You are on page 1of 22

Figure 24-1

Cast-Iron Pipe Joints.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-2
Copper Pipe Fittings.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-3
Solder Fittings.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-4
Adapters—Copper Tube to Threaded Pipe.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-5
Screwed Fittings.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-6
Butt-Welded Fittings.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-7
Flanged Fittings.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-8
Designating Sizes of Fittings.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-9
Special Types of Flanged Joints.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-10
Welded Joints.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-11
Gate, Globe, and Check Valves.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Fiure 24-12
Piping Symbols.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-13
Representations of Pipe Expansion Joint.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-14
Pipe Grids and Serpentine Coils for a Panel Radiant Heating System.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-15
Schematic Drawing of Piping Connecting
Boiler to Heating Coils.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-16
A One-Pipe Steam Heating System.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-17
A Two-Line Piping Drawing for a Pumping Plant.
© 2003, Prentice-Hall, Inc.
Giesecke
Technical Drawing, 12e
Figure 24-18
A Dimensioned Piping Drawing—Side View of Steam Piping.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-19
3D Piping Drawing Produced on a CAD System.
Courtesy of SolidWorks Corporation.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-20
Piping System Drawing Produced with the VersaCAD Advanced
Drafting Software Package. Courtesy of VersaCAD.

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-21
Pipe Layout for Battery of Air Receivers (Probs. 24.5 and 24.7).

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e
Figure 24-22
Isometric Pipe Layout (Probs. 24.6 and 24.8).

© 2003, Prentice-Hall, Inc.


Giesecke
Technical Drawing, 12e

You might also like