ADVANCED MOTHER AND

CHILD CENTRE (PH-I)


AT
A B D F G H I J L CR-1 CR-2 CR-3 CR-4 CR-5 CR-6 CR-7 CR-8 CR-9 CR-10 M O P Q R S U W X
POSTGRADUATEINSTITUTE
OFMEDICALEDUCATION
111735
7180 35000 27375 35000 7180
&RESEARCH(PGIMER),
400 800 SECTOR12,CHANDIGARH
350 7000 800 4225 1275 675 4120 3500
6830 7000 7000 3500 3500 3500 3500 4800 4775 4125 1380 7000 3500 3500 3500 7000 7000 7180
NOTES :
SERVICE
BLOCK - B ENTRY 100 MM
BLOCK - C 1.
2.
3.
Dimensions on the drawings are to be read and not scaled.
All dimensions are in mm.
The Engineer in-charge (i.e the project supervising
authority) shall co-relate all working drawings and shop &

BLOOD BANK & LABS


EXPANSION
JOINT KITCHEN PANTRY ,CANTEEN& SEMINAR HALLS LIGHT/VENTILATION
fabrication drawings (prepared by contractor). Any
discrepancy is to be resolved before commencement of
work on site.
SHAFT
4. Lift pit and lift well details to be coordinated with
approved technical submittals. Any discrepancy is to be
LADIES TOILET
brought to the notice of Engineer in-charge before
350

DN
commencement of work on site.
5. Heritage items on site (if any) to be handled as per law and
UP latest guidelines / orders should not be violated.
21 21
W.C W.C W.C

1
21
6. Demolition on site is to be carried out only after approval of
W - 2150 mm
T - 300 mm
competent authority as per law.
TOILET IMMUNO R - 150 mm
NO. OF
STEPS - 28
7. All mature trees on site to be protected after due
WASHING HEMATOLOGY TTI TESTING F.H.C consultation and permission from local authorities . It should
CUM LAB LAB be ensured on site that green cover is not reduced or
SERVICE AREA
W - 2150 mm STERILE (10550 X 7235)
W - 2150 mm mutilated and latest guidelines/orders are not violated.
T - 300 mm T - 300 mm
R - 150 mm 7 14
PATIENT ATTENDENT R - 150 mm
8. The building is designed for GRIHA V rating. All building
7000

RAILING HT
DN
NO. OF STEPS - 28
24HR. EMERGENCY & ST-03 1050 MM
NO. OF STEPS - 28
DN
BLOOD CANTEEN

SERVICE COUNTER
(5950 X 6175)

OFFICE ROUTINE CROSSMATCH H.C TOI


elements to be co-related with GRIHA checklist and tender
GROUPING SECTION provisions to be issued as GFC drawings. Discrepancy if
UP LAB UP
RAILING HT
1050 MM ST - 02
JAN W.C W.C W.C
ST - 01 RAILING HT
any is to be bought to the notice of Engineer-in-charge.
(7250 x 5450) (7250 x 5450)
1050 MM 9. All services , modular OT's , Pneumatic tube stations, IT
COMPONENT STORE GENTS TOILET provisions etc to be coordinated by engineer-in-charge as
LIFT
PREP, SERVICES per tender provisions , shop & fabrication drawings
PANTR
STORAGE & (prepared by contractor),GFC drawings issued .
F.H.C LABELING LAB D/W F.H.C
10. This drawing is approved by competent technical healthcare
20 20 authority.
11. Soil, Ventilating, Services Pipes, Ducts and cables are not
17500

allowed on the exterior face of the building. All such pipes,


3500

ducts & cables should not be visible on the facade of the


building. They are to be accommodated in the shafts
ISSUE
COUNTER
provided in design.
12. The drawing is to be co-ordinated with services & structural
19 FEMALE- TOILET
UTILITY
19 drawings/ design duly approved and vetted by IIT before
adoption at site. Discrepancy if any is to be brought to the

UTILITY
notice of Consulting Architect.
3400

13. This building is to have 100% power backup


DONOR WAITING
14. Artificial lighting and ventilation is to be strictly as per

JANITOR
WC
BLEEDING ROOM & LVL +300 STAFF CANTEEN WASHING AREA
LVL +300 National Building Code & Para 10.1 (v),Page 56
APHAERESIS ROOM
SEMINAR HALL-1 CBRL-2017
SEMINAR HALL-2 15. Contractor to make all technical submittals as per tender
18 WC
DONOR
REFRESHMENT
DONOR
SCREENING
DONOR
COUNSELING SERVICES
LOCKERS
CHANGE ROOM LOCKERS
MALE 18 terms and conditions. The Engineer-in-charge to give written
ROOM ROOM approval of all technical submittals.
JANITOR MALE LAB STORES
16. The work is to executed by specialized contractors.
3600

TOILET

LIFT 17. Specialized HVAC Contractor approved by HITES as per


CPWD guidelines shall prepare all shop and fabrication
SERVICES drawings.

