You are on page 1of 11

CMS X-Tools Analysis Library - Change Log CMS

Preface 1

Change Log 2

Contact Information 3
CMS X-Tools Analysis Library
Change Log

English
Release 2018-07

English
Release 2018-07 1 / 11
CMS X-Tools Analysis Library - Change Log CMS

Safety Guidelines
This document contains notices which you should observe to ensure your own personal safety as well as to avoid property damage. The
notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring to property damage only
have no safety alert symbol

Danger
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Warning
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Caution
Used with the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury.

Notice
Used without the safety alert symbol indicates a potential situation which, if not avoided, may result in an undesirable result or
state.

When several danger levels apply, the notices of the highest level (lower number) are always displayed. If a notice refers to personal
damages with the safety alert symbol, then another notice may be added warning of property damage.
Qualified Personnel
The device/system may only be set up and operated in conjunction with this documentation. Only qualified personnel should be allowed to
install and work on the equipment. Qualified persons are defined as persons who are authorized to commission, to earth, and to tag cir-
cuits, equipment and systems in accordance with established safety practices and standards.
Intended Use
Please note the following:

Warning
This device and its components may only be used for the applications described in the catalog or technical description, and
only in connection with devices or components from other manufacturers approved or recommended by Siemens. This prod-
uct can only function correctly and safely if it is transported, stored, set up and installed correctly, and operated and main-
tained as recommended.

Trademarks
All designations marked with ® are registered trademarks of Siemens AG. Other designations in this documentation might be trademarks
which, if used by third parties for their purposes, might infringe upon the rights of the proprietors.
Copyright Siemens AG 2018. All rights reserved.
Reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be
liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved.
Disclaimer of Liability
We have checked the contents of this document for agreement with the hardware and software described. Since deviations cannot be
precluded entirely, we cannot guarantee full agreement. However, the data in the manual are reviewed regularly, and any necessary cor-
rections will be included in subsequent editions. Suggestions for improvement are welcomed.

English
Release 2018-07 2 / 11
CMS X-Tools Analysis Library - Change Log CMS

Table of Contents

1 Preface .......................................................................................................................................... 4
1.1 Purpose of this Document ......................................................................................................... 4
1.2 Validity of this Document ........................................................................................................... 4
1.3 Audience ...................................................................................................................................4
2 Change Log ................................................................................................................................... 5
2.1 V 04.04.02 ................................................................................................................................ 5
2.2 V 04.04.03 ................................................................................................................................ 7
2.3 V 04.04.04 ................................................................................................................................ 8
2.4 V 04.04.05 ................................................................................................................................ 8
2.5 V 04.04.06 ................................................................................................................................ 9
2.6 V 5.0.0.0 ................................................................................................................................. 10
3 Contact Information ...................................................................................................................... 11

English
Release 2018-07 3 / 11
CMS X-Tools Analysis Library - Change Log CMS

1 Preface

1.1 Purpose of this Document

This document contains the change log for the software


∂ CMS X-Tools Analysis Library V 5.0.0.0
of CMS product line.

1.2 Validity of this Document

This document is valid for the following software:


∂ CMS X-Tools Analysis Library V 5.0.0.0 including
o CMS Project Configurator V 5.0.0.0
ƒ CMS X-Tools Project Configurator V 1.3.0.0
ƒ CMS X-Tools Alarm Configurator V 1.3.0.0
ƒ CreateFileMapping V 1.3.0.0
ƒ Deploy Envelopes V 1.3.0.0
o CM Library V 5.0.0.0
o CMS X-Tools V 5.0 (2018-07-04) Analyzing Bundle 1
∂ CMS X-Tools Professional V 5.0
During the following pages, these software packages will be referred to by the term Analysis Library.

1.3 Audience

This document is intended for personnel involved in the commissioning and using of the software:
∂ Analysis Library

English
Release 2018-07 4 / 11
CMS X-Tools Analysis Library - Change Log CMS

2 Change Log

2.1 V 04.04.02

The following changes have been introduced:


CHANGE (File splitting of SPFs)
Changed the default file splitting interval of SPFs from 7 to 1 day.

