You are on page 1of 52

Date

Well No
(MM/DD/YYYY)
3-Aug-19 06B-057
4-Aug-19 04B-082
4-Aug-19 03B-022
4-Aug-19 06B-107
4-Aug-19 09B-109
4-Aug-19 13B-004
4-Aug-19 13B-079
4-Aug-19 14B-005
4-Aug-19 12B-126
6-Aug-19 07B-135
7-Aug-19 03B-022
7-Aug-19 03B-023
7-Aug-19 03B-024
7-Aug-19 03B-025
7-Aug-19 03B-071
7-Aug-19 03B-072
7-Aug-19 03B-127
7-Aug-19 03B-129
8-Aug-19 04B-036
8-Aug-19 04B-038
8-Aug-19 04B-081
8-Aug-19 04B-082
8-Aug-19 04B-083
8-Aug-19 04B-111
8-Aug-19 04B-174
8-Aug-19 04B-176
8-Aug-19 04B-177
8-Aug-19 04B-182
10-Aug-19 03B-022
10-Aug-19 09B-109
10-Aug-19 14B-005
10-Aug-19 13B-004
10-Aug-19 13B-079
11-Aug-19 13B-078
11-Aug-19 06B-107
11-Aug-19 09B-109
11-Aug-19 13B-004
11-Aug-19 14B-005
14-Aug-19 06B-056
15-Aug-19 01B-014
15-Aug-19 01B-015
15-Aug-19 01B-018
15-Aug-19 01B-070

# Sensitivity: Internal (C3)


15-Aug-19 01B-101
15-Aug-19 01B-142
15-Aug-19 01B-179
15-Aug-19 01B-181
15-Aug-19 02B-030
15-Aug-19 02B-086
15-Aug-19 02B-119
15-Aug-19 02B-121
15-Aug-19 03B-022
15-Aug-19 03B-023
15-Aug-19 03B-024
15-Aug-19 03B-025
15-Aug-19 03B-071
15-Aug-19 03B-072
15-Aug-19 03B-127
15-Aug-19 03B-129
15-Aug-19 03B-133
15-Aug-19 04B-036
15-Aug-19 04B-038
15-Aug-19 04B-081
15-Aug-19 04B-082
15-Aug-19 04B-083
15-Aug-19 04B-111
15-Aug-19 04B-174
15-Aug-19 04B-176
15-Aug-19 04B-177
15-Aug-19 04B-182
15-Aug-19 05B-043
15-Aug-19 05B-154
15-Aug-19 05B-163
15-Aug-19 06B-054
15-Aug-19 06B-055
15-Aug-19 06B-056
15-Aug-19 06B-057
15-Aug-19 06B-107
15-Aug-19 06B-110
15-Aug-19 06B-122
15-Aug-19 06B-132
15-Aug-19 06B-134
15-Aug-19 06B-171
15-Aug-19 07B-135
15-Aug-19 08B-150
15-Aug-19 09B-067
15-Aug-19 09B-094
15-Aug-19 09B-095

# Sensitivity: Internal (C3)


15-Aug-19 09B-108
15-Aug-19 09B-109
15-Aug-19 10B-091
15-Aug-19 10B-092
15-Aug-19 10B-123
15-Aug-19 11B-066
15-Aug-19 12B-124
15-Aug-19 12B-126
15-Aug-19 12B-128
15-Aug-19 12B-138
15-Aug-19 13B-004
15-Aug-19 13B-033
15-Aug-19 13B-076
15-Aug-19 13B-078
15-Aug-19 13B-079
15-Aug-19 13B-080
15-Aug-19 13B-089
15-Aug-19 13B-090
15-Aug-19 13B-115
15-Aug-19 13B-136
15-Aug-19 13B-162
15-Aug-19 13B-169
15-Aug-19 14B-005
15-Aug-19 14B-098
15-Aug-19 14B-112
15-Aug-19 14B-114
15-Aug-19 14B-117
15-Aug-19 14B-155
15-Aug-19 14B-167
15-Aug-19 15B-012
15-Aug-19 15B-013
15-Aug-19 15B-164
17-Aug-19 11B-1ST
18-Aug-19 09B-069
22-Aug-19 13B-033
22-Aug-19 13B-076
22-Aug-19 13B-078
22-Aug-19 13B-080
22-Aug-19 13B-089
22-Aug-19 13B-090
22-Aug-19 13B-136
22-Aug-19 13B-162
22-Aug-19 13B-169
25-Aug-19 01B-070
25-Aug-19 02B-030

# Sensitivity: Internal (C3)


25-Aug-19 02B-086
25-Aug-19 02B-119
25-Aug-19 02B-121
26-Aug-19 05B-163
27-Aug-19 01B-014
27-Aug-19 01B-018
27-Aug-19 01B-101
27-Aug-19 01B-142
27-Aug-19 03B-023
27-Aug-19 03B-024
27-Aug-19 03B-025
27-Aug-19 03B-129
27-Aug-19 03B-133
27-Aug-19 04B-081
27-Aug-19 04B-111
27-Aug-19 06B-110
27-Aug-19 06B-122
27-Aug-19 06B-132
27-Aug-19 06B-134
27-Aug-19 07B-135
27-Aug-19 08B-150
27-Aug-19 09B-067
27-Aug-19 09B-094
27-Aug-19 10B-123
27-Aug-19 11B-066
27-Aug-19 12B-124
27-Aug-19 12B-128
27-Aug-19 12B-138
27-Aug-19 13B-078
27-Aug-19 13B-089
27-Aug-19 13B-136
27-Aug-19 14B-098
27-Aug-19 14B-112
27-Aug-19 14B-155
27-Aug-19 15B-013
28-Aug-19 03B-022
28-Aug-19 03B-023
28-Aug-19 03B-024
28-Aug-19 03B-025
28-Aug-19 03B-071
28-Aug-19 03B-072
28-Aug-19 03B-127
28-Aug-19 03B-129
28-Aug-19 03B-133
29-Aug-19 03B-023

