A. GENERAL CONDITIONS
1. This set of specification shall administer the methods of construction as well as the kinds of
materials to be used for the proposed building shown in the plane and detailed drawings.
2. The plans, detailed drawings and their specifications shall be complementary each other so
that what is shown in one. Although not shown in the other shall be considered as appearing
on both.
2. MANSORY WORKS
For all exterior walls use 6” concrete hollow blocks locally manufactured all 6” hollow blocks
shall b reinforced with 10mm diameter vertical bars at 0.60mm and 10mm diameter
horizontal bars at every 0.60m and 10mm diameter horizontal bars at every 0.60m.
3. MATERIALS
Cement shall conform to ASTM standard. Use only one brand for the whole
structural and masonry works.
Fine aggregates for concrete, grout: stone screenings or other materials with similar
characteristics: clean, hard, strong, durable, free from dust, lumps soft or flaky
particles, shale, alkali, loam or clay.
Coarse aggregates: Gravel; well-drained, clean, hard particles of gravel or crushed
rocks, 25mm (1”) dia. Maximum for slab. Clean, washed sand approved equal.
Steel reinforcement: Structural grade steel: with minimum Fy= 227.378 MPa. (3300
Psi), Intermediate Grade Steel: with minimum Fy= 275.8 MPa (4000 psi)
Tie wire: Ga. 16 galvanized iron (GI) at joints or laps of placed reinforcement as
indicated in the plans. Refer to structural plans and conforming to ASTM standard,
deformed for concrete and masonry requirements.
Water: fit for drinking, free from injuries amount of oil, acids, alkali, organic materials
and other deleterious substances.
4. FORMWORKS
Construct all form complete with centering coarse molds conform to shape, form line
grade, maintain rigid to prevent deformation under I load.
6. CONCRETE WALLS
a. All walls to be reinforced according to the schedule of wall reinforcement unless
other indicated.
b. Reinforced bars to 0.03 meters clear from the face of the wall except in 0.10 meters
wall where it will be at the center.
c. Carry the vertical bars 0.06 meters above the floor level to provide the splicing within
the splicing within the necessary; elsewhere stop at 0.05 meter below the top of the
slab or solid band.
d. Horizontal and vertical bars, if necessary, shall be applied be lapping a distance
equal 40 diameters. Wire securely with #16 F.1 wire provided the spicing in the
adjacent bars are staggered at least 1.50 meters on center.
e. All walls spanning, opening and wall acting as beams to have vertical reinforcement
bent U-form like stirring and spaced according to the schedule of wall reinforcement,
unless otherwise stated.
f. In wall reinforcement alternate intersection of vertical and horizontal bare shall be
connected with #16 C.I. wire to the opposite intersection to give the required
distance in accordance with the notes on concrete walls.
7. SLABS
a. All slabs reinforcement to be 0.02 meters clear from the bottoms and 0.15 meters
clear from the top of the slab.
b. Bend bars at 30 degrees angle.
c. Use #3 dia. Temperature bar
d. Spaced 12” o.c. both ways
8. CEMENT FINISHES
a. All concrete surfaces including those indicated as cement finishes, other than floors
and steps and surfaces where other applied finish is required shall be given a finish
done and applied in following manner.
1. Immediately after removal of forms, all projecting wire and bolts and other
devices used for tying forms shall be cut-off at least one-half cm. beneath the
finish surface. All holes, voids, depressions, and other defects shall be
thoroughly wetted and then painted up solid with cement.
2. Where tiles bricks are specified in drawing, tiles shall be firmly laid on 1:2 cement
mortar.
d. Windows
All jalousies shall be in accordance with the detailed drawing.
Windows schedule is provided on the bill of materials.
All window frames ¼“thick glass, color of frame as per architect’s or
owner’s choice.
e. Partitions
Partitions shall be accordance with the detailed drawings.
f. Ground Floor
1. Living area - (Polished concrete)
2. Dining area - (Polished concrete)
3. Bedrooms - (Polished concrete)
3. Kitchen - (Polished concrete)
5. Toilet & Bath – (ceramic tile 12” x 12”)
g. Second Floor
1. Living area - (Polished concrete)
2. Dining area - (Polished concrete)
3. Bed rooms – (Polished concrete)
4. Toilet & Bath – (ceramic tile 12” x 12”)
5. Kitchen - (Polished concrete)
6. Balcony – Rough finish
II. PAINITNG
GENERAL
Surface Examination - No painting shall be done under conditions, which will jeopardize the quality or
appearance of painting or finishing.