CHANGE (Default display settings of complex data types)


Changed the default settings for displaying offline data such as Orbit, Spectra and TLC / TLC2D / RFM regard-
ing "update display time after action / open" for sliders and for online TLC / TLC2D / RFM to auto scale Y-axis.

CHANGE (Envelope Configuration)


It shall be possible to change an previously created alarm band in its name and center at the same time.

CHANGE (Project structure of reused Analysis)


Optimizing Project structure regarding multiple used Analysis such as Limit Check.

CHANGE (Incorrect spellings)


Corrected incorrect spelling in Vibration Spectra, General Spectra and General Spectra Order.

CHANGE (Improved Filter Parameter plausibility check)


Cut off frequency shall not be allowed to be equal the half of sample frequency, because they can lead to insta-
ble filters.

CHANGE (Scalar Data Structure)


Scalar data shall be created more clearly and OS Group categorized.

CHANGE (Improved loading of Spectra)


Within the MVF of the envelope configuration it was only possible to load spectra data from today back to n-
Days. Now it is possible to load spectra data for a specified time interval.

CHANGE (Improved loading of alarm band violations)


Within the MVF of any spectrum it was only possible to load the latest alarm band violations or all alarm band
violations. If only two alarm band violations shall be loaded the user needs to choose to load all alarm band
violations which may take up to several minutes or even more. It shall be possible to load the spectra data for a
specified time interval.

CHANGE (Calculated Spectra visualization)


Only a current violated spectrum is shown together with the Envelope data in the MVF. The Envelopes shall
always be visible together with the current calculated spectrum as it is implemented for time based data.

CHANGE (Improved Speed information)


The speed data shall be shown together with the frequency spectra data in the MVF, as it is implemented for the
envelopes configuration. In addition the current Operating State shall be shown in the Mimic Board MTC at the
bottom of the MVF. The speed data shall also be shown for order spectra together with the current Operating
State in the Mimic Board MTC at the bottom of the MVF.

CHANGE (Improved Speed information storage)


For order spectra the reference speed data shall be stored together with the spectra data as it is implemented
for frequency spectra. When the raw data storage for spectra data is activated, the trigger data shall also be
stored with the vibration data.

CHANGE (MVF Mimic Board Style)


Changed the look and feel of the used Mimic Boards within MVFs

BUGFIX (Data count initialized by zero outside OSG loop when using ISB Data Exchange)
Fixed a bug which occurred with activated ISB Data Exchange, if more than one OSG with different APs and
one OSG with no offline APs have been configured, which led to a missing ASF (Call Move Closed Data) which

English
Release 2018-07 5 / 11
CMS X-Tools Analysis Library - Change Log CMS

could not be found during the startup.

BUGFIX (Spectra Trend Data missing when using ISB Data Exchange)
Fixed a situation with activated ISB Data Exchange which could have led to receiving no data storage for the
alarmband trend data.

BUGFIX (Wrong File Counting when using ISB Data Exchange)


Fixed the data counting for the array definition which contained the to be stored data names and which could
have led to suspending of 99 Create ISB Data ASF during the "Apply" process.

BUGFIX (Unhandled exception in OSG Conditions ComboBox)


Fixed an unhandled exception while configuring an OSG and choosing a data name out of the drop down menu
of one of the three conditions. While the drop down menu was opened and trying to disable any condition the
exception occurred.

BUGFIX (Not working Templates (Custom) for ISB Data Exchange)


It was not possible to use custom templates in addition with ISB data exchange.

BUGFIX (Missing RMSAcc limit)


Fixed a bug where in case of X-Tools V 04.04 and using the MVF for RMSAcc online calculations with limit
check, the alarm level was missing in the MVF visualization.

BUGFIX (Not loaded Envelope)


Fixed a missing loading of the corresponding envelopes, when loading alarm band violated spectra data via the
MVF.

BUGFIX (Missing TLC2D output)


Fixed a bug where Offline Classification TLC2D produces no output because the DataNameZ was not stored by
the 00 Rawdataset SPF.