# Sensitivity: Internal (C3)


30-Aug-19 02B-121
30-Aug-19 13B-090
31-Aug-19 01B-101
31-Aug-19 01B-014
31-Aug-19 02B-023
31-Aug-19 03B-024
31-Aug-19 02B-071
31-Aug-19 03B-072
31-Aug-19 07B-135
31-Aug-19 09B-094
31-Aug-19 10B-123
31-Aug-19 11B-1ST
31-Aug-19 11B-066
31-Aug-19 13B-089
31-Aug-19 14B-098
31-Aug-19 15B-013
31-Aug-19 14B-167
1-Sep-19 07B-135
1-Sep-19 03B-185
2-Sep-19 03B-071
3-Sep-19 13B-090

4-Sep-19 09B-109

4-Sep-19 14B-005

4-Sep-19 07B-135

5-Sep-19 09B-109

5-Sep-19 14B-005

6-Sep-19 03B-186
7-Sep-19
7-Sep-19 02B-030
7-Sep-19 02B-086
7-Sep-19 02B-119
7-Sep-19 02B-121
8-Sep-19 02B-030
8-Sep-19 02B-086
8-Sep-19 02B-119
8-Sep-19 13B-162
10-Sep-19 13B-089
10-Sep-19 09B-067
11-Sep-19 03B-022
11-Sep-19 03B-022
11-Sep-19 04B-082

# Sensitivity: Internal (C3)


11-Sep-19 09B-109
11-Sep-19 13B-004
11-Sep-19 13B-079
11-Sep-19 14B-005
11-Sep-19 13B-089
12-Sep-19 01B-142
13-Sep-19 09B-067
13-Sep-19 15B-011
14-Sep-19 13B-078
15-Sep-19 13B-078
19-Sep-19 13B-078
20-Sep-19 01B-014
20-Sep-19 01B-015
20-Sep-19 01B-018
20-Sep-19 01B-070
20-Sep-19 01B-179
20-Sep-19 01B-181
20-Sep-19 02B-030
20-Sep-19 02B-086
20-Sep-19 02B-119
20-Sep-19 02B-121
20-Sep-19 03B-022
20-Sep-19 03B-023
20-Sep-19 03B-024
20-Sep-19 03B-025
20-Sep-19 03B-072
20-Sep-19 03B-127
20-Sep-19 03B-129
20-Sep-19 03B-186
20-Sep-19 04B-036
20-Sep-19 04B-038
20-Sep-19 04B-040
20-Sep-19 04B-081
20-Sep-19 04B-082
20-Sep-19 04B-083
20-Sep-19 04B-111
20-Sep-19 04B-174
20-Sep-19 04B-177
20-Sep-19 04B-182
20-Sep-19 05B-043
20-Sep-19 05B-154
20-Sep-19 05B-163
20-Sep-19 06B-054

# Sensitivity: Internal (C3)


20-Sep-19 06B-055
20-Sep-19 06B-056
20-Sep-19 06B-057
20-Sep-19 06B-107
20-Sep-19 06B-110
20-Sep-19 06B-122
20-Sep-19 06B-132
20-Sep-19 06B-134
20-Sep-19 06B-171
20-Sep-19 07B-135
20-Sep-19 08B-150
20-Sep-19 09B-067
20-Sep-19 09B-069
20-Sep-19 09B-094
20-Sep-19 09B-095
20-Sep-19 09B-108
20-Sep-19 09B-109
20-Sep-19 10B-091
20-Sep-19 10B-092
20-Sep-19 10B-123
20-Sep-19 11B-066
20-Sep-19 11B-1ST
20-Sep-19 12B-124
20-Sep-19 12B-126
20-Sep-19 12B-128
20-Sep-19 12B-138
20-Sep-19 13B-004
20-Sep-19 13B-033
20-Sep-19 13B-076
20-Sep-19 13B-079
20-Sep-19 13B-080
20-Sep-19 13B-090
20-Sep-19 13B-115
20-Sep-19 13B-136
20-Sep-19 13B-169
20-Sep-19 13B-188
20-Sep-19 14B-005
20-Sep-19 14B-098
20-Sep-19 14B-112
20-Sep-19 14B-114
20-Sep-19 14B-117
20-Sep-19 14B-155
20-Sep-19 14B-167

# Sensitivity: Internal (C3)


20-Sep-19 15B-011
20-Sep-19 15B-012
20-Sep-19 15B-013
20-Sep-19 15B-164
21-Sep-19 13B-089
22-Sep-19 03B-185
22-Sep-19 01B-070
22-Sep-19 04B-177
22-Sep-19 01B-179
22-Sep-19 04B-083
22-Sep-19 09B-108
22-Sep-19 01B-014
22-Sep-19 06B-171
25-Sep-19 01B-014
25-Sep-19 01B-015
25-Sep-19 01B-070
25-Sep-19 01B-179
25-Sep-19 01B-181
25-Sep-19 02B-030
25-Sep-19 02B-086
25-Sep-19 02B-119
25-Sep-19 02B-121
25-Sep-19 03B-022
25-Sep-19 03B-023
25-Sep-19 03B-024
25-Sep-19 03B-025
25-Sep-19 03B-072
25-Sep-19 03B-127
25-Sep-19 03B-129
25-Sep-19 03B-186
25-Sep-19 04B-036
25-Sep-19 04B-038
25-Sep-19 04B-040
25-Sep-19 04B-081
25-Sep-19 04B-082
25-Sep-19 04B-083
25-Sep-19 04B-111
25-Sep-19 04B-174
25-Sep-19 04B-177
25-Sep-19 04B-182
25-Sep-19 05B-043
25-Sep-19 05B-154
25-Sep-19 05B-163

