Professional Documents
Culture Documents
Case Study - MEA Circulation Pump
Case Study - MEA Circulation Pump
A-1164J
Content
z Problem
z Analysis
z Action
z Present Condition
Problem
This was a long pending issue and the
observation and history revealed the
following
10 9.7
9.5
mm
8.5 1.6
0
22/04/03 08.02.2003 20.10.03 29.03.04
Health Chart
Health Chart Good Limit Present Fair Limit
14 11.2 11.2
Velocity mm
9
4.5 4.5
4 0.8 1.6
-1
Turbine Pump
The End