Preparation - All surfaces shall be in proper condition to receive the finish. All woodwork shall be sandpapered
to smooth and finished dusted clean; all knotholes, pitch pockets, or sappy portions shall be shellacked or
sealed with wood filler. Nail holes cracks or defects shall be carefully puttied after the first coat. Matching the
color paint or stain, all imperfection in plaster shall be filled with patching. Compound and smoothened off to
match adjoining surfaces.
CHOICE OF COLOR
The owner must first be consulted after he has given the color scheme. No painting job shall be done unless it
has met the approval of the owner regarding the color.
VARNISHING
1. All woodwork to be varnished must first be thoroughly sandpapered and all cracks hole, and other defects
must be thoroughly and carefully filled with the first quality colored or white putty tinted to match the desired
finish.
2. No man-on-the-job wood filler will he allowed. It should be a first quality wood filler.
3. Before varnishing a sample must be applied for approval of the owner.
III. ELECTRICAL
All electrical works herein shall be done in accordance with these plans and specifications, the applicable
provisions of the latest edition of the Philippine Electrical Code, the rules and regulations of the local enforcing
authority and the requirements of the local power and telephone companies. The electrical works shall be
under immediate supervision of a duly licensed Electrical Engineer.
Power service to the building shall be 230 volts, 1-phase 60HZ, AC power source, 2-wire + 1-ground.
All electrical wiring installation such as lighting, power, fire alarm & CCTV system to be used shall be polyvinyl
chloride (PVC) pipe. “Schedule 40”
Unless otherwise specified, the minimum size of wire shall be 2.0mm TW/THHN2 and conduit shall be
20mmØ electrical trade size.
All wire shall be copper and thermoplastic insulated type “THHN/THWN” unless otherwise indicated in the
plans and shall be manufactured by Phelps dodge or approval equal.
All outlet boxes shall be galvanized gauge no. 16, deep type with factory knockouts. Cover all junction boxes
(no exposed wire)
Panelboards shall be of dead-front type construction with adequate wire space, surface mounted, finished in
industrial grey enamel over a coat or rust inhibitor. Minimum thickness shall be 1.4mm (GA 16). Circuit
breakers shall be quick-make, quick break, trip-free on overload and short-circuit edition, bolt-on type. All circuit
breakers and panelboard shall be “G.E or square-D)”.
All wiring devices shall be “National” or approved equal.
All materials to be used shall be brand new and must be approved type for the particular
location and purpose intended.
Provide grounding system to all lighting and power circuit as per Philippine Electrical Code
requirement.
Mounting heights are: (Subject to Architect’s approval)
A. Light Switches --- 1.20M above floor finish
B. Convenience Outlets --- 0.30M above floor finish
D. Panelboard --- 1.40M above floor finish
Pull boxes shall be used when applicable for easy pulling of wires and shall be according to
code requirement. All fluorescent ballast shall be high power factor, rapid start, spring loaded
lamp holder and enclosed in metallic box.
Provide flexible metal conduit and sufficient mica tube from junction boxes to lighting fixtures.
Upon completion of Electrical construction work, the following test shall be performed by the
contractor inclusive of the installation to be reported in details and in forms approved by the
owner’s representative:
A. Operational Test
IV. PLUMBING
All plumbing works included herein shall be executed according to the provision of the
Philippine Plumbing code the national building code & the rules & regulations of the city or
municipality where the project will be built.
Coordinate the drawing with other related drawings and specification the engineer shall be
notified immediately of any discrepancy found therein.
All pipes shall be installed as indicated on plans, any relocations required for proper execution
of other trade shall be with prior approval of the architect or engineer.
Proposed sanitary utilities shall conform to the actual location, depth and invert elevation of all
existing pipes and structure as verified by the contractor.
Refer to architectural plans for area drain, catch basin, floor drains and clean out location.
All slopes for horizontal drainage shall maintain 2% unless otherwise specified.
Size of water supply pipes to fixtures shall be in accordance with the manufacturer’s
instructions.
The contractor shall verify all existing utilities at site, coordinate the woks with the line service
connecting point unless otherwise specified.
All pipe sizes and dimensions are in millimeters unless otherwise specified.