# Sensitivity: Internal (C3)


25-Sep-19 06B-054
25-Sep-19 06B-055
25-Sep-19 06B-056
25-Sep-19 06B-057
25-Sep-19 06B-107
25-Sep-19 06B-110
25-Sep-19 06B-122
25-Sep-19 06B-132
25-Sep-19 06B-134
25-Sep-19 06B-171
25-Sep-19 07B-135
25-Sep-19 08B-150
25-Sep-19 09B-067
25-Sep-19 09B-069
25-Sep-19 09B-094
25-Sep-19 09B-095
25-Sep-19 09B-108
25-Sep-19 09B-109
25-Sep-19 10B-091
25-Sep-19 10B-092
25-Sep-19 10B-123
25-Sep-19 11B-066
25-Sep-19 11B-1ST
25-Sep-19 12B-124
25-Sep-19 12B-126
25-Sep-19 12B-128
25-Sep-19 12B-138
25-Sep-19 13B-004
25-Sep-19 13B-033
25-Sep-19 13B-076
25-Sep-19 13B-079
25-Sep-19 13B-080
25-Sep-19 13B-090
25-Sep-19 13B-115
25-Sep-19 13B-136
25-Sep-19 13B-169
25-Sep-19 13B-188
25-Sep-19 14B-005
25-Sep-19 14B-098
25-Sep-19 14B-112
25-Sep-19 14B-114
25-Sep-19 14B-117
25-Sep-19 14B-155

# Sensitivity: Internal (C3)


25-Sep-19 14B-167
25-Sep-19 15B-011
25-Sep-19 15B-012
25-Sep-19 15B-013
25-Sep-19 15B-164
27-Sep-19 01B-101
27-Sep-19 01B-014
27-Sep-19 03B-023
27-Sep-19 03B-025
27-Sep-19 09B-094
27-Sep-19 11B-066
27-Sep-19 14B-098
27-Sep-19 03B-022
27-Sep-19 04B-082
27-Sep-19 06B-056
27-Sep-19 06B-107
27-Sep-19 09B-109
27-Sep-19 13B-004
27-Sep-19 13B-079
27-Sep-19 14B-005

# Sensitivity: Internal (C3)


Remarks

Well started post workover


SI to maintain 24" PF departure pressure & to avoid reaching tripping pressure during 24" PF pigging
SI to maintain 24" PF departure pressure & to avoid reaching tripping pressure during 24" PF pigging
SI to maintain 24" PF departure pressure & to avoid reaching tripping pressure during 24" PF pigging
SI to maintain 24" PF departure pressure & to avoid reaching tripping pressure during 24" PF pigging
SI to maintain 24" PF departure pressure & to avoid reaching tripping pressure during 24" PF pigging
SI to maintain 24" PF departure pressure & to avoid reaching tripping pressure during 24" PF pigging
SI to maintain 24" PF departure pressure & to avoid reaching tripping pressure during 24" PF pigging
Started post IPCP changeout
Started post workover
ESD-1 activiated due to F&G alarm in UT0001
ESD-1 activiated due to F&G alarm in UT0001
ESD-1 activiated due to F&G alarm in UT0001
ESD-1 activiated due to F&G alarm in UT0001
ESD-1 activiated due to F&G alarm in UT0001
ESD-1 activiated due to F&G alarm in UT0001
ESD-1 activiated due to F&G alarm in UT0001
ESD-1 activiated due to F&G alarm in UT0001
PSIT 0010 failure
PSIT 0010 failure
PSIT 0010 failure
PSIT 0010 failure
PSIT 0010 failure
PSIT 0010 failure
PSIT 0010 failure
PSIT 0010 failure
PSIT 0010 failure
PSIT 0010 failure
MPP-C maintenance
MPP-C maintenance
MPP-C maintenance
MPP-C maintenance
MPP-C maintenance
Started post RRU troubleshooting
MPP-B maintenance
MPP-B maintenance
MPP-B maintenance
MPP-B maintenance
New Conversion well started
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL

# Sensitivity: Internal (C3)


PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL, VFD Troubleshooting
Jet Pump, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
Jet Pump, OHL, Globe Valve Maintenance
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
Jet Pump, OHL
PCP, OHL
Jet Pump, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL

# Sensitivity: Internal (C3)


PCP, OHL
Jet Pump, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
Jet Pump, OHL
PCP, OHL
PCP, OHL
PCP, OHL
Jet Pump, OHL
PCP, OHL
PCP, OHL, Troubleshooting
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
Jet Pump, Well head greasing and IPM, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
PCP, OHL
Post Workover
Started Post Workover
PMCC incomer ACB tripped on earth fault during B-188 pre-commissioning checks was being carried
PMCC incomer ACB tripped on earth fault during B-188 pre-commissioning checks was being carried
PMCC incomer ACB tripped on earth fault during B-188 pre-commissioning checks was being carried
PMCC incomer ACB tripped on earth fault during B-188 pre-commissioning checks was being carried
PMCC incomer ACB tripped on earth fault during B-188 pre-commissioning checks was being carried
PMCC incomer ACB tripped on earth fault during B-188 pre-commissioning checks was being carried
PMCC incomer ACB tripped on earth fault during B-188 pre-commissioning checks was being carried
PMCC incomer ACB tripped on earth fault during B-188 pre-commissioning checks was being carried
PMCC incomer ACB tripped on earth fault during B-188 pre-commissioning checks was being carried
Started post RRU operation, Motor troubleshooting.
Power failure at BWP02, Investigation in-progress.

# Sensitivity: Internal (C3)


Power failure at BWP02, Investigation in-progress.
Power failure at BWP02, Investigation in-progress.
Power failure at BWP02, Investigation in-progress.
Started post workover
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Power dip from MPT
Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility

# Sensitivity: Internal (C3)


RRU troubleshooting
THP dropped, no build up.
Trip, Bus Overvoltage, No THP Build Up
Tripped due to Power dip
Tripped due to Power dip
Tripped due to Power dip
Tripped due to Power dip
Tripped due to Power dip
Tripped due to Power dip
Tripped due to Power dip
Tripped due to Power dip
Tripped due to Power dip
Tripped due to Power dip
Tripped due to Power dip
Tripped due to Power dip
Tripped due to Power dip
Tripped due to Power dip
BWP07 started on DG
New well commissioned
Tripped on "Bus Overvoltage", no THP/rod torque build up after closing globe valve
Started post RRU troubleshooting

18" Corridor-B pig launcher downstream line sleeve welding (due to wall thickness~<2mm during IP run)

18" Corridor-B pig launcher downstream line sleeve welding (due to wall thickness~<2mm during IP run)

DG power to OHL power switch over post RMU to transformer (33 KV) terminal rectification

