
SLED HOCKEY BOXES PER OWNER - - - REMOVABLE
F
REVISIONS:
INDEX NO.
NO.
D
CITY ENGINEER
DATE:
C
DESIGN GROUP
CITY OF LOS ANGELES
B
APPROVED BY:
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
WORK ORDER NO.
E170121B
(DESIGN STAGE ONLY)
A SHEET NAME
REVISION DATES
A7.00A
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A700A_24X36.DWG 12/3/2021 9:24 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
WALL, PER WALL
TYPE/FINISH SCHEDULE
K
WALL, PER LOCATION - 1/4" THK. STEEL ANGLE
WALL TYPE/FINISH PTD. FRAME WELDED TO
SCHEDULE HSS AND ANCHORED TO
WALL
1/4" THK. STEEL ANGLE INTERMEDIATE 1/4" THK.
PTD. FRAME WELDED TO STEEL ANGLE AS NEEDED,
HSS AND ANCHORED TO PTD. WELDED TO HSS &
WALL STEEL ANGLE
03
FINISH DETAILS
MIRROR
8"
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G
SHEET TITLE:
ADDRESS:
PROJECT:
PTD. HSS 1 1/2" X 1 1/2" X
3/16" CONTINUOUS
SUPPORT FRAME FOR
MIRRORS. TO TERMINATE
6" FROM EDGE OF
BY:
DATE:
CIP NO.
F
MIRROR
VARIES
24" MAX.
1'-0"
BACK SPLASH 4" TALL.
40" AFF
MAX.
REVISIONS:
8'' MIN.
4"
INDEX NO.
NO.
3 1/2" MAX.
D CTA-XX-P OR CTA-XX-PL ADA WHEELED
CITY ENGINEER
TRAFFIC TRANSITION FROM TARKETT OR
DATE:
CLEAR ACRYLIC CONCRETE SIM. ARCHITECT TO SELECT COLOR.
SEALER BY ARDEX OR SIM. TRANSITION TO BE 21" MAX HEIGHT W/ 1:2
SMOOTH FINISH AND SLIP MAX BEVELED EDGE THE ENTIRE LENGTH
RESISTANT PER LABC 1/4" THK. STEEL ANGLE
OF THE EXPOSED EDGE. PTD. FRAME WELDED TO
1110.A3.
3/8" REGUPOL AKTIV RUBBER FLOORING HSS AND ANCHORED TO
GLUED TO CONC. SLAB WALL
PTD. HSS 1 1/2" X
0'-3/8" 1 1/2" X 3/16"
A.F.F SUPPORT FRAME.
C 1/4" SHIM
2'-10"
DESIGN GROUP
SOLID SURFACE OVER 1 LAYER OF
29" MIN.
3/4" PLYWOOD.
CONC. SLAB ON GRADE
27" MIN.
INTEGRAL BOWL SOLID SURFACE
LAV SINK W/ OVERFLOW. SEE
SCHEDULE.
APPROVED BY:
DESIGNED BY:
CHECKED BY:
DRAWN BY:
ENGINEER:
WORK ORDER NO.
E170121B
(DESIGN STAGE ONLY)
A 04 01 SHEET NAME
REVISION DATES
REF:
WHEELED TRAFFIC TRANSITION
SECTIONS,FINISH PLAN, ENLARGED PLANS SCALE: 3" = 1'-0"
BATHROOM COUNTERTOP @ SHARED BATHROOMS
REF: A7.10 - A7.13 SCALE: 3" = 1'-0"
A7.01
X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A701_24X36.DWG 12/3/2021 9:25 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
K
12'-0"
T.O. INT. WALL
9.04
ELEC. OUTLET @
46" MAX A.F.F. TYP.
@ ALL KITCHEN 12 09
OUTLETS. - -
J 9.04
SOLID SURFACE
COUNTER OVER
PLYWOOD
FIXED PANEL. 2'-0" ABSOLUTE MAX
COUNTER TOP
1 1/2"
2'-0" ABSOLUTE MAX 26.03 26.03 10/31/2023
1 1/2"
4"
4"
34" MAX. A.F.F. 34" MAX. A.F.F. REFRIGERATOR
2'-1"
2'-6"
UNDER CABINETS.
INSULATED HOT PER SPECS - SEE
1'-11"
4" BACKSPLASH
REQ'D.