BUGFIX (Wrong Tab Index)


Corrected places where the Tab index of several windows for the parameter configuration of the GUI was in a
not correct order.

BUGFIX (OSG Condition overlapping)


Improved the error exception within OSGs regarding the used condition limits. If more than one signal was used
for the operating state detection, the conditions of one signal for one operating state shall allow to overlap with a
condition of the same signal for another operating state, in case the second signal has unique borders.

BUGFIX (Possible error caused by TrgConv())


TrgConv in CM Library did not put out a Data when the determined value was 0.

BUGFIX(Negative Values for OSG Properties)


Stopped users from entering negative values for several properties within the OSG configuration (Analysis Se-
quence, Spectra Storage Interval and OSG Number).

BUGFIX (Device Profile Files Configuration)


Corrected a not working “Move Up” Button” for the Device Profile Files Configuration.

BUGFIX (Wrong Spectra Output calculation)


Fixed a bug where the Spectra Output was calculated wrong in several Spectra Analyzing Packages.

BUGFIX (Wrong Orbit Output calculation)


Fixed a bug where the Orbit Output was calculated wrong in all Orbit Analyzing Packages.

BUGFIX (Not working Parameter Calculation with deactivated delay time)


Fixed a situation where the Parameter Calculation did not put out a result in case the delay time was deactivat-
ed.

BUGFIX (Plant Tree Del Shortcut)


Corrected the delete short cut functionality within the Plant Tree context menu, which was displayed to work
with “Del” but working with “SHIFT + DEL”.

English
Release 2018-07 6 / 11
CMS X-Tools Analysis Library - Change Log CMS

BUGFIX (Unhandled exception on adding an Asset to the wrong place)


Secured an unhandled exception which occurred when trying to add an Asset to a “System” or “Subsystem”
Node.

BUGFIX (Unhandled exception on manually deleting Custom CFs)


Secured an unhandled exception when a user removed his Custom Configuration Files out of the Custom folder
of his project while the Project Configurator GUI is running and afterwards tried to open a corresponding Con-
figuration Files dialog.

BUGFIX (Usage of Templated (Custom))


Not all Template (Custom) Files where used during the project creation.

BUGFIX (Alarm Configurator Registry Check)


Fixed an unhandled exception which occurred when the Alarm configurator was not able to determine the X-
Tools V 04.04 installation path.

BUGFIX (Alarm Configurator opening of MVFs)


Fixed an unhandled exception which could have occurred when trying to open a MVF of an corresponding
Spectra Analyzing Package out of the Alarm Configurator.

BUGFIX (Save As for Templates (Custom))


Fixed a situation where “Save As” did not work anymore, after the first saving of the Templates (Custom).

2.2 V 04.04.03

The following changes have been introduced:

CHANGE (Extension of CMS X-Tools Alarm Configurator)


Extended CMS X-Tools Alarm Configurator to optional act like an alarm notification system. Status information
about the configured measuring tasks are shown within the plant tree. Detected alarms are collected and shown
within an alarm list. No new alarm notifications are reported as long as they are not acknowledged.
Within the plant tree or alarm list all to the Measuring Task related MVFs can be directly opened in Professional
or Express edition.

CHANGE (Extended loading possibilities)


All MFVs of all Analyzing Packages have been extended to be able to load Offline Data for a certain time inter-
val.

CHANGE (Extension of MVF for editing of Envelopes)


All MVFs to edit Envelopes for spectral alarming have been extended to be able to load and show recorded
spectra/average spectra, maximum spectrum, recorded violation spectra/average violation spectra.

CHANGE (Adding of Mask Band RMS calculation to Spectra Analyzing Packages)


All Spectra Analyzing Packages have been extended to also calculate the RMS of the Envelope Mask Band,
visualize and store it as separate trend data.

CHANGE (Adding of a SuspendedCF monitoring for the complete Location)


A monitoring for suspended CFs for the complete Project Location has been added.

CHANGE (MindSphere Transfer)


A possibility to configure to be transferred results of Measurement Tasks to the MindSphere has been added. A
separated view on the main window can be activated via project settings and to be transferred data can be cho-
sen. X-Tools Storage Profiles of type MindSphere T001 will be automatically generated and integrated into the
project sequence.