18" Corridor-B pig launcher downstream line sleeve welding (due to wall thickness~<2mm during IP run)

18" Corridor-B pig launcher downstream line sleeve welding (due to wall thickness~<2mm during IP run)

New well commissioned


All producers got tripped, due to MPT to Bhagyam OHL trip on bird hit
Power failure due to UPS issue
Power failure due to UPS issue
Power failure due to UPS issue
Power failure due to UPS issue, tripping on "high torque"
Power fluctuation in Controller
Power fluctuation in Controller
Power fluctuation in Controller
No THP build-up, discussed with ALS & Well was SI
Trip, Bus Overvoltage, No THP Build Up
Shut In,No THP Build Observed
24" trunk ine PF pigging, to avoid back pressure during pigging (Jet pump)
24" trunk ine PF pigging, to avoid back pressure during pigging (Jet pump)
24" trunk ine PF pigging, to avoid back pressure during pigging (Jet pump)

# Sensitivity: Internal (C3)


24" trunk ine PF pigging, to avoid back pressure during pigging (Jet pump)
24" trunk ine PF pigging, to avoid back pressure during pigging (Jet pump)
24" trunk ine PF pigging, to avoid back pressure during pigging (Jet pump)
24" trunk ine PF pigging, to avoid back pressure during pigging (Jet pump)
Started post RRU operation
For RRU troubleshooting (Zero rate reported in MPFM & THP=production header pressure)
Lined-up post RRU troubleshooting
Lined-up post Workover
Well shut post THP build up test
Post RRU
Tripped on Bus over voltage
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure

# Sensitivity: Internal (C3)


Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure

# Sensitivity: Internal (C3)


Power Failure
Power Failure
Power Failure
Power Failure
Lined-up post RRU troubleshooting
Post motor replacement
MPP-B Tripped
MPP-B Tripped
MPP-B Tripped
MPP-B Tripped
MPP-B Tripped
MPP-B Tripped
MPP-B Tripped
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure

# Sensitivity: Internal (C3)


Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure, Tripped on "High alaram"
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure, Tripped on "Bus reg tol vel" and started back
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Power Failure

# Sensitivity: Internal (C3)


Power Failure
Power Failure
Power Failure
Power Failure
Power Failure
Post RRU Troubleshooting
tripped "bus under voltage", Normalized - Grid failure at MPT
tripped "bus under voltage", Normalized - Grid failure at MPT
tripped "bus under voltage", Normalized - Grid failure at MPT
tripped "bus under voltage", Normalized - Grid failure at MPT
tripped "bus under voltage", Normalized - Grid failure at MPT
tripped "bus under voltage", Normalized - Grid failure at MPT
tripped "bus under voltage", Normalized - Grid failure at MPT
tripped "bus under voltage", Normalized - Grid failure at MPT
tripped "bus under voltage", Normalized - Grid failure at MPT
tripped "bus under voltage", Normalized - Grid failure at MPT
tripped "bus under voltage", Normalized - Grid failure at MPT
tripped "bus under voltage", Normalized - Grid failure at MPT
tripped "bus under voltage", Normalized - Grid failure at MPT
tripped "bus under voltage", Normalized - Grid failure at MPT

# Sensitivity: Internal (C3)


Ramp Down Start Time Shut-In Time Start-Up Time Ramp Up Complete Time

- - 0:28
9:55 19:20
10:00 18:55
9:55 21:30
10:20 21:30
10:10 18:12
10:08 18:54
9:58 18:44
16:20
23:00
8:19 9:05
8:19 8:57
8:19 8:57
8:19 8:57
8:19 8:58
8:19 8:55
8:19 8:49
8:19 9:00
3:10 4:15
3:10 4:15
3:10 4:15
3:10 4:15
3:10 4:15
3:10 4:15
3:10 4:20
3:10 4:20
3:10 4:20
3:10 4:20
13:45 15:17
13:40 17:00
13:24 19:10
13:30 16:15
13:30 14:15
3:15
13:15 21:06
13:15 20:48
13:15 21:17
13:15
2:40
18:10
18:10
18:10
18:10

# Sensitivity: Internal (C3)


18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10

# Sensitivity: Internal (C3)


18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
15:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
18:10
23:00
1:30
10:58 11:45
10:58 11:45
10:58 11:45
10:58 11:45
10:58 11:45
10:58 11:45
10:58 11:45
10:58 13:56
10:58 11:45
17:45
23:55 1:10

# Sensitivity: Internal (C3)


23:55 1:10
23:55 1:10
23:55 1:10
22:00
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 12:30
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 15:15
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 15:00
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
10:49 11:40
7:30 17:00
7:30
7:30 17:00
7:30 17:00
7:30 17:00
7:30 17:00
7:30 17:00
7:30 17:00
7:30 17:00
1:00

# Sensitivity: Internal (C3)


14:05
22:50
4:50
12:04
12:04
12:04
12:04
12:04
12:04
12:04
12:04
12:04
12:04
12:04
12:04
12:04
12:04
11:25
16:00
22:25
1:30

10:15

10:15

9:00 9:10

16:10

16:10

16:57
5:38
21:30 23:40
21:30 23:40
21:30 23:40
21:30
11:04 15:20
11:04 15:20
11:04 15:20
14:27
- 5:20 - -
- 7:00 - -
14:00 16:15
17:32 21:30
13:45 22:15

# Sensitivity: Internal (C3)


13:15 21:30
13:15 21:30
14:15 21:10
13:30 21:25
23:15
15:00
3:00
7:40
1:55
6:38
1:00
1:20 12:30
1:20 12:30
1:20 12:30
1:20 12:30
1:20 12:30
1:20 12:30
1:20 13:02
1:20 13:02
1:20 13:02
1:20 13:02
1:20 12:29
1:20 12:29
1:20 12:29
1:20 12:29
1:20 12:29
1:20 12:29
1:20 12:29
1:20 12:29
1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:15
1:20 15:03
1:20 15:03
1:20 15:03
1:20 13:15