TOILET
CHANGE CHANGE TOILET 18. Shop and fabrication drawings are to be approved by
Engineer-in-charge/(HITES, Services team) before execution
17 17 at site.
19. No material is to be procured without written approval of
2800

LIFT CORRIDOR
SERVICES corresponding shop and fabrication drawing and technical
16 16 submittal , duly approved by Engineer-in-charge.
700

20. Work is to be carried out strictly as per CPWD Guidelines,


LVL ±0 LENGTH = 25200 MM MICROBIOLOGY LAB DECONTAMINATION tender terms and conditions and BOQ provision. any
730

2700

5230 deviation , substitution or extra work should not be executed


15 15 on site without written consent of competent authority.
21. The shop and fabrication drawings are to be made as per
SLOPE 1:12
terms of contract and CPWD specifications.
3425

400 22. This drawing is issued after discussion with the user group
14-A SLOPE- SLOPE- 14-A on 03-07-2023 regarding the recent new requirement of the
HAEMATOLOGY LAB WASHING user group for additional hand washing facilities in addition
1:10 RAILING HT 1:10
4950

F.H.C
to the already provided hand washing facilities as per HITES
1050MM
14 14 letter No. - HITES/IDN/PGIMER-CHD/2023-24/615 , dated
CLEAR HT LIFT D/W CONCRETE 24-06-2023
2800MM 00 SLOPE DN
COVERING WITH
27 BIOCHEMISTRY LAB
3575

D/W
MALE-TOILET
13-A TOILET
GLASS BRICK AND 13-A
(5200 x 7000) LANDSCAPED POLYCARBONTE
ST - 06 LIFT WC
OFFICE FEMALE
TOILET
AREA
800

WC

13 SAMPLE
LIFT
W - 2150 mm
T - 300 mm
JANITOR

13
R - 150 mm
NO. OF
4820

STEPS - 28
18228

RAMP
12 UP
DN 12
2975

LIFT 3100
C/L C/L
28000

DW4
UP
DN LVL + 600
2700

LANDING 12532 LVL +1200


LVL+3300

11 11
2425

LANDSCAPE AREA 100 MM WIDE


LVL + 1200
EXPANSION JOINT
4820

RAMP
800

DN
800

10 10
74500

TOTAL LENGHT OF RAMP 50400


28300

28300
SLOPE 1:12
9 9
2700

LIFT
LVL + 450
800

8-A 8-A
4950

CH D/W
8-B LENGTH = 25200 MM
ROOM 8-B

SLOPE- CH
ROOM
CH
ROOM
MAY I HELP YOU
3500

8 8
LOCKERS

DU
1:10 DESK DR FILE RIVEW HOSPITAL SUPERVISOR
730

TOILET ROOM ADMIN OFFICE ROOM OFFICES


CONCRETE W - 2150 mm

7-A UTILITY T - 300 mm


R - 150 mm
NO. OF STEPS - 28 7-A
COVERING WITH DN

COUNTER
TOILET
TOILET
GLASS BRICK AND SLOPE 1:12
LOCKER
AHU PHARMACY
POLYCARBONTE ST - 05
UP

RAILING HT
STORE
3500

DOCTOR ROOM
7 LVL + 450
NURSE STORE
(7250 x 5450)
1050 MM
7
NURSE ROOM

STORE
HAND WASH
F.H.C
RAMP Rev.No. REVISION RECORD DATE
6 6
IN
NEONATAL ISSUED FOR APPROVAL
3500

RESUSCITATION ULTRASOUND
ROOM ROOM
EMERGENCY
RAMP STAIRCASE PROCEDURE/

AR
W - 2150 mm
T - 300 mm
R - 150 mm
NURSE STATION
NO. OF STEPS - 28 DELIVERY ROOM

5 OUT DN ST-01
D/W FEMALE- 5
TOILET

RAILING HT
UP SCRUB WAITING AREA
1050 MM ST - 01
3500

BILLING COUNTERS
(7250 x 5450)

SECURITY / KEY DATE: APRIL, 2020


SCRUB
ROOM
SCALE:- 1:150
STERILE

STORAGE
STORAGE
WC
D/U DOCTOR STORE EMERGENCY RECEPTION
F.H.C CHANGE (9800X6130)
DOUBLE HEIGHT MALE-TOILET
SHEET TITLE:-

4 ENTRANCE 4
WC

FOYER GROUND FLOOR PLAN


17500

3500

FIRE ROOM
JANITOR
WASHING FACILITY
LVL + 1200
DRG NO:-
3 D/W
DW1 3
PGIMER/AMCC/PH-1/SSA-2019/AR-P1
1950

TOILET
WC
1050 MM HIGH 1050 MM HIGH
SS RAILING SS RAILING
2-A LVL + 1200 2-A REVISION
TRIAGE TRIAGE
WC SLR EMERGENCY 4 BEDDED
HOSPITAL 4 BEDDED 4 BEDDED DUTY ROOM DOCTOR
ROOM
ATTENDENT/SA
BATH
TROLLEY
5050

WC

BAY PUBLIC ART LANDSCAPE AREA SIGNATURE


WHEEL CHAIR
FRONT ENTRANCE PGIMER
BAY
350
350

BATH
16676 MM WIDE
TOILET

WC

2 2
SIGNATURE
AMBULANCE
DROP OFF BLOCK - D HITES INFRA TECH SERVICES LTD. / CONSULTANT

POSTGRADUATE INSTITUTE OF
MEDICAL EDUCATION & RESEARCH
ADMINISTRATION (PGIMER),
9000

9000

BLOCK - A SECTOR 12 , CHANDIGARH

HITES INFRA TECH SERVICES LTD.


PORCH
EMERGENCY (26475 MM X 9000 MM ) ( A Government of India Enterprise)
INFRASTRUCTURE DEVELOPMENT DIVISION
NOIDA - 201307
1 1
SURINDER SAWHNEY ASSOCIATES
ARCHITECTS & DESIGN CONSULTANTS
#571, SECTOR-18B, CHANDIGARH.160018
PH.:0172-2780535.FAX: 0172-2726627
E-MAIL:surindersawhney571@gmail.com

THIS DRAWING IS COPYRIGHT.