BUGFIX (Endless waiting of Sequence Control ASF)


Fixed a situation where on high frequently leaving and entering of Operating States could lead to a state of the
Offline Sequence Control ASF, where it misses the discontinuity of the Operating State and waits endlessly.

BUGFIX (Wrong counting of Order Spectra Data)


Fixed a bug where during project creation the Order Spectra Data could have been counted wrong.

English
Release 2018-07 7 / 11
CMS X-Tools Analysis Library - Change Log CMS

2.3 V 04.04.04
The following changes have been introduced:

CHANGE (Default Clean-Up method of Storage Profile Files)


Changed the default Clean-Up method for all template Storage Profile Files from “assure remaining memory”, to
“do not perform Clean-Up”.

CHANGE (MindSphere Apspect Names)


Improved the automatic creation of MindSphere conform Aspect Names.

CHANGE (Color of warning borders)


Changed the color of all warning borders to a different yellow.

CHANGE (Mask Band RMS on version upgrade)


Fixed a suspend which occurred on Mask Band RMS calculation, when a project was originally created with a
Analysis Library < V 04.04.03.

BUGFIX (Wrong calculation of GblCntrlV)


Fixed a bug where the user Function GblCntrlV of the CM Library did not calculate the proper status value for all
inputs.

BUGFIX (Wrong speed relation in frequency spectrum Monitoring View Files)


Fixed a bug where the reference speed within the default Monitoring View Files of the Project Configurator has
a wrong data relation in case of using a Professional and Express Server in parallel.

BUGFIX (Exception on MindSphere upload with OSGs with different number of Operating States)
Fixed a bug where an exception was thrown on using MindSphere upload configuration window and having
Operating State Groups with different numbers of Operating States.

BUGFIX (Alarm Configurator – Multiple PG and OS)


Fixed minor errors regarding correct handling of multiple Parameter Groups and Operating States in Alarm Con-
figurator.

BUGFIX (Wrong creation of ExtrmVal Offline View)


Fixed a wrong MVF creation for ExtrmVal Online Measuring Task.

BUGFIX (Folder creation of “03 Alarm Events)


Corrected the folder creation for “03 Alarm Events” within the project folder “00 Project Setup”, in case this fold-
er was not present yet, e.g. on using a project created with some older Project Configurator version.

BUGFIX (Minor corrections regarding MindSphere Upload)


Minor errors regarding MindSphere upload SPF creation and data assignment have been made.

2.4 V 04.04.05
The following changes have been introduced:

FEATURE (Multi change of Parameters - Names)


Introduced a possibility to change the used data names for multiple Measurement Tasks

CHANGE (Default Storage Location for MindSphere)


Changed the default storage location for SPF Templates used for MindSphere upload to “MindSphere Agent
Files”.

CHANGE (Selecting of correct Type PG and OS when clicking “Edit” on an alarm entry in Alarm Config-
urator)
When clicking on an Alarm Entry with of any Spectral Measuring Task, the Type, Operating State and Parame-
ter Group, which caused the alarm is now suggested as selection in the appearing dialog.

BUGFIX (Storage Mode of Speed for Violation Spectra)


Corrected the Storage Mode for Speed Data when archiving a Spectrum to “Changes Only”.

BUGFIX (Clean up did not work for a too large number of files)
English
Release 2018-07 8 / 11
CMS X-Tools Analysis Library - Change Log CMS

Corrected the Clean Up of old files which were not needed after changing the Project Configuration.

BUGFIX (Alarm Notification did not work correctly for Orbits)


Fixed a Bug where Alarm Notifications in Alarm Configurator were not displayed correctly.

BUGFIX (Context Menu for Measurement Tasks list)


Fixed a Bug where the context menu of the Measurement Tasks list did not open anymore.

BUGFIX (Long Term Storage MindSphere Upload not working correctly)


Fixed a Bug which prevented assigned long term storage data to be uploaded to MindSphere.