# Sensitivity: Internal (C3)


1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:15
1:20 13:00
1:20 16:30
1:20 14:15
1:20 14:15
1:20 14:15
1:20 14:15
1:20 14:15
1:20 14:15
1:20 18:00
1:20 18:00
1:20 18:00
1:20 16:00
1:20 16:00
1:20 12:00
1:20 12:00
1:20 12:00
1:20 12:00
1:20 14:00
1:20 14:00
1:20 14:00
1:20 14:00
1:20 14:00
1:20 14:00
1:20 14:00
1:20 14:00
1:20 14:00
1:20 14:00
1:20 20:00
1:20 20:00
1:20 20:00
1:20 20:00
1:20 20:00
1:20 20:00
1:20 20:00

# Sensitivity: Internal (C3)


1:20 12:00
1:20 12:00
1:20 12:00
1:20 12:00
18:30
3:00
14:30 19:00
14:30 15:30
14:30 15:30
14:30 15:30
14:30 15:30
14:30 15:30
14:30 15:30
19:57 21:50
19:57 21:50
19:57 21:50
19:57 21:50
19:57 21:50
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:18
19:57 22:18
19:57 22:18
19:57 22:18
19:57 22:18
19:57 22:18
19:57 22:18
19:57 22:18
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:30
19:57 22:30
19:57 22:30

# Sensitivity: Internal (C3)


19:57 22:30
19:57 22:30
19:57 22:30
19:57 22:30
19:57 22:30
19:57
19:57 22:30
19:57 22:30
19:57 22:30
19:57 22:30
19:57 22:30
19:57 22:30
19:57 22:30
19:57 22:30
19:57 22:30
19:57 22:30
19:57 22:30
19:57 22:30
19:57 23:00
19:57 22:00
19:57 22:00
19:57 22:30
19:57 22:30
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 22:00
19:57 21:45
19:57 21:45
19:57 21:45
19:57 21:45
19:57 21:45
19:57 21:45

# Sensitivity: Internal (C3)


19:57 21:45
19:57 21:27
19:57 21:27
19:57 21:27
19:57 21:27
16:45
19:30 22:10
19:30 21:45
19:30 21:50
19:30 21:40
19:30 21:45
19:30 21:55
20:00 15:00
20:00 15:00
20:00 15:00
20:00 15:00
20:00 15:00
20:00 15:00
20:00 15:00
20:00 15:00

# Sensitivity: Internal (C3)


Date
Well No Shut In Time Start Up Time Downtime
(MM/DD/YYYY)
7-Aug-19 13B-088 18:30
7-Aug-19 13B-113 18:30
9-Aug-19 13B-118
13-Aug-19 13B-118 12:00 18:50
13-Aug-19 03B-073 12:00 18:50
13-Aug-19 03B-131 12:00 18:50
13-Aug-19 03B-158 12:00 18:50
13-Aug-19 03B-125 12:00 18:50
13-Aug-19 13B-088 12:00 18:50
13-Aug-19 13B-113 12:00 18:50
14-Aug-19 03B-073 6:00
14-Aug-19 03B-131 6:00
14-Aug-19 03B-158 6:00
14-Aug-19 03B-125 6:00
14-Aug-19 13B-088 6:00
14-Aug-19 13B-113 6:00
14-Aug-19 13B-118 6:00
19-Aug-19 03B-073 13:45
19-Aug-19 03B-131 13:45
19-Aug-19 03B-158 13:45
19-Aug-19 03B-125 13:45
19-Aug-19 13B-088 14:10
19-Aug-19 13B-113 14:10
19-Aug-19 13B-118 14:10
3-Sep-19 13B-113 23:30
6-Sep-19 13B-113 19:30
28-Sep-19 13B-088 4:15
29-Sep-19 03B-073 0:30
29-Sep-19 03B-125 0:30
29-Sep-19 03B-131 0:30
29-Sep-19 03B-158 0:30
29-Sep-19 13B-118 0:30 2:45

# Sensitivity: Internal (C3)


# Sensitivity: Internal (C3)
# Sensitivity: Internal (C3)
Remarks

P-202 Pump attended


P-202 Pump attended
To facilitate 15B-11 REPL-14 troubleshooting
Leak observed from top of Maturation tank, Leak attended
Leak observed from top of Maturation tank,Leak attended
Leak observed from top of Maturation tank, Leak attended
Leak observed from top of Maturation tank, Leak attended
Leak observed from top of Maturation tank, Leak attended
Leak observed from top of Maturation tank, Leak attended
Leak observed from top of Maturation tank, Leak attended
Leak observed from top of Maturation tank
Leak observed from top of Maturation tank
Leak observed from top of Maturation tank
Leak observed from top of Maturation tank
Leak observed from top of Maturation tank
Leak observed from top of Maturation tank
Leak observed from top of Maturation tank
PSU started post troubleshooting
PSU started post troubleshooting
PSU started post troubleshooting
PSU started post troubleshooting
PSU started post troubleshooting
PSU started post troubleshooting
PSU started post troubleshooting
LSCV stem broken
LSCV stem broken, swapped from B-137 & started
LSCV gland leak
Well intervention for B-133, B-023 & B-025
Well intervention for B-133, B-023 & B-025
Well intervention for B-133, B-023 & B-025
Well intervention for B-133, B-023 & B-025
Well intervention for B-133, B-023 & B-025

# Sensitivity: Internal (C3)


# Sensitivity: Internal (C3)
# Sensitivity: Internal (C3)
# Sensitivity: Internal (C3)
Date
Well No Shut In Time Start Up Time Difference
(MM/DD/YYYY)
26-Aug-19 10B-074 18:15
28-Aug-19 03B-073 7:50 17:30
28-Aug-19 03B-131 7:50 18:30
28-Aug-19 03B-158 7:50 17:30
28-Aug-19 03B-125 7:50 17:30
28-Aug-19 13B-088 7:50 19:00
28-Aug-19 13B-113 7:50 19:00
28-Aug-19 13B-118 7:50
25-Sep-19 11B-065 13:00
30-Sep-19 07B-060 14:00
30-Sep-19 01B-183 16:00
30-Sep-19 01B-184 17:45

