13 AS/NZS 1477:2017

TABLE 3.2
TEST MASSES FOR 20°C IMPACT TEST
Nominal size Total mass Nominal size Total mass Nominal size Total mass
DN kg DN kg DN kg
10 0.5 50 1.75 175 3.75
15 0.75 65 2.00 200 5.00
20 1.00 80 2.25 225 5.75
25 1.25 100 2.75 250 6.25
32 1.38 125 3.25 300 7.50
40 1.5 150 3.50 and above —
NOTE: The tolerance on mass shall be +0.05, 0 kg.

TABLE 3.3
MAXIMUM NUMBER OF IMPACTS
PER SPECIMEN FOR 20°C IMPACT TEST
Nominal size Maximum number of impacts
DN per specimen
<50 1
50 3
65 3
80 4
100 6
125 8
Accessed by FLETCHER BUILDING on 28 Feb 2018 (Document currency not guaranteed when printed)

150 8
175 10
200 12
225 14
250 16
300 20

3.3.3 Reversion test


When determined in accordance with AS/NZS 1462.4, the reversion of the pipe shall not
exceed 5.0%, nor shall the pipe show any signs of cracks, cavities or blisters resulting from
the immersion.
3.3.4 High temperature test
When tested at 180°C in accordance with AS/NZS 1462.16, pipes shall not show any splits,
delamination, porosity or inclusions.
NOTE: Absorbed water can affect results and, hence, caution is to be used when applying this test
to pipes that have been stored or used in service.
3.3.5 Fracture toughness test (only applicable to pipes DN 80 and Tmin 4.0 mm)
When tested in accordance with AS/NZS 1462.19, pipes shall exhibit a fracture toughness
(KIc) value of not less than that determined by the following equation:
KIc = 0.09σy . . . 3.3
Where σy is the 15 min yield strength obtained from the testing of pipes in accordance with
AS/NZS 1462.6 or in accordance with AS/NZS 1462.19.