D F D
INTERIOR ELEVATIONS
SPACE. 0'-3/8"
4"
4"
HORIZONTAL CONTROL:
VERTICAL CONTROL:
12 09 02
G
TYP. KITCHEN SINK SECTION TYP. KITCHEN CABINET SECTION INTERIOR ELEVATIONS AT BREAK ROOM
SHEET TITLE:
ADDRESS:
PROJECT:
REF: 02/- SCALE: 1" = 1'-0" REF: 02/- SCALE: 1" = 1'-0" REF: 01 / A4.00 SCALE: 1/2" = 1'-0"
DATE:
CIP NO.
B.O.MTL. DECK
4.01
9.04
8.01
E
22.05
9.04 HI
8.01 18"- 19" 8.01 8.01 8.01
REVISIONS:
GRIPPING SURFACE
INDEX NO.
33"-36" TO T.O.
43" MAX.
38" MIN.
22.05
43" MAX.
36" MAX.
36" MAX.
NO.
15" 15"
38" MIN.
LOW
27" MIN.
CLR. CLR.
D 0'-3/8"
CITY ENGINEER
DATE:
A.F.F
0'-0"
T.O.S
1'-6"
1'-6" WING WALL/ GRAB BAR 1'-6" WING WALL/ GRAB BAR
MIN. CLR. MIN. CLR.
TYP. @ WATER FOUNTAINS. TYP. @ WATER FOUNTAINS.
DESIGN GROUP
REF: 01 / A4.10 SCALE: 1/2" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A7.10
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A710_24X36.DWG 12/3/2021 9:25 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
9'-7 1/2"
B.O.MTL. DECK
9'-1 1/2"
J B.O. BEAM
9.04
9.07
9.07
TYP. @
BATHROOM 10/31/2023
WALLS
10" 10"
9.04 10.01 9.07 9.07
8.01 8.01
10.01
I 6" MAX.
10.05
1'-0" 24" 10"
GRIPPING SURFACE
6'-0"
6'-0"
40'' MIN. - 48'' MAX.
REACH RANGE
GRIPPING SURFACE
20" MIN. 10.06 10.06 7"-9"
4'-0" MAX.
33"-36" TO T.O.
12.03 24" MAX 1'-8"
40" MAX.
40" MAX.
2'-10" MAX.
2'-10" MAX.
PER 11B-903
GRAB BAR
19" MAX.
17" MIN.
17" MIN.
H
INTERIOR ELEVATIONS
1'-6"
0'-3/8"
A.F.F
0'-0"
T.O.S
17" MIN. 10.12 17" MIN. PROVIDE INSULATION ON 10.03 22.06
22.06
18" MAX. 18" MAX. HOT & COLD PIPES, TYP.
TYP. LOCATE VALVE ON
OPEN SIDE (NOT IN CORNER/
A B C D
AGAINST THE WALL)
HORIZONTAL CONTROL:
A B C D
VERTICAL CONTROL:
02
G
INTERIOR ELEVATION AT REFEREE'S ROOM 111
SHEET TITLE:
ADDRESS:
PROJECT:
REF: 01 / A4.30 SCALE: 1/2" = 1'-0"
DATE:
CIP NO.
B.O.MTL. DECK
1"X10" RECYCLED PLASTIC BOARD
F (COLOR TO BE DETERMINED BY 4.01
OWNER).TYP @ ALL LOCKER ROOMS.
4'-6" MIN.
24" MIN. 22.02 22.02
MIN. MIN.
10.09 10.13
22.02 17"MIN.
10.05
12.03 2"X10" RECYCLED
REVISIONS:
10.04 10.04 24" MAX.
PLASTIC BOARDS
6'-0"
REACH RANGE
GRIPPING SURFACE
INDEX NO.
4'-0" MAX.
@32" O.C. POWEDERCOAT
33"-36" TO T.O.
40" MAX.
40" MAX.
40" MAX.
FINISH. TYP.
2'-10" MAX.
2'-10" MAX.
2'-10" MAX.
NO.
22.06
1'-8" MIN.
19" MAX.
17" MIN.
D 0'-3/8"
CITY ENGINEER
DATE:
A.F.F
0'-0"
T.O.S
10.03 22.06 17" MIN. 1/2" CONC. ANCHOR. 2 PER 2'-6" 22.06 1'-6" MIN. 1'-6" MIN. PROVIDE INSULATION ON
18" MAX. BRACKET. CLR. FLOOR SPACE 10.06 HOT & COLD PIPES, TYP.
CLR.
A 11B-903.2 B C D
DESIGN GROUP
REF: 01 / A4.30 SCALE: 1/2" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A7.11
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A711_24X36.DWG 12/3/2021 9:26 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
9.04
10" 10/31/2023
8.01 8.01
22.05
10.09 EQUIPMENT
22.05 HI 10"
I HOOKS @ 18"O.C.
