1.3 Safety instructions Switches for rated voltages above Read this user manual carefully before commissioning the 1 kV and less than 52 kV switchgear. Make sure that you have read and understood • IEC 60282-1: High-voltage fuses – Part 1: all safety warnings and instructions. Current-limiting fuses 1.3.1 General instructions • IEC 62271-105: High-voltage alternating current switch- fuse combinations Eaton has done its utmost to inform user as accurately and • IEC 60470: High-voltage alternating current as fully as possible concerning any dangers involved in contactors and contactor-based using the system. Users are responsible for supervising motor-starters. implementation of the instructions contained in this manual. Eaton Power Xpert® switchgear can be used in areas under Personnel normal conditions as described in IEC 62271-1, Chapter The user must make sure that personnel are qualified to 2.1. carry out the task. 1.3.2 Safety of the Switchroom Safety of bystanders The installation and the switchroom must comply with all Access to the equipment is to be limited to those directly applicable local safety regulations. The switchroom is the involved in operating or maintaining it. room in which the switchgear has been set up and must meet at least the following requirements: Other persons must not remain in the vicinity of the equipment. - Clear space Front Access: During switching operations, no personnel must be behind If the switchgear is arranged for front cable access then no or above the installation. rear or side clear space is required. However Eaton recommends at least 1mtr at one end of the switchgear is Safety plan left to allow for ease of installation. It may be necessary to draw up a safety plan. Comprehensive advice on this should be obtained from the Rear Access: relevant authorities (fire brigade, local authorities, If the switchgear is arranged for Rear cable access then a occupational health & safety, company safety department, clear space of 0.5m is required to the wall of the switch- first aid service etc.). room and 0.5m space at either end of the switchboard to Safety standards allow for adequate escape routes. Power Xpert® UX switchgear complies with the following standards: All installations: At the front of the switchgear Eaton recommends a • IEC 62271-200: AC metal-enclosed switchgear and dimension of at least 1.5mtr at the front of the switchgear to control gear for rated voltages allow for ease of operation, removal of vacuum circuit above 1 kV and up to and including breaker from the panel and adequate escape route. 52 kV; • IEC 60529: Degrees of protection provided by Facing installations: enclosures (IP code); At the front of the switchgear Eaton recommends a • IEC 62271-1: General conditions for high voltage dimension of at least 2m. switchgear and control gear standards
The components used comply with standards:
• IEC 62271-100: High-voltage alternating current circuit-
breakers • IEC 62271-102: Alternating current disconnectors and earthing switches • IEC 60044-1: Instrument transformers – part 1: Current transformers • IEC 60044-2: Instrument transformers – part 2: Voltage transformers