# Sensitivity: Internal (C3)


Remarks

Lined up post casing patch retrieval


Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility, XSV1110 air leak for SOV
Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility
Wellpad shutdown for PCS/ESD controller upgrade for new facility XSV1181 air leak for SOV
No injectivity
Post Sand scouring job
New Well Commissioned
New Well Commissioned

# Sensitivity: Internal (C3)


Date MPP Shut started
1-Aug-19 MPP-E 20:15

8-Aug-19 MPP-A 9:30


9-Aug-19 MPP-E 9:35 16:35

9-Aug-19 MPP-A 16:30

10-Aug-19 MPP-C 13:35 19:00


11-Aug-19 MPP-B 13:23

# Sensitivity: Internal (C3)


comments
Started post mechanical troubleshooting; no foaming observed

VFD Electical PM
VFD Electical PM

VFD Electical PM of E , to makeup suction pressure A started

Shut for PMCC PM job


Shut for PMCC PM job

# Sensitivity: Internal (C3)


5-Aug-19
15-Aug-19
16-Aug-19
16-Aug-19
18-Aug-19
18-Aug-19
23-Aug-19
28-Aug-19
31-Aug-19
7-Sep-19
16-Sep-19
16-Sep-19
18-Sep-19
19-Sep-19
26-Sep-19
30-Sep-19
1-Oct-19
1-Oct-19

# Sensitivity: Internal (C3)


HP pump got trippped on high flow, started back at 08:35 hrs.
PWRI shut in at 18:10 due to OHL Trip
PWRI started at 07:30 AM
PWRI shut in at 13:05 hrs.
PWRI tripped at 11:15 and started back at 11:45 due to High discharge flow
PWRI tripped at 15:40 and started back at 16:10 due to High discharge flow
PWRI tripped at 06:10 and started back at 07:20 due to High discharge flow
PWRI tripped at 08:50 and started back at 10:00 due to High discharge flow
PWRI tripped at 03:00 and started back at 03:30 due to High discharge flow
PWRI tripped due to MPT to Bhagyam OHL trip on bird hit
PWRI tripped at 09:02 and started back at 09:20 due to High discharge flow
PWRI tripped at 09:02 and started back at 09:18 due to High discharge flow
PWRI tripped at 10:53 and started back at 11:00 due to High discharge flow
PWRI tripped at 07:30 and started back at 09:00 due to High discharge flow
PWRI tripped at 19:57 due to power failure
PWRI tripped at 16:43 hrs due to low suction pressure, Suction strainer chocked, started back at 19:22 hrs
PWRI tripped at 08:00 hrs due to Low depurator level and strted back at 11:30 hrs.
PWRI tripped at 20:22 hrs at high discharge flow and started back at 20:50

# Sensitivity: Internal (C3)


Production date

8/1/2019

8/2/2019

8/3/2019

8/4/2019

8/5/2019

8/6/2019

8/7/2019

8/8/2019

8/9/2019

8/10/2019

8/11/2019
8/12/2019

8/13/2019
8/14/2019
8/15/2019

8/16/2019
8/17/2019
8/18/2019

# Sensitivity: Internal (C3)


8/19/2019

8/20/2019

8/21/2019

8/22/2019

8/23/2019

8/24/2019

8/25/2019

8/26/2019

8/27/2019
8/28/2019
8/29/2019

8/30/2019
8/31/2019
9/1/2019

9/2/2019
9/3/2019

9/4/2019

9/5/2019
9/6/2019
9/7/2019

9/8/2019

9/9/2019

9/10/2019

9/11/2019

9/12/2019

# Sensitivity: Internal (C3)


9/13/2019
9/14/2019
9/15/2019
9/16/2019
9/17/2019

9/18/2019

9/19/2019

9/20/2019
9/21/2019

9/22/2019
9/23/2019

9/24/2019
9/25/2019

9/26/2019

9/27/2019

9/28/2019

9/29/2019

9/30/2019

# Sensitivity: Internal (C3)


WellServiceActivities

BP03: B-026 IW 80 bbls KCL pumping completed. Well under observation. BP03: B-187 JP
assisted flow back in progress. BP04: B-034 IW SIHBP completed. BP06: B-172/173 JP assisted
flowback completed. BP10: B-074 IW HUD completed at 935 MWL. BP14: B-005 JP Sand
scouring job completed and well taken in-line. BP14: B-165 JP assisted flow back in progress
through B-166 flow arm.

BP03: B-187 JP assisted flow back in progress. BP04: B-035 IW SIHBP completed. BP06: B-056
IW JP of size 14C installed. BP06: B-172/173 rig-down in-progress. BP10: B-074 IW Unit
standby. BP14: B-165 JP assisted flow back in progress through B-166 flow arm. BP15: B-103
SIBHP IW completed.

BP03: B-187 JP assisted flow back in progress. BP06: B-053 IW SIHBP completed. BP06: B-
172/173 rig-down in-progress. BP07: B-060 IW SIBHP carried out. BP14: B-165 JP assisted flow
back in progress through B-166 flow arm. BP15: B-103 Tag HUD done at 765m.
BP03: B-187 JP assisted flow back in progress. BP06: B-172/173 rig-down in-progress. BP14: B-
165 JP assisted flow back in progress through B-166 flow arm.

BP03: B-187 JP assisted flow back in progress. BP03: B-026 TCI HRP unit standby. BP13: B-078
PCP wellhead greasing completed. BP14: B-165 JP assisted flow back in progress through B-166
flow arm. BP14: B-004 JP POOH for sand scouring.

BP03: B-187 JP assisted flow back in progress. BP03: B-026 Sim plug job in-progress. BP13: B-
078 PCP wellhead greasing completed. BP14: B-165 JP assisted flow back in progress through B-
166 flow arm. BP15: B-009 IW Wellhead greasing completed.

BP03: B-187 JP assisted flow back in progress. BP03: B-026 KCL pumping job in-progress. BP03:
B-129 PCP wellhead greasing completed. BP14: B-165 JP assisted flow back in progress through
B-166 flow arm. BP15: B-008 IW Wellhead greasing completed.
BP03: B-187 JP assisted flow back in progress. BP14: B-165 JP assisted flow back in progress
through B-166 flow arm. BP12: B-049 IW Wellhead greasing completed.