9.04
20" MIN.
12.03
43" MAX.
24" MAX
33"-36" TO T.O.
38" MIN.
4'-0"
36" MAX.
15" 15"
CLR. CLR.
18" MAX.
17" MIN.
0'-3/8" 0'-3/8"
INTERIOR ELEVATIONS
0'-0" 0'-0"
T.O.S T.O.S
1'-6" A B A
WING WALL/ GRAB BAR 1'-0"
MIN, CLR.
TYP. @ WATER FOUNTAINS.
HORIZONTAL CONTROL:
VERTICAL CONTROL:
02 01
G
INTERIOR ELEVATION AT VESTIBULE INTERIOR ELEVATION AT LOCKER ROOM C (TYP.)
SHEET TITLE:
ADDRESS:
PROJECT:
REF: 01 / A4.30 SCALE: 1/2" = 1'-0" REF: 01 / A4.40 SCALE: 1/2" = 1'-0"
DATE:
CIP NO.
B.O.MTL. DECK
9'-1 1/2"
F B.O. BEAM
5.06 5.06 5.06
4'-6" MIN.
SHELVES HOOKS @ 18"O.C. HOOKS @ 18"O.C.
&HOOKS
PORTION OF EQUIP.SHELVING
@ 18"O.C. 9.04
9.04
REVISIONS:
WITHIN REACH RANGE
6'-0"
6'-0"
40'' MIN. - 48'' MAX.
INDEX NO.
20" MIN.
12.03 12.03 PER 11B-903 12.03
1'-6" MIN. 24" MAX
NO.
1'-8" MIN.
18" MAX.
17" MIN.
D 0'-3/8"
CITY ENGINEER
DATE:
A.F.F
0'-0"
T.O.S 2'-6" 2'-6"
CLR. FLOOR SPACE B CLR. FLOOR SPACE C D
11B-903.2 1'-0" 11B-903.2
MIN.CLR.
1'-0" MIN. CLR.
DESIGN GROUP
REF: 01 / A4.40 SCALE: 1/2" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A7.12
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A712_24X36.DWG 12/3/2021 9:26 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
10/31/2023
4.01
8.01
10.01
10.01
I
10.13
9.07
10.05
12" MAX. 42" MIN.
4'-0" MAX.
10.04
7"-9"
40" MAX.
2'-10" MAX.
10.06
INTERIOR ELEVATIONS
1'-7" MIN.
19" MAX.
19" MAX.
17" MIN.
17" MIN.
A.F.F A.F.F
T.O.S T.O.S
22.06 10.03
A1 C1
HORIZONTAL CONTROL:
VERTICAL CONTROL:
G
SHEET TITLE:
ADDRESS:
PROJECT:
PTD. HSS 1 1/2" X1 1/2" X 3/16"
CONTINIOUS SUPPORT FOR
BY:
LED TAPE LIGHT
9'-7 1/2"
DATE:
CIP NO.
B.O.MTL. DECK
9'-1 1/2"
F 23.07 B.O. BEAM
GRIPPING SURFACE
10.04 MIN. MIN.
33"-36" TO T.O.
22.02 22.02
10.06 22.02
REVISIONS:
10.04
INDEX NO.
4'-0" MAX.
4'-0" MAX.
40" MAX.
22.02
2'-10" MAX.
NO.
10.13
D
CITY ENGINEER
10.06
DATE:
A.F.F
T.O.S
1'-6" SEE 02/ A8.01 FOR GLAZED CMU 10.07 3.03 10.12 22.06
MIN. CLR. 3'-0" MIN. CLR. COVE BASE TO FLOOR DETAIL 1'-6" 1'-6"
BEYOND MIN. CLR. 01 (2) 3/4" PLY W/ LAMINATE TO MATCH COLOR OF 01 MIN. CLR. TYP. LOCATE VALVE ON
@ACCESSIBLE SHOWER TYP.@ WET LOCATIONS.
A7.01 INTEGRAL COUNTER TOP. TYP, OF (2) FOR A7.01 OPEN SIDE (NOT IN CORNER/
COUNTER SUPPORT IN SHARED BATHROOMS. AGAINST THE WALL)
REV.
SEE SHEET A0.23 &A0.24 FOR ADDITIONAL SEE SHEET 3/A7.01 FOR BATHROOM
ACCESSIBILITY NOTES COUNTER TOP FRAMING SUPPORT PLAN
C 01
INTERIOR ELEVATIONS AT SHARED BATHROOM
DESIGN GROUP
REF: 01 / A4.40 SCALE: 1/2" = 1'-0"
APPROVED BY:
LEGEND
DESIGNED BY:
5.02 STL. BEAM PER STRUCT'L. PTD. 7.07 BATT INSULATION. RATED' AT BATHROOMS. PAINT. 10.09 SHELF. 23.08 MECH. EQUIPMENT. 32.02 GRAPHICS/PAINT.SEE LAND. DWGS. BOLLARDS AS REQ'D.