BUGFIX (Edit PG does not always open the right PG)


Fixed a Bug which could occurred when trying to edit Parameter Groups within the Manage Parameter Groups
dialog.

BUGFIX (Rename of OSG)


Fixed a Bug where after renaming of an OSG assignments of PGs were not correct anymore.

BUGFIX (View in MTS for SpmOrdEnvAcc)


Fixed a Bug where choosing “View in MTS” out of Alarm Configurator for SpmOrdEnvAcc Measuring Tasks did
not work in all cases.

BUGFIX (Find in PlantOverview/DataGrid does not work for Orbit and Current Alarm Entries)
Fixed a Bug where choosing “Find in PlantOverview” does not work for Orbit and Current Alarm Entries” out of
Alarm Configurator.

BUGFIX (Create ABTrend MVF)


Improved the characters within the path structure, which is automatically built on creating Alarm Band Trend
MVFs.

2.5 V 04.04.06
The following changes have been introduced:

CHANGE (Editing of Envelopes while Project is running)


Improved the ability of editing Envelopes of a Project while this is running to not end up in a deadlock in case of
bad timing.

CHANGE (Improvement of ABTrend CF creation)


Improved the creation of CFs to view and store data of Alarm Band Trends, because in some scenarios it can
happen that these files need to be recreated.

BUGFIX (Storage of Mask Band RMS Trends)


Fixed a Bug which caused that not all values of the Max Band RMS Trend where stored in all cases.

BUGFIX (View/Edit/Find in Alarm Configurator)


Fixed a Bug where in some cases View/Edit/Find was not working properly in Alarm Configurator becuse it did
not take the PG into account for detection.

BUGFIX (Project saving and immediate creation)


Fixed a Bug which led to not recognizing the create CF command out of Project Configurator in case after sav-
ing the Project the create CF command was fired immediately.

BUGFIX (Project creation with still opened Alarm Configurator)


Fixed a Bug which led to an exception and happened when a Project was going to be closed with the (x) button
of the main form and the Alarm Configurator of this Project was still opened.

BUGFIX (General Classification wrong parameter check)


Fixed a Bug where the entered Upper and Lower boarder for Analyzing Package General Classification where
not checked properly.

English
Release 2018-07 9 / 11
CMS X-Tools Analysis Library - Change Log CMS

2.6 V 5.0.0.0
The following changes have been introduced:

CHANGE (Removing of Max Band Amplitudes MVFs and SPFs)


Stopped to remove already created Max Band Amplitudes MVFs and SPFs when performing an apply-operation
of Amplitude Trends.

CHANGE (Bold Fonts)


Changed bold fonts to also match to different DPI settings of Windows 7 and Windows 10.

CHANGE (Loading of ABTrends in different Operating States)


Removed the field for entering the OS number on MimicBoard for loading ABTrends, because it is not needed
and done out of Alarm Configurator.

BUGFIX (Wrong LoadAB ASF creation)


Fixed a Bug where it could happen on usage of multiple Operating States, that the Operating State Group num-
ber was assigned wrong.

BUGFIX (MaskBandRMS recalculation)


Fixed a Bug where on several Operating States and recalculation of Trend Data the MaskBandRMS calculation
suspended with an error message.

BUGFIX (Stop Events in Trend Data)


Fixed a Bug where Data Stop Events where kept in created Trend Data, although they are not wanted there.

BUGFIX (Missing Alarm Notification)


Fixed a Bug where it could happen that an Alarm Notification was not properly communicated to Alarm Configu-
rator.

English
Release 2018-07 10 / 11
CMS X-Tools Analysis Library - Change Log CMS

3 Contact Information

Should you have any questions concerning the software application, please refer to the Industry Sector Tech-
nical Support.

Department
Siemens AG
Digital Factory
Phone
+49 (0) 911 895 7222 (Monday to Friday, 09:00 am to 05:00 pm CET/CEST)
Fax
+49 (0) 911 895 7223
Internet
https://support.industry.siemens.com/

Thank you for using one of the above mentioned contacts to ensure your inquiry is registered and can be pro-
cessed.

English
Release 2018-07 11 / 11

You might also like