SECTION E-E FLOOR PLAN DETAILS 13.

200
FLOOR PLAN 9.000 4.000 0.200
500
PC SLAB TO DE DETAILS

0.200
ROOF TERRACE
13.400 150
9.200 0.200 3.800 0.200
0.200 4.303 0.200 4.497 0.200 3.800 0.200

0.200

1.050
E

0.200
3800
0.200

1.250
2800

1.050
TC

BEDROOM
KITCHEN
BEDROOM

E E

0.200
TC
4490

2000X 1500
3.800

2
DINNING
2

8.250
KITCHEN W
E E
0.200

2400X900
DINNING 4300
8.650

RE RE

W/C 4X5 D
200mm thick masonry
2.000

9.700
PASSAGE walling to approval

9.500

9.900
0.200

East Elevation
13.950

E
2.050

100MM THICK RC ON 1000 gauge dpmon


50mm thick quality dust blinding on 300
handcore layer to SE details
W/C
0.200

LIVING
ROOM 13400
2.300

MASTER
BEDROOM East Elevation 1:139.52
4.000

4.000
0.200

0.200
4500x3000

4.000
W/C PORCH
BEDROOM
3
1.300

0.200 1.800 0.200 5.300 0.200 2.800


2.200

SEPTIC TANK DETAILS


2.000
CAPACITY DESLUDGING DIMENSIONS IN MM
TYPE NO OF
INTRVAL
(LITTERS) PERSONS A B C D E F1 F2
(YEARS)
SECTION A-A SEPTIC TANK DETAILS 800 800
125MM RCCOVER SLAB
600X450MM COVE
3000

6000
10

20
2

2 800
1000
1400
1000

1200
3000 1200 1400
E
INLET
MANHOLE
TO ENGINEERING DETAIL
AND FRAME 3600 1400 1500 1400
OUTLET
MANHOLE 9000 30 800 1400 1200 3600 1800 1500 1400
Revision History
2

12000 40
2 800 1600 1400 4000 2000 1500 1300 1. ROOF AREA RevID ChID Change Name 1:100
Date
West Elevation (1) 1:103.24
500 200 500
TWL 300
300 15000
INVERTED LEVEL OF 50 2 800 1600 1400 4000 2400 1500 1200
SUBSOIL DRAIN
INCOMMING DRAIN
10 MM WATER PROOVING
RENDERING TO APROVAL B
190 MM THICK MASONRY SLAB
WALL WITH 10 MM RENDERING
FLOOR PLAN NB:DEPTTH OF THE SOAK PIT IS TO BE SPECIFIED
TO APPROVAL
200
4000 800

100 100 200

A A B
E
(2400)
A
(1400) (1600) C
(1400) SOAK PIT
FLOOR PLAN

SECTION B-B FLOORPLAN B


600X450MM COVE
AND FRAME

12MM DIAMETER MS BARS


Company Title @INFITECT COSOLTANCY
AT 150MM C/C BATHWAYS
South Elevation 1:100
GENERAL NOTES :

1.THE SIZE OF THE WALL WIDTHS ARE 200MM AND TO BE RAINFORCED WITH HOOP IRON AT EVERY ALTANATE COURSE UNLESS
OTHERWISE STATED
North Elevation (1) 1:133.13
2 ALL COSTRUCTION WORK IS TO COMPLY WITH THE LATEST STANDARD CODES OF PRACTICE ,LOCAL AUTHORITY BY- LAWS,AND FIRE
REGULATIONS INFITECT COSOLTACY
10100
3 ONLY FIGURED DIMENSIONS TO BE TAKEN FROM THIS DROWINGS ALL DIMENSIONS ARE IN MILIMETRES(MM) UNLESS OTHERWISE NYERI
KENYA
SPECIFIED
South Elevation
10100

4 ALL WALLS HAVE DAMP PROOF COURSE (DPC) AT 150MM FROM GROUND LEVEL PROPOSED RESIDENTIAL
5 P.V. DENOTES PEMANENT VERTILATION AND PROVIDED ABOVE ALL DOORS AND WINDOWS WHERE INDICATED DEVELOPMENT PROJECT
012
6.ALL DRAINAGE PIPES PASSING UNDER BUILDING AND DRIVE AREA MAST BE OF PVC PIPE AND ENCASED IN CONCREAT NAIROBI
MERU
7.ALL SANITARY
Ground FloorWORKS
(3) TO BE IN ACCORDANCEWITH MOH RULES AND REGULATIONS 1:148.36 Drawing Name
60200

8.500g POLYTHENESHEETING AND ANT-TERMITE TREATMENT TO BE PROVIDED UNDER GROUND FLOOR SLAB ROOF AREA, Ground Floor (3),
DrawingSouth
Status Elevation, East
9.ALL RAINFORCED CONCRET WORKS TO BE IN ACCORDANCE WITH STRUCTURAL ENGINEER'S DETAILS
Elevation, West Elevation (1),
10.THE DOOR WIDTHS ARE 1.M AND 0.8M FOR W/C ,THE MAIN DOOR WIDTH IS 2M WIDTH
Modified byNorth Elevation (1) Date
11.LIVING ROOM WINDOWS WIDTHS ARE 1.5M OTHER ROOMS SHOULD BE 1.2 AS THIS CAN BE ADJUSTED DEPENDING ON THE SIZEAND
NB; ANY NESSESARY ADJUSTMENT
IMPRESSION OF THE ROOM Checked by Date
TO SARTISFY LATES BUILDING CODES IS
12.PROVIDE A ROW OF 600X600X PRECA50MM PRECAST CONCRET PAVING SLAB AROUND THE BUILDING UNLESS OTHERWISE STATED ALLOWED Drawing Scale
13. THIS DROWING IS THE AUTHOR'S COPYRIGHTAND CANNOT BE USED OR REPRODUCED IN PART OR IN A WHOLE WITHOUT THE - ANY UNREALISTIC MEASUREMENT IDENTIFIED 1:100, 1:148.36, 1:139.52,
AUTHOR'S CONSENT. CAN ALSO BE ADJUSTED AFTER CONSOLTING Layout ID 1:103.24, 1:133.13 Revision