CHECKED BY:
ALL LIKE ITEMS UNLESS NOTED OTHERWISE.
9.02 CONC. FLR. SEAL PER FIN. SCHED. 22.03 JANITOR MOP SINK. 33.03 ELECTRICAL METER.
DRAWN BY:
5.03 HSS POST PER STRUCT'L. PTD. 10.10 NETTING. NIC 13 - SPECIAL CONSTRUCTION 32.03 STORMWATER MANAGEMENT PER CIVIL
ENGINEER:
01 - GENERAL REQUIREMENTS 5.04 HSS BEAM PER STRUCT'L. PTD. 08 - OPENINGS (SEE DOOR/WINDOW SCHED) 9.03 RUBBER FLR. PER SPECS. 10.11 FIRE EXTINGUISHER. RECESSED 13.01 MEMBRANE STRUCTURE. 22.04 PLUMBING VENT PIPE. 26 - ELECTRICAL DWGS. 33.04 POWER POLE.
02 - NOT USED 5.05 MEMBRANE STRUCTURE I BEAM. 8.01 STL. DOOR. & FRAME, PAINTED. 9.04 PAINT PER SPECS. CABINET 22.05 DRINKING FOUNTAIN. 26.01 ELEC. PANEL PER PLANS & SCHED. 32.04 STL. SECURITY GATE, PTD.
5.06 MTL. DECK. 8.02 CLR. ANODIZED ALUM. STOREFRONT 9.05 REVEAL PER DETAILS. 10.12 TOILET SEAT COVER DISPENSER. 14 - CONVEYING EQUIPMENT (NOT USED) 22.06 ULTRA LOW-FLOW TOILET. 26.02 EXTERIOR LIGHT PER SCHED. 32.05 STL. SECURITY FENCE, PTD.
03 - CONCRETE 5.07 MTL. GUARD RAILING. DOOR. 9.06 GRAFITTI COATING, TYP. @ ALL 10.13 PAPER TOWEL DISPENSER. 22.07 SHOWER HEAD/ CONTROLS. 26.03 INTERIOR LIGHT PER SCHED. 32.06 EXTERIOR AREA DRAINS.
3.01 CONC. SLAB ON GRADE PER STRUCT'L. 5.08 MTL. STUD WALL. 8.03 CLR. ANODIZED ALUM. STOREFRONT EXTERIOR SOLID WALLS. 10.14 BATHROOM PARTITION W/ ROBE HOOK 21 - FIRE SUPPRESSION 22.08 SHOWER DRAIN. 32.07 BENCH.
3.02 CONC. O/MTL. DECK PER STRUCT'L. WINDOW. 9.07 GLAZED FINISH ON CMU. @ EA. DOOR 21.01 FIRE EXTINGUISHER. 22.09 AREA DRAIN. 27 - COMMUNICATION 32.08 TRENCH DRAIN. WORK ORDER NO.
3.03 CONC. CURB 06 - WOOD AND PLASTICS 8.04 DOOR HARDWARE SET PER SCHED. 9.08 CERAMIC TILE. 21.02 FIRE SPRINKLER HORIZ. MAIN (SEE 22.10 HOSE BIB. 32.09 TREE, SEE LANDSCAPE DWGS.
3.04 CONC. FOOTING PER STRUCT'L. 8.05 EXTERIOR WALL LOUVER. 11 - EQUIPMENT/APPLIANCES (SEE EQMT. DIAGRAM) 28 - ELECTRONIC SAFETY AND SECURITY 32.10 PLANTING, SEE LANDSCAPE DWGS. E170121B
(DESIGN STAGE ONLY)
3.05 CONC. PAVING PER CIVIL DWGS. 07 - THERMAL & MOISTURE PROTECTION 8.06 EXTERIOR WALL VENT WITH CAP. 10 - SPECIALTIES SCHED) 21.03 FIRE SPRINKLER VALVE ASSEMBLY 23 - HEATING, VENTILATING, AND 28.01 SMOKE ALARM. 32.11 (N) CONCRETE SIDEWALK, CURB,
A 3.06 CONC. SIDEWALK PER CIVIL DWGS. 7.01 W.P. MEMBRANE PER DETL. & SPECS. 8.07 ROLLING STL. DOOR & FRAME. 10.01 MIRROR PER SPECS. 21.04 FIRE DEPT. MAIN CONNECTION @ AIR-CONDITIONING 28.02 SECURITY CAMERA. GUTTER PER CITY OF LA STANDARDS.