BP03: B-187 JP assisted flow back completed. BP14: B-165 JP assisted flow back in progress
through B-166 flow arm. 03B-026 KCL Pumping done. BP11: B-066 PCP Wellhead greasing IPM
completed.

BP14: B-165 JP assisted flow back completed. 04B-175/178: flow back in progress. 03B-026 KCL
Pumping done. BP03: B-024/071 PCP Wellhead greasing IPM completed. BP12-128 PCP
Wellhead greasing IPM completed. BP13-033 PCP Wellhead greasing IPM completed.

04B-175/178: flow back in progress. 03B-026 KCL Pumping done. 04B-038/06B-054 PCP
Wellhead greasing IPM completed. 11B-064: IW Wellhead greasing IPM completed.
04B-175/178: flow back in progress.
04B-175/178: flow back in progress. 06B-084: PCP WH greasing IPM done. 05B-041: IW WH
greasing IPM done.
04B-175/178: flow back in progress. 01B-104 04B-037: PCP WH greasing IPM done.
04B-175/178: flow back in progress. 14B-005: IW WH greasing IPM done.
04B-175/178: flow back in progress. 03B-127: PCP WH greasing IPM done. 06B-107: JP WH
greasing IPM done. 01B-099 / 01B-017: SIBHP done.
04B-175/178: flow back in progress. 03B-072: WH greasing done.
04B-175/178: flow back in progress. 03B-133: PCP WH greasing IPM done.

# Sensitivity: Internal (C3)


04B-175/178: flow back in progress. 09B-108: PCP WH greasing IPM done. 13B-116: Jet pump
retrieved, awaiting workover. 03B-026: Bottom hole plug installation done.

04B-175/178: flow back in progress. 15B-013: PCP WH greasing IPM done. 13B-116: Jet pump
retrieved, awaiting workover. 06B-053: Slick plug installed perforation completed.
04B-175/178: flow back in progress. 01B-018: PCP WH greasing IPM done. 13B-116: Jet pump
retrieved, awaiting workover.
04B-175/178: flow back in progress. 01B-015: PCP WH greasing IPM done. 13B-116: Jet pump
retrieved, awaiting workover.

04B-175/178: flow back in progress.

04B: B-175/178 flow back completed, Rig down in-progress. 13B: B-116 Jet pump retrieved,
awaiting workover. 01B: B-074 Casing patch retrieval done, Rig down in-progress. 06B: B-053
Memory gauge retrieval done Plug installed.

04B: B-175/178 flow back completed, Rig up in-progress for JP retrieval. 13B: B-116 Jet pump
retrieved, awaiting workover. 15B: B-103 Casing patch retrieval job in-progress. 01B: B-017
FRAC slick line job in-progress.
01B: TCI unit stand-by 13B: B-116 Jet pump retrieved, awaiting workover. 15B: B-103 Casing
patch retrieval job completed.
01B: B-017 Rig-up completed, preparation and execution of perforation in-progress. 13B: B-116
Jet pump retrieved, awaiting workover.
01B: B-017 Rig-up completed, fracturing investigation in-progress.
0

0
01B-017: Frac investigation in progress.
13B-137: SIBHP Tag HUD done.

11B-065: SIBHP.Job suspended.


07B-062: Jet pump installation in progress.

07B-062: Jet pump installed.

03B-073: Online MPLT in progress. 07B-062: Annulus inlet valve installation completed.
03B-073: Online MPLT job suspended.
04B-081: Lube and bleed job completed, PRV lined up.

-
BP09: 09B-067 Well head valves integrity and greasing done. BP14: 14B-166 Well head valves
integrity and greasing done.
BP07: 07B-060 Equipment movement for sand scouring activity in-progress. BP13: 13B-080
Well head valves integrity and greasing done.

BP07: 07B-060 Equipment movement for sand scouring activity in-progress. BP02: 02B-030
Well head valves integrity and greasing done. BP04: 04B-036 Well head valves integrity and
greasing done.

# Sensitivity: Internal (C3)


BP07: 07B-060 Equipment movement for sand scouring activity in-progress. BP13: 13B-169
Sand bailing completed by slickline.
13B-076: PCP IPM, WH greasing done.
12B-138: PCP IPM, WH greasing done. 07B-060: Sand scouring in progress.
07B-060: WBCO completed. HRP rig up i/p for sand scouring.
07B-060: Pressure test completed. Sand scouring will be done
07B-060: Sand scouring in progress. 06B-057: PCP WH Greasing IPM done. 05B-163: PCP WH
Greasing IPM done.
07B-060: Sand scouring chemical injection job completed. 06B-122: PCP WH Greasing IPM
done.
03B-073: IFO in progress. 10B-147: IW IPM WH greasing done. 13B-116: Rig up i/p. 04B-180:
JP installed. Flow back is planned.
03B-125: IFO in progress. 14B-117: IW IPM WH greasing done.

13B-113: IFO completed. 13B-116: Sand settling i/p. 02B-119: IW IPM WH greasing done.
13B-116: KCL pumping done. Settling i/p.

-
02B-029: Casing patch retrieval in-progress. 04B-180: Flow back in-progress.
02B-029: Well bore clean out (WBCO) in-progress. 02B-151: Rig-up in-progress for IFO. 04B-
180: Flow back in-progress.
02B-029: Well bore clean out (WBCO) completed. 02B-151: IFO survey in-progress. 04B-180:
Flow back in-progress. 15B-103: Rig-up in-progress for WBCO.

02B-029: Coil tubing stuck, Well bore clean out (WBCO) to be done. 02B-151: IFO survey
completed. 04B-180: Flow back in-progress through B-037 flow line. 15B-103: WBCO
completed, Sand scoring in-progress.

02B-029: Acid pumping done, Coil tubing tool stucked. 04B-180: Flow back in-progress through
B-037 flow line. 15B-103: WBCO completed, Sand scoring in-progress.
02B-029: Coil tubing tool got stuck. 04B-180: Flow back in-progress through B-037 flow line.
15B-103: CT completed. 02B-151: MPLT planned and unsuccessful.

