You are on page 1of 10

 

59 secs

Grade 100.0 out of 100.0

Feedback Congratulations! You have passed this quiz.

Question 1
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
The footing beams can be constructed with joints if:
Choose one answer.

Select one:
a 450mm diameter pier is provided within 600mm of the joint
2 R20 dowels are provided per joint
The joint is dowelled
all of the given answers are correct

Question 2
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
In the notation, ‘All cross rods Y12-350 lap to be 450 UNO’, UNO stands for:
Choose one answer.

Select one:
Unless noted otherwise
Under no-one
none of the given answers

Question 3
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
The diameter of the piers under the pad footings is:
Choose one answer.

Select one:
750mm
500mm
none of the given answers are correct
600mm

Question 4
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
The difference in height between the sunscreen and the top of the wall panels is:
Choose one answer.

Select one:
1035mm
none of the given answers are correct
1100mm
1.14m
1140mm

Question 5
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
How many Y16 U bars are needed in the reinforcement cage for one PF2 pad footing?
Choose one answer.

Select one:
12
24
14
none

Question 6
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
BMT stands for base metal thickness.

Select one:
True
False

Question 7
Complete
Mark 5.0 out of 5.0
Flag question

Question text
Please refer to Project 3
The height of the rear wall panels above ground floor finished floor level is:
Choose one answer.

Select one:
7235mm
6200mm
none of the given answers are correct
6845mm

Question 8
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
The floor finishes to the buildings are:
Choose the most correct answer

Select one:
carpet to the office area
concrete to the workshop areas
none of the given answers are true
all of the given answers are true
ceramic tiles to the ‘wet’ areas

Question 9
Complete
Mark 5.0 out of 5.0
Flag question

Question text
Please refer to Project 3
The pad footings are:

Select one:
all of the given answers are correct
1.44m2 in area
0.6m in depth
1200X1200mm in area
made of concrete

Question 10
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
The maximum allowable step in the footing beam is 400mm.

Select one:
True
False

Question 11
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
If a dimension is not obvious from the plans, it is acceptable to scale from these
architectural drawings:

Select one:
True
False

Question 12
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
R20 dowel bars are provide across joints in the floor slabs to prevent differential movement between
the slabs:

Select one:
True
False

Question 13
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
“DJ” and “SC” are types of joints provided in the concrete floors.

Select one:
True
False

Question 14
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
The Alsynite fibreglass roof sheeting is to:
Choose one answer.

Select one:
none of the given answers are correct
prevent the passage of Alsyns into the building
provide contrast in the roof sheeting colour
provide natural light to each unit
prevent maintenance workers falling through the roof

Question 15
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
The footing plan depicts:
Choose one answer.

Select one:
all of the given answers are correct
a footing beam under each wall
many circular bored piers
a pier and beam footing system with some pad footings
pad footings under columns

Question 16
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
The ‘throat’ dimension to the reinforced concrete stairs is:
Choose one answer.

Select one:
150mm
Y12-200
400mm
200mm

Question 17
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
The pitch of the roof in degrees is:
Choose one answer.

Select one:
4
5
3
3 and 5

Question 18
Complete
Mark 5.0 out of 5.0
Flag question

Question text
Please refer to Project 3
The roof ventilators have a radius of 800mm.

Select one:
True
False

Question 19
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
The roof sheeting is mainly 0.48mm in thickness BMT Trimdeck Hi-Ten zincalume finish

Select one:
True
False

Question 20
Complete
Mark 5.0 out of 5.0

Flag question

Question text
Please refer to Project 3
Steel rods tie the concrete wall panels to the concrete footings and floor slabs:
Select one:
True
False

You might also like