SHEET NAME
23.01 HVAC UNIT PER MECH.
REVISION DATES
3.07 CONC. PAD 7.02 SINGLE PLY PVC ROOFING PER SPECS. 8.08 ICE RINK GATES 10.02 SIGNAGE. 12 - FURNISHINGS FRONT OF PROJECT. LAFD SHALL 28.03 FIRE ALARM MAIN PANEL. 32.12 (N) CONC. APRON & DRIVEWAY CURB
23.02 AIR REGISTER WALL MOUNTED.
A7.13
7.03 R-21 RIGID INSULATION @ WALLS. 8.09 OVERHEAD GLASS DOOR. 10.03 TOILET PAPER ROLL HOLDER PER 12.01 BICYCLE RACKS FOR SHORT-TERM BIKE APPROVE FINAL LOCATION. CUT PER CITY OF LA STANDARDS.
8.10 ACCESS PANEL, COLOR TO MATCH ACCESSORY SCHED. PARKING. 21.05 FIRE SPRINKLER HEAD. 23.03 CEILING AIR REGISTER. 32.13 EQUIPMENT SCREEN.
04 - MASONRY 7.04 UNDERSLAB MOISTURE VAPOR 31 - EARTHWORK
ADJACENT MATERIAL. 10.04 GRAB BAR. 12.02 DASHERBOARDS. NIC. 23.04 MAKE UP AIR LOUVER PER MECH. 32.14 CONC. WALL @ SITE FENCE.
4.01 CMU BLDNG. WALL BARRIER. 31.01 APPROVED COMPACT FILL PER GEO &
8.11 ROOF ACCESS HATCH. 10.05 COAT HOOK. 12.03 BENCH. NIC. DWGS
4.02 CMU SITE WALL W/ 2" CMU CAP. 7.05 ROOF DRAIN AND OVERFLOW. 22 - PLUMBING SOIL ENGINEER REPORT. X X
SHEET OF SHEETS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Z:\B+S ARCHITECTURE\019 JOBS\01935.0 CITY OF LA-RESEDA ICE HOCKEY ROLLER RINK\01935.0 1.CURRENT DRAWINGS_24X36\01935.0_A713_24X36.DWG 12/3/2021 9:26 AM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENGINEERING
10.14 9.08 6" TYP. 6" TYP. 9.08 10.14 10.04 9.08
TYP. TYP. W/ GRAB BAR BACKING
SEE 07/A0.24, TYP.
9.07
DOOR, SEE
10.01 SCHEDULE
I
(N) COMBO UNIT, AMBULATORY 6" MAX. 12" MAX.
FOR ALL ACCESS. 42" MIN.
10.01
ACCESSORIES COMPARTMENT. 24" 1'-0"
GRIPPING SURFACE
10.13
33"-36" TO T.O.
40" MAX.
2'-10" MAX.
22.06
10.06
INTERIOR ELEVATIONS
17" MAX.
19" MAX.
17" MIN.
10.13
0'-3/8"
10.06 A.F.F
0'-0"
EQ EQ EQ EQ T.O.S
PROVIDE INSULATION ON 17" MIN. 22.06
22.06
18" MIN. HOT & COLD PIPES, TYP. 18" MIN. 18" MAX.
TYP. TYP. TYP. LOCATE VALVE ON
A B OPEN SIDE (NOT IN CORNER/ C D
AGAINST THE WALL)
HORIZONTAL CONTROL:
VERTICAL CONTROL:
02
G
INTERIOR ELEVATIONS AT MEN'S RESTROOM
SHEET TITLE:
ADDRESS:
PROJECT:
REF: 01 / A4.10 SCALE: 1/2" = 1'-0"
CIP NO.
PTD. HSS 1 1/2" X1 1/2" X 3/16"
CONTINIOUS SUPPORT FOR
F SEE 04/ A8.01 FOR TILE TO MIRRORS W/ CONCEALED
CEILING DETAIL TYP. LED TAPE LIGHT
8'-0"
A.F.F
REVISIONS:
1'-0'' MIN.
GRIPPING SURFACE
INDEX NO.
10.13
33"-36" TO T.O.
10.03
2'-10" A.F.F.
40" MAX.
2'-10" MAX.
NO.
10.06
22.06
19" MAX.
17" MIN.
D 10.13
0'-3/8"
CITY ENGINEER
10.06
DATE:
A.F.F