# Sensitivity: Internal (C3)


RIG

VR06: 06B-057: Rig down completed hook-up in progress.

VR06: 07B-135: Tubing POOH in-progress.

VR06: 07B-135: Fishing in-progress. REPL14: 12B-126: Rod POOH in-progress.

VR06: 07B-135: Drivehead installation in-progress. REPL14: 13B-078: Rig standby.

VR06: 03B-133: Preparatory for rig-up in-progress. REPL14: 13B-078: Fishing completed BOP found passing
BOP replacement planned.

VR06: 03B-133: Rigup in-progress. REPL14: 15B-011: Rigup in-progress.

VR06: 03B-133: Tubing RIH completed. BOP N/U i/p. REPL14: 15B-011: Well killing i/p.

VR06: 03B-133: Rig down completed, moved to BWP11. REPL14: 15B-011: Well killing i/p.

VR06: 11B-066 Tubing RIH i/p. REPL14: 15B-011 T/s failed, moved to 13B-078

VR06: Standby at BP11 REPL14: 08B-150: Polish rod clamp troubleshooting done started.

VR06: 09B-069 rig up i/p. REPL14: Standby at BP08


VR06: 09B-069 Tubing POOH i/p. REPL14: Standby at BP08

VR06: 09B-069 Fishing tool retrieval i/p. REPL14: Standby at BP08


VR06: 09B-069 Fishing i/p. REPL14: Standby at BP08
VR06: 09B-069 Fishing i/p.

VR06: 09B-069 Fishing failed, Rig moved.


VR06: Moving to 05B-163 from BP13.
VR06: 05B-163: Sucker rod running in progres

# Sensitivity: Internal (C3)


VR06: 05B-163: Fishing in progress.

VR06: 05B-163: Fishing failed, Rig-up in progress for workover. REPL14: 13B-115: Rig-up in progress.
VR06: 05B-163: Tubing pull-out completed, BHA run in-progress. REPL14: 13B-115: Rod running completed.
Tubing pressure test attended and failed, awaiting workover.
VR06: 05B-163: Tubing pull-out completed, corrosion logging in-progress. REPL14: 01B-070: Fishing in-
progress.
VR06: 05B-163: Pressure test carried out and failed post packer set. Tubing pull-out in-progress for re-setting
the packing. REPL14: Stand b

VR06: 05B-163: Packer set , A-Annulus pressure testing in-progress. REPL14: Stand by

VR06: 13B-115 Rig-up in-progress. REPL14: 05B-163 Rig-up in-progress for rod running.

VR06: 13B-115 Tube final running in-progress. REPL14: 05B-163 Job completed, Rig-down in-progress.

VR06: 13B-115 Rod running in-progress. REPL14: Moved to NI field.


VR06: 13B-116 Rod running in-progress. REPL14: Moved to NI field.
VR06: 13B-116 WBCO completed. REPL14: Planned to 02B-121 for I PCP inspection.

VR06: 13B-116 : Rig down completed and moved to NI. REPL14: 02B-121 RRU troubleshooting in progress.
REPL14: 02B-121 Rod RIH in progress.
REPL14: 13B-090 fishing in progress. VR06: 15B-011: Rig up in progress.

REPL14: 13B-090: RIH completed.Drivehead installed. VR06: 15B-011: Job suspended. Will move to NI-03.
REPL14: 02B-121: Rod POOH in progress.

REPL14: 02B-121: iPCP replaced, Rod RIH in progress. REPL14: 03B-133: Polish rod clamping completed.

REPL14: 03B-071: Rig up completed.


REPL14: 03B-071: Rod POOH in progress, Rig maintenance.
REPL14: 03B-071: Fishing in progress.
REPL14: 03B-133: Rig down completed post stator flushing. BP07: Slot-109: Conductor casing drilling in
progress.
REPL14: 13B-162: Rig down completed post stator flushing. BP07: Slot-109: Conductor casing drilling in
progress. VR06: 15B-011: Rigup preparatory job in-progress.

REPL14: 13B-089: Rig up done. BOP pressure test in-progress. VR06: 15B-011: Fishing in-progress.
REPL14: 09B-067: Rigup in-progress. VR06: 15B-011: Rod RIH completed and drivehead installed Rig moved
to 04B-040

REPL14: 01B-142: Rig up planned. VR06: 04B-040: Rig-up in-progress.

# Sensitivity: Internal (C3)


REPL14: 13B-089: BOP N/U completed. VR06: 04B-040: Tubing POOH completed.
REPL14: 13B-078: Well killing i/p. VR06: 04B-040: Rod RIH i/p.
REPL14: Standby VR06: 13B-089: Fishing i/p.
REPL14: Standby at BP13 VR06: 13B-089: Tubing fishing i/p.
VR06: 13B-089: Fishing i/p.

VR06: 13B-089: Fishing i/p.

VR06: 13B-089: Final tubing running i/p. REPL14: 13B-078: Rig up i/p for stator flushing.
VR06: 13B-089: Rod RIH completed. Drive head installed. Rig down i/p. REPL14: 13B-078: Cable connection
done. Surface line hook up done.
VR06: Moved to Aishwarya. REPL14: 12B-161: kill wing motor cable removed.

REPL14: 12B-161: Well killing i/p.


REPL14: 12B-161: Well killing unsuccessful, rig moved to 01B-018.

REPL14: 01B-018 Rod pull out done, fishing tool run in progress. Quippo37: 12B-150: Rig movement i/p.
REPL14: 01B-101: Rig Movement in-progress. Quippo37: 12B-050: BOP Nipple-up in-progress.

REPL14: 01B-101: Fishing in-progress. Quippo37: 12B-050: Fishing in-progress.

REPL14: Stand by. Quippo37: 12B-050: Rig under maintenance.

REPL14: 03B-133: Rig movement in-progress. Quippo37: 12B-050: Tubing POOH in-progress.

REPL14: 03B-133: Drive head installation completed. Quippo37: 12B-050: Fishing in-progress.

REPL14: 03B-133: Stand by Quippo37: 12B-050: Fishing in-progress.

# Sensitivity: Internal (C3)